The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most homebuyers.
Your participation is requested
Your presence is requested during this inspection. A written report will not substitute for all the possible information that can be conveyed verbally by a shared visual observation of the conditions of the property.
How to Read This Report
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, descriptions, videos and hot links to additional information.
The best way to get the layers of information that are presented in this report is to read your report online (the HTML version), which will allow you to expand your learning about your house. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information. The HTML version of this report also contains streaming videos. Short video clips often contain important information and critical context and sounds that can be difficult to capture in words and still pictures.
For the most reliable viewing experience, I recommend viewing the report on as large a screen as practical, as much detail can be lost on small devices like smart phones. For similar reasons, reports should only be printed in color to retain as much detail as possible and minimize misinterpretation of photographs.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin.
Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section and it may simply say “tested,” or “inspected.”
Observation Labels
All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
- REPAIR NEEDED:Repair and maintenance items noted during inspection. Please note that some repair items can be expensive to correct such as re-finishing hardwood floors, but are considered simply repair items due to their cosmetic nature.
- IMPROVE/UPGRADE:Observations that are not necessarily defects, but which could be improved for safety, efficiency, or reliability reasons.
- MONITOR CONDITION:Items that should be watched to see if correction may be needed in the future.
- DEFERRED MAINTENANCE:These are repair items that should be considered "routine building ownership items," such as servicing the furnace, cleaning the gutters or changing the air filters in the furnace.
- Disclaimer:Detailed description of various aspects of the property noted during the inspection.
- REFER TO SPECIALIST:Observation such as a buried oil tank that may require further investigation to determine the severity and / or urgency of repair.
- NOTES:Refers to aside information and /or any comments elaborating on descriptions of systems in the building or limitations to the building inspection.
Pest Inspection
All items with the bug logo () are part of a structural pest inspection. If your inspector included a structural pest inspection as a part of the scope of your home inspection, you can distinguish pest inspection items by this logo. You can also go to the pest inspection summary page to see a summary of the items that are part of a pest inspection.
Summary Page
The Summary Page is designed as a bulleted overview of all the observations noted during inspection. This helpful overview is not a substitution for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report as the Summary Page does not include photographs or photo captions.
Moisture Meter Testing
Where moisture meter testing is indicated in this report a Protimiter Survey Master Dual Function was used.
Summary
Repair Needed
- ED-1 Exteriors and Decks - Siding and Trim:
Localized siding repairs are needed to the exterior. Hire a licensed general contractor to further evaluate and repair all damaged siding as needed.
- K-2 Kitchen - Dishwasher:
The loose dishwasher should be secured to the countertop and cabinets as needed to prevent a tipping hazard that could damage the plumbing.
- K-4 Kitchen - Refrigerators:
The fridge is not well mounted. This is a potential safety hazard. Repair / secure as needed.
- B-2 Bathrooms - Sinks/Cabinets:
The faucet to the downstairs bathroom sink is loose and requires repair.
- I-5 Interior - Windows:
Some window hardware are too tight to operate and require adjustment / repair for proper operation of the locking hardware.
Improve/Upgrade
- ED-3 Exteriors and Decks - Exterior Doors:
The rear exterior was not locking correctly and requires adjustment / repair.
- K-1 Kitchen - Dishwasher:
No visible air gap installed at the dishwasher drain line. The lack of an air gap can allow dirty waste water to drain back into the dishwasher during operation. We recommend installing an air gap device to prevent contamination of clean dishes.
- K-5 Kitchen - Sinks and Faucets:
The kitchen sink has a visible gap that requires additional trim or sealing to prevent moisture intrusion and ensure a finished appearance. Recommend proper sealing or trim installation. The kitchen sink has a visible gap that requires additional trim or sealing to prevent moisture intrusion and ensure a finished appearance. Recommend proper sealing or trim installation.
- B-1 Bathrooms - Sinks/Cabinets:
The sink in the main floor bathroom is loose and needs to be secured to prevent accidental damage to the sink or plumbing.
- I-1 Interior - Flooring:
Gap noted at the flooring material. Repair as needed to prevent water entry.
- I-3 Interior - Interior Doors:
The door at the main floor bath binds in the frame. Adjustment is needed to restore proper function.
- I-4 Interior - Windows:
Window screens were noted to be missing for some of the windows. Inquire with the seller to make sure all window screens are included and installed as desired prior to close. Photos are representative only.
Monitor Condition
- F-1 Foundation/Substructure - Foundation Type:
Minor crack(s) noted at the visible foundation walls. This type of cracking is fairly common and in many instances does not relate to serious foundation issues. We suggest sealing the exterior cracks to prevent water intrusion and monitor the affected area for signs of expansion or movement. If concerned, or if expansion is noted, we suggest consulting with a qualified, licensed contractor for further assessment.
Deferred Maintenance Items
Conditions
- GC-1 General Comments - Building Characteristics, Conditions and Limitations:
LIMITED REVIEW: Water service to the property was off at the time of the inspection. Due to this condition, we were unable to fully inspect and test plumbing fixtures and components, assess adequate water flow and drainage, check water pressure and inspect general condition of the plumbing system. We suggest consulting with the seller to ensure service is restored and the affected systems(s) or component(s) inspected by a qualified professional prior to closing.
Additionally, whenever fuel, electricity or water is to a structure is shut down, we cannot restore or switch on service. This is because there may be leaks or unforeseen safety issues related to the interruption of service. In the event that service has been interrupted by the utility company, we are unable to restore service.
- P-1 Plumbing - Waste System:
Plumbing drain installation was incomplete at multiple sinks during inspection. Buyer is advised to verify these before closing.
- ES-2 Electric Service - Electric Service Equipment:
Several electric breakers were off at the time of inspection. I do not switch breakers back on that were off, as these could be off for safety reasons. I recommend inquiring with the seller for additional information and then have these circuits reinspected as needed.
- K-3 Kitchen - Refrigerators:
The refrigerator was inoperative at the time of inspection due to not having power. Buyer is advised to verify this during final walk through.
Due Diligences
- HC-1 Heating, Cooling - Additional Heat/Cooling Sources:
The electric radiant floor in the master bathroom was turned on during the inspection, but no noticeable temperature change was observed. Recommend consulting with the seller to confirm functionality and any required operation procedures.
- ES-1 Electric Service - Incoming Electric Service:
A faint buzzing sound was noted at the utility line during the inspection. This may indicate a potential electrical issue or loose connection. It is recommended to contact the utility provider for further investigation and necessary repairs to ensure safety and proper function.
- L-1 Laundry - Washer:
Electrical power to the washer and dryer was shut off at the time of the inspection due to incomplete installation. Whenever fuel, electricity or water to a home or appliance is shut down, we do not restore or switch on service. There may be unforeseen safety issues related to the interruption of service. We suggest consulting with the seller regarding this condition and to have service restored. We further suggest the affected systems(s) or component(s) be inspected by a licensed, qualified individual prior to closing.
Full report
Exteriors and Decks
Attached Stairs and Railings
Siding and Trim
Eaves/Soffits
Exterior Doors
Exterior Windows
Exterior Electrical/Faucets
Heating, Cooling
Heating Systems
Heat Pump/Air Conditioning
Thermostat(s)
Ducting/Distribution
Additional Heat/Cooling Sources
Fresh Air Circulation
Electric Service
Incoming Electric Service
Electric Service Equipment
Electrical Grounding System
Electrical Bonding System
Appliance Disconnects
Branch Wiring/Electrical Fixtures
Branch Wiring
Receptacles and Fixtures
Smoke and Carbon Monoxide Alarm Systems
General Comments
Building Characteristics, Conditions and Limitations
Type of Inspection: Standard Inspection
Photo Comments: Photos included in this report are representative of conditions and may not show all affected areas or materials noted in the various report sections. If areas, locations or components are not specifically identified, you should assume that conditions noted are present in multiple areas. If we recommended further review, maintenance or repairs, all related/similar areas, locations or components should be assessed by an appropriate and qualified professional. (Example: Separated Caulking - photos may show one or more areas, but all exterior caulk should be checked and repaired to prevent water intrusion and associated deterioration.)
Attending the Inspection: Realtor's Associate
Inspector/State License Number:
Anh Le, #22014482
Type of Structure: Single Family
Approximate Square Footage: 1123
Year Built - 2000's: 2025
Occupancy: Vacant - Staged
Animals Present: None
Weather Conditions: Clear
Approximate temperature: 55 degrees
Ground/Soil surface conditions: Dry
Orientation of Report: Facing structure from the street
Staged Dwelling: The dwelling appears to be staged with furnishings. Consistent with our standards of performance, we do not move furniture or other materials during an inspection. Due to this condition, some areas of the dwelling may not have been accessible for inspection. We suggest the client confirm the condition of any hidden areas prior to closing.
New Construction - Incomplete Installation(s): During the course of the inspection, we might see incomplete installation or components without electrical power, water supply or gas supply. The client is advised that whenever fuel, electricity or water is disconnected or turned off to any component or appliance, we do not restore service, plug in appliances or turn on gas or water valves. The is because there may be unseen safety issues, incomplete installations, possible leaks, etc. Whenever we note untested components or incomplete installations in this report, we suggest the client confirm with the seller/builder that the work is safely completed and the system or component is functional. We also suggest the client confirm proper function of any affected system or component prior to closing. In some instances, this may require the service of a qualified professional.
Locations and details of these conditions will be noted in related sections throughout this report.
LIMITED REVIEW: Water service to the property was off at the time of the inspection. Due to this condition, we were unable to fully inspect and test plumbing fixtures and components, assess adequate water flow and drainage, check water pressure and inspect general condition of the plumbing system. We suggest consulting with the seller to ensure service is restored and the affected systems(s) or component(s) inspected by a qualified professional prior to closing.
Additionally, whenever fuel, electricity or water is to a structure is shut down, we cannot restore or switch on service. This is because there may be leaks or unforeseen safety issues related to the interruption of service. In the event that service has been interrupted by the utility company, we are unable to restore service.
Roof and Gutters
Roofing Materials
Method of Inspection: Drone
Roof Style: Gable
Roofing Type: Composition Shingle
Age of Roofing (if known): New/Recent installation
Flashings: Appear intact
Multiple Layers?: No
The roofing materials show normal condition for the age and type. No damaged or missing materials, or excessive deterioration noted at the time of the inspection. Roof appears to be in normal condition. Seasonal inspection of the roof is recommended to ensure optimal performance. Older roof should be inspected by a professional annually.
Gutter/Downspout Systems
Gutter and Downspout Materials: Metal gutters and downspouts
Downspout Discharge: Discharge above ground, Discharge into underground drains
Chimneys
Chimneys
Number of Chimneys: No chimneys
Grounds
Lot Description
Lot/Site Description: Sloped lot
Grade at Foundation: Adequate
Property Drainage: Appears adequate
Fencing/Gates
Fencing/Type(s): Excluded from inspection ( If present )
Retaining Walls
Retaining Wall Materials: Stacked concrete block
Exterior Paving
Walkways: Concrete
Patio(s): Concrete
Landscape Steps
Materials: Concrete steps
Vegetation/Trees
Trees/Vegetation: Adequate clearance noted
Foundation/Substructure
Foundation Type
Foundation - Perimeter: Raised - Poured concrete
Foundation Configuration: Slab on grade
% of Foundation Not Visible: 50%
Minor crack(s) noted at the visible foundation walls. This type of cracking is fairly common and in many instances does not relate to serious foundation issues. We suggest sealing the exterior cracks to prevent water intrusion and monitor the affected area for signs of expansion or movement. If concerned, or if expansion is noted, we suggest consulting with a qualified, licensed contractor for further assessment.
Exteriors and Decks
Attached Stairs and Railings
Exterior Stairs: Concrete steps
Exterior Guardrails/Handrails: Metal railing
Siding and Trim
Siding Material: Cement-fiber
Trim Material: Wood, Fiber cement
Localized siding repairs are needed to the exterior. Hire a licensed general contractor to further evaluate and repair all damaged siding as needed.
Eaves/Soffits
Eave Style/Materials: Exposed rafters
Thin paint noted at the exposed plywood eaves and siding. We recommend the affected areas be cleaned, prepped, caulked and painted according to current standards to ensure protection of the materials and prevent water intrusion.
Exterior Doors
Exterior Door Type: Tested
Doorbell: Functional
The rear exterior was not locking correctly and requires adjustment / repair.
Exterior Windows
Windows/Frames: Vinyl frames
Window Screens: Some screens missing
Exterior Electrical/Faucets
Exterior Electrical Components: GFCI Protected
Exterior Faucets: Frost-proof type w/anti-siphon
Fuel Storage and Distribution
General Comments
We found no evidence of natural gas, fuel oil or propane gas service, supply or equipment during the inspection. If any of these services are desired, consult with an appropriate professional.
Parking Type/Conditions
Garage/Carport General
Parking Type: No Covered Parking
Heating, Cooling
Heating Systems
Heating Equipment: Split-system heat pump - see Heat Pump/Air Conditioning section
Heat Pump/Air Conditioning
Type of System: Split-system heat pump (mini-split)
Manufacturer: Mitsubishi
Manufacture Date/Age: 2024
Exterior Equipment Location(s): Left side of building
Interior Unit Location(s): Living room, Upper Bedroom, Ensuite Bedroom
Energy Source: Electric
The heat pump system was tested in heating mode only as it was too cold to test in cooling mode. This means that the switching valve and condensate collection system could not be tested during this inspection today.
Electric split-system type heat pump. An electrical disconnect is installed near the exterior unit. Typical life expectancy is approximately 20 years. Units may exceed this range. Heat pump function was tested at the interior distribution units in heating and cooling modes and appeared to function properly at the time of the inspection.
A heat pump is essentially an air conditioning system that can operate in reverse creating heat as well as cold. If the unit is functioning properly in either heating or cooling mode, it indicates that the major components are operational. Adequate air flow is important to the efficiency of these units; vegetation should be kept trimmed away from the condenser and prevent storing items near the unit which could affect air circulation. If a detailed evaluation of the heating or cooling capacity of this unit is desired, a licensed HVAC contractor should be consulted.
Thermostat(s)
Thermostat Type: Manual
Ducting/Distribution
Heat Source in Each Room: Present
Additional Heat/Cooling Sources
Description: Radiant floor
Fresh Air Circulation
Bath Fan Ducting: Ducted to exterior
Kitchen Fan Ducting: Ducted to exterior
Water Heaters
Water Heater
Water Heater Type: Tank Style
Energy Source: Electric
Manufacturer: Rheem
Capacity: 50 gal
Manufacture Date/Age: 2024
Water Heater Location: Laundry room
Pressure Relief Valve: Installed
Seismic Restraints: Installed
Expansion Tank: Installed
Drain Pan: Installed w/drain
Water Temperature
Water Temperature During Inspection: Unable to Test
Plumbing
Water Meter
Water Meter Location: Front parking strip
Enclosure Conditions: Located/Inspected
Water Service
Water Service/Source: Public Water Utility
Main Water Shut-off Location: Laundry room
Main Supply Pipe: Pex ( Plastic )
Distribution Pipe
Supply Pipe Materials: PEX Tubing (cross-linked polyethylene)
Functional Flow: Adequate
Waste System
Waste System: Public Sewer System
Waste and Vent Pipe Materials: ABS plastic, PVC
Location of Sewer Cleanout: Kitchen
Exterior Hose Bibs
Not operating
Electric Service
Incoming Electric Service
Service Entrance: Overhead
Meter Base Amperage: 200 Amps
Service Voltage: Voltage assessed visually
Overhead incoming electrical service. Visible service equipment appeared intact.
A faint buzzing sound was noted at the utility line during the inspection. This may indicate a potential electrical issue or loose connection. It is recommended to contact the utility provider for further investigation and necessary repairs to ensure safety and proper function.
Electric Service Equipment
Panel Type: Breaker Switches
Panel Manufacturer: Square D
Main Panel Location: Bedroom
Main Panel Amperage: 125 amps
Service Entrance (SE) conductor Size: Aluminum, 1/0, 125 amps
Visible portions of the circuit breakers appeared intact. We do not test all circuit breakers for proper function. If a detailed testing of the breakers and electrical circuits is desired, consult with a licensed electrician.
No overheating was noted. The electric panel seems to be performing well to date.
All circuits appeared to be labeled. Determining if each circuit is correctly marked is beyond the scope of this inspection. If desired, a licensed electrician may be consulted for this information.
Breaker spaces were present at the panel for expansion of electrical circuits.
Several electric breakers were off at the time of inspection. I do not switch breakers back on that were off, as these could be off for safety reasons. I recommend inquiring with the seller for additional information and then have these circuits reinspected as needed.
Electrical Grounding System
Electrical Grounding: Grounding System Not Confirmed
During a visual inspection, every effort is made to inspect the visible components of the electrical system grounding. The grounding system is critical for safely discharging electrical surges, especially in the case of lightning strikes. There is no way in the context of a building inspection to verify the "effectiveness" of the grounding system as much of the system is not visible and there are not practical tests one can perform in the way we can test a furnace or a plumbing fixture. However, there are many things that can lead me to recommend further evaluation of the grounding system by a licensed electrical contractor and they will be documented in the observations below if discovered.
Electrical Bonding System
Electrical Bonding: Bonding Connections Not Located
Bonding connections were not visible at the time of the inspection. This is a common condition as bonding connections are often hidden within wall or floor cavities or behind finished surfaces. Due to this condition electrical bonding could not be confirmed.
Electrical bonding is an important system intended to control stray voltage which can affect metal systems in the building. If confirmation of electrical bonding is desired, consult with a licensed electrician.
Appliance Disconnects
Disconnects Noted: Heat Pump
Branch Wiring/Electrical Fixtures
Branch Wiring
Wire Material: Solid Copper
Wiring Type: Non-metallic sheathed cable
Receptacles and Fixtures
Inspection Method: Random Testing
In most buildings, we operate all accessible wall switches (lights, fans) and approximately 25% of the outlets (minimum 2 per room). If any anomalies are noted we will test additional receptacles and attempt to identify the issue.
Tested devices and fixtures appeared functional and intact, unless noted elsewhere in this report.
Receptacle Type(s): Grounded 3-wire receptacles
In most buildings, we operate all accessible wall switches (lights, fans) and approximately 25% of the outlets (minimum 2 per room). If any anomalies are noted we will test additional receptacles and attempt to identify the issue.
Tested devices and fixtures appeared functional and intact, unless noted elsewhere in this report.
During inspection I test all Ground Fault Circuit Interrupter (GFCI) devices that are readily accessible. GFCI's are those electric receptacles with re-set buttons that you commonly see in bathrooms, kitchens and at the exterior of the building. GFCI's are important safety devices that limit the duration of electrical shocks and have demonstrably saved lives. I recommend being aware of where re-set buttons are located in the house as GFCI's can trip and disable a circuit which can not be re-energized without re-setting the button. I avoid testing to determine if a receptacle or circuit is GFCI protected if it is not clear where the re-set button can be found. This is because re-set buttons can be concealed behind stored items, so such a test risks disabling a circuit in the building. Occasionally, during testing of GFCI's one can fail. This is a statistical reality that some of these devices will fail under testing and require replacement after testing.
Smoke and Carbon Monoxide Alarm Systems
Smoke Alarms Noted:
In all sleeping areas
On main floor
On 2nd floor
CO Alarms Installed:
On main floor
On 2nd floor
Kitchen
Ranges, Ovens, Cooktops
Range/ Oven /Cook-tops: Unable to test
Dishwasher
Dishwasher: Unable to test
Dishwasher Air Gap: None noted
Refrigerators
Refrigerator: Unable to test
Disposers
Disposer: Not installed
Ventilation Method
Kitchen Exhaust: Tested
Kitchen Electrical
Tested
Sinks and Faucets
Not tested
The kitchen sink has a visible gap that requires additional trim or sealing to prevent moisture intrusion and ensure a finished appearance. Recommend proper sealing or trim installation. The kitchen sink has a visible gap that requires additional trim or sealing to prevent moisture intrusion and ensure a finished appearance. Recommend proper sealing or trim installation.
Cabinets and Countertops
Cabinet Material: Wood/Plywood
Countertop Material: Intact
Bathrooms
Bathtub / Shower
Not tested
Toilets
Not tested
Sinks/Cabinets
Sinks/Faucets: Not tested
Cabinets/Counters: Appeared intact
Bathroom Electrical
Tested
Bathroom Ventilation
Ventilation Type: Ceiling fan(s)
Laundry
Washer
Not Installed
Electrical power to the washer and dryer was shut off at the time of the inspection due to incomplete installation. Whenever fuel, electricity or water to a home or appliance is shut down, we do not restore or switch on service. There may be unforeseen safety issues related to the interruption of service. We suggest consulting with the seller regarding this condition and to have service restored. We further suggest the affected systems(s) or component(s) be inspected by a licensed, qualified individual prior to closing.
Dryer
Dryer: Not installled
Laundry Ventilation
Ventilation Type: Ceiling Fan
Interior
Flooring
Floor Materials: Inspected
Floor Settlement: None noted
Gap noted at the flooring material. Repair as needed to prevent water entry.
The Vinyl flooring is loose. Repair as desired.
Walls, Ceilings, Trim and Closets
Wall and Ceiling Materials: Gypsum board/Drywall
Interior Doors
Windows
Window: Tested
Please be advised that during the home inspection, any windows that are blocked by personal items such as couches, bed frames, or other large furniture may not be accessible for testing. In such cases, the inspector will be unable to verify the operation, condition, or functionality of those windows. We recommend that all windows be made accessible prior to the inspection to ensure a comprehensive evaluation.
Window screens were noted to be missing for some of the windows. Inquire with the seller to make sure all window screens are included and installed as desired prior to close. Photos are representative only.
Some window hardware are too tight to operate and require adjustment / repair for proper operation of the locking hardware.
Stairs/Railings
Standard
Attic
Attic Access
Access/Location: No access
Vaulted ceilings are present in this home. With this type of construction, access is often not available between the ceiling and roof. Due to this condition, we are unable to view materials and conditions in this area. If there are concerns regarding these areas we suggest contacting a qualified specialist for further evaluation.
Checking Out Procedure
Check Out List
Oven:
Off
Lights:
Off
Heating and Cooling:
Restored to Pre-inspection temperatures
Appliances:
Off / finishing cycle