HOME INSPECTION SCOPE, LIMITATIONS, AND IMPORTANT INFORMATION
This report is best viewed on a computer or tablet for the clearest formatting and photo detail.
PURPOSE OF THE INSPECTION
This home inspection is a visual, non-invasive evaluation of the home's readily accessible systems and components at the time of the inspection. The purpose is to provide a practical understanding of the property's condition based on visible observations. While a home inspection helps reduce risk, it cannot eliminate it, and should be used to help prioritize repairs, maintenance, and future improvements.
SNAPSHOT IN TIME
This inspection reflects the condition of the property only at the time of the inspection. Conditions may change due to weather, occupancy, maintenance, repairs, or normal aging. Hidden, intermittent, seasonal, or concealed conditions may exist that were not visible during this visual inspection.
SCOPE OF INSPECTION
The inspection includes a general review of the home's major, readily accessible components, which may include:
• Roofing
• Exterior
• Structure
• Attic
• Plumbing
• Electrical
• Heating and cooling systems
• Interior
• Insulation and ventilation
• Built-in appliances
• Garage, basement, and crawlspace (where applicable)
The inspection is visual and non-invasive. It is not technically exhaustive and does not identify every cosmetic, minor, concealed, or future condition.GENERAL LIMITATIONS
Any areas identified as limited, inaccessible, obstructed, concealed, unsafe, or otherwise unavailable for inspection may contain conditions that could not be determined at the time of the inspection.
This inspection is:
Visual and non-destructive
Limited to readily accessible areas
Performed without dismantling systems or moving personal belongings
The inspection does not include:
Destructive testing or disassembly
Engineering analysis
Code compliance certification
Permit or municipal research
Identification of all concealed or latent defects
Areas that are concealed, obstructed, unsafe, inaccessible, or otherwise unavailable for inspection are outside the scope of this inspection.
ACCESS AND OCCUPANCY
Furnishings, storage, finishes, insulation, and personal belongings may limit visibility. I make every reasonable effort to inspect accessible areas without disturbing personal property; however, concealed conditions may remain hidden.
UTILITIES, WEATHER, AND OPERATING CONDITIONS
Some systems may not be operated when doing so could cause damage, create a safety concern, violate manufacturer recommendations, or when weather, seasonal conditions, utilities, or access restrictions prevent normal operation.
MODERN STANDARDS
This is not a code compliance inspection. However, references to modern standards, manufacturer specifications, common installation practices, and current safety recommendations may be included to help explain why a condition may be considered a concern. Recommendations may occasionally reference modern safety practices, manufacturer guidance, or current installation standards. This does not necessarily mean a component was improperly installed at the time of construction, only that improvements may be beneficial by today's expectations. Especially in older homes, it is common to find conditions that were acceptable at the time of installation but are no longer considered best practice.
MOISTURE AND HIDDEN CONDITIONS
Moisture intrusion can be intermittent or concealed. Hidden leaks, moisture damage, mold-like substances, or related deterioration may exist without visible evidence at the time of inspection. Moisture meters and thermal imaging, when used, are screening tools only and do not determine the full extent, source, or duration of a condition.
SPECIALISTS AND REPAIRS
When concerns are identified, repairs, maintenance, upgrades, monitoring, or further review may be recommended. References to contractors, specialists, trades, or qualified professionals within this report are intended as general guidance only and should not be interpreted as a definitive determination of who must perform the work. The appropriate professional may vary depending on the full scope of repairs ultimately required. Contractors frequently uncover additional deficiencies, damage, deterioration, or repair needs once materials are removed or systems are further investigated. Discovery of additional conditions during repair work should be considered normal and does not necessarily indicate those conditions were visible or readily accessible at the time of the inspection.
Contractors, specialists, engineers, and other qualified professionals may provide:
Repair recommendations
Scope of work
Cost estimates
Identification of concealed conditions
Design, engineering, or permitting requirements
SPECIALTY INSPECTIONS NOT INCLUDED
Unless specifically contracted as a separate service, this inspection does not include:
Mold or indoor air quality testing
Asbestos identification
Lead paint identification
Wood-destroying insect inspections
Sewer scope inspections
Environmental hazards
Geological or soil analysis
Well water quality testing
Underground utilities or piping
Solar energy systems
Security, communication, audio, or low-voltage systems
Determination of property boundaries, easements, or survey conditions
Thermal Imaging
An infrared camera was used selectively to examine specific areas of concern or to help validate suspected issues. Its use should not be interpreted as a comprehensive thermal survey of the entire structure. Deployment of the infrared camera was at my discretion to provide additional insight, and its application goes beyond the standard scope of a home inspection.
Temperature readings shown on thermal images are provided as a courtesy and should not be solely relied upon. They are intended as qualitative indicators rather than precise measurements, and actual temperatures may vary by +/- 2% or more. Some readings reflect surface temperatures only, and obtaining air or internal temperature measurements is beyond the scope of this inspection.
ONGOING MAINTENANCE
All homes require ongoing maintenance, including routine servicing, cleaning, sealing, adjustments, repairs, and monitoring throughout their service life.
How to Read this Report
- Note:Refers to aside information and /or any comments elaborating on descriptions of systems in the home or limitations to the home inspection. This section may include notes, recommendations, improvement suggestions, or statements based on modern standards.
- Conditions Requiring More Immediate Attention:
Address items that could incur substantial costs if not resolved promptly or that require immediate attention to prevent further damage or safety hazards. Non-functional components pose serious safety risks and may necessitate significant repairs or replacements. These issues require assessment and necessary actions by a qualified contractor before the end of your contingency period. - Moderate Repair And Maintenance Items:
Items identified with safety hazards or functional/installation deficiencies may have been operational at the time of inspection, but their functionality could be compromised. These defects often lead to further issues. Repairs or replacements are recommended for optimal performance and to prevent future problems before the end of your contingency period. Such items typically require attention from a qualified contractor or handyman and are not suitable for routine maintenance or DIY repairs. - Items Recommended For Improvement Or Maintenance:
This category encompasses items or components requiring minor repairs to enhance functionality, as well as those needing regular or basic maintenance. It also includes observations and recommendations for upgrades to specific items, areas, or components. - Conditions Warranting Safety Improvements:
The item, system, area, or component poses a safety concern that should be addressed promptly by a qualified professional. Identifying potential hazards is a key aspect of home inspection, as the inspector evaluates the property’s safety and highlights any risks affecting occupant well-being. - Future Maintenance - Aging:The item, system, or component was nearing, at, or past the end of its typical service life but may have been still functional to some degree at the time of inspection. Although aged components are not a deficiency in and of themselves, major repairs or replacements should be anticipated and planned for on any items that are designated as being at or past the end of their typical life. Depending on the item, these repair or replacement costs can represent a major expense, i.e., HVAC Systems, Water Heaters, Plumbing pipes, Aged wiring, electrical panels, etc.
- Conditions Needing Further Review:
During a home inspection, a home inspector may encounter issues or areas of concern that require further evaluation. In such cases, the home inspector may recommend that the buyer or homeowner seek further evaluation by a specialist. A specialist is an expert in a specific area related to home construction, repair, or maintenance.
📃 The Complete Inspection Report
Ch. 3 Grounds
3.1
3.2 Grounds Overview Photos
3.3 Driveways/Walkways/Patios
3.4 Grounds, Trees and Vegetation
3.5 Drainage and Site
3.6 Window and Stairwells
3.7 Retaining Walls
3.8 Fences
3.9 Outbuildings, Carports, Storage Sheds, Barns
Ch. 4 Exterior Siding, Doors and Windows
4.1
4.2 Exterior Overview Photos
4.3 Siding and Trim
4.4 Eaves, Overhangs, Soffits and Fascia
4.5 Exterior Doors
4.6 Exterior Window Frames
4.7 Exterior Vent and Exhaust Terminations
Ch. 5 Decks, Porches, Balconies and Exterior Stairs
5.1 Wood Decks Porches and Balconies
5.2 Concrete Decks, Stoops, Patios, Landings and Porches
5.3 Exterior Stairs
5.4 Water-Resistant Decks and Balconies
5.5 Metal Decks and Balconies
Ch. 6 Roof, Chimney and Gutters
6.1
6.2 Roof Overview Photos
6.3 Exterior Elevations and Roof Pitch
6.4 Roof Materials
6.5 Flashings, Valleys and Penetrations
6.6 Gutters and Downspouts
6.7 Chimneys
6.8 Skylights
Ch. 7 Garage
7.1 Garage Overview Photos
7.2 Garage General
7.3 Garage Fire Separation
7.4 Garage Doors and Automatic Openers
Ch. 8 Fuel Storage and Distribution
8.1 General Comments
8.2 Gas Meter
8.3 Gas, Propane and Oil Piping
8.4 Oil Storage
8.5 Propane Storage
Ch. 9 Electric Service
9.1
9.2 Electrical System Safety Overview
9.3 Electric Service Permits Found
9.4 Electric Service Voltage Tested
9.5 Electric Service
9.6 Electric Service Equipment
9.7 Sub Panel
9.9 Electrical Grounding System
9.10 Electrical Bonding System
Ch. 10 Electric Distribution and Finish Wiring
10.1 Branch Wiring
10.2 Receptacles and Fixtures
10.3 Ceiling Fans and Lighting
10.4 Smoke and Carbon Monoxide Alarm Systems
Ch. 11 Heating, Cooling, Fireplaces and Ventilation
11.1
11.2 Thermostat
11.3 Cooling Systems
11.4 Heating System
11.5 Air Filters
11.6 Vents and Flues
11.7 Heating and Cooling Distribution Systems
11.8 Mechanical Ventilation Systems
11.9 Fireplaces
11.10 Additional Heat Sources
Ch. 12 Plumbing
12.1
12.2 Water Meter
12.3 Water Service Supply
12.4 Distribution Pipe
12.5 Waste Pipe and Discharge
12.6 Water Heater
12.7 Water Temperature
12.9 Exterior Hose Bibs
Ch. 13 Additional Plumbing
13.1 Sump Pumps and Drains
13.2 Radon Equipment
13.3 Water Filters
13.4 Sewage Ejector Pumps
13.5 Central Vacuum
13.6 Fire Suppression
13.7 Irrigation
13.8 Spa
13.9 Water Features
13.10 Sauna
13.11 Swimming Pools
Ch. 14 Interior Living Area(s) and Bedrooms
14.1
14.2 Interior Overview Photos
14.3 Walls, Ceilings and Trim
14.4 Floors and Floor Materials
14.5 Interior Doors and Doorstops
14.6 Windows
14.7 Additional Interior Cabinets and Countertops
14.8 Wall Insulation and Air Bypass
14.9 Interior Stairs
14.10 Indoor Air Quality
Ch. 15 Kitchen
15.1
15.2 General Kitchen Pictures
15.3 Sinks and Faucets
15.4 Cabinets and Countertops
15.5 Disposers
15.6 Dishwasher
15.7 Ranges, Ovens and Cooktops
15.8 Refrigerators
15.9 Microwave
15.10 Kitchen Ventilation Method
15.11 General Appliances
Ch. 16 Laundry Facilities
16.1
16.2 Laundry Overview Photos
16.3 Washer
16.4 Dryer
16.5 Laundry Ventilation
Ch. 17 Bathroom Finishes
17.1
17.2 Bathroom Overview Photos
17.3 Sinks and Cabinets
17.4 Toilets
17.5 Bathtub / Shower / Bathtub Walls and Enclosures
17.6 Bathroom Ventilation
17.7 General Bathroom Finishes Condition
Ch. 18 Attic, Roof Structure and Ventilation
18.1
18.2 Attic Overview Photos
18.3 Attic Access
18.4 Roof Framing and Sheathing
18.5 Fire Separation
18.6 Attic Insulation
18.7 Attic and Roof Cavity Ventilation
Ch. 19 Foundation, Structure and Basement
19.1
19.2 Foundation
19.3 Floor, Wall and Ceiling Framing
19.4 Basement Overview Photos
19.5 Slabs and Concrete Floors
19.6 Basement Moisture
Ch. 23 Environmental Information
23.1 Moisture, Water Penetration and Active Leaks
23.2 Mold and Bio-Growth
23.3 Pest/Insects/Wildlife Concerns: WDI / Termite Information and Exclusions
Ch.1 General Comments
1.1 Building Characteristics, Conditions and Limitations
Style of Home: Traditional
Type of Building: Single Family (2-story)
Approximate Square Footage: 1343
Approximate Year of Original Construction: 1948
Number of Bedrooms: 3
Number of Bathrooms: 2
Attending the Inspection: Buyer
Occupancy: Unoccupied, but staged with furniture
Animals Present: No
Weather during the inspection: Partly cloudy
Approximate temperature during the inspection: Below 65[F]
Ground/Soil surface conditions: Damp
For the Purposes of This Report, the Front Door Faces: North
Map
Info and LMT's. Older Branch-Circuit Wiring Compatibility
Unless the electrical system has been fully updated, this building may contain branch-circuit wiring that predates modern 90°C-rated wiring standards. Older wiring methods—including early non-metallic cable (Romex), BX/AC cable, and knob-and-tube wiring where present—may have lower temperature ratings than many modern light fixtures, fans, and similar equipment.
When newer electrical devices are installed on older wiring systems, additional wiring modifications may be necessary to maintain compatibility with manufacturer installation requirements and modern electrical safety practices. These improvements commonly involve replacing short sections of wiring near the fixture and installing approved transition methods where appropriate.
If electrical upgrades or fixture replacements are planned, a licensed electrician should verify wiring compatibility and complete any necessary modifications.
Info and LMT's. Potential for Lead-Based Materials and Asbestos (Informational)
Based on the age of the home, materials that may contain lead or asbestos could be present. These materials were commonly used in residential construction prior to the late 1970s, and existing inventories continued to be installed into the early to mid-1980s. They may be present in components such as insulation, flooring, adhesives, siding, duct materials, or other building finishes.
Identification, sampling, or testing for lead, asbestos, or other environmental contaminants is outside the scope of this home inspection. Clients seeking confirmation should consult a qualified environmental testing laboratory or industrial hygienist before disturbing suspect materials.
Info and LMT's. Vacant homes present unique inspection limitations because many systems have not been subjected to regular use prior to inspection. While systems may function during testing, future performance cannot be predicted. Hidden leaks, drainage issues, fixture failures, and other conditions may only become apparent after normal occupancy resumes.
Pictures Showing the Direction the Front Door Faces
For the sake of this inspection, the front of the structure will be considered as the portion pictured in the above cover photo. References to the left or right of the structure should be construed as standing in the front yard, viewing the front of the structure.
Permit Note
In accordance with the Ohio Home Inspector Standards of Practice, obtaining or researching building permits is outside the scope of this home inspection. Clients are encouraged to verify permits, inspections, warranties, and other documentation for any additions, alterations, repairs, or improvements made to the property.
References to permits elsewhere in this report reflect only information that was voluntarily provided or readily available during the inspection and should not be considered a comprehensive permit search.
Structural Modifications / Additions Present
Portions of the home appear to have been modified, renovated, or expanded beyond the original construction. Examples may include additions, altered framing, removed or modified walls, reconfigured floor plans, or other structural changes. Determining whether these modifications were completed under permit, reviewed by an engineer, or approved by the local building authority is beyond the scope of a standard home inspection.
No determination is made regarding the design, engineering, permitting status, or code compliance of past construction activities. While no immediate concerns may be apparent in all modified areas, concealed deficiencies can exist where structural components have been altered. Buyers may wish to obtain available permits, plans, engineering documentation, or other records from the seller or local jurisdiction for additional information regarding the work performed.
Older Home Considerations
Homes of this age commonly differ from modern construction in their materials, design, and installation methods. Age-related settlement, irregular floors, older framing methods, and construction practices that differ from today's standards can often be expected without necessarily indicating a current structural deficiency. Recommendations throughout this report should be interpreted within the context of the home's age, visible condition, and performance at the time of the inspection.
Ch. 2 Appliance Disconnects and Utility Shutoffs
2.1 Shutoffs and Disconnects Noted
Picture Showing Main Electric Panel Disconnect at the Main Panel
The service disconnect, or main OCPD (overcurrent protection device), was reviewed for deficiencies and its location noted. This disconnect can be a breaker, fuse block, or kill switch, and it is the means of shutting off all electricity entering the home.
Missing Furnace Shutoff
A dedicated electrical disconnect for the furnace was not located. An accessible disconnecting means is an important safety feature that allows the equipment to be safely serviced and shut down when necessary. The absence of a readily accessible disconnect may complicate maintenance, emergency shutdown procedures, and future service work. This condition is not consistent with modern installation practices for permanently installed HVAC equipment.
Recommendations:
A licensed electrician or qualified HVAC contractor should correct this condition as recommended. Improvements may include installing a properly located and readily accessible disconnect in accordance with manufacturer specifications and modern safety practices. The scope of work may reasonably include reviewing the furnace electrical supply, overcurrent protection, and related service components where similar installation concerns may exist.
Ch. 3 Grounds
3.1
Per the Standards of Practice, the home inspector shall observe exterior electrical receptacles and the presence of GFCI protection (GFCI protection may not have been required on exterior receptacles when older homes were built, but upgrading is recommended for safety). The home inspector shall also observe decks, balconies, stoops, steps, areaways, porches, and applicable railings that are directly attached to the structure. Vegetation, grading, and drainage of the grounds, driveways, patios, walkways, and retaining walls will be inspected with respect to their effect on the condition of the structure.
The home inspector is not required to observe fences and gates, geological conditions, soil conditions, recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities), detached buildings or structures, or the presence or condition of buried fuel or waste storage tanks. The home inspector is also not required to move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstruct access or visibility.
3.2 Grounds Overview Photos
3.3 Driveways/Walkways/Patios
Driveway: Asphalt
Walkways: Concrete
Patios: Concrete
All readily accessible driveways, walkways, and flatwork areas were visually inspected through a representative sample of accessible surfaces for cracking, drainage concerns, settlement, trip hazards, slope, deterioration, surface wear, and vegetation-related conditions. No significant deficiencies were noted unless otherwise described within this section.
Driveway – Surface Deterioration
The driveway surface is deteriorating, with cracking, wear, and localized breakdown visible across multiple areas. Some of this reflects ordinary aging; however, freeze-thaw cycling and de-icing exposure typically accelerate deterioration once a surface begins breaking down, as moisture entering the damaged areas continues the process each winter. The rate of progression can vary with weather and de-icing practices, and a visual inspection cannot determine how the surface will perform in future seasons.
Recommendations:
A concrete or paving contractor should resurface the deteriorated sections and reseal the remainder of the driveway. Drainage across the whole surface should also be reviewed, since standing water is a common driver of this type of breakdown. Because deterioration of this kind tends to affect more than the worst-looking spot, the contractor should review adjoining sections during the same visit. Monitor the surface after repairs, particularly through the following winter, for continued cracking or breakdown.
Large Cracks in Flatwork
Cracks in the flatwork are wide enough to be more than cosmetic. Cracking at this width is typically related to settlement, soil movement, or frost heave beneath the slab rather than ordinary shrinkage as the concrete cured. Wider openings let more water reach the base, which can speed up widening and displacement, and a visual inspection cannot determine the condition of the soil or base beneath the slab.
Recommendations:
A concrete contractor should review the cracked sections, including the soil and drainage conditions beneath and around them, before choosing between routing and sealing, patching, slab stabilization, or replacement. The contractor should also inspect adjoining sections, since movement severe enough to cause wide cracking often affects more than one area. Downspout discharge and surface drainage near the flatwork should be corrected if they are contributing water to the base. Sealing alone is unlikely to hold if the underlying movement continues.
Tripping Hazard Present
Uneven surfaces and abrupt height changes are present in the flatwork, creating a trip hazard. Transitions like these are usually caused by settlement, frost heave, tree roots, or earlier patch repairs that did not stay level with the surrounding surface. These areas tend to keep shifting rather than stabilize on their own, and the hazard is greater in low light or when the surface is wet or icy.
Recommendations:
Each uneven transition should be corrected by a concrete contractor, using grinding, slab lifting, patching, or section replacement depending on the size of the offset. The contractor should also review the surrounding flatwork and nearby drainage, since settlement or water collecting beneath the slabs is often what caused the movement. Where roots or downspout discharge are contributing, those conditions should be addressed along with the surface repair so the correction holds.
Large Lip Between Driveway and Garage Slab
A noticeable height difference is present where the driveway meets the garage floor slab. This is usually caused by settlement or frost movement of the driveway or its base, since the driveway and garage floor are separate slabs that can move independently. The lip presents a trip hazard on foot, can catch lower vehicles or wheeled equipment, and may allow water to collect at the transition.
Recommendations:
This transition should be corrected by a concrete contractor, who can grind the higher edge, lift the lower slab, or replace the first section of driveway depending on the size of the offset. The contractor should also identify why the driveway moved, checking drainage at the garage entry, nearby downspout discharge, and the condition of the base. Any open joint at the transition should be sealed after the repair to keep water from undermining it again. Addressing the cause helps keep the lip from returning.
3.4 Grounds, Trees and Vegetation
Trees/Vegetation too near building: Yes-Vegetation, Yes-Trees
All readily accessible grounds, trees, vegetation, and site areas were visually inspected through a representative sample of accessible surfaces and conditions for grading concerns, drainage patterns, vegetation contact, erosion, settlement, moisture-related conditions, and general site performance. No significant deficiencies were noted unless otherwise described within this section.
Vegetation Too Close To Structure
Shrubs, vines, or other plantings are growing in direct contact with exterior wall surfaces at multiple locations. Sustained contact between vegetation and siding, trim, or foundation walls holds moisture against those materials, slows normal drying, and can conceal developing rot, insect activity, or pest access behind the growth. The condition of the wall surfaces behind the plantings could not be fully confirmed at the time of inspection.
Recommendations:
The plantings should be cut back or relocated to restore clearance from the exterior walls at each affected location. A landscaping contractor can handle larger shrubs or vines that have attached themselves to the siding. Once the walls are exposed, the siding, trim, and foundation areas that were covered should be checked for rot, staining, or signs of insect activity. Any damage found should be referred to a qualified contractor, and a licensed pest control professional should be consulted if insect activity is present.
Tree Overhanging Roof
Tree branches extend over the roof, with portions low enough to contact the roofing surface during wind or when weighted with snow or ice. Overhanging growth like this sheds leaves and debris directly onto the roof and into gutters, holds moisture against roofing materials, and gives squirrels and other wildlife an easy path onto the structure. Abrasion or wear on the roofing beneath the branches may not be fully visible from the vantage points available during the inspection.
Recommendations:
The overhanging limbs should be cut back by a qualified tree service to restore clearance above the roofline. Once the branches are removed, a roofing contractor should check the roofing where limbs were in contact for abrasion, granule loss, or damaged shingles. The gutters and downspouts beneath the canopy should be cleared and checked at the same time. Any limbs that appear dead, split, or diseased should be removed rather than simply shortened.
Soil Grade Too High
Soil and landscaping material are built up against the exterior wall in places, leaving little to no visible gap between the ground and the bottom edge of the siding or masonry veneer. That reduced clearance keeps the lower wall surface damp longer after rain and snowmelt, and over time can contribute to wood rot, insect entry points, or efflorescence at masonry, particularly through the freeze-thaw cycling typical of Central Ohio winters. Any damage at the base of the wall hidden beneath the soil could not be seen at the time of inspection.
Recommendations:
The affected areas should be regraded to pull soil away from the wall and re-establish clearance at the base of the siding, with the ground sloping away from the foundation. A landscaping or grading contractor can handle larger areas, particularly where soil must be removed rather than simply raked back. Once the base of the wall is exposed, the siding, trim, and sill area should be checked for softness, staining, or insect activity. Since Central Ohio winters bring repeated freeze-thaw cycling, restoring this gap now helps limit moisture-related wear at the wall base going forward.
Vegetation Too Close to Electric Service Drop
Tree branches or shrubbery are growing close enough to the overhead electric service drop to present a safety concern. Contact between vegetation and an energized conductor can wear through the wire's insulation, and during wind or ice loading, a branch pressing against the line can cause arcing, a service interruption, or in more severe cases a fire at the point of contact. The condition of the conductor insulation where the branches touch could not be confirmed from the ground.
Recommendations:
The utility provider should be contacted to report the vegetation contact and to arrange clearance work around the service drop. Trimming near an energized conductor should be performed by the utility or a qualified line-clearance tree contractor, often with the service temporarily disconnected, and not by a general landscaper or the homeowner. After clearance is restored, the conductor, the drip loop, and the attachment point at the house should be checked for insulation wear, scorching, or loose hardware. Any damage on the customer side of the connection should be referred to a licensed electrician.
Key Points:
- Contact with an energized conductor is a safety hazard regardless of how minor the contact currently appears.
3.5 Drainage and Site
Downspout Discharge Type: Below grade
Site Description: Flat
All readily accessible drainage and site conditions were visually inspected through a representative sample of accessible areas for grading, water management, drainage performance, erosion, settlement, runoff control, and moisture-related concerns. No significant deficiencies were noted unless otherwise described within this section.
The grounds in contact with the structure were inspected to determine that they were sloped to allow rainwater to drain away from the structure adequately. The soil is recommended to slope away from the foundation, with a 6-inch drop in elevation, in the first 10 feet away from the structure (5% grade). When the 5% grade cannot be achieved, swales or drains should be used as needed to properly divert and/or manage rainwater runoff. Any flat or low areas around the structure should be backfilled and sloped away from the foundation to prevent potential moisture infiltration into areas below grade (as applicable). No significant grading deficiencies were present at the time of inspection unless otherwise described within this section.
Info and LMT's. Info & LMT's – Site Grading, Drainage, and Underground Drainage Systems
Underground or concealed drainage components — subterranean pipes, footing drains, foundation drains, and other buried systems — could not be reviewed without excavation or specialized testing.
Grading and drainage performance was reviewed only from conditions visible at the time of inspection; heavy rainfall, frozen ground, or clogged gutters can affect performance differently at other times.
Review the Seller's Disclosure for any history of water intrusion or drainage work, and consult a drainage or waterproofing specialist if concerns exist.
Drainage & Roof Runoff Note
Roof runoff is directed away from the home through gutters, downspouts, and extensions where installed. Proper roof drainage and positive grading around the foundation are important components of long-term moisture management. As a general guideline, soil should slope away from the foundation approximately 6 inches within the first 10 feet where site conditions allow. Maintain gutters, downspouts, extensions, and surrounding grading, and periodically monitor these areas for changes that could allow water to collect near the foundation.
Downspout Discharge-Disconnected From Storm Drain
A downspout that is meant to connect to the underground storm drain system has come disconnected and is discharging water at the foundation instead. When this connection fails, the purpose of the underground system, carrying roof water well away from the house, is lost for that downspout. The water collects at the base of the wall, where it can contribute to erosion and below-grade moisture, and the open pipe can also take in soil and debris that may partially block the line.
Recommendations:
A qualified gutter or drainage contractor should reconnect the downspout to the storm drain line and secure the fitting so it cannot easily work loose again. Before reconnecting, the contractor should confirm the buried line is open and flowing, since debris may have entered through the open end. The soil and foundation near the disconnection should also be checked for erosion or signs of past water entry. Other downspout connections on the home should be checked at the same time.
Key Points:
- A disconnected downspout defeats the purpose of an underground storm drain system for that section of roof.
Flat Yard Grading Against Foundation
The ground where it meets the foundation is essentially flat rather than sloping away from the house. Current grading practice generally calls for about 6 inches of fall within the first 10 feet from the foundation, and without that slope, rainwater has little reason to move away and tends to linger where it lands. Water that sits near the foundation soaks into the soil against the wall, which over time can contribute to basement or crawlspace moisture.
Recommendations:
A qualified grading or landscaping contractor should build up the grade near the foundation and taper it down over the first several feet to establish the slope that is currently missing. The new soil should be compacted and kept several inches below siding, trim, and any brick weep holes. The contractor should also check the rest of the foundation perimeter for similar flat or low areas and confirm downspouts discharge onto ground that slopes away. Correcting the whole perimeter at once avoids simply moving the water to another side of the house.
Key Points:
- About 6 inches of fall within the first 10 feet is the general benchmark for adequate slope away from a foundation.
- Flat grading does not actively push water toward the house the way negative grading does, but it does not help move it away either.
3.6 Window and Stairwells
Window Well or Basement Wells: Present
All readily accessible window wells were visually inspected through a representative sample of accessible areas for drainage, size and clearance, general condition, debris accumulation, covers or grates, safety features, sealing, and accessibility. No reportable deficiencies were visibly present at the time of inspection unless otherwise noted within this report.
Debris in the window wells prevented confirmation of whether drainage provisions, such as a gravel base or drain, are present. No signs of moisture intrusion were observed inside the home at the time of the inspection, but the ability of the wells to drain could not be determined while the debris remained. I recommend having the wells cleaned out and then checking them during or after a heavy rain, with a drainage contractor consulted if water collects.
Window Well Full of Organic Debris
This window well is filled with a heavy accumulation of leaves, soil, and other organic material. Decaying debris at this depth holds moisture against the basement window frame and foundation, can bury or clog the drain beneath it, and provides shelter for insects and rodents looking for a way into the home. No signs of moisture intrusion were observed inside the home at the time of the inspection, but the amount of material suggests it has been building up for several seasons, and it may be concealing damage to the window frame or well liner that could not be seen.
Recommendations:
The well should be fully cleaned out, removing all leaves, soil, and decayed material down to the gravel base or drain. Once it is cleared, the drain, if present, should be flushed with a hose to confirm water flows away, and the window frame, sill, glazing, and well liner should be checked for rot, rust, or damage that the debris may have been hiding. If the drain does not flow or damage is found, a qualified contractor should be brought in to restore the drainage or repair the window. Keeping the well on a spring and fall cleaning schedule, or adding a fitted cover, is recommended to prevent the same buildup from returning.
Missing Window Well Covers
Covers are not installed on one or more window wells around the home. Open wells collect leaves, snow, windblown debris, and rainwater that would otherwise be shed away, and over time that material clogs whatever drainage the wells have and holds moisture against the basement windows. No pest activity or moisture intrusion was observed at the time of the inspection, and covers are not required on every well, but installing them is a practical way to reduce debris and water buildup and to keep people and pets from stepping into an open well.
Recommendations:
Properly sized covers should be installed on the open window wells, selected to fit each well's shape and dimensions and secured so they will not blow off in high wind. Where a well serves an emergency escape window, the cover should be one that can be opened or pushed off easily from inside the well without tools, and no cover should be relied on to support a person's weight unless it is rated for that load. Before the covers go on, each well should be cleaned out and its drain, if present, checked to confirm it is working, since a cover over a clogged well does not solve the underlying drainage problem. Periodic checks after storms are recommended to confirm the covers remain in place.
3.7 Retaining Walls
Retaining Wall Materials if Applicable: Not Present
3.8 Fences
Fencing Present: Present
Info and LMT's. The property includes a fencing system. Fencing is not a required component of a home inspection under the applicable Standards of Practice, and it was not inspected in detail. Any comments provided about the fence are cursory observations offered as a courtesy and should not be relied upon as a full review of its condition, safety, or suitability. If the fence is important to your use of the property, such as for pet containment, privacy, or a pool barrier, I recommend reviewing it yourself or having a qualified fencing contractor review it before relying on it for those purposes.
3.9 Outbuildings, Carports, Storage Sheds, Barns
Outbuilding Style if Applicable: Not Present
Ch. 4 Exterior Siding, Doors and Windows
4.1
Per the Standards of Practice, the home inspector shall observe from ground level: - Wall cladding, flashings, and trim; entryway doors and a representative number of windows; eaves, soffits, and fascias. The home inspector shall: Describe wall cladding materials, Operate all entryway doors and a representative number of windows, and probe exterior wood components where deterioration or damage is suspected.
The home inspector is not required to observe: Storm windows, storm doors, screening/screens, shutters, awnings, and similar seasonal accessories; the Presence of safety glazing in doors and windows; Detached buildings or structures; or the Presence or condition of buried fuel storage tanks, water tanks, or septic tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstruct access or visibility.
4.2 Exterior Overview Photos
General Elevations. The photos in this section provide representative views of the home’s exterior conditions as visible at the time of inspection.
Info and LMT's. This section provides representative views of the home’s exterior elevations as seen from the ground at the time of inspection. These photos are intended to document overall exterior conditions, including siding, trim, eaves, soffits, fascia, windows, doors, and visible exterior penetrations. Conditions not visible due to height, angle, finishes, weather, or obstructions may not be fully captured.
A home inspection entails a visual inspection of the accessible exterior components of the property that are readily accessible able and available. It does not encompass a thorough evaluation of concealed elements, nor does it consider weather-related influences, concealed damages, or inaccessible areas.
4.3 Siding and Trim
Trim Material: Aluminum, Wood
Siding Material: Vinyl
The wall cladding and trim were inspected in representative areas for significant damage, proper flashing details, and potential moisture intrusion points. No significant deficiencies were noted unless otherwise described within this section.
Info and LMT's. All visible sections of the flashings were examined for any notable deficiencies, including Z-flashings, drip caps, etc., where relevant. Given that flashings are often concealed by wall claddings, their functionality is assessed by checking for signs of moisture intrusion or damage in areas where they are expected to be present.
Warped Siding
Portions of the exterior siding appear warped, bowed, or uneven. Warping of siding materials can occur from prolonged moisture exposure, improper installation, thermal movement, aging, or material deterioration. Distorted siding may allow gaps or openings that reduce the effectiveness of the exterior cladding system and may contribute to moisture intrusion or accelerated deterioration of underlying materials over time.
Recommendations
A qualified siding contractor or exterior contractor should perform corrective work as recommended. Repairs may reasonably include securing or replacing warped siding materials, addressing installation deficiencies, improving moisture-management details, and reviewing adjacent siding and wall components where similar conditions or concealed deterioration may exist.
Key Points:
- Prolonged siding movement may contribute to concealed wall deterioration
Loose Exterior Siding
Portions of the exterior siding are loose, detached, or not securely fastened. Loose siding can allow wind-driven rain, moisture, air intrusion, and pests to enter behind the exterior cladding system, which may contribute to concealed deterioration of wall materials over time and reduce the overall effectiveness of the exterior weather barrier.
Recommendations:
A qualified siding contractor or exterior contractor should perform corrective work as recommended. Repairs may reasonably include securing or replacing loose siding materials, improving fastening methods, sealing vulnerable areas, and reviewing adjacent siding sections and related wall components where similar installation or moisture-related conditions may exist.
Key Points:
- Concealed wall deterioration can develop if moisture intrusion continues
Inadequate Exterior Caulking
Exterior caulking is missing, cracked, or deteriorated at joints, seams, and material transitions. Failed or incomplete sealant at these locations can allow water intrusion behind exterior coverings, potentially contributing to concealed moisture damage, deterioration of building materials, or organic growth over time.
Recommendations:
A qualified contractor should complete corrective sealing as recommended. The scope of work may reasonably include removing failed caulking, preparing affected surfaces, installing appropriate exterior-grade sealant compatible with adjacent materials, and addressing similar joints or transitions where comparable conditions may exist to help support long-term moisture resistance.
Key Points:
- Exterior sealant requires periodic maintenance and replacement as part of normal upkeep
Blistering/Peeling Paint
Blistering and peeling paint are present on portions of the exterior. Once the finish fails like this, underlying materials are exposed to more moisture than they're built to handle, which can speed up deterioration and lead to ongoing upkeep if it's not corrected.
Recommendations:
Have a qualified contractor complete repairs and repainting of the affected surfaces. That should include proper surface prep, sealing any exposed material, and a look at nearby areas where similar moisture-driven failure could be developing.
Key Points:
- Exposed materials may absorb moisture more easily over time
- Peeling paint reduces protection against weather exposure
Note:
- If there are signs of moisture getting in, it may also be wise to consult a general contractor or waterproofing specialist before repainting to make sure any deeper issues are addressed first.
Damaged Exterior Trim
Sections of the exterior trim are damaged, deteriorated, split, loose, or otherwise compromised. Exterior trim serves an important role in protecting edges, joints, and transitions within the exterior wall assembly while also helping direct water away from underlying materials. Damaged trim can allow moisture intrusion behind exterior finishes and may contribute to concealed deterioration of siding, sheathing, framing, or related components over time if repairs are not completed.
Recommendations:
A qualified exterior contractor or carpentry professional should perform repairs as recommended. The scope of work may reasonably include removal and replacement of damaged trim materials, correction of moisture-entry points, and review of adjacent siding, sheathing, or concealed wall components where related deterioration may be present.
Gaps or Spaces in Exterior Materials
Gaps or separations are present at sections of the exterior materials, including siding, trim, or related components. Open joints can allow moisture intrusion, air leakage, and potential pest entry. Over time, these conditions may contribute to concealed deterioration of underlying materials if not addressed.
Recommendations:
I would have a qualified exterior contractor provide appropriate repairs and sealing as recommended. Improvements may reasonably include sealing joints, repairing or replacing affected components, and addressing adjacent areas where similar conditions may exist to support effective moisture management consistent with manufacturer specifications and modern construction practices.
Key Points:
- Moisture intrusion may contribute to concealed deterioration over time
4.4 Eaves, Overhangs, Soffits and Fascia
Eaves Materials: Aluminum
The roof overhangs were inspected at representative visible portions for signs of water damage, deterioration, and other significant defects. No significant deficiencies were noted unless otherwise described within this section. Concealed damage may exist at structures where fascia and/or soffit coverings are clad with vinyl or aluminum materials, as these finishes can limit visibility of underlying components.
Garage Awning / Overhang – General Conditions
An awning / overhang is attached to the garage. Various conditions may be present at this type of exterior assembly, including aging or deteriorated materials, loose or questionable connections, improper or limited flashing, damaged roofing components, inadequate drainage, and/or repairs or modifications completed over time. Because the assembly is exposed to weather and transfers loads back to the garage structure, continued deterioration or inadequate attachment can contribute to leakage, wood damage, movement, or eventual failure of portions of the assembly.
Recommendations
Have a qualified contractor evaluate the awning / overhang as a complete assembly and make repairs or improvements as needed. This should include the roofing and flashing, supporting framing, attachment points, fasteners, drainage, and any concealed areas that become accessible during repairs. Damaged or deteriorated materials should be repaired or replaced, and the completed assembly should be securely supported, properly weather-resistant, and capable of directing water away from the garage.
Key Points
- Evaluate the complete awning / overhang rather than individual visible defects only.
- Repair deteriorated materials, questionable connections, flashing, roofing, and drainage conditions as needed.
- Additional concealed damage may become apparent once repairs are underway
4.5 Exterior Doors
Exterior Door Styles: Solid core
All exterior doors were inspected in representative visible areas for damage, operational deficiencies, flashing concerns, and other significant conditions. No significant deficiencies were noted unless otherwise described within this section.
Info and LMT's. Handlesets, including deadbolts and door handles, are not assessed for functionality with keys during the inspection. It is advisable to consider replacing or re-keying any deadbolts and handles due to uncertainty regarding who may have access to keys for the residence. Consequently, deadbolts and handles will be evaluated solely based on their alignment with the door, focusing on any issues preventing proper latching or locking.
Damaged Finish at Exterior Door
The exterior door has damaged, worn, or deteriorating finish coatings. When protective finishes break down, exposed wood or door materials become more vulnerable to moisture absorption, weathering, UV exposure, swelling, and premature deterioration over time. Continued exposure without maintenance may reduce the long-term durability and weather resistance of the door assembly.
Recommendations:
Have a qualified painter, handyman, or appropriate contractor perform corrective work as recommended. Repairs may reasonably include surface preparation, sanding, sealing exposed materials, refinishing the door assembly, and reviewing adjacent trim or door components where similar weather-related deterioration may exist to help restore long-term durability and weather resistance.
Key Points:
- Worn finishes can expose door materials to moisture and weather damage
4.6 Exterior Window Frames
Window Frames: Vinyl
The exterior components of the windows, including representative visible portions of trim, flashing, sealants, and related assemblies, were inspected for significant damage, improper flashing details, clearance concerns, and other visible deficiencies. No significant deficiencies were noted unless otherwise described within this section. Routine monitoring and maintenance of these areas is recommended to help reduce the likelihood of future moisture intrusion, deterioration, or pest-related concerns over time.
4.7 Exterior Vent and Exhaust Terminations
Vent Types: Present, HVAC, Dryer Exhaust
The exterior penetrations were visually inspected in representative accessible areas for proper sealing, flashing, clearances, and signs of damage or deterioration. No significant deficiencies were noted unless otherwise described within this section. Ongoing monitoring and routine maintenance of exterior penetrations is recommended to help reduce the likelihood of moisture intrusion, air leakage, or pest entry over time.
Info and LMT’s – Concealed Vent Terminations and Connections. Vent terminations and duct connections located within sealed walls, ceilings, or other concealed areas could not be confirmed. The inspection is limited to visible and readily accessible components, and the continuity, routing, and final termination points of concealed ductwork are not fully verifiable. As a result, conditions such as disconnected ducts, improper terminations, or concealed damage may exist but are not detectable within the scope of a visual inspection. Inquire with the seller regarding any known issues, prior modifications, or available documentation related to the installation and routing of ventilation systems.
Ch. 5 Decks, Porches, Balconies and Exterior Stairs
5.1 Wood Decks Porches and Balconies
Wooden Decks, Porches or Balconies Present: Not Present
5.2 Concrete Decks, Stoops, Patios, Landings and Porches
Concrete Structure: Present
The concrete decks, stoops, landings, and porches were inspected in representative visible areas for significant damage, cracking, improper slope, flashing concerns, potential moisture entry points, and overall structural integrity. No significant deficiencies were noted unless otherwise described within this section.
Concrete Porch – Minor Cracking Present
Minor cracking is present at the concrete porch. Small cracks are common in concrete due to shrinkage, settlement, seasonal movement, and normal aging. While the cracking appears limited at this time, openings in concrete can allow moisture penetration, which may contribute to additional deterioration over time, particularly in climates subject to freeze-thaw conditions.
Recommendations:
Have a qualified concrete contractor repair and seal the cracks as recommended. Corrective work may reasonably include assessing drainage conditions, settlement patterns, and adjacent concrete surfaces where similar cracking may be present to help reduce the potential for continued deterioration.
Key Points:
- Open cracks can allow moisture intrusion and freeze-thaw damage.
- Early maintenance may help reduce future deterioration.
5.3 Exterior Stairs
Exterior Stairs If Applicable: Present
The representative visible components of the exterior stair system were inspected by traversing the stairs, where possible, to evaluate their general condition, stability, handrails, guards (where applicable), and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Handrail Not Required.
A handrail was not present at the stairway, which is acceptable as the stairway does not exceed the minimum height or number of risers requiring a handrail. Under modern standards, a handrail is typically required when there are four or more risers or when the total rise exceeds 30 inches. No correction is necessary.
Non-Uniform Stair Riser Heights
The stair risers are not uniform in height. Inconsistent stair geometry can increase the likelihood of trips and falls because users typically navigate stairs based on rhythm and expectation. Even relatively small variations in riser height can create a safety concern, particularly during descent or in lower lighting conditions.
Recommendations:
Have a qualified contractor perform corrective work as recommended to improve riser consistency and overall stair safety. Repairs may reasonably include modifying stair framing, tread-to-riser relationships, finished surfaces, support components, and adjacent stair details as needed to help provide more uniform stair dimensions and safer long-term performance.
5.4 Water-Resistant Decks and Balconies
Not Present
5.5 Metal Decks and Balconies
Not Present
Ch. 6 Roof, Chimney and Gutters
6.1
Per the Standards of Practice, the home inspector shall observe: The roof covering, roof drainage systems, visible flashings, skylights, chimneys, and roof penetrations and report signs of leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials and Report the method used to observe the roofing.
The home inspector is not required to: Walk on the roofing (although every safe attempt to do so will be taken), report on the age or remaining life of the roof covering, or move leaves, snow, or other items on the surface that may block visual accessibility, or observe attached accessories including but not limited to solar systems, antennae, satellite dishes, and lightning arrestors. No claims will be made as to the remaining roof material life expectancy, and no guarantee or warranty should be expected from comments or observations. The sellers or the occupants of a residence will generally have the most relevant knowledge of the roof and of its history. Therefore, I recommend that you consult with the sellers about the age of the roof covering and that you either include comprehensive roof coverage in your home insurance policy or obtain a roof certification from an established local roofing company.
6.2 Roof Overview Photos
Info and LMT's. The examination of the roof and its covering material is confined to the conditions observed on the day of inspection exclusively. The assessment includes inspecting the roof covering material, visible sections of the roof structure within the attic (if accessible), and interior ceilings to identify any signs of existing or previous leaks. It's important to note that leaks may become apparent in the future or during adverse weather conditions that were not evident during the inspection.
Any deficiencies documented in this report regarding the roof covering or signs of past or present leaks should be addressed promptly by a licensed roofing contractor. They should be evaluated and remedied as necessary to ensure the integrity of the roof and prevent potential damage.
6.3 Exterior Elevations and Roof Pitch
5/12, 4/12
6.4 Roof Materials
Method of Roof Inspection: Viewed with a drone
Roof Covering Materials: Asphalt shingle, Architectural grade composition shingle
Roof Style: Gable
Overlay Roof: Unknown
Shingle Fastening Accessible For Inspection: No
Percentage of Roof that could be Safely Traversed: 0%
Approximate Age of Roof Covering: 2-5 Years
A representative sample of visible components of the roofing system were inspected for significant defects related to roofing materials, roof structure, flashing details, gutters, downspouts, ventilation components, roof penetrations, and debris conditions. No significant deficiencies were noted unless otherwise described within this section.
Info and LMT's. This inspection of the roof covering is visual only, from the vantage points accessible at the time (ground, ladder, walked roof surface, or aerial imagery, as noted elsewhere in this section). Concealed components, areas hidden by weather conditions, and portions not visible from the inspection method used could not be evaluated. The inspection is intended to determine general condition only; it does not establish, and cannot guarantee, the roof's remaining service life.
Info and LMT's. Portions of the roof were evaluated using an aerial drone rather than by walking the surface or viewing from a ladder. For those specific portions, observations are limited to what is visible from the drone's aerial perspective, which provides a less thorough view than direct access would.
Info and LMT's. The roofing materials and condition of the existing roof made it difficult to visually confirm whether an overlay (multiple layers of roofing) is present.
Info and LMT's. Shingles in this area were well-bonded and could not be lifted to inspect the fastening pattern underneath without a pry bar, which is not used as part of a standard visual inspection. Well-bonded shingles are themselves a good sign, since loose or unbonded shingles are more prone to wind damage and would be noted as a defect.
Info and LMT's. The roof age noted below is a rough estimate based on general observations and industry standards, not official records, and actual remaining lifespan will vary with maintenance history, climate, and material quality.
Granule Loss
Granule loss is present on portions of the asphalt shingle roof covering. Protective granules help shield shingles from ultraviolet exposure, weathering, and normal aging. As granules wear away, shingles become more susceptible to accelerated deterioration, cracking, and a reduced service life.
Recommendations:
Continue routine roof maintenance by periodically monitoring the affected areas for accelerated wear, exposed asphalt, curling, cracking, or damaged shingles. Repair or replace shingles as needed to maintain the roof covering. If granule loss becomes widespread or significant deterioration is observed, have a qualified roofing contractor evaluate the roof and complete appropriate repairs or recommend replacement as warranted.
Key Points:
- Continued wear can lead to premature roof deterioration and future repairs
6.5 Flashings, Valleys and Penetrations
Flashing Styles and Roof Penetrations: Metal Flashing, Plumbing Stack Vent, HVAC/Furnace
Representative visible roof flashing components were inspected for conditions commonly associated with proper water management at roof transitions, penetrations, terminations, and directional changes in the roofing system. Roof flashings are intended to help direct water away from vulnerable areas where roofing materials start, stop, intersect, or are penetrated. The inspection included reviewing flashing methods and conditions that are generally considered standard or commonly accepted for this region and type of construction. Damaged, incomplete, deteriorated, or non-standard flashing details may indicate an older or potentially less reliable roofing assembly and can increase the likelihood of moisture intrusion over time. Any reportable flashing deficiencies identified in the representative visible areas inspected are documented below where applicable.
Representative visible portions of the roof flashings were inspected for significant deficiencies at applicable flashing locations, including drip edge, sidewall, headwall, counter flashing, step flashing, and similar components. Many flashing components are concealed beneath roofing materials and/or wall claddings and are not directly visible during a standard visual inspection; therefore, concealed portions are excluded from this inspection. Flashing performance is assessed primarily through visible conditions and by reviewing accessible interior ceilings, attic spaces, and roof decking for signs of moisture intrusion where flashing components are presumed to be present. No reportable deficiencies were visibly present at the representative visible portions inspected unless otherwise described within this section.
Representative visible portions of the roof protrusions and penetrations were inspected for significant defects, including signs of deterioration, improper sealing, flashing concerns, and visible moisture intrusion conditions. Roof protrusions were also reviewed from accessible attic areas, where possible, for visible signs of leakage or moisture-related staining at associated roof penetrations. No significant deficiencies were noted unless otherwise described within this section.
Damaged Plumbing Vent Stack
The plumbing vent stack at the roof is damaged. A compromised vent stack can affect proper drainage and venting of the plumbing system, contribute to sewer gas odors inside the home, and increase the risk of water intrusion at the roof penetration if it is not properly sealed.
Recommendations:
Have a licensed plumbing contractor repair or replace the damaged vent as needed, in accordance with manufacturer's specifications and modern plumbing standards. Work may reasonably include ensuring the vent is properly sealed at the roof penetration and coordinated with a qualified roofing contractor if flashing or sealing components are involved.
Key Points:
- The vent stack shows damage at the roof penetration.
- Damage can affect plumbing system venting and may allow sewer gas odors or water intrusion.
- Repair should involve a licensed plumber, coordinated with a roofing contractor for resealing the penetration.
6.6 Gutters and Downspouts
Gutter and Downspout Materials: Aluminum
Representative visible portions of the gutters and downspouts were inspected for significant deficiencies related to securement, debris accumulation, standing water, drainage performance, damage, and general condition. Active leakage conditions cannot always be confirmed unless rainfall is occurring at the time of inspection, and minor seepage at seams, joints, or end caps may develop over time due to seasonal movement, aging sealants, or debris buildup. If leakage becomes apparent after occupancy, maintenance, sealing, or localized repairs may be needed. No significant deficiencies were noted unless otherwise described within this section.
Gutter Debris / Cleaning Needed
Organic debris is present within portions of the gutter system. Accumulated leaves, sediment, and other debris can restrict proper roof runoff and reduce the system’s ability to effectively direct water away from the structure. Overflow conditions may contribute to fascia deterioration, siding staining, moisture intrusion, soil erosion, or foundation-related moisture concerns over time, particularly during heavier rainfall or seasonal freeze/thaw conditions common in this region.
Recommendations:
Have the gutters professionally cleaned and maintained as recommended. Corrective work may reasonably include removing debris, confirming gutters are unobstructed and properly sloped, checking for leakage or loose sections, and assessing adjacent downspouts and discharge areas where similar buildup or drainage concerns may exist to help support effective long-term water management.
Note:
- This is routine house maintenance; I would expect the need to clean gutters and downspouts regularly.
Loose/Disconnected Gutter Spikes
Several gutter spikes are loose or disconnected, allowing portions of the gutter system to pull away from the fascia. Gutters that are not securely attached may not properly collect and direct roof runoff, increasing the potential for overflow, moisture intrusion, wood deterioration, staining, and damage to adjacent exterior components. Continued movement can also place additional stress on the gutter system and supporting materials.
Recommendations:
Have a qualified contractor perform corrective work as recommended. The scope of work may reasonably include securing loose gutter sections, replacing failed fasteners, installing modern fastening methods where appropriate, and assessing adjacent gutter components, fascia materials, and support locations where similar conditions may exist.
6.7 Chimneys
Chimneys Present: Present
Chimney Material: Masonry
Chimney Flue Liners: Not visible
Representative visible portions of the chimney system were inspected for significant deficiencies related to structural integrity, accessible flue liner conditions, clearances, chimney cap installation, masonry and mortar condition, accessible damper operation, and visible creosote buildup. Portions of chimney systems, including concealed flue components and internal areas not readily accessible, are excluded from a standard visual inspection. No significant deficiencies were noted unless otherwise described within this section.
NFPA-Recommended Chimney Inspection Guidance
The NFPA (National Fire Protection Association) recommends an annual inspection of all chimneys, fireplaces, solid fuel-burning appliances, and vents. They also recommend an NFPA 211 Standard, Level II inspection upon sale or transfer of the property. A Level II inspection includes, not only cleaning the interior of the chimney pipe, but also the use of specialized tools and testing procedures such as video cameras, etc. to thoroughly evaluate the serviceability of the entire flue lining and fireplace/chimney system. Level II inspections are not always needed, especially for short simple flues that can be inspected visually after a cleaning. If a chimney cleaning has not been performed over the past 12 months, such an inspection is recommended before the home changes ownership---for fire safety reasons. Implement any repairs as recommended.
Concrete Chimney Cap – Inadequate Overhang
The concrete chimney cap does not extend sufficiently beyond the masonry. Caps with minimal or no overhang provide limited protection from rainwater runoff, which can allow moisture to enter the chimney structure and contribute to masonry deterioration over time.
Recommendations:
Have this masonry chimney repaired or improved by a qualified mason or chimney professional. Repairs should include installing or modifying the chimney cap to provide proper overhang and drip edges consistent with modern masonry practices. Corrective work may reasonably include reviewing adjacent chimney components to ensure the assembly sheds water as intended.
Key Points:
- Minimal overhang allows rainwater to run down the sides of the chimney instead of dripping clear
- Continued moisture exposure can accelerate masonry deterioration and mortar loss
- Drip edges/kerfs help direct water away from the masonry face
Brick Chimney – Missing Mortar
The brick chimney has areas where mortar is missing or deteriorated. Open or eroded mortar joints can allow water intrusion into the chimney structure, contribute to accelerated brick deterioration, and reduce the long-term durability and stability of the masonry assembly.
Recommendations:
Have a qualified masonry contractor complete corrective repairs as recommended. The scope of work may reasonably include repointing deteriorated mortar joints, replacing damaged masonry materials where needed, and addressing adjacent chimney areas where similar weather-related deterioration may exist.
Key Points:
- Open or eroded mortar joints allow water intrusion into the chimney structure
- Continued moisture exposure accelerates brick deterioration and can loosen individual bricks over time
- Repointing with matching mortar helps restore both appearance and structural performance
6.8 Skylights
Skylights if Applicable: Not Present
Ch. 7 Garage
7.1 Garage Overview Photos
7.2 Garage General
Garage Type: Detached
7.3 Garage Fire Separation
Garage Occupant Door: Not Applicable
7.4 Garage Doors and Automatic Openers
Overhead Garage Door Type: Metal
Automatic Garage Opener: Present
The representative visible garage door system, including the door panels, rollers, tracks, brackets, and springs, was inspected for significant damage, loose components, and operational concerns. No significant deficiencies were identified unless otherwise noted within this section.
The representative visible garage door(s) were operated using the wall-mounted control and inspected for proper operation, significant damage, and installation-related deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Ch. 8 Fuel Storage and Distribution
8.1 General Comments
Fuel Sources Present if Applicable: Fuel Sources Present
8.2 Gas Meter
Gas Meter Present: Present
Gas Pipe Materials: Steel and flex pipe
Gas meter present and located on the side of structure
The representative visible gas meter and associated components were inspected for significant damage, improper installation, gas leakage indicators, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Vegetation Too Close to Gas Meter
Vegetation is present too close to the gas meter and associated piping. Overgrowth can restrict access for servicing, inspection, maintenance, and emergency shutoff operations. Vegetation may also contribute to moisture retention against metal components, potentially accelerating corrosion or concealing developing concerns.
Recommendations:
Trim or remove vegetation around the gas meter and associated piping as recommended. Corrective work may reasonably include establishing and maintaining adequate clearance, improving visibility of utility equipment, and reviewing adjacent areas where similar overgrowth may interfere with access, maintenance, or safe operation.
Key Points:
- Overgrowth can restrict access to the gas meter and shutoff valve
8.3 Gas, Propane and Oil Piping
Gas Piping Materials Noted: Steel
The representative visible gas distribution piping was inspected for significant damage, corrosion, inadequate support, improper materials, and evidence of gas leakage. No significant deficiencies were identified unless otherwise noted within this section.
Abandoned Gas Line Present
An abandoned gas line was noted. The line appears to have been previously disconnected and capped, and no gas odor was detected at the time of the inspection. Abandoned gas lines are sometimes left in place after appliances are removed or systems are modified. Properly capped lines are commonly acceptable; however, any unused gas piping should remain securely capped and protected to help prevent future leakage or damage.
Gas Piping – Missing Protective Coating
Portions of the exterior gas piping are missing protective rust-inhibiting coating or paint. Exposed metal gas piping is more vulnerable to corrosion when subjected to weather exposure and seasonal moisture conditions. Continued deterioration over time may affect the long-term condition and serviceability of the piping system.
Recommendations:
Have a qualified plumbing contractor or gas utility contractor perform corrective work as recommended. Repairs may reasonably include cleaning corroded surfaces, applying approved rust-inhibiting coating or paint, and assessing adjacent exposed gas piping components where similar corrosion conditions may exist.
Key Points:
- Exterior gas piping is vulnerable to corrosion when protective coatings deteriorate
- Rust-inhibiting coatings help support longer-term durability of exposed metal piping
8.4 Oil Storage
Oil Storage if Applicable: Not Present
8.5 Propane Storage
Propane If Applicable: Not Present
Ch. 9 Electric Service
9.1
Per the Standards of Practice, the home inspector shall observe Service entrance conductors; Service equipment, grounding equipment, the main overcurrent device, main and distribution panels; Amperage and voltage ratings of the service (if the conductors' sizing text is present/legible); Branch circuit conductors, their overcurrent devices, and the compatibility of their ampacities and voltages. The home inspector shall describe Service amperage and voltage (if known), Service entry conductor materials, Service type as being overhead or underground, and the location of main and distribution panels. The home inspector shall report on: the presence of any observed aluminum branch circuit wiring.
The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over-current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Motion or Dusk to Dawn lighting, Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system.
9.2 Electrical System Safety Overview
Link to NEC: Link To Code
9.3 Electric Service Permits Found
Permits Stickers Found: No Permits Found
9.4 Electric Service Voltage Tested
Service Voltage: 120/240
Info and LMT's. Service amperage is determined by examining the size and rating of the service entrance conductors and the main service disconnect.
Standard residential service voltage (120/240VAC) is treated as the operating voltage for this type of installation unless something in the panel or service equipment indicates otherwise; a voltage meter reading is not part of this evaluation. Where the service entrance conductor sizing isn't legible or marked, the stated amperage is listed as an estimate based on the visible equipment rather than a confirmed value.
9.5 Electric Service
Service Entrance: Above Ground
Meter Base Amperage: 200
Power was supplied to the home by an overhead electrical service. The representative visible components of the electrical service entrance, including the service drop, service mast, and electric meter, were inspected for significant defects related to damage, improper installation, and other readily visible safety hazards. No significant deficiencies were identified unless otherwise noted within this section.
Weather Head - Missing Cap
The electrical service mast is missing a proper weatherhead (mast-top cap). A weatherhead is intended to help prevent rainwater from entering the service mast and contacting the service entrance conductors. Missing protection may allow moisture intrusion, which can contribute to corrosion, insulation deterioration, electrical faults, and reduced long-term reliability of the service equipment.
Recommendations:
Have a qualified electrician perform corrective work as recommended. The scope of work may reasonably include installing an approved weatherhead, verifying proper conductor drip loops, inspecting the service mast and service entrance conductors for moisture-related deterioration, and correcting any related deficiencies necessary to help ensure the electrical service is adequately protected from weather exposure.
Key Points:
- Moisture intrusion may contribute to corrosion, insulation deterioration, and electrical faults.
Missing Drip Loop at Electrical Service
The electrical service conductors do not appear to include a proper drip loop at the service entry connection. Drip loops are intended to help direct rainwater away from the service mast and electrical entry components before water can follow the conductors into the electrical system. Without an adequate drip loop, moisture intrusion may occur at or near the service connection, potentially contributing to corrosion, deterioration, electrical faults, or other safety-related concerns over time. Portions of the service connection may not have been fully visible.
Recommendations:
Have a licensed electrician complete recommended corrective work to provide a proper drip loop configuration at the electrical service conductors. Corrective work may reasonably include adjusting service conductor routing, improving weather protection at the service entry, and assessing related electrical components where similar moisture exposure or installation concerns may exist to support safe and reliable long-term performance consistent with modern electrical practices.
9.6 Electric Service Equipment
Main Electric Panel Location: Basement
Panel Manufacturer: Cutler Hammer
Main Panel Amperage: 100 amps
The representative visible components of the main electrical panel were inspected for significant defects related to wiring terminations, overcurrent protection devices, grounding and bonding, circuit identification, overcrowding, and other readily visible safety hazards. No significant deficiencies were identified unless otherwise noted within this section.
Electrical Panel — Limited Remaining Capacity
The electrical panel appears to have little or no remaining breaker capacity. This may limit the ability to add circuits for future electrical work or renovations without further modification. Depending on future needs, options could include approved tandem breakers where permitted, adding a subpanel, or upgrading the panel or service as part of a larger electrical project. This is not necessarily a defect on its own — it's simply worth keeping in mind if additional circuits are anticipated down the road.
Multiple Electrical Recommendations
Multiple concerns are present within the electrical system, including conditions that may affect safety, reliability, or proper operation. When several deficiencies exist throughout an electrical system, the cumulative impact can increase the likelihood of overheating, nuisance tripping, unreliable operation, or other electrical performance concerns. The number and variety of conditions identified may also limit the ability to fully determine overall system condition through a visual inspection alone.
Recommendations:
Have a licensed electrician review the electrical system and complete recommended corrective work. The scope of work may reasonably include addressing identified deficiencies, correcting unsafe conditions, improving installation methods, and reviewing related electrical components or connections where similar conditions may exist to help support safe and reliable operation consistent with current electrical safety practices.
Key Points:
- Concealed electrical concerns may exist beyond visible areas
Note:
- According to the National Electrical Code (NEC), if the wiring in a home is updated or significantly altered, it may require upgrading the electrical panel to meet current code standards. This is especially true if the new wiring exceeds the capacity of the existing panel or if the panel is outdated or lacks necessary safety features, such as grounding or proper circuit protection. However, the exact requirements can vary depending on the scope of the rewiring, local codes, and the condition of the existing panel. A licensed electrician should assess the situation to ensure compliance and safety.
9.7 Sub Panel
Sub Panel If Applicable: Not Present
9.9 Electrical Grounding System
Electrical Grounding System: UFER Ground Not Visible
Info and LMT's. During a home or property inspection, every effort is made to inspect the visible components of the electrical system grounding. The grounding system is critical for safely discharging electrical surges, especially in the case of lightning strikes. There is no way in the context of a home inspection to verify the "effectiveness" of the grounding system as much of the system is not visible and there are not practical tests one can perform in the way we can test a furnace or a plumbing fixture. However, there are many things that can lead me to recommend further evaluation of the grounding system by a licensed electrical contractor and they will be documented in the observations below if discovered.
9.10 Electrical Bonding System
Bonding Noted: Present - Could Not Confirm, Bonding Noted on Water Pipes
Info and LMT's. During the inspection, I attempt to visually document electrical system bonding. There is no way in the context of a home inspection to verify the "effectiveness" of system bonding. All metallic systems in the building are required to be "bonded" (connected) to the the building's electrical grounding system. Bonding creates a pathway to shunt static charges (that would otherwise build up on the system) to earth, and to provide a pathway to trip a breaker in the event that these bonded metallic components became energized. There are many things that can lead me to recommend further evaluation of this system by a licensed electrical contractor and they will be documented as repair items in the observations below if discovered.
Gas Piping Bonding Not Verified
No visible bonding connection was identified at the metal gas piping system. Certain gas piping materials, particularly corrugated stainless steel tubing (CSST), may require bonding to help reduce the risk of damage from lightning-related electrical surges and to maintain proper electrical continuity between building systems. The presence, adequacy, and configuration of bonding for this gas piping could not be confirmed through a visual inspection alone.
Recommendations:
Have a licensed electrician, in coordination with a qualified plumbing or gas contractor as needed, review this condition and make corrections as recommended. The scope of work may reasonably include verifying the piping material, confirming whether bonding is required, installing approved bonding where needed, and addressing related grounding or bonding components that may not be fully visible.
Ch. 10 Electric Distribution and Finish Wiring
10.1 Branch Wiring
Wire Material: Copper, Multi-strand Aluminum
Wiring Method: Cloth cable sheathed wiring, Non-metallic sheathed cable
The representative visible components of the branch wiring system were inspected for significant defects related to wiring methods, terminations, junction boxes, conductor materials, support, physical damage, and other readily visible safety hazards. Most branch circuit wiring is concealed within walls, ceilings, floors, and insulation and is not visible as part of a visual home inspection. No significant deficiencies were identified unless otherwise noted within this section.
Abandoned Electrical Wiring
Abandoned or apparently unused wiring is present. The wiring does not appear to serve an active purpose; however, its status and whether it remains energized could not be fully determined as part of this visual inspection. Unused wiring can create confusion during future service work and, if energized, may present a potential safety concern. Abandoned conductors may also indicate prior alterations or removed equipment and are generally best addressed when identified.
Recommendations:
Have a qualified licensed electrician review the wiring and determine whether it remains energized. Corrective work may reasonably include removing abandoned conductors, properly terminating wiring, disconnecting unused circuits, and assessing related electrical components where similar conditions may exist.
Cloth-Covered Electrical Wiring Present
Cloth-covered electrical wiring is present within the home. This type of wiring is commonly associated with older electrical installations and often contains rubber insulation beneath the cloth sheathing. Over time, rubber insulation may dry out, crack, become brittle, or deteriorate, increasing susceptibility to damage when disturbed. While cloth-covered wiring may continue to function, age-related deterioration can affect reliability and may not provide the same level of durability, temperature rating, or compatibility with modern electrical equipment and installation practices.
Recommendations:
Have a licensed electrician perform corrective work as recommended. The scope of work may reasonably include assessing accessible wiring, representative concealed areas, conductor insulation conditions, splices, terminations, and connected electrical components to determine whether repairs, modifications, or replacement are appropriate. Additional review may be warranted where renovations, service upgrades, or alterations are planned to help support safe and reliable long-term performance.
Key Points:
- Cloth-covered wiring is commonly associated with older electrical systems.
Open Electrical Junction Box
An electrical junction box is missing its cover, leaving wiring and electrical connections exposed. Open junction boxes may increase the risk of accidental contact with energized components, electrical shock, short circuits, contamination from debris or moisture, and potential fire-related concerns. Electrical boxes are intended to remain fully enclosed to help protect wiring connections and maintain safe operation.
Recommendations:
Have a licensed electrician further assess and complete corrective work as recommended. Corrective work may reasonably include installing an approved junction box cover, verifying the integrity of wiring and electrical connections, securing conductors as needed, and assessing nearby or similar electrical boxes where comparable enclosure deficiencies or concealed safety concerns may exist to help support safe and reliable long-term operation.
Key Points:
- Open electrical boxes may expose occupants to energized wiring
Unprotected Electrical Wiring
Electrical wiring is present in a location where it is not adequately protected from physical damage. Wiring installed in exposed or vulnerable areas may be more susceptible to impact, abrasion, puncture, or contact with stored items, fasteners, or building materials. Damage to wiring insulation or conductors can increase the risk of electrical faults, shock hazards, arcing, or related safety concerns over time.
Recommendations:
Have a licensed electrician correct this condition as recommended. Corrective work may reasonably include installing approved protection where needed, rerouting or securing affected wiring, confirming proper support and clearance, and reviewing nearby wiring in similar exposed locations where comparable conditions may exist to help support safe and reliable long-term electrical performance.
Key Points:
- Exposed wiring is more vulnerable to physical damage and accidental contact
10.2 Receptacles and Fixtures
Inspection Method: Representative Testing
Electric Receptacles: Three wire receptacles, Two wire receptacles
Readily accessible receptacles were inspected by visual examination and tested with an appropriate receptacle tester, where applicable, to evaluate their general operation and wiring configuration. Receptacles that were obstructed, inaccessible, or otherwise not safely testable were excluded from inspection. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Receptacles of 220V/240V and 20-amp dedicated circuits are not assessed for functionality or polarity during the inspection, as they cannot be tested using a standard receptacle polarity tester. Any visible deficiencies pertaining to these receptacles will be noted in the report.
Info and LMT's. Fully confirming or locating GFCI protection in certain areas of the home may be challenging as the protection mechanisms are not always visible. When test and reset buttons are not present on each receptacle, tripping them with a polarity tester might inadvertently affect downstream receptacles that are obstructed by personal belongings or otherwise inaccessible. This could result in those receptacles losing power. I suggest verifying GFCI protection in all recommended areas after personal belongings have been removed or upon assuming ownership of the property. If you're unsure about this process, it's advisable to enlist the services of a licensed electrician for assistance.
Several GFCI protected breakers were noted to be wired in series.
A ground-fault circuit interrupter (GFCI) can be wired in series to protect other standard receptacles that are downstream of it. This method is called the multiple-location method.
Here are some things to know about wiring GFCIs in series:
How it works: The load terminals on a GFCI receptacle can be used to extend wiring to other receptacles. This gives the other receptacles GFCI protection, even though they aren't GFCI receptacles.
When to use it: This method is used when a single GFCI is needed to protect other standard receptacles.
What happens if the GFCI fails: If the GFCI fails, all of the downstream outlets will stop working.
Label Note:
These circuits seem to be GFCI protected, which is an acceptable repair. However, these receptacles should be labeled to indicate they are both ungrounded and GFCI protected. No labeling was found during inspection.
Limited Receptacle Coverage – Older Home
Older homes may have fewer electrical receptacles than are commonly provided in modern construction. This is not necessarily a defect, but additional receptacles may be considered during future renovations or electrical upgrades to improve convenience and reduce reliance on extension cords.
GFCI-Inconsistent With Modern Standards
Ground-fault circuit interrupter (GFCI) protection is not present or appears incomplete in areas where this type of protection is commonly expected by modern safety standards. GFCIs are designed to reduce the risk of electrical shock, especially in locations where moisture or increased electrical hazard may be present.
Recommendations:
Have a licensed electrician improve GFCI protection as recommended. Repairs may include installing or upgrading GFCI devices at appropriate locations, confirming proper downstream protection where applicable, and reviewing nearby outlets or circuits where similar protection may be needed to help improve overall electrical safety.
Note:
- I will avoid testing to determine if a receptacle or circuit is GFCI protected if it is not clear where the re-set button can be found. This is because re-set buttons can be concealed behind stored items, so such a test risks disabling a circuit in the home. Occasionally, during testing of GFCI's one can fail. This is a statistical reality that some of these devices will fail under testing and require replacement after testing.
Exterior Receptacle Not Weather-Rated
An exterior electrical receptacle does not appear to be listed or configured for weather-resistant use. Exterior receptacles are intended to be designed for exposure to moisture, humidity, and changing weather conditions. The use of a standard interior-type device outdoors may contribute to premature deterioration, unreliable performance, corrosion, or increased shock risk over time, particularly in exposed locations.
Recommendations:
Have a licensed electrician perform corrective work as recommended. Repairs may reasonably include replacing the receptacle with a properly rated weather-resistant device, confirming appropriate GFCI protection, improving weatherproof covers or sealing methods where needed, and assessing nearby outdoor electrical components where similar conditions may exist to support safe and reliable exterior operation.
Open Grounds Present
One or more receptacles tested with an open grounding condition. Open grounds can reduce the effectiveness of fault protection and may increase the risk of electrical shock or unsafe operation of connected equipment. This condition is commonly associated with older wiring methods, improper modifications, damaged wiring, or incomplete grounding upgrades.
Recommendations:
Have a licensed electrician further assess and complete recommended corrective work. Appropriate repairs may reasonably include identifying the source of the open grounding condition, repairing or replacing affected wiring or receptacles, confirming grounding continuity, and reviewing related branch circuits or receptacles where similar conditions may exist.
Key Points:
- Open grounds can reduce electrical fault protection
- Grounding helps reduce the risk of electrical shock
Link:
Older Two-Wire (Ungrounded) Electrical Outlets
Older two-wire electrical outlets are present in the home. These outlets lack an equipment grounding conductor, which is not consistent with modern electrical safety standards. Ungrounded outlets provide reduced protection against electrical shock and may not safely support certain appliances or surge-protected devices.
Recommendations:
Have a licensed electrician address the ungrounded outlets as recommended. Corrective work may reasonably include installing properly grounded wiring, adding GFCI protection with appropriate labeling where permitted, upgrading receptacles as conditions allow, and reviewing other outlets on the same circuit to help ensure consistent and safe protection in line with modern electrical practices.
Damaged Electrical Cover Plate
An electrical outlet cover plate is damaged. Damaged or broken cover plates can allow unintended access to energized components, increasing the risk of electrical shock, accidental contact, or damage to the receptacle assembly. Openings around electrical devices may also allow debris or moisture intrusion in certain locations, which can contribute to deterioration over time.
Recommendations:
Have a licensed electrician perform corrective work as recommended. Repairs may reasonably include replacing the damaged cover plate, securing the receptacle assembly, confirming proper attachment and condition of associated wiring, and assessing nearby outlets or similar devices where damaged covers, loose components, or related electrical concerns may also exist to support safe operation consistent with modern electrical practices.
10.3 Ceiling Fans and Lighting
Lighting: Present and Tested
Representative readily accessible lighting fixtures were inspected by visual examination and operated using normal controls to evaluate their general functionality and identify readily visible safety concerns. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Exterior dusk-to-dawn lights, motion lights, landscape lighting, or any lighting fixtures not affixed to the structure are not encompassed within a standard home inspection and were not evaluated for functionality. These elements are explicitly excluded from the inspection.
Missing Light Fixture Cover
A light fixture is missing its protective cover. Fixture covers are intended to shield bulbs and electrical components from accidental contact, physical damage, and contamination while also helping the fixture operate as designed. Without the cover in place, bulbs and internal components may be more vulnerable to breakage and may present an increased risk of accidental contact, particularly in occupied or storage areas.
Recommendations:
Have a licensed electrician or qualified contractor perform corrective work as recommended. The scope of work may reasonably include installing an appropriate fixture cover, confirming the fixture is securely mounted, verifying the condition of exposed components, and assessing nearby or similar fixtures where missing or damaged covers may also be present to help support safe and reliable operation.
Inoperative Light Fixture
A light fixture did not operate as intended at the time of inspection. This condition may be related to a failed bulb, switch issue, loose connection, fixture defect, or other electrical concern. Inoperative fixtures can reduce visibility and usability within the affected area and may indicate the need for servicing or repair.
Recommendations:
Have a qualified contractor or licensed electrician perform corrective work as recommended. Repairs may reasonably include replacing failed bulbs, servicing or replacing defective fixtures or switches, repairing related wiring or connections where needed, and confirming safe and reliable operation of associated electrical components.
10.4 Smoke and Carbon Monoxide Alarm Systems
CO Alarms Noted: Not Enough
CO Alarms: Not Enough, Present - On Second Floor
Smoke Alarms Noted: On Main Floor
Smoke Alarms: Present, None In Bedrooms, Old, Updating Recommended
Smoke and carbon monoxide alarms are important life-safety devices. Accessible alarms may be tested using normal test controls; however, this does not verify sensor sensitivity, age, interconnection, complete coverage, or future reliability.
For improved safety, verify that properly located and functioning smoke and carbon monoxide alarms are installed in accordance with current manufacturer recommendations and modern safety practices. Replacement or upgrades should be considered when alarm age, condition, or reliability cannot be confirmed.
Info and LMT's. Representative, accessible smoke and carbon monoxide alarms were tested using their normal test controls. This confirms only that the unit powers on and sounds — it does not verify sensor sensitivity, exact age, interconnection, complete coverage, or future reliability. Replacement and installation of alarms should follow current manufacturer instructions and applicable safety recommendations.
Inadequate Carbon Monoxide Alarm Coverage
The home does not appear to have sufficient carbon monoxide (CO) alarm coverage based on modern safety recommendations. Carbon monoxide is a colorless, odorless gas produced by fuel-burning appliances and attached garages and may pose serious health and life-safety risks when not properly monitored. Modern safety practices commonly recommend CO alarms outside sleeping areas and on each level of the home. Some smoke alarms may incorporate CO detection; however, this could not be confirmed where labeling or device specifications were not readily visible without invasive testing or disassembly.
Recommendations:
Have appropriate carbon monoxide alarms installed or updated as recommended to improve life safety. Corrective work may reasonably include adding alarms in commonly recommended locations, verifying proper operation and placement, reviewing interconnected alarm functionality where applicable, and assessing existing smoke and CO detection devices to help support adequate coverage consistent with modern safety practices and manufacturer recommendations.
Smoke Alarms – Insufficient Coverage
The home does not appear to have smoke alarms installed in all locations generally recommended by modern residential safety practices. Current recommendations commonly call for smoke alarms inside sleeping rooms, outside sleeping areas, and on every level of the home. Limited smoke alarm coverage may reduce early warning capability in the event of a fire and may increase life-safety risks to occupants.
Recommendations:
Have a licensed electrician or qualified alarm installation professional improve smoke alarm coverage as recommended. Corrective work may reasonably include installing additional alarms in commonly recommended locations, verifying proper operation, addressing wiring or interconnection concerns where applicable, and reviewing existing alarm devices to help support improved life-safety protection consistent with modern practices and manufacturer recommendations.
Key Points:
- Modern safety practices commonly recommend alarms inside sleeping rooms and on every level
Ch. 11 Heating, Cooling, Fireplaces and Ventilation
11.1
Per the Standards of Practice, the home inspector shall observe the permanently installed heating and cooling systems, including Heating and cooling equipment central to the home; visible ducts and piping, air filters, registers, and the presence of an installed heating and cooling source in each room. The home inspector shall describe the energy source and heating equipment. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily accessible access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe Humidifiers, Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. The efficiency of the units and load testing is not conducted. Air conditioning units cannot be tested when temperatures are lower than 60 degrees due to the possibility of damaging the compressor. Clients are advised to have an HVAC company perform maintenance on the system annually.
11.2 Thermostat
Location: Dining Room
11.3 Cooling Systems
Cooling System: Present
Data Plate
Manufacturer: Trane
Listed Nominal Capacity: 2.5 Tons
Energy Source: Electric
System Type: Air Source
Age: 2024
The representative visible components of the exterior cooling unit(s) were inspected for significant defects related to installation, physical condition, operation, refrigerant line connections, electrical components, and other readily visible deficiencies. The system was operated using normal controls to verify the production of conditioned air, weather permitting. No significant deficiencies were identified unless otherwise noted within this section.
HVAC Temperature Differential / Thermal Imaging
Thermal images may be used to document approximate temperatures at representative supply registers and to help confirm that the HVAC system responded to normal operating controls.
As a general reference, cooling systems often produce a supply-to-return temperature difference of approximately 12–20°F, while heating systems may produce a difference of approximately 15–25°F. Actual readings can vary significantly based on system runtime, airflow, humidity, outdoor temperature, duct configuration, filter condition, and measurement location.
These readings are not used to determine refrigerant charge, system efficiency, airflow balance, or overall HVAC performance. More detailed performance testing requires specialized HVAC equipment and is beyond the scope of a home inspection.
Basic Maintenance Recommendations
Routine professional servicing is recommended to help maintain cooling performance, efficiency, and reliability. Maintenance may include cleaning coils, replacing filters, maintaining proper airflow and equipment clearance, checking condensate drainage, and evaluating refrigerant levels and system operation. Condensate leakage or drainage problems should be corrected promptly to help prevent moisture-related damage.
Air Conditioning Testing and Outdoor Temperature:
Air conditioning systems should not be operated when outdoor temperatures have been below approximately 65°F within the previous 24 hours, as doing so can risk damage to the compressor. At the start of the inspection, temperatures were below this threshold; however, conditions later warmed above 65°F and had been above that temperature in the days prior. The system was operated once conditions were appropriate, and it responded as expected at the time of testing.
R-410A Refrigerant Transition
R-410A refrigerant is commonly used in many existing air-conditioning and heat-pump systems. New equipment is transitioning to refrigerants with lower environmental impact, and R-410A is gradually being reduced for use in newly manufactured systems.
Existing R-410A equipment can continue to be operated, maintained, and serviced. Refrigerant availability and service costs may change over time as the industry transition continues, but replacement of an otherwise functional system is not recommended solely because it uses R-410A.
Air Conditioning System – Servicing / Maintenance Recommended
The air conditioning system would benefit from professional servicing and maintenance to support reliable cooling performance and long-term operation. Cooling systems contain multiple mechanical and electrical components that commonly experience wear over time, including capacitors, contactors, coils, refrigerant components, blower assemblies, condensate systems, and electrical connections. Even when a system appears operational at the time of inspection, age, deferred maintenance, restricted airflow, dirty components, low refrigerant conditions, or normal wear may affect efficiency, cooling performance, moisture control, and remaining service life. Routine servicing is considered an important part of maintaining HVAC system reliability and performance.
Recommendations:
Have a qualified HVAC contractor perform recommended servicing and maintenance to the air conditioning system. Servicing may reasonably include cleaning coils and components, verifying refrigerant performance, inspecting electrical and safety controls, evaluating airflow and temperature differentials, servicing condensate components, replacing filters, and assessing related HVAC components where similar wear, deferred maintenance, or performance concerns may exist to support safe and reliable operation consistent with manufacturer recommendations.
Key Points:
- Routine HVAC servicing can help improve cooling performance and energy efficiency
- Annual professional servicing may help identify developing concerns before larger failures occur
11.4 Heating System
Heating System: Present
Data Plate
Location: Basement
Energy Source: Natural gas
Manufacturer: Trane
Last Service Record: None
Listed Max Capacity Per Data Plate: 80,000 btu's
Heating Method: Gas forced air furnace
Age: 2023
The representative visible components of the interior unit(s) were inspected for significant defects related to installation, physical condition, operation, condensate management, electrical components, and other readily visible deficiencies. The system was operated using normal controls to verify the production of conditioned air. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. The HVAC system inspection is restricted to assessing the system's response to normal operating controls, including the thermostat, in both heating and cooling modes (subject to weather conditions). It also involves visually observing the exterior and interior equipment non-invasively and removing any access panels designed for easy removal by homeowners without the need for tools. For a more comprehensive inspection, it's advisable to consult an HVAC contractor.
This house has a gas forced air furnace. Its heat exchanger separates combustion byproducts from the home's air supply but is fully enclosed within the equipment and cannot be visually inspected; it is excluded from this inspection.
Forced Air Furnace Servicing Recommended
No recent service records were available for the forced-air furnace at the time of the inspection. Regardless of maintenance history, regular professional servicing is recommended to help support safe and efficient operation, maintain manufacturer-recommended performance, and identify developing concerns before more significant issues occur. Heating equipment naturally experiences wear from seasonal operation and normal use, and routine maintenance may help extend the service life of the system while providing a documented service history for future reference.
11.5 Air Filters
Air Filter Size: 20 x 25 x 4
Notes: Filters Were Clean, Filters Are Located at Cold Air Returns, Be Sure to Change or Clean Quarterly
Filtration Systems: Disposable
11.6 Vents and Flues
Vents and Flue Style: High Efficiency
The representative visible components of the combustion venting system were inspected for significant defects related to vent materials, clearances to combustibles, support, slope, connections, termination, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
High-Efficiency Furnace PVC Vent Termination
The high-efficiency furnace vents to the exterior through PVC piping. The vent termination appears vulnerable to debris accumulation, snow obstruction, vegetation interference, or pest entry if not properly maintained. Obstructions or restrictions at furnace vent terminations may interfere with combustion airflow and venting performance, which can affect furnace operation, efficiency, and overall system reliability. Proper vent termination configuration is important for safe appliance performance and long-term durability.
Recommendations:
Have a qualified HVAC contractor review the furnace vent termination and complete corrective work as recommended. Corrective work may reasonably include confirming the vent termination configuration aligns with manufacturer requirements, clearing obstructions, improving protection against debris or pest entry, verifying proper vent clearances, and assessing related venting components where similar airflow or termination concerns may exist to help support safe and reliable long-term furnace operation.
High-Efficiency Furnace Operating as Single-Pipe System
The high-efficiency furnace is currently configured as a single-pipe system, drawing combustion air from inside the home rather than from a dedicated exterior intake. While some high-efficiency furnaces are permitted to operate this way depending on manufacturer specifications and installation conditions, two-pipe configurations are generally preferred for improved efficiency, combustion performance, and indoor air quality.
Recommendations:
Have a licensed HVAC contractor review the furnace installation and complete recommended corrective work if needed. The scope of work may reasonably include verifying manufacturer installation requirements, evaluating combustion air availability, and determining whether conversion to a two-pipe system would improve safety, efficiency, or system performance.
11.7 Heating and Cooling Distribution Systems
Distribution Method: Forced Air / Ducts
Heat Source in Each Room: Present
Info and LMT's. An infrared camera was utilized to demonstrate that the system(s) responded to normal operating controls during the inspection. However, these images are not intended to depict the precise temperature differential, efficiency, or performance of the system, as these aspects fall outside the scope of a home inspection. For accurate readings, HVAC thermometers (wet bulb) are necessary, and an HVAC contractor would conduct measurements at different locations.
In cooling mode, typical temperature differentials between return and supply air can range from 12 to 20 degrees, while in heating mode, they can range from 15 to 25 degrees. Numerous factors, including indoor and exterior ambient air temperatures, humidity levels, and the condition of the air filter and evaporator, among others, can influence these values.
Duct Tape Used on HVAC Ductwork
Standard cloth-backed duct tape is present on portions of the HVAC ductwork. This type of tape is generally not intended for permanent HVAC duct sealing applications, as it commonly deteriorates over time due to temperature fluctuations, airflow, humidity, and age. Deteriorated duct sealing materials may contribute to conditioned air leakage, reduced system efficiency, airflow imbalance, dust infiltration, and overall reduced HVAC performance.
Recommendations:
Have a qualified HVAC contractor assess the ductwork and complete recommended corrective work to improve duct sealing performance. Corrective work may reasonably include removing deteriorated tape materials, applying HVAC-rated foil tape or mastic sealants, improving duct alignment and support conditions, and assessing connected duct components where similar leakage or installation concerns may exist to support proper long-term airflow and system efficiency.
Key Points:
- Standard duct tape commonly deteriorates over time when used on HVAC systems
11.8 Mechanical Ventilation Systems
Whole House Fans, Ventilation and HRVs: Present, Indoor Air Quality System Note
Attic Terminations: Fans Not Visible
Info & LMT's: Bathroom Exhaust Vent Terminations Not Visible. The bathroom exhaust vent terminations were not visible within the attic at the time of the inspection. As a result, the routing, termination location, and installation of the exhaust ducts could not be fully verified. The inspection was limited to visible and readily accessible areas, and no determination could be made regarding whether the exhaust fans terminate at the exterior, within concealed spaces, or by another method.
Whole-House Mechanical Ventilation
The home is equipped with a whole-house mechanical ventilation system that operates through the HVAC system and is typically controlled at the thermostat or ventilation control. These systems periodically introduce or circulate air to help manage indoor air quality and moisture levels. Operating settings can vary based on the equipment, season, occupancy, and indoor humidity; manufacturer-recommended settings should be used and adjusted as needed for normal household conditions.
An indoor air quality system was noted near the furnace. These systems may include components such as enhanced filtration, humidity control, UV treatment, or ventilation to improve overall air quality in the home. While not part of the primary heating or cooling equipment, they can contribute to occupant comfort and health. Regular maintenance per the manufacturer’s instructions is recommended.
11.9 Fireplaces
Fireplace(s) If Applicable: Gas Fireplace Present
Mantle Present: Yes
Gas Rating Sticker Noted: No
Screen Covering For Direct Vent: Yes
The representative visible components of the solid-fuel-burning fireplace or appliance were inspected for significant defects related to the firebox, damper, hearth, chimney connection, clearances to combustible materials, and other readily visible deficiencies. The appliance was inspected by visual examination and normal operating controls, where possible. No significant deficiencies were identified unless otherwise noted within this section.
The representative visible components of the gas fireplace were inspected for significant defects related to installation, operation, venting (if applicable), burner performance, safety controls, clearances, and other readily visible deficiencies. The fireplace was operated using normal controls, where possible. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT’s – Gas Fireplace Not Operated. The gas supply to the fireplace was shut off at the time of inspection. Home inspectors in Ohio are not permitted to operate or open closed gas valves; therefore, the fireplace could not be operated or functionally tested.
The owner or seller should operate the fireplace and verify proper operation, ignition, and shutdown prior to property transfer. Any deficiencies or concerns should be addressed by a qualified professional as needed.
Gas Fireplace Mantel Clearance
A mantel is installed above the gas fireplace. Clearance requirements vary by fireplace manufacturer and depend on factors such as mantel depth, material, and distance above the firebox. These requirements could not be fully verified during the visual inspection.
Use caution when operating the fireplace and avoid placing heat-sensitive or combustible materials near the unit. If manufacturer documentation is available, verify that the mantel installation meets the specified clearance requirements. If proper clearance cannot be confirmed, have a qualified fireplace technician evaluate the installation and make corrections as needed.
The gas fireplace does not appear to be correctly labeled. Have this fireplace serviced and repaired to ensure it has the proper LP rated burner and it is correctly labeled.
Creosote Accumulation in Wood-Burning Appliance Venting System
Creosote accumulation was noted within the venting system serving a wood-burning appliance. Creosote is a combustible byproduct of wood combustion that can accumulate on interior chimney or flue surfaces over time. Excessive buildup may increase the potential for chimney fires and can affect draft and venting performance. The extent of accumulation visible during a home inspection does not determine the overall condition of the venting system, as portions of the chimney and flue are concealed from view.
Recommendations:
Have a qualified chimney contractor or certified chimney sweep clean and inspect the venting system prior to continued use as recommended. Corrective work may reasonably include removal of creosote deposits and inspection of accessible chimney, flue, connector pipe, cap, damper, and related components where similar defects or deterioration may exist.
Key Points:
- Creosote is combustible and can contribute to chimney fires.
Inadequate Fireplace Hearth Extension
The hearth extension in front of the wood-burning fireplace appears smaller than commonly recommended clearances. Hearth extensions are intended to provide a noncombustible surface that helps protect adjacent flooring from sparks, embers, and radiant heat. Hearth sizing can vary depending on the fireplace manufacturer and installation details; however, general guidance commonly recommends a hearth extension of at least 20 inches in front of the firebox opening and 12 inches beyond each side for fireplaces with openings greater than 6 square feet. For smaller fireplaces, commonly referenced minimum dimensions are 16 inches in front and 8 inches beyond each side of the opening. The existing hearth extension appears smaller than these commonly accepted dimensions.
Recommendations:
Have a qualified chimney professional, fireplace specialist, or mason review the hearth extension and perform corrective work as recommended. Improvements may reasonably include extending the noncombustible hearth surface, verifying clearances to combustible materials, and assessing related fireplace components where similar safety concerns may exist.
Key Points:
- Commonly referenced guidelines call for 20 inches in front and 12 inches on each side for larger fireplaces, or 16 inches in front and 8 inches on each side for smaller fireplaces.
11.10 Additional Heat Sources
Description: Not Present
Ch. 12 Plumbing
12.1
Per the Standards of Practice, the home inspector shall observe at visible portions: Interior water supply and distribution system, including piping materials and supports; fixtures and faucets; functional flow; leaks; and cross-connections. Interior drain, waste, and vent system, including traps; drain and waste lines; leaks; and functional drainage. The home inspector shall describe Water supply and distribution piping materials; Drain, waste, and vent piping materials; and the Location of the main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance.
The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.
12.2 Water Meter
Water Meter Location: Location of Water Meter Note
12.3 Water Service Supply
Pipe Material: Copper
Water Supply: Public water
Pressure Reducing Valve: None noted
Water Pressure: 75 PSI
This shows the water pressure tested during inspection. Generally, "normal water pressure," should be between 30-80 PSI, though pressures near or below 30 can result in poor functional flow to fixtures. Water pressures in excess of 80 PSI risk damaging supply piping components and should be controlled with a pressure reducing valve.
12.4 Distribution Pipe
Supply Pipe Materials: Copper, PEX
Pipe Insulation: Not Visible
Circulation Pump: Not Present
Functional Flow: Inconsistent (Localized Problems)
The representative visible components of the water supply piping system were inspected for significant defects related to leaks, physical damage, improper installation, support, corrosion, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Sections of the plumbing system that are concealed by finishes, storage areas, walls, floors, ceilings, below the structure, or beneath the ground surface were not inspected. Supply piping and other concealed plumbing cannot be fully evaluated, and its condition, installation quality, or potential for leaks cannot be verified. Overflow backup was not tested to avoid the risk of water damage, as aged gaskets may fail. Continued monitoring for signs of leakage or damage is recommended, and evaluation by a licensed plumber may be warranted if concerns arise
Info and LMT's. This building has PEX tubing used for supply piping. Crimp ring connections on PEX pipe have very specific installation guidelines and most of these connections will not be visible at the time of inspection (just like any other type of pipe fitting). It is beyond the scope of this inspection to evaluate a significant number of these connections. Any leaking noted at fittings should result in more careful inspection of all of the plumbing system by a licensed plumber that is experienced in the installation of these types of connections
Push-to-Connect (SharkBite-Style) Plumbing Fittings Present
Push-to-connect fittings are present within the plumbing system. These fittings are commonly used in residential plumbing, and their long-term performance depends on proper installation, pipe preparation, accessibility, and ongoing condition. No defect is assigned to these fittings based on their presence alone.
Continue routine monitoring of the fittings as part of normal home maintenance, and have a licensed plumber review any fitting where leakage, movement, corrosion, or other concerns develop.
Functional Water Flow – Below Typical Performance
Water flow at one or more fixtures is lower than typically expected for normal residential use. Reduced flow can result from partially closed valves, debris accumulation, mineral buildup, or developing restrictions within supply piping. Prolonged reduced flow may affect fixture performance and daily usability.
Recommendations:
Have a licensed plumber complete recommended corrective work to address the reduced flow. Necessary improvements may reasonably include assessing shutoff valves, aerators, supply connections, and representative portions of the distribution piping where similar restrictions may exist to help restore proper water flow consistent with modern plumbing practices and manufacturer guidance.
Saddle (Piercing) Valve Present
A saddle valve, also known as a piercing valve, is installed at the plumbing supply piping. These fittings are commonly used for refrigerator or icemaker supply lines but are generally considered less reliable than modern plumbing connection methods. Saddle valves are more susceptible to internal restriction, leakage, corrosion, and operational failure over time due to their small opening size and piercing-style connection to the pipe. Older installations may also become difficult to fully close or may leak when operated after long periods of inactivity.
Recommendations:
Have a licensed plumbing contractor correct the condition as recommended. Corrective work may reasonably include removing the saddle valve, installing a more reliable shut-off and supply connection, repairing affected piping as needed, and assessing nearby plumbing supply components where similar fittings or concealed leakage conditions may exist to help support reliable long-term performance consistent with modern plumbing practices.
12.5 Waste Pipe and Discharge
Discharge Type: Public Sewer - Buyer
Waste and Vent Pipe Materials: Cast Iron, ABS plastic, PVC
Location of Sewer Cleanout: Basement
The representative visible components of the drain, waste, and vent (DWV) piping system were inspected for significant defects related to leaks, physical damage, improper installation, support, proper drainage, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Only visible portions of the plumbing waste and drain systems could be inspected. Concealed piping and underground drains were not accessible, and full verification of flow or blockages is beyond the scope of this inspection.
Sewer Scope Recommended
The buried sewer lateral connecting this home to the municipal sewer line is outside the scope of a visual home inspection. Given the age of this property, having a sewer camera inspection performed is a reasonable due-diligence step if one hasn't been done recently. This is offered as a general recommendation for a home of this era rather than an indication that a specific defect is known to exist in the sewer line.
Cast Iron
Cast iron is a heavy, durable material traditionally used for drain, waste, and vent (DWV) systems, especially in older homes. It is valued for its strength and sound-dampening qualities but can be prone to internal corrosion and buildup over time, which may lead to blockages or leaks. While sections of cast iron piping can remain functional for decades, deterioration is common with age.
Old Metal Waste Piping
Older metal waste piping is present in the home. Materials such as galvanized steel or cast iron can deteriorate internally over time due to corrosion, which may lead to reduced flow, leaks, or eventual failure. While these pipes may still be functioning, their remaining service life can be limited depending on age, condition, and past use.
This item is provided for general awareness only. Older waste piping is common in homes of this age, and no determination is made regarding remaining service life. Budgeting for repair or replacement may be considered over time as part of ongoing maintenance and updates.
Plumbing Drain – Missing P-Trap
A P-trap was not present at the plumbing fixture drain. P-traps are designed to retain a water seal within the drainage system, helping to prevent sewer gases, odors, and potentially harmful contaminants from entering the living space. A missing P-trap is considered an improper plumbing condition and may allow sewer gases to enter the home while also affecting proper drainage performance.
Recommendations:
Have a qualified licensed plumber install a properly configured P-trap as recommended. The scope of work may reasonably include modifying drain piping, correcting improper fittings, verifying proper drainage performance, and assessing related plumbing components where similar installation deficiencies may exist.
Key Points:
- A P-trap helps prevent sewer gases from entering the home.
Sink Draining Into Floor Drain
The basement sink discharges directly into the floor drain rather than being properly connected to the building’s sanitary drainage system. This arrangement may allow wastewater to spill, splash, or back up around the floor drain and is not consistent with typical modern plumbing practices for a permanently installed sink.
Recommendations:
Have a qualified plumbing contractor evaluate and properly connect the sink drainage to an approved sanitary waste line. The completed installation should include appropriate drainage, trapping, and venting as applicable to help provide reliable operation and reduce the potential for leakage, drainage issues, or unsanitary conditions.
Leak at Waste Pipe
Leakage was noted at the waste pipe. Active leakage at drain piping can contribute to moisture damage, deterioration of surrounding building materials, staining, and conditions conducive to microbial growth if not corrected. Even relatively minor drain leaks can result in concealed damage over time, particularly where leakage occurs within wall, floor, cabinet, or ceiling assemblies.
Recommendations:
Have a qualified licensed plumber perform corrective work as recommended. The scope of work may reasonably include repairing or replacing affected drain components, verifying proper drainage performance, identifying the source of leakage, and assessing adjacent materials for signs of moisture-related damage or concealed deterioration where conditions warrant.
Note:
- After repairs are completed, run water for an extended period of time to confirm there are no additional leaks downstream.
12.6 Water Heater
Manufacturer: Kenmore
Data Plate
Energy Source: Gas
Size: 40 gal
System Type: Tank
Bollard: None Required
Straps: Not Present
Expansion Tank: None Noted - Recommended
Drain Pan: Present with drain
Age: 2009
Relief Valve: Present - Not Tested, Leaking
The representative visible components of the water heater were inspected for significant defects related to installation, operation, venting (where applicable), safety controls, plumbing and electrical connections, and other readily visible deficiencies. The water heater was operated using normal controls, where possible. No significant deficiencies were identified unless otherwise noted within this section.
Per the Standards of Practice, the inspector will examine and report the condition: of the water heater enclosure, plumbing supply, energy source, venting, and TPR valve, if applicable. The inspector is not required to: activate the system if it is powered down or the pilot flame is not lit, Inspect the system for proper sizing, design, or use of proper materials.
Temperature & Pressure Relief Valve (TPRV)
Water heaters are equipped with a temperature and pressure relief valve (TPRV) designed to discharge water if excessive temperature or pressure develops within the tank. A properly installed discharge pipe directs this discharge to a suitable termination location while reducing the potential for contact with hot water or steam.
TPRV discharge piping requirements can vary based on the water heater, valve manufacturer, installation location, and applicable requirements. Where concerns are identified, recommendations are based on the visible installation, manufacturer guidance when available, and accepted plumbing practices.
The TPRV is not manually operated as part of the home inspection because an older or deteriorated valve may fail to reseal after testing. Visible leakage, improper discharge piping, damaged components, or other concerns will be addressed separately when present.
Expansion Tank - None Noted
An expansion tank is recommended for the water heater; these are required if the house has a closed plumbing system. Expansion tanks help reduce pressure on the plumbing system by creating a buffer or a place for water to expand into as water swells during thermal expansion. Installation of expansion or pressure tanks is modern installation practice and will be required if a pressure reducing valve has been installed on a public water supply.
Water Heater – Temperature and Pressure (TPR) Relief Valve Actively Leaking
The temperature and pressure (TPR) relief valve is actively leaking. A leaking TPR valve may indicate a faulty valve, excessive system pressure, thermal expansion concerns, or elevated water temperature. Because the TPR valve is a critical safety device designed to relieve excessive pressure within the water heater, leakage should not be considered normal and warrants prompt attention.
Recommendations:
Have a qualified plumbing contractor diagnose and correct the cause of the leaking TPR valve as recommended. Corrective work may reasonably include replacing the relief valve, verifying proper water pressure, evaluating the thermal expansion control system (where applicable), confirming appropriate water temperature settings, and addressing any related conditions contributing to the leakage.
Key Points
• Active leakage may indicate a failed valve or an underlying system condition requiring correction.
Signs of Backdrafting at Water Heater
Evidence consistent with possible backdrafting was noted at the water heater vent connection. Backdrafting can occur when combustion gases fail to properly draft through the venting system and instead spill at the draft hood or vent connector. This condition can affect safe appliance operation and may allow combustion byproducts to enter the interior.
Recommendations:
Have a licensed plumber or qualified HVAC contractor correct this condition as recommended. Corrective work may reasonably include assessing vent connector configuration, vent performance, combustion air conditions, and related appliance venting components where similar drafting concerns may exist to help support safe operation.
Older Water Heater-Monitor and Service
The water heater appears to be older and operating at the time of inspection. While no active failure was noted, water heaters of this age are generally more susceptible to leakage, reduced efficiency, internal corrosion, and unexpected failure as components continue to age. Aging water heaters can deteriorate internally without visible exterior symptoms, and remaining service life can vary significantly depending on usage, maintenance history, water quality, and operating conditions.
Recommendations:
Continued monitoring and routine servicing of the water heater are recommended. Maintenance may reasonably include periodic inspection of plumbing connections, venting components, temperature and pressure relief components, and surrounding areas for signs of leakage or deterioration. Planning and budgeting for replacement are advised due to the apparent age and increased likelihood of future failure consistent with normal water heater aging patterns.
Notes:
- Water was hot at the time of inspection.
- To best preserve this tank, you could consider a servicing where the tank is flushed and the anodes are checked and updated if needed.
12.7 Water Temperature
Water Temperature Measured During Inspection: Could Not Accurately Test Water Temperature Today
If no water temperature is listed here, I was unable to obtain an accurate temperature reading. For optimal safety, water temperature should not exceed 120 degrees F at the tap or plumbing fixture. Adjust the temperature as needed.
12.9 Exterior Hose Bibs
Hose Bibs if Applicable: Operating
The representative visible components of the hose bib were inspected and operated, where possible, to evaluate proper operation, attachment, leakage, freeze protection (where applicable), physical condition, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Winterize During Colder Months
The exterior hose bib is susceptible to freezing in cold weather. To help prevent damage, be sure to winterize it or provide a heat source during periods of extreme cold.
Missing Anti-Siphon Protection
One or more exterior hose bibs is not equipped with anti-siphon protection. Anti-siphon devices help prevent contaminated water from being drawn back into the home's potable water supply during a pressure loss or backflow event. Modern plumbing practices commonly call for exterior hose connections to be protected with an approved anti-siphon or backflow prevention device.
Recommendations:
Have a licensed plumber correct this condition as recommended. Corrective work may reasonably include installing approved anti-siphon or backflow prevention devices and assessing similar exterior hose connections where comparable conditions may exist.
Key Points:
- Modern plumbing practices commonly include protection at exterior hose connections
Ch. 13 Additional Plumbing
13.1 Sump Pumps and Drains
Floor Drain: Basement Floor Drain Present
Sump Pumps: Present, ON GFCI Note - No Recommendation
In Ohio, home inspections do not include manual testing of sump pumps. This inspection is limited to the visible components and general operation of the sump pump system, without dismantling equipment or performing invasive procedures. The evaluation includes observations of accessible parts, signs of wear, and whether the pump appears to operate as intended at the time of inspection. This does not guarantee long-term reliability, account for hidden defects, or predict future performance.
Info and LMT's. Sump Pump – General Information
Sump pumps typically have a lifespan of about 7 to 10 years, though this can vary based on factors such as frequency of use, maintenance, installation quality, and overall build. Submersible pumps generally fall within this range, while pedestal models may last longer.
The exact age of the sump pump installed in this home could not be determined during the inspection. Without documentation or visible manufacturing dates, it's not possible to verify how long the unit has been in service.
As with any mechanical component, regular testing and maintenance are recommended. If concerns arise or the unit is older, evaluation or replacement by a qualified plumber or waterproofing specialist may be advisable.
Info and LMT's. A floor drain was present. I do not test floor drains but I do recommend they be tested for function by the homeowner or a handy-person by running a hose in them for a prolonged time or having them professionally scoped by a qualified plumber. The traps in these drains sometimes dry-out allowing sewer gases and vermin into the home. As a part of routine maintenance I recommend making sure drain trap has water in it and is properly covered.
This house has a sump pump system installed. This is on a GFCI protected circuit, which is recommended by electrical code, but risks accidental trips which could disable the pump. The sump pit was dry at the time of inspection and the system seems to be working. I recommend disclosing any additional information about this system. If it is needed to keep this space dry, additional battery back-up can be added.
13.2 Radon Equipment
Radon Equipment if Applicable: Not Present
13.3 Water Filters
Not Present
13.4 Sewage Ejector Pumps
Not Present
13.5 Central Vacuum
Not Present
13.6 Fire Suppression
Not Present
13.7 Irrigation
Not Present
13.8 Spa
Not Present
13.9 Water Features
Not Present
13.10 Sauna
Not Present
13.11 Swimming Pools
Not Present
Ch. 14 Interior Living Area(s) and Bedrooms
14.1
Per the Standards of Practice, the home inspector shall observe walls, ceilings, and floors; steps, stairways, balconies, and railings; counters and a representative number of installed cabinets; and a representative number of doors and windows; fireplaces by examining the firebox, operating the damper, and reporting on the presence of a gas shut off valve. The home inspector shall: Operate a representative number of receptacles, switches, windows, and interior doors; and report on signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.
The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting, tile; or Draperies, blinds, or other window treatments. Gas fireplaces are not tested for functionality, and the pilot light will not be lit if it's off at the time of inspection. An evaluation by a gas company is recommended before using any gas appliances in the home.
14.2 Interior Overview Photos
The photos provided here show representative images of the living areas at the time of inspection.
Info and LMT's. Assessing the quality and condition of interior finishes involves a significant degree of subjectivity. Factors such as cleanliness, cosmetic imperfections, material quality, architectural aesthetics, and color fall outside the purview of this inspection. Comments provided will be general in nature, unless specific functional concerns are identified. It's important to note that furniture, area rugs, storage items, appliances, and wall hangings are not relocated during the inspection, which may obscure potential defects.
Items such as carpeting, window treatments, central vacuum systems, household appliances, screens, recreational amenities, paint, wallpaper, and other finish treatments are not inspected unless explicitly mentioned in the report. It is recommended to conduct a thorough review of interior areas during the final walk-through inspection before closing. Please note that only areas that were readily visible and accessible were inspected on the day of assessment.
14.3 Walls, Ceilings and Trim
Wall and Ceiling Materials: Drywall, Wood
A representative sample of the visible interior wall, ceiling, and trim finishes was inspected to evaluate their general condition and identify any readily visible signs of damage, deterioration, installation concerns, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's This building has ceiling tiles installed, often referred to as a drop ceiling. While these ceilings are reasonably accessible for renovation work, they present challenges for visual inspection as tiles can get difficult top re-install without the proper tools. We try and look up under drop ceilings were practical without damaging tile finishes, but inspection of the spaces concealed by these dropdown ceilings is limited.
Typical Wall dings
Minor blemishes such as wall dings were noted in the walls. Minor blemishes such as wall dings, nail pops, and small cracks were noted in the walls and ceilings. These are typical in older or lived-in homes and do not appear consistent with structural concerns at this time.Repair and paint cracks, nail pops, and other cosmetic blemishes as needed and continue to monitor.
Note:
- Some wall and ceiling areas were obstructed by personal belongings at the time of inspection—be sure to check these areas during your final walk-through to confirm there are no additional damages.
Minor Interior Wall/Ceiling Cracking
Minor cracking is present at interior wall and/or ceiling finishes. Small cracks of this nature are commonly associated with normal material shrinkage, seasonal humidity changes, and typical settlement or movement that can occur over time. Based on visible conditions at the time of inspection, the cracking appeared consistent with a finish-related condition rather than clear evidence of structural failure.
Recommendations:
Have a qualified drywall contractor or general contractor repair the affected areas as desired. Corrective work may reasonably include patching, sealing, and refinishing cracked surfaces, along with checking nearby finish areas where similar movement or separation may be present to help maintain a finished appearance consistent with normal residential upkeep.
Low Ceiling Height – Reduced Headroom Clearance
Ceiling height in one or more areas is lower than typically expected under modern residential standards. Reduced headroom—particularly along walking paths or near structural elements—can increase the risk of head contact or injury during normal use. This condition is commonly found in older homes or finished basement areas but should still be considered a safety concern.
Recommendations:
Have a qualified contractor provide recommended improvements to low-clearance areas as needed to help reduce the risk of head impact or injury. Corrective work may reasonably include modifying finishes, improving visibility, adding protective padding, or addressing nearby structural or framing components where similar clearance limitations may exist to support safer use consistent with modern expectations.
14.4 Floors and Floor Materials
Floor Materials: Hardwood
Floor Settlement: Minor
A representative sample of the visible and accessible floor system components was inspected to evaluate the overall condition and identify any readily visible signs of damage, excessive deflection, or other structural deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Floor Settlement-Minor to Moderate
Localized areas of floor settlement or unevenness were noted during inspection. These conditions may result from normal age-related movement, minor framing deflection, or gradual foundation settlement common in older homes. At the time of inspection, no significant structural distortion or safety concerns were visible.
I would still recommend monitoring the area over time and consulting a qualified foundation or structural contractor if movement continues or worsens.
14.5 Interior Doors and Doorstops
Interior Doors: Solid Core
A representative number of readily accessible interior doors were inspected by operating them, where possible, to evaluate their general condition, operation, latching, alignment, and identify any readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Interior Doors and Hardware – Aged Components
Some interior doors and door hardware in the home are older and may show signs of wear, such as sticking, squeaking, or misalignment. While generally functional, these components may require more maintenance over time and could affect ease of operation or aesthetics. Homeowners may wish to budget for future upgrades or replacement to improve functionality and appearance.
Interior Door Not Latching
The interior door does not latch consistently and does not remain securely closed. This condition is commonly associated with alignment, hardware, or wear-related issues and can affect function, privacy, and long-term performance of the door components.
Recommendations:
Have a qualified carpenter or licensed general contractor perform the necessary repairs or adjustments to restore proper latching and reliable operation. Corrective work may reasonably include assessing related door components—such as the latch, strike plate, hinges, or door alignment—where similar conditions may exist, consistent with modern door installation and hardware practices.
14.6 Windows
Interior Window Frame: Wood
Window Glazing: Double pane, Single pane
Window Styles: Sliding, Fixed pane
A representative number of readily accessible windows were inspected by operating them, where possible, to evaluate proper operation, latching, weather-tight closure, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Single-Pane Windows Present
Single-pane windows were present in the home. These windows were common in older construction but typically provide less insulation and energy efficiency than modern insulated glazing units. In addition, older single-pane glass may not provide the same impact resistance as modern tempered safety glass used in many locations today.
No immediate repairs were required at the time of inspection; however, upgrading to modern insulated windows with safety glazing where applicable may improve energy efficiency, durability, and occupant safety.
Older Windows – Age-Related Considerations
Windows of this age are approaching the later portion of their typical service life and may not perform to modern energy or comfort standards, even if functioning at present. As materials age, these windows can become more susceptible to air leakage, seal deterioration, and reduced efficiency over time.
Monitoring window performance over time is reasonable, particularly for signs such as operational difficulty, drafts, condensation between panes, or moisture intrusion. Replacement or upgrades may be appropriate if performance declines and are commonly addressed as part of planned improvements or future window updates rather than immediate corrective action.
Cracked Window Pane
A pane of glass within the window is cracked. Cracked glass weakens the window assembly and may reduce energy efficiency, increase the potential for moisture intrusion, and contribute to further cracking or breakage over time. Depending on the cause, movement of the window frame or surrounding components may also be contributing factors.
Recommendations:
Have a qualified glass contractor or window specialist complete recommended repairs. Corrective work may reasonably include replacing the damaged pane, verifying proper sealing and glazing, and assessing the window frame, sash, hardware, and surrounding components where related conditions may exist to support proper performance consistent with manufacturer recommendations and modern installation practices.
Key Points:
- Cracked glass is more susceptible to additional breakage.
- Cracks can allow moisture intrusion and contribute to long-term deterioration.
Failed Window Seal / Condensation Between Panes
Condensation is present between the panes of a multi-pane window, indicating the insulated glass seal has likely failed. Failed seals allow moisture to enter the space between the glass panes, reducing clarity and potentially diminishing the insulating performance of the window assembly.
Recommendations:
Have a qualified window contractor repair or replace the affected insulated glass unit as recommended. Corrective work may reasonably include replacing the glass assembly, assessing the condition of the window frame, and reviewing similar windows where comparable seal failures may exist.
Key Points:
- Condensation between panes typically indicates a failed insulated glass seal
Windows – Inoperable or Improper Locking
One or more windows do not lock properly. Window locks are intended to provide basic security, help keep the sash properly aligned, and maintain a tighter weather seal when closed. Locks that do not operate as intended may reduce security, allow unintended movement of the window, and contribute to air or moisture infiltration over time.
Recommendations:
Have a qualified contractor or window specialist complete repairs as recommended. The scope of work may reasonably include adjusting or replacing locking hardware, correcting sash alignment, repairing damaged operating components, verifying proper engagement of the locking mechanisms, and addressing related window components where similar conditions may exist to support proper operation and weather resistance.
Missing Window Locks
One or more windows are missing locking hardware. Missing locks can reduce security, affect normal operation, and may limit the window’s ability to remain fully secured when closed.
Recommendations:
Repairs or replacement of the missing window locks are recommended as part of future maintenance or improvement projects. Corrective work may reasonably include installing compatible locking hardware and addressing similar operational concerns at nearby windows where present.
Key Points:
- Missing locks can reduce window security
Window Will Not Stay Open
One or more windows will not remain open on their own. This condition can make the window difficult to operate safely and may indicate worn or failing balance mechanisms, sash components, friction devices, or related hardware. Continued use in this condition may contribute to additional wear, operational difficulty, or potential injury if the window closes unexpectedly.
Recommendations:
Have a qualified contractor or window specialist repair the affected window assembly as recommended. Corrective work may include replacing worn balances, adjusting sash alignment, and reviewing nearby windows where similar operational issues may exist.
14.7 Additional Interior Cabinets and Countertops
Cabinet Material: Wood
Countertop Material: Wood
The representative visible cabinetry and countertops were inspected for significant defects related to physical damage, installation, and other readily visible deficiencies. Representative cabinet doors and drawers were operated, where possible, to evaluate proper operation, alignment, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
14.8 Wall Insulation and Air Bypass
Wall Insulation: Not Visible
14.9 Interior Stairs
Interior Stairs If Applicable: Present
The representative visible components of the exterior stair system were inspected by traversing the stairs, where possible, to evaluate their general condition, stability, handrails, guards (where applicable), and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Stairs-Multiple Observations or Improvements
The stair assembly has multiple visible conditions that warrant repair, improvement, or adjustment. While no immediate structural failure was noted at the time of inspection, several aspects of the stair system do not appear fully consistent with modern safety and construction practices. Conditions involving multiple stair components can affect safe use, stability, usability, and long-term performance over time.
Recommendations:
Have a qualified general contractor or experienced carpentry professional perform corrective work as recommended. Repairs may reasonably include addressing individual stair components, improving attachment points, correcting stair geometry or railing concerns, reinforcing structural connections, and making necessary adjustments to support safer and more consistent use. The scope of work may also reasonably include reviewing related or concealed framing and adjacent stair components where similar conditions may exist.
14.10 Indoor Air Quality
Link to Indoor Air Quality: Link to Indoor Air Quality
The following link can provide you with additional information regarding indoor air quality.
https://www.epa.gov/indoor-air-quality-iaq
Ch. 15 Kitchen
15.1
Per the Standards of Practice, the inspector will examine and report on the condition and operation of the dishwasher by initiating a cycle, the range by testing the heating elements and the oven, the mounted microwave by starting a warm-up cycle, test the hot/cold water supply at the fixture, look for leaks in the plumbing and fixtures/faucet, examine counters, walls, ceilings, floors, a representative number of cabinets, windows, doors, and the presence of GFCI receptacles and their operation, if applicable. Homes built prior to 1987 were not required to have GFCI receptacles in the kitchen, but upgrading is recommended for safety.
The home inspector is not required to report on: Clocks, timers, self-cleaning oven functions, thermostats for calibration or automatic operation; Non-built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.
15.2 General Kitchen Pictures
15.3 Sinks and Faucets
Tested
The representative visible components of the sink assembly were inspected for significant defects related to fixture operation, water flow, drainage, faucets, shutoff valves, plumbing connections, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
The representative visible supply and drain piping serving the fixture were inspected for significant defects related to leaks, improper installation, physical damage, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Note:
- Thermal images taken during the inspection did not reveal any signs of active leaks at the time of inspection.
Faucet – Hot Water Handle Orientation
The hot water faucet handle operates in an orientation that differs from what is commonly expected. While the faucet functioned normally, the handle position may be unintuitive for some users and could result in momentary confusion during operation.
No immediate repair is necessary if the current operation is acceptable. If desired, a qualified plumber may adjust the handle orientation to provide a more conventional operating position.
15.4 Cabinets and Countertops
Cabinet Material: Wood
Countertop Material: Granite
The representative visible cabinetry and countertops were inspected for significant defects related to physical damage, installation, and other readily visible deficiencies. Representative cabinet doors and drawers were operated, where possible, to evaluate proper operation, alignment, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
This is a great document From the Natural Stone Institute that covers maintenance and installation recommendations for slab surface stone countertops.
Info and LMT's. Please note that some slab granite has been found to contain radon. Radon testing is beyond the scope of this inspection. Further investigation is required if you are concerned about the health risks associated with this product.
15.5 Disposers
Disposers if Applicable: Operated
The garbage disposal was inspected by operating it with normal controls to evaluate its basic function and identify any readily visible deficiencies, including leakage, an exposed power cord, or excessive corrosion. Garbage disposals are inspected for basic operation only and are not evaluated for grinding performance. No significant deficiencies were identified unless otherwise noted within this section.
15.6 Dishwasher
Dishwasher(s) if Applicable: Present
The representative visible components of the dishwasher were inspected and operated, where possible, using normal operating controls by running a rinse cycle to evaluate its basic function and identify any readily visible deficiencies. No leakage was observed at the base of the appliance upon completion of the cycle. Dishwashers are inspected for basic operation only and are not evaluated for cleaning performance or long-term reliability. No significant deficiencies were identified unless otherwise noted within this section.
15.7 Ranges, Ovens and Cooktops
Heat Source if Applicable: Electric
The representative visible components of the oven and cooktop were inspected and operated, where possible, using normal controls to evaluate their basic operation and identify any readily visible deficiencies. Ovens were tested in the bake mode only. Household appliances are inspected for basic operation as a courtesy and are not evaluated for performance, calibration, or long-term reliability. No significant deficiencies were identified unless otherwise noted within this section.
Note:
- Thermal images taken during the inspection confirm that the ovens were heating properly and did not show any signs of abnormal heat patterns or active issues at the time of inspection.
Missing Range Anti-Tip Device
An anti-tip device is not installed for the cooking range. Anti-tip devices are designed to secure the rear leveling leg of the appliance and help prevent the range from tipping forward if weight is applied to the open oven door. A tipping range may create a significant burn, impact, or spill hazard, particularly for children. This is an important modern safety feature and is commonly required by manufacturers.
Recommendations:
Have a qualified contractor or appliance professional install an appropriate anti-tip device as recommended. Corrective work may reasonably include confirming proper range positioning, securing the appliance in accordance with manufacturer installation guidance, and verifying the anti-tip mechanism is properly engaged to help improve safety and stability.
Key Points:
- This safety feature is commonly required by manufacturers and modern installation standards
15.8 Refrigerators
Refrigerator(s) if Applicable: Present
The representative visible components of the refrigerator were inspected and operated, where possible, using normal operating controls to evaluate their basic function and identify any readily visible deficiencies. Household appliances are inspected for basic operation as a courtesy and are not evaluated for performance, calibration, or long-term reliability. Inspection photographs are provided to document the general condition and apparent operation of the appliance at the time of the inspection. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Refrigerators are examined as a courtesy during a Home Inspection, as they are regarded as transient or "unattached" items. However, they are not relocated to inspect the condition of the flooring beneath them or the surrounding cabinetry. Consequently, the visibility of their water line and power receptacle is limited and excluded from this inspection. If any concerns arise regarding the refrigerator, it is advisable to arrange for an evaluation by an appliance repair company or another qualified professional before proceeding with the closing.
Ice Maker Testing Note
An ice maker was present but not operated. Testing of ice makers is beyond the scope of a standard home inspection, as these components are intermittently used and can leak when reactivated. Confirm proper operation with the seller or during final walk-through if desired.
15.9 Microwave
Microwave if Applicable: Present
The microwave oven was inspected by operating normal controls to evaluate its basic function and identify any readily visible deficiencies. Where equipped with an exhaust feature, the visible venting method and apparent discharge configuration were also considered. No significant deficiencies were identified unless otherwise noted within this section.
Microwave is Close To Cooktop
The microwave is installed with limited clearance above the cooktop. While some installations may still comply with the appliance manufacturer’s minimum clearance requirements, reduced spacing can affect usability, accessibility, and heat exposure during normal cooking activities. Industry recommendations commonly reference approximately 24 inches of clearance above the cooking surface for improved functionality and user comfort, although acceptable clearances ultimately depend on the specific manufacturer’s installation requirements.
Recommendation:
Have a qualified appliance installer or contractor verify that the installation meets the microwave manufacturer’s required minimum clearances and installation specifications. If deficiencies are identified, or if improved usability is desired, corrective work may reasonably include adjusting or reinstalling the appliance to provide additional clearance and improve overall functionality consistent with manufacturer recommendations and modern installation practices.
Key Points:
- Modern installation practices typically recommend minimum separation distances between cooktops and microwave assemblies
15.10 Kitchen Ventilation Method
Ventilation Method if Applicable: Present, Fan Ducted to Exterior
The kitchen exhaust fan was inspected by operating normal controls to evaluate its basic function and identify any readily visible deficiencies. The apparent venting method (recirculating or exterior) was also documented. No significant deficiencies were identified unless otherwise noted within this section.
15.11 General Appliances
Info and LMT's. Appliances are checked for general functionality by turning them on for a short period of time using basic operating modes. Thermostats, timers, clocks, self-cleaning features and other specialized functions are not tested during this inspection. Appliances are not inspected for cosmetic flaws, performance or the ability/accuracy of heating, cooling, etc. They are not inspected to ascertain whether the proper racks and/or accessories are present or in working order. Laundry appliances (and other portable appliances) are not moved and are outside the scope of this inspection; any comments are included for information purposes only. Water supply valves are not operated for liability reasons. It is further recommended that appliances be operated once again during the final walk through inspection prior to closing. Finally, product recalls and consumer product safety alerts occur almost daily. To best address your specific concerns, visit www.cpsc.gov or www.recalls.gov. Items, brand names, and model numbers will be required for proper identification.You may also find some general information or listed recalls on appliances by visiting the following link: https://www.building-center.org/
Info and LMT's. Except for the microwave, kitchen appliances were tested during inspection today. The typical design life of appliances can range from 4-20 years. Some appliances such as an older electric range are simple and tend to last longer than more complex appliances such as dishwashers and refrigerators or modern appliances with circuit boards. It is impossible to predict the useful remaining life of an appliance. I ran appliances during inspection. Any defects noted will be listed in this report.
Ch. 16 Laundry Facilities
16.1
Per the Standards of Practice, the inspector will examine and report on the condition of the exposed plumbing, the presence of a 240-volt receptacle, GFCI receptacles, dryer vent condition, and termination, as well as the walls, floors, ceilings, doors, cabinets, counters, and windows, if applicable.
The inspector is not required to: Inspect or move washers and dryers, operate water valves where the flow end of the faucet is connected to an appliance, or Inspect the plumbing for proper sizing, design, or use of proper materials.
16.2 Laundry Overview Photos
16.3 Washer
Washer: Not Present
Info and LMT's. Washer Drain Line – Not In Use / Not Verified
No washing machine was present at the time of inspection. As a result, the washer drain line was not operated or tested, and its routing, connections, and ability to properly handle discharge could not be confirmed. Inquire with the seller regarding prior use, known issues, and the condition of the washer drain line, and verify proper drainage and leak-free performance once a washer is installed.
16.4 Dryer
Dryer: Not tested
Power Source: Electric
Exhaust Duct: Ducted to Exterior
Info and LMT's. Washer and Dryer (Limited Scope)
Washers and dryers are not tested as part of this inspection and fall outside the scope of a standard home inspection. Their performance depends on internal components, proper installation, and utility connections that are not fully assessed. In addition, the washer’s supply and drain connections are not tested, and the functionality of the drain is excluded from this inspection. Verification of operation and plumbing performance should be confirmed with the seller or through a separate appliance or plumbing review, if desired.
Info and LMT's. Dryer Exhaust Vent (Limited Visibility)
Portions of the dryer exhaust vent are concealed within wall and/or ceiling cavities and were not fully visible. As a result, the routing, support, connections, termination, and materials used in concealed sections could not be confirmed. If improper or non-recommended materials are present in these concealed areas—such as foil or Mylar flex duct, plastic ducting, thin vinyl ducting, or similar non-metal materials—they should be removed and replaced with smooth-wall or listed corrugated metal ducting in line with modern safety and manufacturer standards.
Concealed dryer vent conditions are a common source of airflow restriction and lint accumulation, which can increase fire risk. Verification and correction, if needed, should be performed by a qualified contractor familiar with proper dryer venting practices.
Dryer Vent Cleaning Note
Periodic cleaning of the dryer exhaust duct is recommended as part of normal home maintenance. Lint accumulation within the duct can restrict airflow, reduce dryer performance, and increase the potential for overheating or fire.
The maintenance history of the dryer exhaust duct could not be determined during the inspection. Consider cleaning the duct after taking possession if recent professional cleaning cannot be confirmed.
Vertical Dryer Vent Note
The dryer vent is routed vertically from the appliance to the exterior. Vertical dryer vents are acceptable when installed properly, but they may reduce airflow efficiency compared to horizontal or short runs. Proper installation, venting to the exterior, and regular cleaning are recommended to maintain dryer performance and reduce fire risk.
Dryer Vent – Missing Backdraft Damper
The exterior dryer vent is missing a backdraft damper. Without a functioning damper, outside air, moisture, pests, and debris can enter the duct system and may contribute to airflow concerns or deterioration of the vent assembly over time.
Recommendations:
Have a qualified contractor replace the exterior dryer vent termination with an approved assembly that includes a properly functioning backdraft damper. Verify the vent is securely installed, unobstructed, and operating as intended after repairs are completed.
Dirty Dryer Exhaust Vent
Excessive lint accumulation was present within the dryer vent system. Lint buildup can restrict airflow, reduce drying efficiency, increase appliance operating temperatures, and contribute to an elevated fire risk. Restricted dryer vents may also increase wear on the appliance and allow excess moisture to remain within the vent system.
Recommendations:
Have the dryer vent professionally cleaned and serviced as recommended. The scope of work may reasonably include cleaning the entire vent system, verifying proper airflow, inspecting the vent termination, and assessing related vent components where lint accumulation or restrictions may exist.
Improper Material at Dryer Vent Connection
Non-approved tape or similar material is present at the dryer vent connection. These materials can deteriorate or loosen over time, allowing lint and moisture to escape and potentially reducing the reliability of the exhaust connection. Dryer exhaust systems should remain securely connected and use materials appropriate for the heat and conditions associated with dryer operation.
Recommendations:
Have a qualified dryer vent professional or HVAC contractor remove the improper material and properly secure and seal the connection using approved materials suitable for dryer exhaust systems. The accessible venting should also be reviewed for loose connections, damage, excessive lint accumulation, or similar conditions, with repairs completed as needed to support proper airflow and safer operation.
16.5 Laundry Ventilation
Type: Not Present
Laundry Room Ventilation
No dedicated mechanical exhaust ventilation was present in the laundry room. This configuration is common in some older homes and no related moisture concerns were observed at the time of the inspection.
Normal ventilation and humidity control should be maintained during laundry use. Mechanical ventilation may be considered as a future improvement if desired.
Ch. 17 Bathroom Finishes
17.1
Per the Standards of Practice, the inspector will examine and report the condition of the: sinks, showers, tubs, enclosures, toilets, exposed plumbing, and the presence of leaks from plumbing, fixtures, and/or faucets. As well as the walls, floors, ceilings, a representative number of windows and doors, heating/cooling source, ventilation, and presence of GFCI protection, if applicable. GFCI protection in bathrooms was not required in homes built prior to 1975, but upgrading is recommended for safety.
The home inspector is not required to: Operate any valve except water closet flush valves, fixture faucets, and hose faucets; or Inspect the system for proper sizing, design, or use of proper materials.
Basement Bathroom – Rough / Unfinished Installation
A very rough and substantially unfinished bathroom installation is present in the basement. The area appears to have been assembled or modified over time and should not be considered a conventionally finished or fully functional bathroom based on its current condition. Plumbing, electrical, ventilation, finishes, fixtures, and other components may require significant modification or replacement if the area is intended to remain in use.
Given the overall condition and limited nature of the installation, the client may wish to consider removal of the existing bathroom rather than attempting to repair or improve the individual components. If the bathroom is to remain, have qualified contractors evaluate the installation as a whole and complete improvements as needed before regular use.
17.2 Bathroom Overview Photos
General Pictures
General Bathroom Pictures
17.3 Sinks and Cabinets
Tested
The representative visible sink components were inspected by operating the faucets, shutoff valves, and other accessible controls, where possible, to evaluate their basic function and identify any readily visible deficiencies. Water was run through the drain system to evaluate functional drainage and check for visible leakage at the fixture, supply connections, drain assembly, and accessible areas below. No significant deficiencies were identified unless otherwise noted within this section.
The visible sink plumbing was inspected by running water through the drain system for over one minute to evaluate drainage and check for readily visible leakage at the drain assembly, supply connections, and accessible areas below the fixture. The visible plumbing was also evaluated for other readily apparent deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Note:
- Thermal images taken during the inspection did not reveal any signs of active leaks at the time of inspection.
17.4 Toilets
The representative visible toilets were inspected by flushing them to evaluate their basic function and identify any readily visible deficiencies. The fixtures were also checked for visible leakage at the tank, supply connections, and base. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Toilets are not forcefully manipulated or tested for attachment to the closet flange. Obvious movement observed during normal operation or light incidental contact may be reported.
Toilet – Loose
The toilet is loose at the floor connection. Toilets are intended to be securely fastened to maintain stability and preserve a proper seal at the waste connection. Movement at the base may compromise the wax seal and can allow leakage beneath the fixture, potentially contributing to concealed moisture intrusion, subfloor deterioration, microbial growth, or damage to surrounding finishes over time. Concealed conditions beneath the fixture could not be fully determined without removal of the toilet.
Recommendations:
Have a licensed plumbing contractor perform corrective work as recommended. Corrective work may reasonably include resetting the toilet, replacing the wax seal or sealing components as needed, confirming flange condition and attachment integrity, and assessing adjacent flooring or concealed subfloor areas where moisture-related deterioration or damage may exist.
Key Points:
- Loose toilets may compromise the waste seal beneath the fixture
- Hidden leakage can contribute to subfloor and flooring deterioration
Toilet Not Caulked to Floor
The toilet is not sealed to the floor with caulking at the base. A missing seal can allow moisture, cleaning water, dirt, or debris to collect beneath or around the fixture. Over time, this condition may contribute to deterioration of surrounding flooring materials or make it more difficult to identify minor leakage conditions at the toilet base.
Recommendations:
Have the toilet base properly sealed as recommended. Corrective work may reasonably include applying an appropriate bead of caulk at the floor-to-fixture joint, confirming the fixture is stable and properly seated, and reviewing the surrounding flooring area where needed to help maintain a more complete and moisture-resistant installation.
Toilet-Running
The toilet continued to run after flushing, indicating that components within the tank are not operating or sealing properly. A continuously running toilet can waste water and may worsen as internal components wear or deteriorate.
Recommendations:
Have a qualified plumber evaluate and repair the toilet as recommended. Corrective work may reasonably include adjustment or replacement of the flapper, fill valve, flush valve, chain, seals, or other internal tank components as needed to restore proper operation. Replacement of the toilet may be appropriate if components are significantly worn or repairs are not practical.
17.5 Bathtub / Shower / Bathtub Walls and Enclosures
The representative visible shower and tub components were inspected by operating the fixtures, where possible, to evaluate their basic function, water flow, drainage, and identify any readily visible deficiencies. Water was run through the fixtures for several minutes while accessible areas, including the enclosure, walls, door, drain assembly, and areas below (where accessible), were checked for visible leakage or conditions that could permit water intrusion. Occupant use and long-term water exposure cannot be fully replicated during a visual home inspection. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Water was allowed to flow through the drains of tubs and showers for an extended duration, followed by an inspection of the areas beneath these drains (if applicable) using thermal imaging to detect any signs of leaks. No leaks were detected during the inspection unless specifically mentioned in this report.
It's important to note that the effects of weight applied to these drains cannot be replicated during the inspection. When individuals shower or bathe, the weight can exert pressure on gaskets or joints in the drain pipes, potentially leading to leaks. This risk may be heightened in homes that have been unoccupied for an extended period. Therefore, any leaks occurring from these areas after the inspection are not covered.
Info and LMT's. Tub and sink overflows are not assessed for functionality during testing, as there is a high probability that the gaskets may leak. Therefore, it is advisable to be cautious when filling tubs to prevent water from entering the overflow. While these overflows typically help drain away excess water, some degree of leakage should be expected. To address this issue, it is recommended to have a licensed plumber inspect the gaskets and perform any necessary repairs. It should be assumed that these overflows may not be completely watertight.
Unable to verify water proofing materials.
Bathtub and shower floors, as well as walls above built-in tubs with showerheads, must be made of smooth, corrosion-resistant, and nonabsorbent waterproof materials. Walls must extend at least 6 feet (1829 mm) above the room floor or 70 inches (1778 mm) above the drain, whichever is greater, forming a watertight seal with the tub or shower floor.
For field-constructed enclosures, IBC (Sections 2509.2 and 1210.3)regulate materials. Tile backings must be glass mat water-resistant panels, non-asbestos fiber-cement, or fiber-mat-reinforced cement sheets. Above the required height, water-resistant gypsum board may be used. When used within tub or shower compartments (including ceilings), vapor barriers are prohibited. Ceiling installation requires 1/2-inch (12.7 mm) board with 12-inch (305 mm) spacing or 5/8-inch (15.9 mm) board with 16-inch (406 mm) spacing.
For proper waterproofing installation, see this link Water Proofing Shower Walls
Inoperable Shower Diverter
The shower diverter is inoperable and does not properly direct water between the tub spout and showerhead. This limits normal use of the tub / shower and may be related to a worn or damaged diverter or other components within the fixture.
Recommendations:
Have a qualified plumbing contractor repair or replace the shower diverter as needed. Verify proper water flow and operation at both the tub spout and showerhead after repairs are completed.
Bathroom Caulking Deficiencies – Multiple Locations
Caulking deficiencies are present at one or more bathroom fixtures and finish surfaces. Conditions may include missing, deteriorated, cracked, separated, improperly applied, or incomplete caulking at tubs, showers, sinks, backsplashes, countertops, or other moisture-prone areas. These openings may allow water to bypass finished surfaces and contribute to moisture intrusion, concealed deterioration, damage to adjacent materials, and conditions conducive to microbial growth over time.
Recommendations:
Have a qualified contractor remove deteriorated sealant and properly recaulk affected areas as recommended. Corrective work may include cleaning surfaces, addressing moisture-damaged materials where present, and assessing similar joints and transitions throughout the bathroom where comparable conditions may exist.
Key Points:
- Failed sealant can allow moisture intrusion and hidden deterioration.
Incomplete or Disconnected Bathtub Stopper
The bathtub stopper is incomplete, disconnected, or not functioning as intended, preventing the tub from retaining water for normal bathing use. While this condition does not appear to affect normal drainage performance, it limits the intended functionality of the bathtub and may indicate wear, missing components, or deterioration within the drain stopper assembly.
Recommendations:
Have a qualified contractor, plumber, or appropriate repair professional perform corrective work as recommended. Repairs may reasonably include reconnecting or replacing the bathtub stopper assembly, adjusting related drain components, confirming proper fit and operation, and reviewing associated drain hardware where similar wear or installation concerns may exist.
Tub / Shower Fixture – Active Leak
An active leak was present at the tub/shower fixture at the time of the inspection. Active plumbing leaks can contribute to moisture intrusion, damage to surrounding finishes, concealed deterioration, and conditions conducive to microbial growth. The source of the leak may involve fixture components, supply connections, valves, seals, or concealed plumbing components.
Recommendations:
Have a licensed plumber perform corrective work as recommended. Repairs may include replacing defective fixture components, valves, cartridges, seals, supply connections, or other plumbing components contributing to the leak. The scope of work may reasonably include assessing adjacent finishes, concealed areas, and related plumbing components where moisture-related damage or similar conditions may exist.
17.6 Bathroom Ventilation
Type: Bath fan
The representative visible bathroom exhaust fan(s) were inspected by operating normal controls to evaluate their basic function and identify any readily visible deficiencies. The apparent discharge method, where visible, was also considered. No significant deficiencies were identified unless otherwise noted within this section.
Bath Fan Note
Bathroom exhaust fans typically last 10 to 15 years with normal use and maintenance.
Bath Fan(s) Old-Updating Recommended
The bathroom exhaust fan(s) are older but operating at the time of inspection. Older fans may not move air as efficiently as modern units and can become noisy or less effective over time. Consider upgrading to modern, higher-efficiency models as desired to improve ventilation performance and meet current standards for moisture control.
17.7 General Bathroom Finishes Condition
Info and LMT's. Bathroom Plumbing and Moisture Note
Plumbing fixtures in the bathrooms were operated at the time of inspection. Representative areas around toilets, tubs, showers, and accessible tile enclosures were checked for signs of active leakage, moisture-related concerns, loose finishes, or deteriorated tile conditions using normal inspection methods, including limited moisture meter testing and sounding of accessible surfaces where appropriate.
Bathtub overflow drains are not intentionally filled or tested during a home inspection because concealed overflow gaskets and plumbing connections may leak when subjected to prolonged water exposure. These components are generally concealed and their condition cannot be fully evaluated during a visual inspection. Monitor overflow areas during normal use and have a licensed plumber evaluate any leakage or concerns that develop.
Plumbing systems in vacant homes may present additional uncertainty, as limited fixture operation during an inspection does not fully replicate normal daily use conditions. Continued monitoring of plumbing fixtures, drains, and surrounding finishes is recommended after occupancy. Any visible deficiencies identified at the time of inspection are included elsewhere within this report.
Ch. 18 Attic, Roof Structure and Ventilation
18.1
Per the Standards of Practice, the inspector will examine: the attic area and report on the condition of the access opening (including location), insulation type (and current depth), ducts, visible electrical components, exhaust terminations, plumbing components, and ventilation if applicable.
The inspector is not required to: move or disturb insulation, report on the adequacy of current ventilation, or Calculate the strength, adequacy, or efficiency of any system or component, including framing. Enter any attic that may damage the property or its components or be dangerous to or adversely affect the health or safety of the home inspector or other persons. Therefore, I do not attempt to enter attics with less than 36" of headroom, where insulation obscures the ceiling joists, or where ducts block access. In these cases, I will evaluate from the access opening as best I can.
18.2 Attic Overview Photos
Info and LMT's. It is recommended to inspect all attic spaces at least twice annually to ensure that ventilation openings remain unobstructed and to prevent the development of mold. While there may be minimal or no visible evidence of organic growth during the inspection, mold can proliferate rapidly under favorable conditions. Organic growth poses potential hazards and can spread when moisture accumulates in the attic and is not properly vented to the exterior. Any areas of concern should be examined by a qualified contractor for analysis and appropriate removal measures.
Info and LMT's. Every effort is made to access and navigate all attics safely and thoroughly. Details regarding the inspection method used, including the approximate percentages of the attic that were both physically and visually accessible, will be provided, along with any safety concerns or obstacles that may have limited the inspection.
The method of inspection is determined solely by the inspector and is influenced by various factors, including accessibility, clearance, insulation levels, stored items, temperature, and more. It's important to note that the inspection is confined to visible areas only, and any sections that were not visually accessible are not included in the assessment.
It's essential to recognize that hidden damage may exist, as no attic can be entirely evaluated due to physical and visible obstructions such as insulation, which is not disturbed during the inspection for visual access to items.
18.3 Attic Access
Hatch Location: Bedroom, Closet
Method Of Inspection: Walked
Percentage of Attic that could be Safely Traversed: 90%
The attic access(es) were inspected by evaluating their location, type, and general condition while identifying any readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Attic Access Hatch – Insulation / Weather Stripping Needed
The attic access hatch is not properly insulated and/or weather-stripped. Conditions such as these can allow unwanted air movement between the attic and living space, contributing to heat loss, reduced energy efficiency, inconsistent indoor temperatures, and increased potential for moisture-related concerns in some seasonal conditions. Attic access openings are commonly improved to help better separate conditioned and unconditioned spaces.
Recommendations:
Have a qualified contractor, insulation specialist, or handyman improve the attic access hatch as recommended. Corrective work may reasonably include installing insulation, weather stripping, draft sealing materials, hatch retainers, and related air-sealing improvements to help reduce conditioned air loss and improve thermal separation consistent with modern energy-efficiency practices. The scope of work may also reasonably include reviewing adjacent attic insulation conditions where similar deficiencies may exist.
18.4 Roof Framing and Sheathing
Rafters: 2x6
Sheathing: Skip sheathing
A representative sample of the visible portions of the roof structure were inspected for readily visible signs of moisture intrusion, damage, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Previous Moisture Staining – Attic
Moisture staining is present on portions of the attic framing and/or roof sheathing, indicating previous moisture exposure. The affected areas appeared dry at the time of the inspection, and no evidence of active leakage or elevated moisture was identified unless otherwise noted within this report. While the source of the staining may have been corrected, conditions can change over time. Periodic observation of the area, particularly following heavy rainfall or seasonal weather changes, is recommended, and any future signs of active moisture should be addressed promptly.
Older Attic-No Red Flags.
The attic structure consists of a mix of framing techniques and materials, likely reflecting modifications or repairs over time. While the overall structural integrity appears adequate for current conditions, the framing exhibits inconsistencies, including varied lumber sizes, unconventional connections, and non-uniform spacing. There is no immediate concern based on today's inspection; however, future renovations or heavy loads may warrant further evaluation by a qualified contractor to ensure long-term stability. Regular monitoring is recommended to identify any developing issues.
Older Plank / Shiplap Roof Decking
Older plank / shiplap-style roof decking is present. Some spacing is visible between individual boards, which is common with this type and age of roof construction. No determination is made as part of this inspection regarding whether the existing decking met the roof-covering manufacturer’s installation requirements at the time the roofing was installed.
When future roof replacement or significant repairs are completed, the roofing contractor should evaluate the exposed decking for condition, spacing, thickness, and suitability for the selected roofing material. Repairs, replacement, or installation of additional sheathing may be recommended at that time based on the condition of the decking and applicable installation requirements.
Damaged Roof Sheathing
Roof sheathing is damaged at a visible location. Deteriorated sheathing can reduce support for the roofing materials and is commonly associated with prolonged moisture exposure or other conditions affecting the roof assembly. The full extent of the damage could not be determined because concealed portions of the roof structure are not visible during a visual home inspection.
Recommendations:
Have a qualified roofing contractor repair the affected area as recommended. Corrective work may reasonably include removing roofing materials as needed to replace damaged sheathing, identifying and correcting the source of the deterioration, restoring associated flashing or underlayment where applicable, and assessing adjacent roof areas for similar conditions or concealed damage that may become visible during repairs.
18.5 Fire Separation
Info and LMT's. Attic Visibility. Some areas of the attic were obstructed by insulation or other materials, which prevented a full view of vent penetrations and potential fire-stopping. The inspection is therefore limited to visible areas only.
18.6 Attic Insulation
Attic Insulation Type: Fiberglass
Insulation Depth: 3
Approximate Insulation R-Value on Attic Floor: Improve to Modern Standard
Approximate Insulation R-Value on Attic Ceiling: Not needed
Approximate Insulation R-Value on Attic Walls: Not needed
Representative areas of the visible attic insulation were inspected to identify the apparent insulation type, estimate the approximate depth, and identify any readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Attic Insulation – Improvement Recommended
The attic insulation level appears lower than what is commonly recommended for modern energy efficiency in this climate region. Limited insulation can allow increased heat loss during colder weather and heat gain during warmer months, which may reduce indoor comfort, contribute to uneven interior temperatures, and increase heating and cooling demands over time. In colder climates such as Central Ohio, insufficient attic insulation may also contribute to ice damming potential and seasonal condensation concerns under certain conditions.
Recommendations:
Have a qualified insulation contractor or appropriate professional complete recommended insulation improvements. Corrective work may reasonably include adding insulation to accessible attic areas, improving insulation distribution, addressing accessible air leakage pathways, and reviewing attic ventilation conditions where practical to help support improved thermal performance and overall energy efficiency consistent with modern practices.
18.7 Attic and Roof Cavity Ventilation
Attic Ventilation Method: Gable vents, Soffit vents, Roof jack vents
Attic / Roof Ventilation
Visible attic and roof ventilation components were inspected for general condition, distribution, and readily apparent restrictions. Proper ventilation can help manage attic heat and moisture and support the long-term performance of roofing and building materials.
Ventilation needs vary based on attic configuration, insulation, air sealing, roof design, and other conditions. A home inspection does not include calculations or testing to determine whether the ventilation system provides a specific amount of airflow. Significant deficiencies, blocked vents, or other readily visible ventilation concerns will be reported separately when observed.
Attic / Roof Cavity Ventilation – Non-Standard
The attic and roof cavity ventilation configuration appears non-standard and may not be consistent with commonly accepted modern ventilation practices. Attic ventilation systems are intended to help manage heat, moisture, and air movement within the attic space. Non-standard ventilation arrangements may reduce airflow effectiveness, contribute to elevated attic temperatures, increase the potential for condensation, and potentially shorten the service life of roofing materials and related components. The long-term performance of attic ventilation depends on proper intake, exhaust, and overall airflow balance.
Recommendations:
Have a qualified roofing contractor, insulation contractor, or attic ventilation specialist review the ventilation system and perform corrective work as recommended. The scope of work may reasonably include reviewing ridge vents, soffit vents, roof vents, gable vents, insulation placement, airflow pathways, and related attic conditions where similar limitations may exist.
Note:
- Mixed Attic Venting Methods. The attic ventilation system includes both gable vents and roof-mounted vents operating within the same roof cavity. Using mixed ventilation methods can reduce overall airflow efficiency if the system is not properly balanced, as air may short-circuit between vents rather than move through the attic as intended.
Ch. 19 Foundation, Structure and Basement
19.1
Per the Standards of practice, the inspector will examine and report on the condition of the foundation walls, the framing (including probing of any framing that looks to have damage/deterioration), columns/piers, and insulation if applicable.
The inspector is not required to: enter any area that could be considered a safety hazard to the inspector; report on the adequacy of structural components; or report on spacing, span, or size of structural components. Ductwork, framing, plumbing, and insulation may block the visual accessibility of some areas. The inspection is limited to the conditions on the inspection day; I inspect several items looking for indications that moisture has infiltrated the foundation area. But, I cannot guarantee that water will not infiltrate the area at a future time due to conditions unforeseen at the time of inspection.
19.2 Foundation
Building Configuration: Basement
Foundation Description: Masonry block
Estimated Percentage of Visible Foundation: 60%
Evidence of Seismic Protection or Foundation Reinforcements: I Beams, Wall Anchors, Tie Backs or C Channels Note, Previous Repairs
A representative number of the visible portions of the foundation walls were inspected to evaluate their general condition and identify any readily visible signs of cracking, moisture intrusion, damage, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Foundation & Basement Inspection Scope
A representative sample of the visible and readily accessible foundation, structural, and below-grade components was inspected for significant deficiencies, including signs of structural movement, damage, and moisture intrusion. Finished walls, ceilings, floors, stored belongings, insulation, and other concealed conditions limited visibility of many structural components, including portions of the foundation, framing, subflooring, and the foundation footing, which is typically concealed below grade and was not visible.
No evidence of active water intrusion or moisture-related concerns was identified in the visible areas at the time of the inspection unless otherwise noted within this section.
Recently Painted Foundation Walls
The foundation walls appear to have been recently painted. Fresh paint can improve appearance but may also limit visibility of prior moisture staining, repairs, or cracking. Because coatings can conceal underlying conditions, the ability to fully assess the wall surface was somewhat limited.
Buyers should be aware that painted masonry surfaces may require ongoing monitoring for signs of moisture intrusion, movement, or deterioration consistent with age and construction type.
Foundation – Previous Repairs / Condition Needing Further Review
Substantial cracking and extensive previous repair work were noted at portions of the foundation walls. The amount of repair work indicates that the foundation has experienced conditions significant enough to warrant corrective work in the past; however, the original extent of movement, reason for the repairs, methods used, and long-term performance of those repairs cannot be determined through a visual home inspection alone.
Portions of the foundation walls also appear to have been recently painted. The newer coating limits visibility of previous staining, cracking, patching, moisture conditions, or other evidence that may otherwise help establish the history and performance of the foundation. While substantial repairs have clearly been completed, no determination is made regarding whether previous movement has fully stabilized or whether additional movement may occur.
Recommendations
Request all available information regarding the previous foundation repairs, including contractor documentation, engineering reports, invoices, permits where applicable, and particularly any warranties or guarantees that may transfer to the new owner. Documentation should be reviewed to better understand the original conditions, scope of repairs, and whether any continued monitoring or maintenance is required.
If adequate documentation cannot be provided, warranties cannot be verified, or concerns remain regarding the substantial cracking or previous repairs, further evaluation by a qualified structural engineer or foundation specialist is recommended. Continue to monitor the repaired and cracked areas for measurable changes, renewed cracking, displacement, or moisture conditions.
19.3 Floor, Wall and Ceiling Framing
Wall Framing: Not Visble
Wall Sheathing: Not visible
Floor Framing: Partly visible, 2x10
Sub-Floor Material: Partly visible, Shiplap
Ceiling Framing: Not visible
Floor, Wall and Ceiling Framing Visual Obstructions: HVAC Ductwork
A representative portion of the visible and accessible structural components were inspected to evaluate their general condition and identify any readily visible damage or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Only portions of the exterior wall structure, floor framing, and ceiling framing were visible to inspect; the remaining areas were not visible.
Floor Joist Notched-OK
The floor joists have been notched at the floor framing system. The notching looks to be less than 1/3 of the joist depth and notches are allowed on the ends of joists. This also seems to have performed well to date. I do not see anything worth correcting at this time, however it should be monitored over time if correction may be needed.
Floor Joists Cut Without Proper Framing Support
One or more floor joists have been cut or altered without the installation of proper headers, trimmers, or other framing intended to transfer structural loads. Floor framing members are designed to work together as a structural system, and improperly supported modifications may reduce the load-carrying capacity of the floor, contribute to excessive deflection, uneven floors, or place additional stress on adjacent framing components. The full extent of concealed structural modifications cannot be determined during a visual home inspection.
Recommendations:
Have a qualified framing contractor or structural professional perform corrective work as recommended. The scope of work may reasonably include installing appropriately sized headers and trimmer joists, reinforcing or replacing altered framing members as necessary, verifying adequate load transfer, and assessing adjacent or concealed framing where similar modifications or deficiencies may exist to support safe, reliable, and long-term structural performance.
Key Points:
- Cut joists require proper framing to safely transfer structural loads.
- Improper alterations may contribute to floor deflection, unevenness, and overstressing of adjacent framing.
- Proper structural repairs help restore the strength and long-term performance of the floor system.
19.4 Basement Overview Photos
Description: Full
Info and LMT's. This basement was inspected visually, evaluating what is observable and reasonably accessible at the time of the inspection.
As is generally true for below-grade spaces, conditions such as moisture intrusion, structural movement, or concealed defects can sometimes only become apparent under specific circumstances — for example, during or after heavy rain, snowmelt, or seasonal changes in groundwater. A visual inspection reflects conditions on the day of inspection and doesn't predict how the space will perform under different weather or seasonal conditions.
Egress Window Note
This basement does not have an egress window. In Ohio, egress windows are only required in basements that contain a sleeping room, and since no bedroom is present in this area, an egress window isn't a requirement here under current residential guidelines.
If a basement bedroom is added in the future, an egress window (or another approved emergency escape opening) would then be needed to meet safety standards for sleeping rooms.
19.5 Slabs and Concrete Floors
Slab Type: Concrete
The visible portions of the concrete slab were inspected for readily visible signs of significant cracking, damage, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Concrete Slab – Large Crack
A larger-than-typical crack is present in the concrete slab. While cracking in concrete is common, the size and pattern of this crack suggest movement or stress within the slab that may continue to change over time. The slab appeared serviceable at the time of inspection; however, the long-term significance or future movement potential of concrete cracking cannot be determined through a visual inspection alone.
Recommendations:
Have the crack evaluated and repaired as recommended. Corrective work may reasonably include determining whether the crack is stable, sealing or repairing the crack as appropriate, addressing any contributing conditions if identified, and evaluating adjacent slab areas where similar movement may exist.
Key Points:
- Larger concrete cracks may indicate movement or stress within the slab
- Seasonal moisture and freeze/thaw conditions can contribute to continued movement
19.6 Basement Moisture
Moisture Present if Applicable: Present
Dehumidifier Present
A dehumidifier was present in the crawl space/basement at the time of the inspection. Dehumidifiers are commonly used to help manage humidity levels and reduce excess moisture, particularly in below-grade or enclosed areas. Its presence does not necessarily indicate an active moisture concern; however, continued operation and routine maintenance may help support long-term moisture control and protect building materials.
High Humidity Levels – Basement
Elevated humidity levels were noted within the basement at the time of inspection. Excess moisture in basement environments can contribute to musty odors, condensation, material deterioration, wood movement, microbial growth conditions, and reduced indoor comfort over time. Basement humidity levels may fluctuate seasonally and are commonly influenced by drainage conditions, ventilation, foundation moisture intrusion, groundwater conditions, and HVAC performance.
Take steps to improve basement moisture management and humidity control as recommended. Corrective work may reasonably include drainage improvements, dehumidification, ventilation adjustments, and reviewing foundation or basement areas where additional moisture intrusion or elevated humidity conditions may exist.
Previous Water Staining in Basement
Water staining is present on portions of the basement, indicating previous moisture exposure. The affected areas appeared dry at the time of the inspection, and no evidence of active water intrusion was noted where visible. Basements are subject to seasonal moisture conditions, particularly during periods of prolonged rainfall, groundwater changes, or snowmelt. While the staining appears consistent with past conditions, future moisture intrusion cannot be predicted. Maintaining proper exterior drainage, grading, gutters, downspout extensions, and other moisture-management measures can help reduce the potential for recurring moisture-related concerns.
Ch. 20 Crawl Space
20.1 General Crawl Space
Crawl Space: Present
The photos provided here show representative images of this crawl space at the time of inspection.
Ch. 21 Cracking, Settlement and Movement
21.1
Cracking, Settlement and Movement if Applicable: Note
Exterior Hardscapes & Flatwork: Present
Exterior Walls: None Present on the Day of Inspection
Interior Area(s): Present
Foundation Walls: Present
Slabs: Present
Cracking, Settlement and Movement – General Information
Cracking, settlement, and movement are common findings in residential construction and may be present in foundations, concrete slabs, masonry, interior finishes, exterior materials, and other building components. The presence of cracking alone does not necessarily indicate an active structural problem. The significance of a crack depends on several factors, including its location, size, pattern, displacement, surrounding conditions, age, and whether movement is ongoing.
This inspection includes a visual review of readily accessible areas for visible indications of cracking, settlement, displacement, or movement. Conditions observed during the inspection are documented elsewhere within this report when considered significant or when additional repair, monitoring, or evaluation is recommended.
A home inspection represents a snapshot of conditions at the time of inspection. Without historical measurements or long-term observation, it is generally not possible to determine when a crack first developed, whether previous movement has stabilized, or whether additional movement may occur. Finished surfaces, repairs, paint, sealants, stored belongings, landscaping, and below-grade construction may also conceal evidence of previous or ongoing conditions.
Older homes commonly exhibit some degree of settlement, irregularity, cracking, or movement associated with age, original construction methods, soil conditions, seasonal moisture changes, and decades of normal building performance. These conditions should be considered in the context of the home's age and overall visible performance rather than evaluated solely by the presence of cracking.
Previous repairs, reinforcement, patching, waterproofing, or other corrective work may indicate that cracking, movement, settlement, or moisture concerns existed in the past. When substantial previous repairs are present, clients are encouraged to obtain available contractor information, engineering documentation, permits where applicable, invoices, and warranties or guarantees that may transfer with the property.
Cracks and repaired areas should be periodically monitored for meaningful changes such as widening, displacement, renewed cracking, moisture intrusion, or related changes to surrounding building components. Conditions showing significant displacement, apparent recent movement, substantial cracking, structural alteration, or other concerning characteristics may warrant further evaluation by an appropriately qualified contractor, foundation specialist, or structural engineer as specifically recommended elsewhere in this report.
Important Note
This inspection does not include structural engineering, soil analysis, invasive investigation, historical movement measurements, or determination of the remaining structural capacity of building components. No prediction or guarantee can be made regarding future settlement or movement. Recommendations provided for specific cracking or structural conditions within this report should take precedence over this general informational statement.
Ch. 22 Thermal Imaging
22.1 Thermal Images
An infrared camera was used selectively to examine specific areas of concern or to help validate suspected issues. Its use should not be interpreted as a comprehensive thermal survey of the entire structure. Deployment of the infrared camera was at my discretion to provide additional insight, and its application goes beyond the standard scope of a home inspection.
Temperature readings shown on thermal images are provided as a courtesy and should not be solely relied upon. They are intended as qualitative indicators rather than precise measurements, and actual temperatures may vary by +/- 2% or more. Some readings reflect surface temperatures only, and obtaining air or internal temperature measurements is beyond the scope of this inspection.
Ch. 23 Environmental Information
23.1 Moisture, Water Penetration and Active Leaks
I inspected all visible and accessible areas for evidence of moisture intrusion or conditions that could contribute to moisture-related issues. At the time of inspection, no active moisture or leaks were observed, and all areas appeared to be performing as intended. These observations are limited to the conditions present at the time of inspection. Any future signs of moisture, damage, or related concerns may require further assessment by qualified professionals.
23.2 Mold and Bio-Growth
Please note that mold testing and indoor air quality assessments are beyond the scope of this inspection. If there are concerns about bio-growth or indoor air quality, I recommend evaluation by a qualified specialist. In general, localized issues can often be addressed by removing or sealing the affected area. Best practices for controlling bio-growth focus on diagnosing and repairing water problems. Where water issues are chronic, bio-growth can be more complex and costly to remediate. Where water problems are isolated, mold-related repairs tend to be limited in scope and less complex.
23.3 Pest/Insects/Wildlife Concerns: WDI / Termite Information and Exclusions
Environmental Hazards and Pest/Wood-Destroying Insect (WDI) Disclaimer:
As a home inspector, I do not assess or test for environmental hazards or pest infestations. Specifically, this inspection does not include:
- The presence of mold, mildew, fungus, or airborne contaminants.
- The identification of rodents, animals, bats, guano, or insects, including wood-destroying insects (WDIs).
- Air quality assessments.
- The presence of hazardous materials such as asbestos, lead-based paint, or other environmental risks.
- Hazardous waste conditions or contamination.
Pest & Wood-Destroying Insect (WDI) Concerns:
This inspection does not include an evaluation for the presence of pests, including wood-destroying insects such as termites, carpenter ants, or powderpost beetles. Nothing related to pests or WDI activity was visible on the day of inspection unless otherwise noted in this report. Any such mentions included in the report are based solely on a visual assessment and are strictly provided as recommendations, not a formal pest inspection.
If concerns regarding potential pest activity exist, I strongly recommend:
- Consulting a licensed pest control or WDI specialist to inspect and assess the entire building structure for pest activity or damage.
- Understanding that any informal mention of pest-related issues during this inspection is provided as a courtesy only and should not be interpreted as a formal pest inspection. A professional evaluation is still necessary.
For all environmental hazards or wood-destroying insect concerns, please seek a qualified specialist to perform a dedicated inspection.
Ch. 24 Checking Out Procedure
24.1 Check Out List
Heating and Cooling: Restored to Pre-inspection temperatures
Oven: Off
Appliances: Off / finishing cycle
GFCI Reset: Reset
Lights: Off
Keys and Lockbox: Replaced
Pictures showing appliances are off/finishing cycle
All accessible GFCI outlets were tested during the inspection. Each outlet was reset to its operational state before leaving the property.
24.2 Verbal Consultation
In person
24.3 One Year Follow Up
Once you approach the one-year mark of the purchase of your new home. A one-year inspection is a proactive measure to ensure the continued well-being of your property and identify any potential issues that may have arisen since the initial assessment. If you wish to have this completed, please contact me for details at: 1-614-296-3721 or schedule online at olonzoinspections.com
Ch. 25 Additional Reports
25.1 Ancillary (Third Party Inspections). If Additional Services Were Completed They Will Show Below
Third-Party Inspection Reports
If additional inspections or testing, such as wood-destroying insect (WDI), radon, well and septic, air quality, sewer scope, or laboratory evaluations, are requested, the findings are documented in separate reports prepared by the respective licensed or qualified professionals performing those services. For client convenience, those reports may be delivered alongside this home inspection report or attached within the same report package.
These inspections are not performed by Olonzo Inspections and are scheduled solely as a courtesy to the client(s). Olonzo Inspections does not supervise, direct, control, or verify the methods, findings, conclusions, recommendations, or reporting provided by these independent entities. Any questions regarding their inspection results, recommendations, or scope of work should be directed to the company that performed the service.
The inclusion of a third-party report within the same delivery package is provided solely for convenience and organization. It does not incorporate that report into this home inspection, nor does it constitute an endorsement, adoption, certification, or verification of its contents by Olonzo Inspections.
25.2 Additional Inspection Report – Wood-Destroying Insect (WDI)
Completed
A separate Wood-Destroying Insect (WDI) inspection was completed by a licensed pest inspection company. Please review that report along with this home inspection report, as it contains the inspection findings, recommendations, and any corrective actions identified during the evaluation.
25.3 Additional Inspection Report - Radon
Pending
25.7 Additional Inspection Report - Sewer Scope
Completed
SEWER SCOPE VIDEO
Sewer Scope Inspection
A separate sewer scope inspection was completed by a qualified sewer inspection contractor. Please review that report along with this home inspection report, as it contains the inspection findings, video documentation, recommendations, and any corrective actions identified during the evaluation.
Main Sewer Line – Cracking Present
Cracking was identified within portions of the main sewer / drain line during the sewer scope performed by the plumbing contractor. Cracked sewer piping can continue to deteriorate and may contribute to leakage, root or soil intrusion, restricted flow, blockage, or eventual failure of the affected section. Refer to the sewer scope report and contractor findings for the specific locations, extent, and condition of the piping.
Recommendations
Follow the recommendations provided by the sewer / drain contractor regarding further evaluation and repair of the cracked portions of the main line. Depending on the extent and location of the damage, repairs may involve localized replacement, lining where appropriate, or replacement of affected piping. Obtain the contractor's recommended scope of work and associated repair costs before the end of the inspection contingency period.
Findings Summary
Findings Summary
Findings Summary
This section summarizes the items identified during the inspection, organized by the report chapter in which they appear, describing what was found without repeating each item's full narrative or corrective recommendation — location references are drawn from tags applied to each finding where available. It's meant as a quick-reference convenience only and isn't a substitute for reading the complete report, which contains the full detail, recommendations, photos, and context for each item.
Ch. 2 Appliance Disconnects and Utility Shutoffs
- Missing Furnace Shutoff – A dedicated electrical disconnect for the furnace was not located, which can complicate safe servicing and emergency shutdown of the equipment.
Ch. 3 Grounds
- Driveway – Surface Deterioration (Driveway) – The driveway surface shows cracking, wear, and localized breakdown across multiple areas; freeze/thaw cycling and de-icing exposure typically accelerate this deterioration.
- Large Cracks in Flatwork (Exterior - Rear, Patio) – Cracks in the flatwork are wide enough to be more than cosmetic and are typically related to settlement, soil movement, or frost heave beneath the slab.
- Tripping Hazard Present (Exterior - Front, Driveway, Walkways) – Uneven surfaces and abrupt height changes are present in the flatwork, creating a trip hazard.
- Large Lip Between Driveway and Garage Slab (Garage - Exterior) – A noticeable height difference is present where the driveway meets the garage floor, creating a trip hazard and a place for water to collect.
- Vegetation Too Close To Structure (Exterior - Front, Exterior - Rear, Exterior - Left Side, Exterior - Right Side) – Shrubs, vines, or other plantings are in direct contact with exterior wall surfaces at multiple locations, which can hold moisture against materials and conceal rot or pest activity.
- Tree Overhanging Roof – Tree branches extend over the roof, with portions low enough to contact roofing during wind or snow loading, and can drop debris into the gutters.
- Soil Grade Too High (Garage - Exterior) – Soil and landscaping material are built up against the exterior wall with little to no clearance below the siding, keeping the lower wall damp and increasing the potential for rot and insect entry.
- Vegetation Too Close to Electric Service Drop – Tree branches or shrubbery are growing close to the overhead electric service drop, which can wear insulation and cause arcing or service interruption.
- Downspout Discharge – Disconnected From Storm Drain (Exterior - Front, Exterior - Rear) – A downspout has come disconnected from the underground storm drain and is discharging water at the foundation.
- Flat Yard Grading Against Foundation – The ground at the foundation is essentially flat rather than sloping away from the house, allowing rainwater to linger against the foundation.
- Window Well Full of Organic Debris (Exterior - Left Side) – A window well is filled with leaves and soil, which can clog drainage and hold moisture against the basement window and foundation.
- Missing Window Well Covers (Exterior - Left Side) – Covers are not installed on one or more window wells, allowing leaves, snow, and rainwater to collect in the wells.
Ch. 4 Exterior Siding, Doors and Windows
- Warped Siding (Exterior - Front, Garage - Exterior, Siding / Cladding) – Portions of the exterior siding are warped or bowed, which may open gaps that allow moisture intrusion behind the cladding.
- Loose Exterior Siding (Exterior - Left Side, Siding / Cladding) – Portions of the exterior siding are loose or not securely fastened, which can allow wind-driven rain and pests behind the cladding.
- Inadequate Exterior Caulking (Siding / Cladding) – Exterior caulking is missing, cracked, or deteriorated at joints and material transitions, which can allow water intrusion behind exterior coverings.
- Blistering/Peeling Paint (Garage - Exterior, Exterior - Left Side, Siding / Cladding, Trim / Fascia / Soffits/Eaves) – Blistering and peeling paint are present on portions of the exterior, exposing underlying materials to increased moisture.
- Damaged Exterior Trim (Garage - Exterior, Exterior - Left Side, Trim / Fascia / Soffits/Eaves) – Sections of exterior trim are damaged, split, or loose, which can allow moisture intrusion behind exterior finishes.
- Gaps or Spaces in Exterior Materials (Garage - Exterior, Siding / Cladding) – Gaps are present at sections of siding and trim, which can allow moisture intrusion, air leakage, and pest entry.
- Garage Awning / Overhang – General Conditions – The awning attached to the garage shows conditions such as aging materials, questionable connections, or limited flashing that warrant attention.
- Damaged Finish at Exterior Door (Garage - Exterior, Exterior - Front) – Exterior door finishes are worn or deteriorating, leaving door materials more vulnerable to moisture and weathering.
Ch. 5 Decks, Porches, Balconies and Exterior Stairs
- Concrete Porch – Minor Cracking Present (Exterior - Left Side, Porch) – Minor cracking is present at the concrete porch; openings can allow moisture penetration that may worsen with freeze/thaw cycles.
- Non-Uniform Stair Riser Heights (Exterior - Front, Exterior - Left Side, Porch) – The stair risers are not uniform in height. Inconsistent stair geometry can increase the likelihood of trips and falls, particularly during descent.
Ch. 6 Roof, Chimney and Gutters
- Granule Loss (Roof - General) – Granule loss is present on portions of the asphalt shingle roof covering, leaving shingles more susceptible to accelerated wear.
- Damaged Plumbing Vent Stack (Roof - General, Flashing / Penetrations) – The plumbing vent stack at the roof is damaged, which can affect plumbing venting and increase the risk of water intrusion at the penetration.
- Gutter Debris / Cleaning Needed (Roof - General, Gutters & Downspouts) – Organic debris is present in portions of the gutters, which can restrict runoff and cause overflow.
- Loose/Disconnected Gutter Spikes (Roof - General, Roof - Front Slope, Gutters & Downspouts) – Several gutter spikes are loose or disconnected, allowing portions of the gutter to pull away from the fascia.
- Concrete Chimney Cap – Inadequate Overhang (Chimney - Exterior) – The concrete chimney cap does not extend sufficiently beyond the masonry, providing limited protection from water runoff.
- Brick Chimney – Missing Mortar (Chimney - Exterior) – Mortar is missing or deteriorated at portions of the brick chimney, which can allow water intrusion and accelerate masonry deterioration.
Ch. 8 Fuel Storage and Distribution
- Vegetation Too Close to Gas Meter – Vegetation is growing too close to the gas meter and piping, restricting access for servicing and emergency shutoff.
- Gas Piping – Missing Protective Coating – Portions of the exterior gas piping are missing protective rust-inhibiting paint, leaving the metal more vulnerable to corrosion.
Ch. 9 Electric Service
- Weather Head – Missing Cap – The electrical service mast is missing its weatherhead cap, which may allow rainwater to enter the mast and reach the service conductors.
- Missing Drip Loop at Electrical Service – The service conductors do not appear to include a proper drip loop, which may allow water to follow the conductors into the service entry.
- Multiple Electrical Recommendations – Multiple concerns are present within the electrical system that may affect safety, reliability, or proper operation.
- Gas Piping Bonding Not Verified – No visible bonding connection was identified for the metal gas piping system.
Ch. 10 Electric Distribution and Finish Wiring
- Abandoned Electrical Wiring (Exterior - Rear) – Abandoned or apparently unused wiring is present, and whether it remains energized could not be determined.
- Cloth-Covered Electrical Wiring Present (Garage Interior, Attic, Basement) – Older cloth-covered wiring is present; the rubber insulation beneath the cloth commonly becomes brittle with age and is more susceptible to damage when disturbed.
- Open Electrical Junction Box (Garage Interior) – An electrical junction box is missing its cover, leaving wiring and connections exposed.
- Unprotected Electrical Wiring (Electrical - Meter) – Wiring near the electric meter is not adequately protected from physical damage.
- GFCI – Inconsistent With Modern Standards (Kitchen, Garage - Exterior, Primary Bathroom) – GFCI protection is missing or incomplete in areas where modern safety standards call for it.
- Exterior Receptacle Not Weather-Rated – An exterior receptacle does not appear to be rated for weather-resistant use, which can lead to corrosion and increased shock risk.
- Open Grounds Present (Primary Bathroom, Kitchen, Dining Room, Living Room, Primary Bedroom, Bedroom 2, Bedroom 3) – Receptacles in multiple rooms tested with an open ground, which reduces fault protection and may increase shock risk.
- Older Two-Wire (Ungrounded) Electrical Outlets (Additional Living Areas, Primary Bedroom, Bedroom 3) – Older two-wire outlets without an equipment grounding conductor are present, providing reduced protection against shock.
- Damaged Electrical Cover Plate (Primary Bedroom) – An outlet cover plate is damaged, which can allow unintended contact with energized components.
- Missing Light Fixture Cover (Exterior - Left Side, Basement) – Light fixtures are missing their protective covers, leaving bulbs and components exposed.
- Inoperative Light Fixture (Garage Interior, Primary Bathroom) – Light fixtures did not operate at the time of inspection.
- Inadequate Carbon Monoxide Alarm Coverage (First Floor, Basement) – Carbon monoxide alarm coverage does not appear consistent with modern safety recommendations for sleeping areas and each level of the home.
- Smoke Alarms – Insufficient Coverage (Primary Bedroom, Bedroom 2, Bedroom 3) – Smoke alarms are not installed in all locations recommended by modern residential safety practices, including sleeping rooms.
Ch. 11 Heating, Cooling, Fireplaces and Ventilation
- Air Conditioning System – Servicing / Maintenance Recommended – The air conditioning system would benefit from professional servicing to support reliable cooling performance.
- High-Efficiency Furnace PVC Vent Termination – The furnace's exterior PVC vent termination is vulnerable to debris, snow, vegetation, or pest obstruction, which may interfere with venting.
- High-Efficiency Furnace Operating as Single-Pipe System – The high-efficiency furnace draws combustion air from inside the home rather than from a dedicated exterior intake.
- Duct Tape Used on HVAC Ductwork – Standard cloth-backed duct tape is present on portions of the ductwork; this material commonly deteriorates and can contribute to air leakage and reduced efficiency.
- Creosote Accumulation in Wood-Burning Appliance Venting System – Creosote has accumulated within the wood-burning appliance venting system, which can increase the potential for chimney fires.
- Inadequate Fireplace Hearth Extension – The hearth extension in front of the wood-burning fireplace appears smaller than commonly recommended clearances.
Ch. 12 Plumbing
- Functional Water Flow – Below Typical Performance – Water flow at one or more fixtures is lower than typically expected for normal residential use.
- Saddle (Piercing) Valve Present – A saddle (piercing) valve is installed on the supply piping; these fittings are more prone to restriction, leakage, and failure than modern connections.
- Plumbing Drain – Missing P-Trap (Basement Bathroom) – A P-trap is not present at a fixture drain, which can allow sewer gases into the living space.
- Sink Draining Into Floor Drain (Basement Bathroom) – The basement sink discharges directly into the floor drain rather than connecting to the sanitary drainage system.
- Leak at Waste Pipe (Basement Bathroom) – Leakage is present at the waste piping, which can contribute to moisture damage and concealed deterioration.
- Water Heater – TPR Relief Valve Actively Leaking – The water heater's temperature and pressure relief valve is actively leaking; this critical safety device may indicate a faulty valve or excessive pressure or temperature.
- Signs of Backdrafting at Water Heater – Evidence consistent with possible backdrafting is present at the water heater vent connection, which may allow combustion byproducts to enter the interior.
- Older Water Heater – Monitor and Service – The water heater appears to be older; while operating, units of this age are more susceptible to leakage and unexpected failure.
- Missing Anti-Siphon Protection – Exterior hose bibs are not equipped with anti-siphon protection, which helps prevent contaminated water from being drawn into the potable supply.
Ch. 14 Interior Living Area(s) and Bedrooms
- Minor Interior Wall/Ceiling Cracking (Kitchen, Hallways, Bedroom 2) – Minor cracking is present at interior wall and/or ceiling finishes, consistent with normal shrinkage and seasonal movement.
- Low Ceiling Height – Reduced Headroom Clearance (Second Floor, Basement) – Ceiling height in portions of the home is lower than modern residential standards, creating a head-strike hazard along walking paths.
- Interior Door Not Latching (Living Room, Primary Bedroom) – Interior doors do not latch consistently and do not remain securely closed.
- Cracked Window Pane (Garage Interior) – A window pane is cracked, weakening the window and reducing its energy efficiency.
- Failed Window Seal / Condensation Between Panes (Additional Living Areas) – Condensation is present between the panes of a window, indicating a failed insulated glass seal.
- Windows – Inoperable or Improper Locking (Additional Living Areas) – One or more windows do not lock properly, reducing security and weather sealing.
- Missing Window Locks (Primary Bathroom) – One or more windows are missing locking hardware.
- Window Will Not Stay Open (Living Room, Bedroom 2) – One or more windows will not stay open on their own, which can cause injury if the sash closes unexpectedly.
- Stairs – Multiple Observations or Improvements (First Floor, Basement, Stairs-Interior) – Several aspects of the stair assembly do not appear fully consistent with modern stair safety and construction practices.
Ch. 15 Kitchen
- Missing Range Anti-Tip Device – The range is missing an anti-tip bracket, allowing the appliance to tip forward if weight is placed on the open oven door.
- Microwave Is Close to Cooktop – The over-range microwave has limited clearance above the cooktop, which can affect usability and heat exposure during cooking.
Ch. 16 Laundry Facilities
- Dryer Vent – Missing Backdraft Damper – The exterior dryer vent is missing its backdraft damper, allowing outside air, moisture, and pests into the duct.
- Dirty Dryer Exhaust Vent – Excessive lint has accumulated in the dryer vent, restricting airflow and increasing fire risk.
- Improper Material at Dryer Vent Connection – Non-approved tape is present at the dryer vent connection and can loosen over time, allowing lint and moisture to escape.
Ch. 17 Bathroom Finishes
- Toilet – Loose (Basement Bathroom) – The toilet is loose at the floor connection, which may compromise the wax seal and allow concealed leakage beneath the fixture.
- Toilet Not Caulked to Floor (Basement Bathroom) – The toilet is not sealed to the floor at the base, allowing moisture and debris to collect beneath the fixture.
- Toilet – Running (Basement Bathroom) – The toilet continued to run after flushing, indicating tank components are not sealing properly.
- Inoperable Shower Diverter (Primary Bathroom) – The shower diverter does not properly direct water between the tub spout and showerhead.
- Bathroom Caulking Deficiencies – Multiple Locations (Primary Bathroom, Basement Bathroom) – Caulking is missing, cracked, or deteriorated at bathroom fixtures and finish surfaces, which can allow water past finished surfaces.
- Incomplete or Disconnected Bathtub Stopper (Primary Bathroom) – The bathtub stopper is incomplete or not functioning, preventing the tub from holding water.
- Tub / Shower Fixture – Active Leak (Primary Bathroom) – An active leak was present at the tub/shower fixture, which can contribute to moisture intrusion and concealed damage.
Ch. 18 Attic, Roof Structure and Ventilation
- Attic Access Hatch – Insulation / Weather Stripping Needed – The attic access hatch is not insulated and/or weather-stripped, allowing air movement between the attic and living space.
- Damaged Roof Sheathing – Roof sheathing is damaged at a visible location, commonly associated with prolonged moisture exposure; the full extent could not be determined.
- Attic Insulation – Improvement Recommended – The attic insulation level appears lower than modern energy-efficiency recommendations for this climate region.
- Attic / Roof Cavity Ventilation – Non-Standard – The attic ventilation configuration appears non-standard and may not provide effective airflow.
Ch. 19 Foundation, Structure and Basement
- Foundation – Previous Repairs / Condition Needing Further Review – Substantial cracking and extensive previous repair work are present at portions of the foundation walls; the reason for the repairs and their long-term performance could not be determined.
- Floor Joists Cut Without Proper Framing Support – One or more floor joists have been cut or altered without proper headers or framing to transfer structural loads.
- Concrete Slab – Large Crack (Garage Interior, Basement) – A larger-than-typical crack is present in the concrete slab, suggesting movement or stress that may continue over time.
Ch. 25 Additional Reports
- Main Sewer Line – Cracking Present – Cracking was identified within portions of the main sewer/drain line during the sewer scope performed by the plumbing contractor; cracked piping can continue to deteriorate and may lead to leakage, root intrusion, blockage, or failure of the affected section.
Receipt -- 📃 The Complete Inspection Report
1908 Heritage Avenue Columbus, OH 43206
| Home Inspection | $425.00 |
| Radon (2-3 business days) | $175.00 |
| Termite | $85.00 |
| Sewer Scope | $275.00 |
| $960.00 | |
| PAID |
Olonzo Inspections
237 Olde Mound ln
Pickerington, Ohio 43147
(614) 296-3721






.jpg)
.jpg)
.jpg)





.png)








 (1) (1).jpg)




.png)
.jpg)





.jpg)








