HOME INSPECTION SCOPE, LIMITATIONS, AND IMPORTANT INFORMATION
This report is best viewed on a computer or tablet for the clearest formatting and photo detail.
PURPOSE OF THE INSPECTION
This home inspection is a visual, non-invasive evaluation of the home's readily accessible systems and components at the time of the inspection. The purpose is to provide a practical understanding of the property's condition based on visible observations. While a home inspection helps reduce risk, it cannot eliminate it, and should be used to help prioritize repairs, maintenance, and future improvements.
SNAPSHOT IN TIME
This inspection reflects the condition of the property only at the time of the inspection. Conditions may change due to weather, occupancy, maintenance, repairs, or normal aging. Hidden, intermittent, seasonal, or concealed conditions may exist that were not visible during this visual inspection.
SCOPE OF INSPECTION
The inspection includes a general review of the home's major, readily accessible components, which may include:
• Roofing
• Exterior
• Structure
• Attic
• Plumbing
• Electrical
• Heating and cooling systems
• Interior
• Insulation and ventilation
• Built-in appliances
• Garage, basement, and crawlspace (where applicable)
The inspection is visual and non-invasive. It is not technically exhaustive and does not identify every cosmetic, minor, concealed, or future condition.GENERAL LIMITATIONS
Any areas identified as limited, inaccessible, obstructed, concealed, unsafe, or otherwise unavailable for inspection may contain conditions that could not be determined at the time of the inspection.
This inspection is:
Visual and non-destructive
Limited to readily accessible areas
Performed without dismantling systems or moving personal belongings
The inspection does not include:
Destructive testing or disassembly
Engineering analysis
Code compliance certification
Permit or municipal research
Identification of all concealed or latent defects
Areas that are concealed, obstructed, unsafe, inaccessible, or otherwise unavailable for inspection are outside the scope of this inspection.
ACCESS AND OCCUPANCY
Furnishings, storage, finishes, insulation, and personal belongings may limit visibility. I make every reasonable effort to inspect accessible areas without disturbing personal property; however, concealed conditions may remain hidden.
UTILITIES, WEATHER, AND OPERATING CONDITIONS
Some systems may not be operated when doing so could cause damage, create a safety concern, violate manufacturer recommendations, or when weather, seasonal conditions, utilities, or access restrictions prevent normal operation.
MODERN STANDARDS
This is not a code compliance inspection. However, references to modern standards, manufacturer specifications, common installation practices, and current safety recommendations may be included to help explain why a condition may be considered a concern. Recommendations may occasionally reference modern safety practices, manufacturer guidance, or current installation standards. This does not necessarily mean a component was improperly installed at the time of construction, only that improvements may be beneficial by today's expectations. Especially in older homes, it is common to find conditions that were acceptable at the time of installation but are no longer considered best practice.
MOISTURE AND HIDDEN CONDITIONS
Moisture intrusion can be intermittent or concealed. Hidden leaks, moisture damage, mold-like substances, or related deterioration may exist without visible evidence at the time of inspection. Moisture meters and thermal imaging, when used, are screening tools only and do not determine the full extent, source, or duration of a condition.
SPECIALISTS AND REPAIRS
When concerns are identified, repairs, maintenance, upgrades, monitoring, or further review may be recommended. References to contractors, specialists, trades, or qualified professionals within this report are intended as general guidance only and should not be interpreted as a definitive determination of who must perform the work. The appropriate professional may vary depending on the full scope of repairs ultimately required. Contractors frequently uncover additional deficiencies, damage, deterioration, or repair needs once materials are removed or systems are further investigated. Discovery of additional conditions during repair work should be considered normal and does not necessarily indicate those conditions were visible or readily accessible at the time of the inspection.
Contractors, specialists, engineers, and other qualified professionals may provide:
Repair recommendations
Scope of work
Cost estimates
Identification of concealed conditions
Design, engineering, or permitting requirements
SPECIALTY INSPECTIONS NOT INCLUDED
Unless specifically contracted as a separate service, this inspection does not include:
Mold or indoor air quality testing
Asbestos identification
Lead paint identification
Wood-destroying insect inspections
Sewer scope inspections
Environmental hazards
Geological or soil analysis
Well water quality testing
Underground utilities or piping
Solar energy systems
Security, communication, audio, or low-voltage systems
Determination of property boundaries, easements, or survey conditions
Thermal Imaging
An infrared camera was used selectively to examine specific areas of concern or to help validate suspected issues. Its use should not be interpreted as a comprehensive thermal survey of the entire structure. Deployment of the infrared camera was at my discretion to provide additional insight, and its application goes beyond the standard scope of a home inspection.
Temperature readings shown on thermal images are provided as a courtesy and should not be solely relied upon. They are intended as qualitative indicators rather than precise measurements, and actual temperatures may vary by +/- 2% or more. Some readings reflect surface temperatures only, and obtaining air or internal temperature measurements is beyond the scope of this inspection.
ONGOING MAINTENANCE
All homes require ongoing maintenance, including routine servicing, cleaning, sealing, adjustments, repairs, and monitoring throughout their service life.
How to Read this Report
- Note:Refers to aside information and /or any comments elaborating on descriptions of systems in the home or limitations to the home inspection. This section may include notes, recommendations, improvement suggestions, or statements based on modern standards.
- Moderate Repair And Maintenance Items:
Items identified with safety hazards or functional/installation deficiencies may have been operational at the time of inspection, but their functionality could be compromised. These defects often lead to further issues. Repairs or replacements are recommended for optimal performance and to prevent future problems before the end of your contingency period. Such items typically require attention from a qualified contractor or handyman and are not suitable for routine maintenance or DIY repairs. - Items Recommended For Improvement Or Maintenance:
This category encompasses items or components requiring minor repairs to enhance functionality, as well as those needing regular or basic maintenance. It also includes observations and recommendations for upgrades to specific items, areas, or components. - Conditions Warranting Safety Improvements:
The item, system, area, or component poses a safety concern that should be addressed promptly by a qualified professional. Identifying potential hazards is a key aspect of home inspection, as the inspector evaluates the property’s safety and highlights any risks affecting occupant well-being.
📃 The Complete Inspection Report
Ch. 3 Grounds
3.1
3.2 Grounds Overview Photos
3.3 Driveways/Walkways/Patios
3.4 Grounds, Trees and Vegetation
3.5 Drainage and Site
3.6 Window and Stairwells
3.7 Retaining Walls
3.8 Fences
3.9 Outbuildings, Carports, Storage Sheds, Barns
Ch. 4 Exterior Siding, Doors and Windows
4.1
4.2 Exterior Overview Photos
4.3 Siding and Trim
4.4 Eaves, Overhangs, Soffits and Fascia
4.5 Exterior Doors
4.6 Exterior Window Frames
4.7 Exterior Vent and Exhaust Terminations
Ch. 5 Decks, Porches, Balconies and Exterior Stairs
5.1 Wood Decks Porches and Balconies
5.2 Concrete Decks, Stoops, Patios, Landings and Porches
5.3 Exterior Stairs
5.4 Water-Resistant Decks and Balconies
5.5 Metal Decks and Balconies
Ch. 6 Roof, Chimney and Gutters
6.1
6.2 Roof Overview Photos
6.3 Exterior Elevations and Roof Pitch
6.4 Roof Materials
6.5 Flashings, Valleys and Penetrations
6.6 Gutters and Downspouts
6.7 Chimneys
6.8 Skylights
Ch. 7 Garage
7.1 Garage Overview Photos
7.2 Garage General
7.3 Garage Fire Separation
7.4 Garage Doors and Automatic Openers
Ch. 8 Fuel Storage and Distribution
8.1 General Comments
8.2 Gas Meter
8.3 Gas, Propane and Oil Piping
8.4 Oil Storage
8.5 Propane Storage
Ch. 9 Electric Service
9.1
9.2 Electrical System Safety Overview
9.3 Electric Service Permits Found
9.4 Electric Service Voltage Tested
9.5 Electric Service
9.6 Electric Service Equipment
9.7 Sub Panel
9.9 Electrical Grounding System
9.10 Electrical Bonding System
Ch. 10 Electric Distribution and Finish Wiring
10.1 Branch Wiring
10.2 Receptacles and Fixtures
10.3 Ceiling Fans and Lighting
10.4 Smoke and Carbon Monoxide Alarm Systems
Ch. 11 Heating, Cooling, Fireplaces and Ventilation
11.1
11.2 Thermostat
11.3 Cooling Systems
11.4 Heating System
11.5 Air Filters
11.6 Vents and Flues
11. 7 Heating and Cooling Distribution Systems
11. 8 Mechanical Ventilation Systems
11.9 Gas Fireplaces
11.10 Wood Burning/Solid Fuel Fireplaces
11. 11 Additional Heat Sources
Ch. 12 Plumbing
12.1
12.2 Water Meter
12.3 Water Service Supply
12.4 Distribution Pipe
12.5 Waste Pipe and Discharge
12.6 Water Heater
12.7 Water Temperature
12.9 Exterior Hose Bibs
Ch. 13 Additional Plumbing
13.1 Sump Pumps and Drains
13.2 Radon Equipment
13.3 Water Filters
13.4.1 Sewage Ejector Pumps
13.4.2 Central Vacuum
13.4.3 Fire Suppression
13.4.4 Irrigation
13.4.5 Spa
13.4.6 Water Features
13.4.8 Sauna
13.4.9 Swimming Pools
Ch. 14 Interior Living Area(s) and Bedrooms
14.1
14.2 Interior Overview Photos
14.3 Walls, Ceilings and Trim
14.4 Floors and Floor Materials
14.5 Interior Doors and Doorstops
14.6 Windows
14.7 Additional Interior Cabinets and Countertops
14.8 Wall Insulation and Air Bypass
14.9 Interior Stairs
14.10 Indoor Air Quality
Ch. 15 Kitchen
15.1
15.2 General Kitchen Pictures
15.3 Sinks and Faucets
15.4 Cabinets and Countertops
15.5 Ranges, Ovens and Cooktops
15.6 Dishwasher
15.7 Refrigerators
15.8 Disposers
15.9 Microwave
15.10 Kitchen Ventilation Method
15.11 General Appliances
Ch. 16 Laundry Facilities
16.1
16.2 Laundry Overview Photos
16.3 Washer
16.4 Dryer
16. 5 Laundry Ventilation
Ch. 17 Bathroom Finishes
17.1
17.2 Bathroom Overview Photos
17.3 Sinks and Cabinets
17.4 Toilets
17.5 Bathtub / Shower / Bathtub Walls and Enclosures
17.6 Bathroom Ventilation
17.8 General Bathroom Finishes Condition
Ch. 18 Attic, Roof Structure and Ventilation
18.1
18.2 Attic Overview Photos
18.3 Attic Access
18.4 Roof Framing and Sheathing
18.5 Fire Separation
18.6 Attic Insulation
18.7 Attic and Roof Cavity Ventilation
Ch. 19 Foundation, Structure and Basement
19.1
19.2 Foundation
19.3 Floor, Wall and Ceiling Framing
19.4 Basement Overview Photos
19.5 Slabs and Concrete Floors
19.6 Basement Moisture
Ch. 20 Crawl Space
20.1 General Crawl Space
20.2 Crawl Space Access
20.3 Vapor Barrier
20.4 Crawl Space Ventilation
20.5 Posts and Footings
20.6 Insulation
20.7 Moisture Conditions
Ch.1 General Comments
1.1 Building Characteristics, Conditions and Limitations
Info and LMT's. The approximate square footage listed here is listed as a courtesy and is based off of public records and disclosure. An evaluation of square footage of the buildings and property lines is beyond the scope of this inspection.
Info and LMT's. Vacant homes present unique inspection limitations because many systems have not been subjected to regular use prior to inspection. While systems may function during testing, future performance cannot be predicted. Hidden leaks, drainage issues, fixture failures, and other conditions may only become apparent after normal occupancy resumes.
For the sake of this inspection, the front of the structure will be considered as the portion pictured in the above cover photo. References to the left or right of the structure should be construed as standing in the front yard, viewing the front of the structure.
New Construction – Important Information
New construction has little or no performance history. Conditions related to settlement, material movement, moisture, equipment operation, and normal use may not become apparent until after the home has been occupied through changing seasons. Minor adjustments and repairs are common during the initial years of ownership.
Keep copies of applicable building documents, warranties, equipment information, and available construction plans for future reference. Builder warranty periods and requirements should be reviewed, and concerns that develop during occupancy should be documented and reported before applicable warranties expire.
For condominium, townhouse, or HOA-managed properties, maintenance and repair responsibilities can vary between the individual owner and the association. Review the governing documents and available association records to understand these responsibilities and identify any known conditions affecting shared or common components.
Consider retaining a reasonable quantity of matching specialty materials, such as flooring, tile, trim, siding, or roofing materials, where available, as matching products may become difficult to obtain over time.
Permit Note
In accordance with the Ohio Home Inspector Standards of Practice, obtaining or researching building permits is outside the scope of this home inspection. Clients are encouraged to verify permits, inspections, warranties, and other documentation for any additions, alterations, repairs, or improvements made to the property.
References to permits elsewhere in this report reflect only information that was voluntarily provided or readily available during the inspection and should not be considered a comprehensive permit search.
As this is a new construction building, the building plans, permits, drainage plans, construction records, a list of sub-contractors and warranty information is available. I recommend trying to obtain and keep this information for your records and for future re-sale.
Ch. 2 Appliance Disconnects and Utility Shutoffs
2.1 Shutoffs and Disconnects Noted
Picture Showing Main Electric Panel Disconnect at the Electric Meter and at the Main Panel
The service disconnect or main OCPD (over current protection device) was inspected looking for any deficiencies and reporting on its location. This disconnect can be a breaker, fuse block, or kill switch. This is the means of shutting off all electricity entering the home
Ch. 3 Grounds
3.1
Per the Standards of Practice, the home inspector shall observe Exterior electrical receptacles and the presence of GFCI protection (GFCI protection was not required prior to 1975, but upgrading is recommended for safety). Decks, balconies, stoops, steps, areaways, porches, and applicable railings that are directly attached to the structure. Vegetation, grading, and drainage of grounds, driveways, patios, walkways, and retaining walls will be inspected with respect to their effect on the condition of the structure.
The home inspector is not required to observe: Fences and gates, Geological conditions, Soil conditions, Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities), Detached buildings or structures, or the Presence or condition of buried fuel or waste storage tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstruct access or visibility.
3.2 Grounds Overview Photos
3.3 Driveways/Walkways/Patios
Driveway: Concrete
Walkways: Concrete
Patios: Not Present
All readily accessible driveways, walkways, and flatwork areas were visually inspected through a representative sample of accessible surfaces for cracking, drainage concerns, settlement, trip hazards, slope, deterioration, surface wear, and vegetation-related conditions. No significant deficiencies were noted unless otherwise described within this section.
3.4 Grounds, Trees and Vegetation
Trees/Vegetation too near building: Well Pruned-Monitor
All readily accessible grounds, trees, vegetation, and site areas were visually inspected through a representative sample of accessible surfaces and conditions for grading concerns, drainage patterns, vegetation contact, erosion, settlement, moisture-related conditions, and general site performance. No significant deficiencies were noted unless otherwise described within this section.
New Construction – Incomplete Landscaping and Site Work
Landscaping and exterior site work appear incomplete at the time of inspection. Areas such as final grading, soil stabilization, vegetation, and drainage features may not yet be fully installed or finished. These elements play an important role in directing water away from the structure and supporting proper drainage. It is recommended to confirm with the builder or seller what work remains, the planned final grading design, and any associated warranties or responsibilities for completion.
3.5 Drainage and Site
Downspout Discharge Type: Below grade
Site Description: Moderate slope, New Construction Note
All readily accessible drainage and site conditions were visually inspected through a representative sample of accessible areas for grading, water management, drainage performance, erosion, settlement, runoff control, and moisture-related concerns. No significant deficiencies were noted unless otherwise described within this section.
The grounds in contact with the structure were inspected to determine that they were sloped to allow rainwater to drain away from the structure adequately. The soil is recommended to slope away from the foundation, with a 6-inch drop in elevation, in the first 10 feet away from the structure (5% grade). When the 5% grade cannot be achieved, swales or drains should be used as needed to properly divert and/or manage rainwater runoff. Any flat or low areas around the structure should be backfilled and sloped away from the foundation to prevent potential moisture infiltration into areas below grade (as applicable). No significant grading deficiencies were present at the time of inspection unless otherwise described within this section.
Info and LMT's. Info & LMT's – Site Grading, Drainage, and Underground Drainage Systems
The home inspection is limited to the visible conditions present at the time of the inspection and does not include the examination of underground or concealed drainage systems, including subterranean pipes, footing drains, foundation drains, or other buried components designed to manage surface or groundwater. These systems are outside the scope of a visual home inspection and cannot be evaluated without specialized testing or excavation.
The effectiveness of site grading, lot drainage, and moisture management can vary significantly with weather conditions, seasonal changes, soil moisture levels, and property maintenance. Conditions such as heavy rainfall, prolonged wet periods, frozen ground, clogged or leaking gutters and downspouts, or changes to the landscape may reveal drainage or moisture concerns that were not visible at the time of the inspection.
The assessment of grading and drainage is limited to visible evidence of current or previous performance. Because moisture intrusion can be intermittent, no determination can be made regarding future water infiltration through foundation walls, crawl spaces, basements, or beneath floor slabs. Clients are encouraged to review the Seller's Disclosure and inquire about any history of water intrusion, drainage concerns, or previous corrective work. If drainage performance or concealed underground systems are a concern, further assessment by an appropriate drainage, waterproofing, or excavation specialist is recommended.
Drainage & Roof Runoff Note
Roof runoff is directed away from the home through gutters, downspouts, and any installed extensions. Proper maintenance of these components, along with maintaining positive grading around the structure, helps reduce the potential for water to collect near the foundation and supports long-term moisture management.
As a general guideline, the soil surrounding the home should slope away from the foundation approximately 6 inches within the first 10 feet (about a 5% grade), where practical. Routine monitoring and maintenance of gutters, downspouts, extensions, grading, and drainage pathways can help identify clogs, blockages, settlement, or other conditions that may reduce drainage performance and contribute to moisture-related concerns over time.
3.6 Window and Stairwells
Window Well or Basement Wells: Present
All readily accessible window wells were visually inspected through a representative sample of accessible areas for drainage, size and clearance, general condition, debris accumulation, covers or grates, safety features, sealing, and accessibility. No reportable deficiencies were visibly present at the time of inspection unless otherwise noted within this report.
Window Well Drainage
The window well lacks a visible drainage system or adequate water-management provisions. Conditions like this can reduce the ability of the well to properly disperse water and may contribute to moisture intrusion or deterioration near basement openings.
Recommendations:
If the home is newer construction or may still fall within a builder warranty period, consultation with the builder is recommended. Improvements or corrective work may include addressing drainage, grading, or installation-related conditions contributing to water accumulation around the window well area.
Key Points:
- Drainage improvements may help support long-term foundation and basement performance
Missing Window Well Covers
One or more window wells lack protective covers, increasing the likelihood of debris buildup and water accumulation. Conditions like this can reduce drainage effectiveness and may contribute to moisture intrusion or deterioration near basement window openings.
Recommendations:
Consultation with the builder is recommended. Improvements may include installation of appropriate window well covers and addressing related drainage or grading conditions contributing to moisture accumulation around basement openings.
3.7 Retaining Walls
Retaining Wall Materials if Applicable: Not Present
3.8 Fences
Fencing Present: Not Present
3.9 Outbuildings, Carports, Storage Sheds, Barns
Outbuilding Style if Applicable: Not Present
Ch. 4 Exterior Siding, Doors and Windows
4.1
Per the Standards of Practice, the home inspector shall observe from ground level: - Wall cladding, flashings, and trim; entryway doors and a representative number of windows; eaves, soffits, and fascias. The home inspector shall: Describe wall cladding materials, Operate all entryway doors and a representative number of windows, and probe exterior wood components where deterioration or damage is suspected.
The home inspector is not required to observe: Storm windows, storm doors, screening/screens, shutters, awnings, and similar seasonal accessories; the Presence of safety glazing in doors and windows; Detached buildings or structures; or the Presence or condition of buried fuel storage tanks, water tanks, or septic tanks. The home inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstruct access or visibility.
4.2 Exterior Overview Photos
General Elevations. The photos in this section provide representative views of the home’s exterior conditions as visible at the time of inspection.
Info and LMT's. This section provides representative views of the home’s exterior elevations as seen from the ground at the time of inspection. These photos are intended to document overall exterior conditions, including siding, trim, eaves, soffits, fascia, windows, doors, and visible exterior penetrations. Conditions not visible due to height, angle, finishes, weather, or obstructions may not be fully captured.
A home inspection entails a visual inspection of the accessible exterior components of the property that are readily accessible able and available. It does not encompass a thorough evaluation of concealed elements, nor does it consider weather-related influences, concealed damages, or inaccessible areas.
4.3 Siding and Trim
Trim Material: Wood
Siding Material: Vinyl, Fiber-cement
The wall cladding and trim were inspected in representative areas for significant damage, proper flashing details, and potential moisture intrusion points. No significant deficiencies were noted unless otherwise described within this section.
Info and LMT's. All visible sections of the flashings were examined for any notable deficiencies, including Z-flashings, drip caps, etc., where relevant. Given that flashings are often concealed by wall claddings, their functionality is assessed by checking for signs of moisture intrusion or damage in areas where they are expected to be present.
Manufacturers of fiber cement siding have done a poor job helping inspectors and consumers distinguish their products after installation; these products have few if any distinguishing characteristics. This report will site James Hardie manufacturers installation requirements for reference because they are the most common manufacturer of fiber cement siding and the various manufactures seem to share similar installation guidelines. Here is a link to the HZ-10 Best Practices Guide. However, reference of these guidelines in this report does not ensure that the fiber cement siding here is a James Hardie product.
Inconsistent Wall Cladding Flashing
Deficiencies were noted in the flashing installation at wall cladding transitions. Improper water-shedding details increase the likelihood of concealed moisture intrusion and may contribute to deterioration of adjacent building materials if left uncorrected.
Recommendations:
If the home is newer construction or may still be covered by a builder warranty, consultation with the builder is recommended. The builder may wish to verify that flashing and water-management details were installed in accordance with the original design and manufacturer requirements.
Key Points:
- Flashing helps direct water away from vulnerable wall transitions
- Long-term exposure may contribute to deterioration of sheathing, framing, and finish materials
Note:
Exposed Fasteners at Exterior Siding / Trim
Exposed or inadequately sealed fasteners were noted at portions of the exterior siding and/or trim. These locations can allow moisture intrusion and may contribute to staining, deterioration, or premature failure of surrounding materials.
Recommendations:
Have the builder correct exposed fasteners at the affected siding and trim in accordance with manufacturer installation requirements. Corrective work should include properly sealing or otherwise addressing affected fasteners and reviewing adjacent exterior finishes for similar installation conditions.
Inadequate Exterior Caulking
Deteriorated exterior sealant is present at multiple joints and transitions. Open gaps or failed caulking may allow increased moisture intrusion into surrounding assemblies, which can contribute to material deterioration and ongoing maintenance concerns if not addressed.
Recommendations:
I would consult with the builder. Improvements may include correcting incomplete or deteriorated exterior sealant installations, addressing affected joints and material transitions, and reviewing similar exterior areas where comparable installation or finishing conditions may exist to help support proper water management and long-term exterior performance consistent with modern construction practices.
Key Points:
- Exterior sealant requires periodic maintenance and replacement as part of normal upkeep
4.4 Eaves, Overhangs, Soffits and Fascia
Eaves Materials: Wood
The roof overhangs were inspected at representative visible portions for signs of water damage, deterioration, and other significant defects. No significant deficiencies were noted unless otherwise described within this section. Concealed damage may exist at structures where fascia and/or soffit coverings are clad with vinyl or aluminum materials, as these finishes can limit visibility of underlying components.
4.5 Exterior Doors
Exterior Door Styles: Solid core, Sliding glass
All exterior doors were inspected in representative visible areas for damage, operational deficiencies, flashing concerns, and other significant conditions. No significant deficiencies were noted unless otherwise described within this section.
Info and LMT's. Handlesets, including deadbolts and door handles, are not assessed for functionality with keys during the inspection. It is advisable to consider replacing or re-keying any deadbolts and handles due to uncertainty regarding who may have access to keys for the residence. Consequently, deadbolts and handles will be evaluated solely based on their alignment with the door, focusing on any issues preventing proper latching or locking.
4.6 Exterior Window Frames
Window Frames: Vinyl
The exterior components of the windows, including representative visible portions of trim, flashing, sealants, and related assemblies, were inspected for significant damage, improper flashing details, clearance concerns, and other visible deficiencies. No significant deficiencies were noted unless otherwise described within this section. Routine monitoring and maintenance of these areas is recommended to help reduce the likelihood of future moisture intrusion, deterioration, or pest-related concerns over time.
4.7 Exterior Vent and Exhaust Terminations
Vent Types: Present
The exterior penetrations were visually inspected in representative accessible areas for proper sealing, flashing, clearances, and signs of damage or deterioration. No significant deficiencies were noted unless otherwise described within this section. Ongoing monitoring and routine maintenance of exterior penetrations is recommended to help reduce the likelihood of moisture intrusion, air leakage, or pest entry over time.
Info and LMT’s – Concealed Vent Terminations and Connections. Vent terminations and duct connections located within sealed walls, ceilings, or other concealed areas could not be confirmed. The inspection is limited to visible and readily accessible components, and the continuity, routing, and final termination points of concealed ductwork are not fully verifiable. As a result, conditions such as disconnected ducts, improper terminations, or concealed damage may exist but are not detectable within the scope of a visual inspection. Inquire with the seller regarding any known issues, prior modifications, or available documentation related to the installation and routing of ventilation systems.
Ch. 5 Decks, Porches, Balconies and Exterior Stairs
5.1 Wood Decks Porches and Balconies
Wooden Decks, Porches or Balconies Present: Not Present
5.2 Concrete Decks, Stoops, Patios, Landings and Porches
Concrete Structure: Present
The concrete decks, stoops, landings, and porches were inspected in representative visible areas for significant damage, cracking, improper slope, flashing concerns, potential moisture entry points, and overall structural integrity. No significant deficiencies were noted unless otherwise described within this section.
5.3 Exterior Stairs
Exterior Stairs If Applicable: Present
The representative visible components of the exterior stair system were inspected by traversing the stairs, where possible, to evaluate their general condition, stability, handrails, guards (where applicable), and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Incomplete Builder-Grade Staircase
The staircase appears to be in an unfinished or builder-grade condition, with final finish materials and/or detailing not yet completed. This is primarily an informational observation at this stage of construction. Have the builder complete the staircase as intended prior to final occupancy or closing.
Non-Uniform Stair Riser Heights
Noticeable variations in stair riser height are present. Inconsistent stair geometry can interfere with normal walking rhythm and may create elevated trip and fall concerns, especially with regular use or reduced visibility conditions.
Recommendations:
Have the builder correct uneven stair riser heights to provide consistent stair geometry and reduce the potential for trips and falls. Corrective work should be completed in accordance with applicable requirements and accepted construction practices, with adjacent stairs reviewed for similar inconsistencies.
Key Points:
- Consistent stair geometry helps improve overall safety
5.4 Water-Resistant Decks and Balconies
Not Present
5.5 Metal Decks and Balconies
Not Present
Ch. 6 Roof, Chimney and Gutters
6.1
Per the Standards of Practice, the home inspector shall observe: The roof covering, roof drainage systems, visible flashings, skylights, chimneys, and roof penetrations and report signs of leaks or abnormal condensation on building components. The home inspector shall: Describe the type of roof covering materials and Report the method used to observe the roofing.
The home inspector is not required to: Walk on the roofing (although every safe attempt to do so will be taken), report on the age or remaining life of the roof covering, or move leaves, snow, or other items on the surface that may block visual accessibility, or observe attached accessories including but not limited to solar systems, antennae, satellite dishes, and lightning arrestors. No claims will be made as to the remaining roof material life expectancy, and no guarantee or warranty should be expected from comments or observations. The sellers or the occupants of a residence will generally have the most relevant knowledge of the roof and of its history. Therefore, I recommend that you consult with the sellers about the age of the roof covering and that you either include comprehensive roof coverage in your home insurance policy or obtain a roof certification from an established local roofing company.
6.2 Roof Overview Photos
Info and LMT's. The examination of the roof and its covering material is confined to the conditions observed on the day of inspection exclusively. The assessment includes inspecting the roof covering material, visible sections of the roof structure within the attic (if accessible), and interior ceilings to identify any signs of existing or previous leaks. It's important to note that leaks may become apparent in the future or during adverse weather conditions that were not evident during the inspection.
Any deficiencies documented in this report regarding the roof covering or signs of past or present leaks should be addressed promptly by a licensed roofing contractor. They should be evaluated and remedied as necessary to ensure the integrity of the roof and prevent potential damage.
6.4 Roof Materials
Method of Roof Inspection: Viewed with a drone, Viewed at top of ladder
Roof Covering Materials: Asphalt shingle, Architectural grade composition shingle
Roof Style: Mixed
Overlay Roof: No
Shingle Fastening Accessible For Inspection : No
Percentage of Roof that could be Safely Traversed: 0%
Approximate Age of Roof Covering: New
A representative sample of visible components of the roofing system were inspected for significant defects related to roofing materials, roof structure, flashing details, gutters, downspouts, ventilation components, roof penetrations, and debris conditions. No significant deficiencies were noted unless otherwise described within this section.
Info and LMT's. This home inspection does not provide a thorough examination of the roof's structural integrity or concealed components. The assessment is restricted to visually inspecting the accessible areas of the roof without utilizing invasive methods. Weather-related influences, concealed damages, or inaccessible sections are not taken into account during the inspection. For a more comprehensive analysis, it is advised to seek assistance from a qualified roofing professional. Only the readily visible and accessible sections of the roof were inspected on the day of assessment.The purpose of the inspection is to determine general condition, NOT to determine life expectancy.
Info and LMT's. An aerial drone was used for the roof evaluation. It is understood that this inspection method is not as thorough as if the roof surface could be walked and is considered a limited inspection. Any comments in this report relating to the roof covering, roof protrusions, gutters, chimneys, etc., are limited to the visible perspective of the drone. If a more thorough inspection is desired, I recommend consulting a roofing contractor before the end of your inspection contingency.
Info and LMT's. Please note that when inspecting composition roof installations, I try and look under shingles to see how the shingles have been fastened. Proper fastening is critical for successful roof performance. Often the shingles are bonding so well, they cannot be lifted to inspect the fastening. In this case, I was unable to lift the shingles and see the fastening pattern - they are bonded well and I do not use a flat bar to pry them apart as part of a visual inspection unless there is a reason to start chasing visible leaks. While this limits my visual inspection, this is a good sign, as loose, un-bonded shingles can lead to wind damage and would be written up as a defect.
Info and LMT's. The information provided below is based on general observations and industry standards and should be treated as a rough estimate. Determining the exact age of a roof without official records or professional inspection is challenging and may not always be accurate. Factors such as maintenance history, climate conditions, and quality of materials can significantly affect the lifespan of a roof. It is strongly recommended to consult with a qualified roofing professional for a thorough inspection and assessment of your specific roof. The information provided in this disclaimer is not intended as a substitute for professional advice, and any actions taken based on this information are solely at the discretion and responsibility of the individual. The accuracy or completeness of the estimation cannot be guaranteed, and no liability is assumed for any damages, losses, or inconvenience arising from the use of this information.
Roof Covering – Localized Damage Present
Damage is present to portions of the roof covering. The affected materials may be more vulnerable to water penetration and weather-related deterioration, particularly during severe weather events.
Recommendations:
Have the builder or qualified roofing contractor replace damaged shingles and review adjacent roof areas for similar damage. Repairs should use compatible materials and be completed in accordance with the roofing manufacturer's installation requirements to maintain proper weather resistance and applicable warranty coverage.
Key Points:
- Localized damage may allow moisture intrusion.
Shingle(s) Not Properly Adhered
One or more roof shingles were observed that had not properly adhered or sealed to the underlying shingles. Unsealed shingles are more susceptible to wind uplift, displacement, and moisture intrusion and may affect the long-term performance of the roof covering.
Recommendations:
Have the builder or qualified roofing contractor correct shingles that have not properly adhered or sealed. Work should be completed in accordance with the roofing manufacturer's installation requirements and should include reviewing adjacent roof areas for similar installation conditions. Damaged shingles should be replaced as needed to maintain proper weather resistance and applicable warranty coverage.
Key Points:
- Unsealed shingles are more susceptible to wind uplift and displacement.
6.5 Flashings, Valleys and Penetrations
Flashing Styles and Roof Penetrations: Metal Flashing, Plumbing Stack Vent
Representative visible roof flashing components were inspected for conditions commonly associated with proper water management at roof transitions, penetrations, terminations, and directional changes in the roofing system. Roof flashings are intended to help direct water away from vulnerable areas where roofing materials start, stop, intersect, or are penetrated. The inspection included reviewing flashing methods and conditions that are generally considered standard or commonly accepted for this region and type of construction. Damaged, incomplete, deteriorated, or non-standard flashing details may indicate an older or potentially less reliable roofing assembly and can increase the likelihood of moisture intrusion over time. Any reportable flashing deficiencies identified in the representative visible areas inspected are documented below where applicable.
Representative visible portions of the roof flashings were inspected for significant deficiencies at applicable flashing locations, including drip edge, sidewall, headwall, counter flashing, step flashing, and similar components. Many flashing components are concealed beneath roofing materials and/or wall claddings and are not directly visible during a standard visual inspection; therefore, concealed portions are excluded from this inspection. Flashing performance is assessed primarily through visible conditions and by reviewing accessible interior ceilings, attic spaces, and roof decking for signs of moisture intrusion where flashing components are presumed to be present. No reportable deficiencies were visibly present at the representative visible portions inspected unless otherwise described within this section.
Representative visible portions of the roof protrusions and penetrations were inspected for significant defects, including signs of deterioration, improper sealing, flashing concerns, and visible moisture intrusion conditions. Roof protrusions were also reviewed from accessible attic areas, where possible, for visible signs of leakage or moisture-related staining at associated roof penetrations. No significant deficiencies were noted unless otherwise described within this section.
Missing Drip Edge Flashing
Drip edge flashing is missing at portions of the roof edges. Drip edge helps direct water away from the roof decking and fascia while supporting proper water management at the roof perimeter. Its absence may allow moisture to reach underlying wood components, contributing to deterioration of the roof edge, fascia, soffit, or roof sheathing over time.
Recommendations:
Have a qualified roofing contractor install drip edge flashing where missing. The scope of work may reasonably include lifting and reinstalling roofing materials as needed, installing compatible drip edge flashing, verifying proper integration with the underlayment and gutter system, and assessing adjacent roof edge sections where similar conditions may exist.
Key Points:
- Drip edge helps direct water away from the roof edge and into the gutter system.
- Missing flashing can allow moisture to affect fascia, soffits, and roof sheathing.
Missing Kick-Out / Re-Direct Flashing
Missing kick-out flashing is present at portions of the roof-to-wall intersections. Conditions like this may allow roof runoff to concentrate against exterior wall surfaces and can contribute to concealed moisture intrusion or deterioration of siding and underlying materials over time.
Recommendations:
If the home is newer construction or may still fall within a builder warranty period, consultation with the builder is recommended. Corrective work may include installation of missing kick-out flashing and review of roof-to-wall water-management details to confirm the assembly performs as intended.
Key Points:
- Kick-out flashing helps divert roof runoff away from exterior walls
6.6 Gutters and Downspouts
Gutter and Downspout Materials: Aluminum
Representative visible portions of the gutters and downspouts were inspected for significant deficiencies related to securement, debris accumulation, standing water, drainage performance, damage, and general condition. Active leakage conditions cannot always be confirmed unless rainfall is occurring at the time of inspection, and minor seepage at seams, joints, or end caps may develop over time due to seasonal movement, aging sealants, or debris buildup. If leakage becomes apparent after occupancy, maintenance, sealing, or localized repairs may be needed. No significant deficiencies were noted unless otherwise described within this section.
6.7 Chimneys
Chimneys Present: Not Present
6.8 Skylights
Skylights if Applicable: Not Present
Ch. 7 Garage
7.1 Garage Overview Photos
7.2 Garage General
Garage Type: Attached
7.3 Garage Fire Separation
Garage Occupant Door: Fire Rated, Hinges Missing
The representative visible garage occupant door(s) were inspected for significant damage, safety concerns, and installation-related deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Missing Self-Closing Hinges at Garage-to-Interior Door
The garage-to-interior door does not have self-closing hinges installed. While this may not have been required at the time of original construction in some homes, self-closing operation is considered a valuable modern safety feature intended to improve separation between the garage and living areas.
Recommendations:
I would encourage the builder to improve this condition for safety. Improvements may include installing or adjusting self-closing hardware, confirming the door latches properly, and reviewing related garage separation components to help support safer long-term performance consistent with modern construction practices.
Key Points:
- Self-closing garage doors help limit the spread of smoke and fumes into living areas
Note:
- Requirements and enforcement related to self-closing garage-to-house doors have varied over time depending on the applicable construction standards and local adoption practices. Regardless of the specific standard in place at the time of construction, self-closing hinges are generally considered a beneficial safety feature that may help reduce the unintended movement of smoke, fumes, and fire-related conditions from the garage into the living space if the door is accidentally left open.
7.4 Garage Doors and Automatic Openers
Overhead Garage Door Type: Metal
Automatic Garage Opener: None noted
The representative visible garage door system, including the door panels, rollers, tracks, brackets, and springs, was inspected for significant damage, loose components, and operational concerns. No significant deficiencies were identified unless otherwise noted within this section.
The representative visible garage door(s) were operated using the wall-mounted control and inspected for proper operation, significant damage, and installation-related deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Ch. 8 Fuel Storage and Distribution
8.1 General Comments
Fuel Sources Present if Applicable: Fuel Sources Present
8.2 Gas Meter
Gas Meter Present: Present
Gas Pipe Materials: Steel and flex pipe
Gas meter present and located on the side of structure
The representative visible gas meter and associated components were inspected for significant damage, improper installation, gas leakage indicators, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
8.3 Gas, Propane and Oil Piping
Gas Piping Materials Noted: Steel, CSST
The representative visible gas distribution piping was inspected for significant damage, corrosion, inadequate support, improper materials, and evidence of gas leakage. No significant deficiencies were identified unless otherwise noted within this section.
8.4 Oil Storage
Oil Storage if Applicable: Not Present
8.5 Propane Storage
Propane If Applicable: Not Present
Ch. 9 Electric Service
9.1
Per the Standards of Practice, the home inspector shall observe Service entrance conductors; Service equipment, grounding equipment, the main overcurrent device, main and distribution panels; Amperage and voltage ratings of the service (if the conductors' sizing text is present/legible); Branch circuit conductors, their overcurrent devices, and the compatibility of their ampacities and voltages. The home inspector shall describe Service amperage and voltage (if known), Service entry conductor materials, Service type as being overhead or underground, and the location of main and distribution panels. The home inspector shall report on: the presence of any observed aluminum branch circuit wiring.
The home inspector is not required to: Insert any tool, probe, or testing device inside the panels; Test or operate any over-current device except ground fault circuit interrupters; Dismantle any electrical device or control other than to remove the covers of the main and auxiliary distribution panels; or Observe: Motion or Dusk to Dawn lighting, Low voltage systems; Security system devices, heat detectors, or carbon monoxide detectors; Telephone, security, cable TV, intercoms, or other ancillary wiring that is not a part of the primary electrical distribution system.
9.3 Electric Service Permits Found
Permits Stickers Found: No Permits Found
9.4 Electric Service Voltage Tested
Service Voltage: 120/240
Info and LMT's. The service amperage is determined by inspecting the service entrance conductors size as well as the service disconnects size. Voltages are not tested for and therefore not confirmed, so 120/240VAC is presumed unless noted in report. In some situations the sizing of the service entrance conductors will not be legible or marked and the stated amperage will be followed by "presumed" as it could not be verified.
9.5 Electric Service
Service Entrance: Below Ground
Meter Base Amperage: 200
Power was supplied to the home by an underground electrical service. The representative visible components of the electrical service entrance, including the electric meter and service entrance equipment, were inspected for significant defects related to damage, improper installation, and other readily visible safety hazards. No significant deficiencies were identified unless otherwise noted within this section.
200 Amp Meter
This home is equipped with a 200-amp electrical meter, which is the standard service size for most modern homes. A 200-amp service provides ample electrical capacity to support typical household needs, including central air conditioning, electric ranges, water heaters, and other high-demand appliances. The meter measures the amount of electricity used and is typically located on the exterior of the home where the main service enters. This setup is generally considered sufficient for today's energy demands and allows room for future expansion if needed.
9.6 Electric Service Equipment
Main Electric Panel Location: Basement
Panel Manufacturer: Eaton
Main Panel Amperage: 200 amps
The representative visible components of the main electrical panel were inspected for significant defects related to wiring terminations, overcurrent protection devices, grounding and bonding, circuit identification, overcrowding, and other readily visible safety hazards. No significant deficiencies were identified unless otherwise noted within this section.
Eaton is a reputable manufacturer of electrical equipment, producing a range of residential and commercial panels under the Cutler-Hammer brand. These panels are widely used for their reliability and safety features.
Recall Information:
In 2014, Eaton recalled approximately 1,000 residential meter breakers due to easily accessible components that presented a shock hazard. Affected models include the MBED 3042 series residential meter breakers with catalog numbers MBED3042B200BF, MBED3042B200BF6, MBED3042B225PV, or MBED3042PV200BF. These units have gray metallic enclosures and measure about 14½ inches wide by 42½ inches high by 7 inches deep. The recalled units have a single warning label on the bottom of the lower right compartment door, which is secured with a latch and hasp at the bottom.
If you have one of these recalled models, it is crucial to contact a licensed electrician for inspection and potential replacement. Consumers should not open the meter breaker's enclosure themselves.
For more information and to initiate a recall inspection, please visit Eaton's official recall notice:
Link For Potential Recalls
200 Amp
This home is equipped with a 200-amp electrical panel, which is the current standard for most modern residences. A 200-amp service provides ample capacity to support a wide range of electrical needs, including central heating and cooling, multiple large appliances, and numerous electronic devices. This service size allows for future expansion and upgrades, helping to ensure safe and reliable electrical performance. Regular inspection and maintenance are recommended to keep the system in good working order.
9.7 Sub Panel
Sub Panel If Applicable: Not Present
9.9 Electrical Grounding System
Electrical Grounding System: UFER Ground Not Visible
Info and LMT's. During a home or property inspection, every effort is made to inspect the visible components of the electrical system grounding. The grounding system is critical for safely discharging electrical surges, especially in the case of lightning strikes. There is no way in the context of a home inspection to verify the "effectiveness" of the grounding system as much of the system is not visible and there are not practical tests one can perform in the way we can test a furnace or a plumbing fixture. However, there are many things that can lead me to recommend further evaluation of the grounding system by a licensed electrical contractor and they will be documented in the observations below if discovered.
9.10 Electrical Bonding System
Notes and Limitaions: Present - Could Not Confirm, Bonding Noted on Gas Pipes
Info and LMT's. During the inspection, I attempt to visually document electrical system bonding. There is no way in the context of a home inspection to verify the "effectiveness" of system bonding. All metallic systems in the building are required to be "bonded" (connected) to the the building's electrical grounding system. Bonding creates a pathway to shunt static charges (that would otherwise build up on the system) to earth, and to provide a pathway to trip a breaker in the event that these bonded metallic components became energized. There are many things that can lead me to recommend further evaluation of this system by a licensed electrical contractor and they will be documented as repair items in the observations below if discovered.
Ch. 10 Electric Distribution and Finish Wiring
10.1 Branch Wiring
Wire Material: Copper
Wiring Method: Non-metallic sheathed cable
The representative visible components of the branch wiring system were inspected for significant defects related to wiring methods, terminations, junction boxes, conductor materials, support, physical damage, and other readily visible safety hazards. Most branch circuit wiring is concealed within walls, ceilings, floors, and insulation and is not visible as part of a visual home inspection. No significant deficiencies were identified unless otherwise noted within this section.
10.2 Receptacles and Fixtures
Inspection Method: Representative Testing
Electric Receptacles: Three wire receptacles
Readily accessible receptacles were inspected by visual examination and tested with an appropriate receptacle tester, where applicable, to evaluate their general operation and wiring configuration. Receptacles that were obstructed, inaccessible, or otherwise not safely testable were excluded from inspection. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Receptacles of 220V/240V and 20-amp dedicated circuits are not assessed for functionality or polarity during the inspection, as they cannot be tested using a standard receptacle polarity tester. Any visible deficiencies pertaining to these receptacles will be noted in the report.
Info and LMT's. Fully confirming or locating GFCI protection in certain areas of the home may be challenging as the protection mechanisms are not always visible. When test and reset buttons are not present on each receptacle, tripping them with a polarity tester might inadvertently affect downstream receptacles that are obstructed by personal belongings or otherwise inaccessible. This could result in those receptacles losing power. I suggest verifying GFCI protection in all recommended areas after personal belongings have been removed or upon assuming ownership of the property. If you're unsure about this process, it's advisable to enlist the services of a licensed electrician for assistance.
Inoperative Outlet
One or more electrical outlets were inoperative at the time of inspection without any clearly identified switch control or GFCI protection. This condition raises concern for possible wiring defects, failed connections, or circuit-related issues that may impact electrical safety and system reliability.
Recommendations:
Have the builder or qualified electrician correct the inoperative receptacle and verify proper operation. Work should include determining the cause of the condition and reviewing associated electrical components for proper installation and function as needed.
Note:
- Electrical work appeared to remain in progress, and the condition may be related to incomplete installation, connections, or circuit activation. Final operation should be verified by the builder upon completion of the electrical work.
Loose Electrical Receptacle
The receptacle is noticeably loose within the wall assembly. Continued movement may contribute to deteriorated wiring connections, intermittent operation, or increased risk of electrical faults over time.
Recommendations:
This appears to be a relatively minor installation-related item that should be brought to the builder's attention. Corrective work may reasonably include securing the receptacle to the electrical box, repairing or replacing mounting hardware as needed, verifying proper support of the device, and reviewing nearby receptacles where similar installation concerns may be present. Any available warranty coverage or responsibility for corrective work should be verified directly with the builder, electrical contractor, or warranty provider.
Cover Plates Missing
One or more electrical boxes are missing cover plates, leaving wiring or electrical components exposed. This condition increases the risk of accidental contact and is not consistent with commonly accepted electrical safety practices.
Recommendations:
Have the builder or qualified electrician install missing electrical cover plates and review adjacent electrical devices for similar incomplete items prior to closing or occupancy.
10.3 Ceiling Fans and Lighting
Lighting: Present and Tested
Representative readily accessible lighting fixtures were inspected by visual examination and operated using normal controls to evaluate their general functionality and identify readily visible safety concerns. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Exterior dusk-to-dawn lights, motion lights, landscape lighting, or any lighting fixtures not affixed to the structure are not encompassed within a standard home inspection and were not evaluated for functionality. These elements are explicitly excluded from the inspection.
Loose Light Fixture
The light fixture is loose and not securely fastened at its mounting location. This condition can allow movement at the fixture, which may affect electrical connections and presents a potential safety concern if the fixture becomes unstable over time.
Recommendations:
This would be a reasonable item to discuss with the builder. The fixture appears loose at the mounting location and may simply require adjustment, tightening, or improved support. Having the builder correct the installation and review similar fixtures may help ensure the lighting components are securely mounted and performing as intended.
10.4 Smoke and Carbon Monoxide Alarm Systems
CO Alarms Noted: On Main Floor, In Basement
CO Alarms: Present
Smoke Alarms Noted: On Main Floor, In Basement, In All Bedrooms
Smoke Alarms: Present
The installation of carbon monoxide alarms is recommended for all homes that have fuel burning appliances such as gas or oil furnaces, gas water heaters, gas ovens and cooktops, gas fireplaces and wood stoves. The location should be: at least one alarm outside of all sleeping areas and one on each floor of the house. Best practices are to have these alarms hardwired with a battery back-up - though requirements are for the installation to meet manufacturer's specifications. Carbon monoxide is a colorless, odorless gas that can cause sickness, nausea and even death. Alarms have a useful service life of roughly 6 years, so changing them more frequently than smoke alarms is recommended.
The link below includes important information about smoke alarms that could save lives in the event of a fire. There are two basic types of smoke alarms: ionization, which are better at detecting flaming fires and photoelectric, which are better at detecting smoldering fires. Standards in the building industry are moving toward recommending BOTH types of detectors in the home. It is nearly impossible to accurately test smoke alarms during a home inspection. I recommend learning more about these important life saving devices and consider installing both types of smoke detectors in your home. http://getscribeware.com/blog/wp-content/uploads/2016/04/Ionization-vs-photoelectric.pdf
Smoke detectors, also known as smoke alarms, are designed to detect smoke and alert occupants of a building to the presence of a fire. The frequency with which smoke detectors should be tested and maintained depends on the type of detector and the manufacturer's recommendations.
Most smoke detectors should be tested at least once a month to ensure that they are functioning properly. This can be done by pressing the "test" button on the detector, which will cause it to emit a loud alarm sound. If the alarm does not sound, the detector may need new batteries or may need to be replaced.
In addition to monthly testing, smoke detectors should be cleaned regularly to ensure that they are free from dust and other debris that can interfere with their operation. This can be done by gently vacuuming the detector or wiping it with a clean, dry cloth.
Smoke detectors also have a limited lifespan, typically ranging from 5 to 10 years depending on the type and model. Manufacturers usually recommend replacing smoke detectors after this time to ensure that they continue to function properly.
In summary, smoke detectors should be tested at least once a month, cleaned regularly, and replaced after their recommended lifespan to ensure that they are functioning properly and can alert occupants to the presence of a fire.
As a safety precaution, It would always be my recommendation to update or replace all smoke or carbon detection systems when acquiring a new home.
Info and LMT's. During the home inspection, I try and test a representative sample of the smoke alarms by using the test button on the alarms. This is NOT an accurate test of the sensor just a test to see if the unit is powered. For reliability, fire marshals recommended updating smoke alarms every 10 years and changing batteries bi-annually. The latest data indicate that we should be using photoelectric technology in our smoke alarms for improved fire detection and to reduce problems with false alarms which can lead to disabling of this important safety system. Unfortunately, the alarms have to be removed to determine if they are photo-electric or ionization types. It is surprisingly complex to accurately test a smoke alarm system and determine the reliability, age, and type of sensor technology used, especially as many homes can have half a dozen or more alarms throughout the house. A complete evaluation of smoke alarms is beyond the scope of this inspection. For optimal fire safety, I recommend taking control of these important safety devices and learning about how to service and maintain your smoke alarm system to keep the building occupants safe. For more information, please read this link. For more information, please read this link.
Ch. 11 Heating, Cooling, Fireplaces and Ventilation
11.1
Per the Standards of Practice, the home inspector shall observe the permanently installed heating and cooling systems, including Heating and cooling equipment central to the home; visible ducts and piping, air filters, registers, and the presence of an installed heating and cooling source in each room. The home inspector shall describe the energy source and heating equipment. The home inspector shall operate the systems using normal operating controls. The home inspector shall open readily accessible access panels provided by the manufacturer or installer for routine homeowner maintenance. The home inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe Humidifiers, Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. The efficiency of the units and load testing is not conducted. Air conditioning units cannot be tested when temperatures are lower than 60 degrees due to the possibility of damaging the compressor. Clients are advised to have an HVAC company perform maintenance on the system annually.
11.2 Thermostat
Location: Living Room
11.3 Cooling Systems
Cooling System: Present
Data Plate
Manufacturer: Lennox
Listed Nominal Capacity: 3 Tons
Energy Source: Electric
System Type: Air Source
Age: 2026, New
The representative visible components of the exterior cooling unit(s) were inspected for significant defects related to installation, physical condition, operation, refrigerant line connections, electrical components, and other readily visible deficiencies. The system was operated using normal controls to verify the production of conditioned air, weather permitting. No significant deficiencies were identified unless otherwise noted within this section.
It's important to be aware of how long air conditioners last, so you don't get the unwelcome surprise of a broken air conditioner in the peak of the summer heat. In general, air conditioners that are properly maintained can last 15 to 20 years.
Delta T-Note
According to commonly accepted home inspection industry standards, there should be a 15-20 degree F difference in temperature between the return air duct and the supply air ducts, after about 20 minutes of operation. This is supposed to give the inspector a rudimentary indication of whether the unit is functioning or not. Documenting this split is required when feasible by the Home Inspector Standards of Practice and I must emphasize the test is relatively meaningless. Humidity, outdoor air temperature, air flow speed, coolant fluid pressure, leaking ducts, duct location, air filter condition and other considerations impact true efficiency and function. When there is less of a differential or a greater differential further evaluation by a qualified HVAC contractor may be warranted and generally is warranted. Nothing stated in the report should ever be construed to mean the system is "properly functional" or "fully functional" as that is only something that can be determined by complicated and invasive testing by a licensed HVAC contractor which is always recommended in the context of your due diligence.
Basic Maintenance Recommendations
Regular cooling system maintenance is important. Due to the numerous causes of any system malfunction, assessment by a qualified cooling serviceman is advisable. Periodic refrigerant recharging may be needed; such conditions may not be predictable.
Condensate back up or leakage can lead to Mold or what looks like mold.
The outdoor unit base should be maintained in a reasonably level position. The coils will require periodic cleaning; clearance from vegetation/obstructions should also be provided.
Clean air filters not only improve the living environment, they also help maintain the Air Conditioner components by providing proper cooling of the internal parts and reducing dust accumulation in key components.
The following list is a minimum set of requirements to be expected of heat pump or air conditioning servicing. I provide these as a courtesy to show they types of check-ups that should be expected from a professional servicing.
- Check compressor efficiency
- Check refrigerant level
- Clean the condenser coil
- Change or clean air filters
- Inspect contacts and wiring
- Inspect drive-sheaves, pulleys and belts
- Check and adjust for proper air flow
- Clean the blower motor as needed
- Lubricate all motors and shaft bearings
- Check, calibrate and program the thermostats and be sure the thermostat has adequate batteries as needed
- Check unit smoke detector, clean filter if applicable
- Check safety disconnect, laser-temp -- check across contacts
Lennox Industries is a well-established American manufacturer of heating, ventilation, and air conditioning (HVAC) systems. While Lennox is known for producing high-quality air conditioning units, certain models have been subject to recalls due to safety concerns.
Follow this link for any potential recalls: https://www.cpsc.gov/Recalls
11.4 Heating System
Heating System: Present
Data Plate
Loction: Basement
Energy Source: Natural gas
Manufacturer: Lennox
Last Service Record: None
Listed Max Capacity Per Data Plate: 66,000 btu's
Heating Method: Gas forced air furnace
Age: New
The representative visible components of the interior cooling unit(s) were inspected for significant defects related to installation, physical condition, operation, condensate management, electrical components, and other readily visible deficiencies. The system was operated using normal controls to verify the production of conditioned air. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. The HVAC system inspection is restricted to assessing the system's response to normal operating controls, including the thermostat, in both heating and cooling modes (subject to weather conditions). It also involves visually observing the exterior and interior equipment non-invasively and removing any access panels designed for easy removal by homeowners without the need for tools. For a more comprehensive inspection, it's advisable to consult an HVAC contractor.
This house has a gas forced air furnace. A critical component to all combustion heating equipment is the heat exchanger. This is the welded metal assembly inside the furnace that contains the products of combustion so that moisture, carbon monoxide and other products of combustion do not mix with interior air and get safely vented to the exterior. Heat exchangers on modern furnaces have an average life expectancy of 15-20 years. Unfortunately, heat exchangers are concealed inside the heating equipment; they are not visible and specifically excluded from a home inspection. Cracks in heat exchangers may be concealed and can pose a potential safety hazard.
Although some furnaces can last more than 40 years (extremely rare), the average life of a furnace is around 15 to 30 years. As long as you have scheduled annual furnace maintenance, it should easily last over 15 years. Just like your car, your older furnace may need some basic repairs.
Forced Air Furnace Servicing Recommended
Although this is a new installation, regular professional servicing is still recommended to help support safe and efficient operation, maintain manufacturer-recommended performance, and identify developing concerns before more significant issues occur. Establishing a routine maintenance schedule from the beginning of ownership may help extend the service life of the system, preserve manufacturer warranty requirements where applicable, and provide a documented service history for future reference.
Furnace Inoperative – Operation Not Verified
The furnace did not operate when tested. It could not be determined whether the gas supply was active or whether the condition was related to incomplete construction, system setup, or an equipment-related issue. As a result, proper furnace operation could not be verified during the inspection.
Recommendations:
Have the builder and/or qualified HVAC contractor verify that the gas supply is active and place the furnace into normal operation. The system should be fully tested and any deficiencies corrected prior to occupancy or closing.
Construction Dust at Furnace
Drywall and/or construction dust was observed within portions of the furnace. Construction debris can accumulate on HVAC components, restrict airflow, and affect system performance if not properly cleaned.
Recommendations:
Have the builder or qualified HVAC contractor clean and service the furnace and accessible system components as needed. Replace the HVAC filter and verify the system is clean and operating properly prior to occupancy.
11.5 Air Filters
Air Filter Size: 16 x 25 x 1
Notes: Filters Are Located at Cold Air Returns, Be Sure to Change or Clean Quarterly
Filtration Systems: Disposable
HVAC Air Filter – Dirty
The HVAC air filter is heavily soiled, restricting normal airflow through the system. Reduced airflow may affect comfort, efficiency, and place unnecessary stress on heating and cooling components if not addressed.
Recommendations:
I would recommend the builder or qualified HVAC contractor replace the dirty air filter and verify proper airflow and system operation. Where construction dust or debris is present, accessible HVAC components should also be reviewed and cleaned as needed prior to occupancy.
Key Points:
- Dirty air filters reduce airflow and HVAC efficiency.
11.6 Vents and Flues
Vents and Flue Style: High Efficiency
The representative visible components of the combustion venting system were inspected for significant defects related to vent materials, clearances to combustibles, support, slope, connections, termination, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
High-Efficiency Furnace PVC Vent Termination
The furnace PVC vent termination may not fully reflect modern installation and protection practices intended to help reduce the likelihood of debris intrusion, pest entry, snow blockage, or airflow restriction at high-efficiency appliance vent systems.
Recommendations:
This appears to be more of an installation-detail concern than a current performance failure. If the property is newer construction, having the builder review the vent termination and make any recommended improvements may help support safer and more consistent airflow at the furnace venting system.
11. 7 Heating and Cooling Distribution Systems
Distribution Method: Forced Air / Ducts
Heat Source in Each Room: Present
Info and LMT's. An infrared camera was utilized to demonstrate that the system(s) responded to normal operating controls during the inspection. However, these images are not intended to depict the precise temperature differential, efficiency, or performance of the system, as these aspects fall outside the scope of a home inspection. For accurate readings, HVAC thermometers (wet bulb) are necessary, and an HVAC contractor would conduct measurements at different locations.
In cooling mode, typical temperature differentials between return and supply air can range from 12 to 20 degrees, while in heating mode, they can range from 15 to 25 degrees. Numerous factors, including indoor and exterior ambient air temperatures, humidity levels, and the condition of the air filter and evaporator, among others, can influence these values.
Missing or Damaged Heat Register Covers
One or more heat register covers are missing or damaged. This can leave duct openings exposed, affect airflow distribution, and allow debris or objects to enter the ductwork.
Recommendations:
Have the builder or qualified HVAC contractor install or replace missing or damaged register covers prior to occupancy. Covers should be properly sized, securely installed, and free of damage. Review remaining supply and return openings for similar incomplete or damaged components.
11. 8 Mechanical Ventilation Systems
Whole House Fans, Ventilation and HRVs: Present
Attic Terminations: Fans Visibly Connected and Venting Out
The accessible exhaust fan vents in the attic were noted to be correctly terminating to the exterior where visible.
This building has a house ventilation fan timer. You typically want this set for at least two hours / day though this does depend on occupant behavior. The goal is to keep indoor relative humidity below 50% during cold weather.
11.9 Gas Fireplaces
Gas Fireplace(s) If Applicable: Present, In Process
The representative visible components of the gas fireplace were inspected for significant defects related to installation, operation, venting (if applicable), burner performance, safety controls, clearances, and other readily visible deficiencies. The fireplace was operated using normal controls, where possible. No significant deficiencies were identified unless otherwise noted within this section.
Gas Fireplace – Installation in Progress / Not Tested
The gas fireplace installation appeared to remain in progress at the time of the inspection and was not tested for operation. Final installation, setup, and proper operation should be completed and verified by the builder or qualified contractor prior to occupancy.
11.10 Wood Burning/Solid Fuel Fireplaces
Wood Burning Fireplace If Applicable: Not Present
11. 11 Additional Heat Sources
Description: Not Present
Ch. 12 Plumbing
12.1
Per the Standards of Practice, the home inspector shall observe at visible portions: Interior water supply and distribution system, including piping materials and supports; fixtures and faucets; functional flow; leaks; and cross-connections. Interior drain, waste, and vent system, including traps; drain and waste lines; leaks; and functional drainage. The home inspector shall describe Water supply and distribution piping materials; Drain, waste, and vent piping materials; and the Location of the main water supply shutoff device. The home inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance.
The home inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials.
12.2 Water Meter
Water Meter Location: Location of Water Meter Note
12.3 Water Service Supply
Pipe Material: Plastic
Water Supply: Public water
Pressure Reducing Valve: None noted
Water Pressure: 95 PSI
Info and LMT's. Plastic/PEX-Type Water Service Piping.
Blue plastic water service piping was present; no visible markings were identified at the observed section to confirm manufacturer or product type.
High Water Pressure Noted
The plumbing system appears subject to elevated water pressure conditions. Excessive pressure can increase stress on fixtures, valves, piping connections, and water-using appliances, potentially contributing to accelerated wear or plumbing failures over time.
Recommendations:
I would have the builder improve the plumbing pressure regulation as recommended. Improvements may include adjusting or installing pressure-reducing equipment, verifying system operating pressure, and reviewing related plumbing fixtures and appliances to help support reliable long-term performance consistent with modern plumbing practices.
Key Points:
- Water pressure above 80 psi is generally considered high and can put stress on pipes, fixtures, and appliances.
- High pressure may cause leaks, burst pipes, or premature wear on plumbing components.
Note:
- Water pressure was measured at a hose bib, which provides a general reading but may not be as accurate as a pressure reading taken from the washing machine supply lines
12.4 Distribution Pipe
Supply Pipe Materials: PEX
Pipe Insulation: Not Visible
Circulation Pump: Not Present
Functional Flow: Average
The representative visible components of the water supply piping system were inspected for significant defects related to leaks, physical damage, improper installation, support, corrosion, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. This building has PEX tubing used for supply piping. Crimp ring connections on PEX pipe have very specific installation guidelines and most of these connections will not be visible at the time of inspection (just like any other type of pipe fitting). It is beyond the scope of this inspection to evaluate a significant number of these connections. Any leaking noted at fittings should result in more careful inspection of all of the plumbing system by a licensed plumber that is experienced in the installation of these types of connections
Info and LMT's. Sections of the plumbing system that are concealed by finishes, storage areas, walls, floors, ceilings, below the structure, or beneath the ground surface were not inspected. Supply piping and other concealed plumbing cannot be fully evaluated, and its condition, installation quality, or potential for leaks cannot be verified. Overflow backup was not tested to avoid the risk of water damage, as aged gaskets may fail. Continued monitoring for signs of leakage or damage is recommended, and evaluation by a licensed plumber may be warranted if concerns arise
This video demonstrates the system’s functional flow as observed during the inspection.
Inadequate Pipe Supply Pipe Support
Portions of the plumbing supply system appear improperly supported or insufficiently secured. Excessive movement or sagging can place ongoing stress on pipe connections and may contribute to leakage, noise, or reduced long-term plumbing performance.
Recommendations:
The builder should improve the affected piping support installation as recommended. Improvements may include adding or adjusting pipe supports, improving fastening methods, and reviewing similar accessible plumbing areas to help support reliable long-term plumbing performance consistent with modern installation practices.
Key Points:
- Unsupported piping can shift and place stress on fittings and joints
- Excessive movement may contribute to leaks or premature plumbing wear
Notes:
- PEX pipe should have supports every 32 inches.
12.5 Waste Pipe and Discharge
Discharge Type: Public Sewer - Buyer
Waste and Vent Pipe Materials: PVC
Location of Sewer Cleanout: Basement
The representative visible components of the drain, waste, and vent (DWV) piping system were inspected for significant defects related to leaks, physical damage, improper installation, support, proper drainage, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Only visible portions of the plumbing waste and drain systems could be inspected. Concealed piping and underground drains were not accessible, and full verification of flow or blockages is beyond the scope of this inspection.
A video camera sewer scope is recommended
. Even in new construction, a sewer scope is recommended to confirm that the main drain line was properly installed and free of construction debris, sags, or damage. Issues such as poor grading, crushed sections, or blockages can occur during the building process and may not be visible without a camera inspection.
12.6 Water Heater
Manufacturer: Bradford-White
Data Plate
Energy Source: Electricity
Size: 50 gal
System Type: Tank
Bollard: None Required
Straps : Not Present
Expansion Tank: None Noted - Recommended
Drain Pan: Present with drain
Age: 2025
Relief Valve: Present - Not Tested
The representative visible components of the water heater were inspected for significant defects related to installation, operation, venting (where applicable), safety controls, plumbing and electrical connections, and other readily visible deficiencies. The water heater was operated using normal controls, where possible. No significant deficiencies were identified unless otherwise noted within this section.
Per the Standards of Practice, the inspector will examine and report the condition: of the water heater enclosure, plumbing supply, energy source, venting, and TPR valve, if applicable. The inspector is not required to: activate the system if it is powered down or the pilot flame is not lit, Inspect the system for proper sizing, design, or use of proper materials.
Water Heater Average Lifespan
A hot water heater's lifespan depends on many factors, including the type of water heater, the energy source, the type of water you have, and how well the unit is maintained. On AVERAGE, most water heaters last between 8 and 12 years but some can last up to 20 years with regular maintenance.
TPRV - Description
A temperature and pressure relief valve (TPRV) is required on all water heaters to discharge any excessive pressure within the tank. A discharge pipe should be attached to the valve and directed to a safe location away from body contact. Newer installations must be directed to the building exterior or to an approved indoor drain receptor. Most manufacturers suggest that homeowners test these valves at least once a year by lifting the lever to ensure the valve discharges properly and also recommend inspection of these safety devices every three years. The picture here shows a typical TPRV. They may also be found on the side of the heater on some models. I do not test these valves due to the possibility that they may leak after testing. A leaking or inoperative TPRV should be replaced immediately by a licensed plumber.
Due to inconsistencies between both UPC and IPC Plumbing codes, and water heater manufacturer's instructions, and TPRV manufacturer instructions, it is not actually possible to install the drain from the Water Heater TPRV "properly." There are conflicts with distance of termination to the floor/ground, types of pipes approved, and diameters of pipes approved. Additional confusion is added when jurisdictional inspectors approve installations/materials specifically not allowed by both codes and manufacturers. My recommendations will vary depending on the installation and will be included in the applicable narratives below.
Most codes defer to manufacturer instructions and I favor those recommendations. The yellow tag on the valve states clearly the termination should be 6" above the floor which is more consistent with the UPC code requirements.
Bradford White
This home is equipped with a water heater manufactured by Bradford White. Bradford White is a respected U.S.-based brand that produces gas, electric, and tankless water heaters primarily sold through professional installers. Typical lifespan for a tank-style unit is around 8–12 years, depending on water quality, usage, and maintenance.
Regular upkeep can help maintain efficiency and extend the life of the unit. For more information, visit the Bradford White Website.
Tank Style Water Heater
A standard tank-style water heater stores and heats a set amount of water—typically 30 to 80 gallons—for household use. It operates by filling the tank with cold water through a dip tube, then heating that water using either electric heating elements or a gas burner located near the bottom of the tank.
As the water heats, it rises to the top of the tank, where it’s drawn off when a hot water fixture is used (such as a faucet, shower, or dishwasher). A thermostat regulates the water temperature, typically set between 120°F and 140°F. An insulated tank helps retain heat, while a pressure relief valve provides safety in case of excess pressure or temperature.
Tank-style water heaters heat water continuously to maintain the set temperature, even when not in use, which can lead to standby energy losses.
Water Heater Strapping
The water heater was observed without seismic straps. While Ohio is generally a low seismic risk area and strapping is not required by code statewide, strapping water heaters is recommended to prevent tipping during minor seismic events or accidental impact. A qualified contractor can install straps anchored to wall studs as a safety precaution.
Note:
Practical application in Ohio: Most of Ohio is not in a high seismic zone, so strapping is not strictly required by code statewide, but some local jurisdictions may still require it.
Expansion Tank - None Noted
An expansion tank is recommended for the water heater; these are required if the house has a closed plumbing system. Expansion tanks help reduce pressure on the plumbing system by creating a buffer or a place for water to expand into as water swells during thermal expansion. Installation of expansion or pressure tanks is modern installation practice and will be required if a pressure reducing valve has been installed on a public water supply.
PEX-Electric- 18 Inches PEX
PEX piping is connected near the electric water heater. No visible heat-related damage or other specific deficiency was observed at the accessible piping. Installation requirements can vary by piping and water heater manufacturer; this condition is documented for informational purposes.
Key Points:
- PEX tubing standards. All PEX tubing must meet ASTM F876 and NSF/ANSI/CAN 61 standards.
- PEX fitting standards. ASTM F877 is the standard specification for cross-linked polyethylene (PEX) hot- and cold-water distribution.
- PEX use. PEX should not be used in areas with high heat, such as near recessed lighting or water heater connecting lines.
- Manufacturer. Most professional plumbers recommend using tubing and fittings from the same manufacturer.
Note:
- PEX supply piping was installed too close to the electric water heater. Modern installation practices commonly call for metallic piping or approved transition materials at the water heater connection unless otherwise permitted by the manufacturer.
12.7 Water Temperature
Water Temperature Measured During Inspection: 116 Degrees F
Water Temp-Too Cold
The water heater temperature seemed to be set too low at the time of inspection. The range of 120-125 degrees F is the generally recommended temperature. This is nearly impossible to measure precisely during a home inspection as water temperature can vary between fixtures. I try and test the water temperature in several places and take the median reading. Adjust water heater temperature as needed. For best practice, set water temperature at the water heater to 130 degrees F and use a tempering valve to set water temp back to a safe 120 for domestic use. This high tank temperature will reduce risks of Legionella developing in the tank and the tempering valve will ensure a safe water temperature.
12.9 Exterior Hose Bibs
Hose Bibs if Applicable: Not operating
Outdoor Faucet-Non-Operational
The exterior hose bib does not appear operational. Conditions like this may indicate fixture failure, supply valve concerns, freeze-related damage, or related plumbing issues that could affect long-term performance or result in leakage if left uncorrected.
Recommendations:
I would encourage the builder to restore proper operation of the exterior faucet as recommended. Improvements may include repair or replacement of the fixture, confirmation of proper shutoff and supply piping operation, and review of nearby plumbing connections to help support reliable long-term performance consistent with modern installation practices.
Key Points:
- Non-operational hose bibs limit normal exterior water access
- Freeze-related damage or shutoff issues are common causes of failure
- Early repairs may help prevent future leakage or plumbing deterioration
Note:
- The exterior hose bibs may have also been winterized at the time of inspection and could not be tested. Inquire with the seller to see if they are generally operable.
Ch. 13 Additional Plumbing
13.1 Sump Pumps and Drains
Floor Drain: Basement Floor Drain Present, Cover /Screen Missing
Sump Pumps: Present, Noted - Buyer Note
Info and LMT's. A floor drain was present. I do not test floor drains but I do recommend they be tested for function by the homeowner or a handy-person by running a hose in them for a prolonged time or having them professionally scoped by a qualified plumber. The traps in these drains sometimes dry-out allowing sewer gases and vermin into the home. As a part of routine maintenance I recommend making sure drain trap has water in it and is properly covered.
Info and LMT's. In Ohio, home inspections do not include manual testing of sump pumps. This inspection is limited to the visible components and general operation of the sump pump system, without dismantling equipment or performing invasive procedures. The evaluation includes observations of accessible parts, signs of wear, and whether the pump appears to operate as intended at the time of inspection. This does not guarantee long-term reliability, account for hidden defects, or predict future performance.
Info and LMT's. Sump Pump – General Information
Sump pumps typically have a lifespan of about 7 to 10 years, though this can vary based on factors such as frequency of use, maintenance, installation quality, and overall build. Submersible pumps generally fall within this range, while pedestal models may last longer.
The exact age of the sump pump installed in this home could not be determined during the inspection. Without documentation or visible manufacturing dates, it's not possible to verify how long the unit has been in service.
As with any mechanical component, regular testing and maintenance are recommended. If concerns arise or the unit is older, evaluation or replacement by a qualified plumber or waterproofing specialist may be advisable.
Sump Pump Information
A sump pump system was noted for this building. Inquire with the seller for more information about this pump system; is it needed to keep the building dry? Some sump pumps are installed as a prophylactic measure, other systems are critical for keeping a building dry. The importance of this system is impossible to determine during a one-time inspection. Sump pumps always require maintenance. If it is determined that the pump is critical to maintain a dry basement or crawl space.
I recommend installing:
- Back up power systems so the pump will work in a power outage. Have a back-up pump and an alarm to alert the occupants in case of a pump failure.
Missing Basement Floor Drain Cover
Modern plumbing installations generally include secured or fitted floor drain covers intended to help reduce debris intrusion and improve drainage system protection. The visible condition does not appear consistent with these common plumbing practices.
Recommendations:
I would see if the builder could improve the floor drain assembly as recommended. Improvements may include installing a proper drain cover, confirming trap functionality, and reviewing similar drainage components to help support proper plumbing performance consistent with modern installation practices.
Key Points:
- Proper covers help improve drainage protection and sanitation
13.2 Radon Equipment
Radon Equipment if Applicable: Present
Info and LMT's. This home inspection focuses on the visible components and operation of the radon system. It does not involve dismantling equipment or conducting invasive tests. The inspection covers general functionality, visible signs of wear, and operational testing, but does not account for potential hidden defects, long-term reliability, or future performance.
I would recommend a qualified radon mitigation contractor service and inspect the system periodically to ensure proper operation and continued reduction of radon levels.
13.3 Water Filters
Not Present
13.4.1 Sewage Ejector Pumps
Not Present
13.4.2 Central Vacuum
Not Present
13.4.3 Fire Suppression
Not Present
13.4.4 Irrigation
Not Present
13.4.5 Spa
Not Present
13.4.6 Water Features
Not Present
13.4.8 Sauna
Not Present
13.4.9 Swimming Pools
Not Present
Ch. 14 Interior Living Area(s) and Bedrooms
14.1
Per the Standards of Practice, the home inspector shall observe walls, ceilings, and floors; steps, stairways, balconies, and railings; counters and a representative number of installed cabinets; and a representative number of doors and windows; fireplaces by examining the firebox, operating the damper, and reporting on the presence of a gas shut off valve. The home inspector shall: Operate a representative number of receptacles, switches, windows, and interior doors; and report on signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.
The home inspector is not required to observe: Paint, wallpaper, and other finish treatments on the interior walls, ceilings, and floors; Carpeting, tile; or Draperies, blinds, or other window treatments. Gas fireplaces are not tested for functionality, and the pilot light will not be lit if it's off at the time of inspection. An evaluation by a gas company is recommended before using any gas appliances in the home.
14.2 Interior Overview Photos
The photos provided here show representative images of the living areas at the time of inspection.
Info and LMT's. Assessing the quality and condition of interior finishes involves a significant degree of subjectivity. Factors such as cleanliness, cosmetic imperfections, material quality, architectural aesthetics, and color fall outside the purview of this inspection. Comments provided will be general in nature, unless specific functional concerns are identified. It's important to note that furniture, area rugs, storage items, appliances, and wall hangings are not relocated during the inspection, which may obscure potential defects.
Items such as carpeting, window treatments, central vacuum systems, household appliances, screens, recreational amenities, paint, wallpaper, and other finish treatments are not inspected unless explicitly mentioned in the report. It is recommended to conduct a thorough review of interior areas during the final walk-through inspection before closing. Please note that only areas that were readily visible and accessible were inspected on the day of assessment.
14.3 Walls, Ceilings and Trim
Wall and Ceiling Materials: Drywall
A representative sample of the visible interior wall, ceiling, and trim finishes was inspected to evaluate their general condition and identify any readily visible signs of damage, deterioration, installation concerns, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Interior Trim - Incomplete
Interior trim is missing in one or more areas, leaving exposed gaps or unfinished transitions between materials. In addition to cosmetic concerns, missing trim may reduce protection of adjacent finishes and can allow gaps to remain exposed.
Recommendations:
Missing or incomplete trim should be installed and finished by the builder or appropriate contractor prior to occupancy. Work should include completing affected areas with compatible materials and reviewing nearby finishes for similar incomplete conditions.
14.4 Floors and Floor Materials
Floor Materials: Laminate, Carpet
Floor Settlement: None Noted
A representative sample of the visible and accessible floor system components was inspected to evaluate the overall condition and identify any readily visible signs of damage, excessive deflection, or other structural deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. At the time of inspection, no visible signs of floor settlement, sloping, or structural movement were observed. Floors appeared level and consistent throughout accessible areas, and no related wall or ceiling cracking was noted. These observations are based on visual inspection only and are limited to the conditions present at the time of inspection. Future settlement or movement cannot be predicted.
14.5 Interior Doors and Doorstops
Interior Doors: Hollow Core
A representative number of readily accessible interior doors were inspected by operating them, where possible, to evaluate their general condition, operation, latching, alignment, and identify any readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Top of Door Not Finished/Sealed
One or more door tops are missing protective finish or sealant. Continued exposure to humidity or moisture may increase the likelihood of swelling, finish damage, or reduced door performance over time.
Recommendations:
Consultation with the builder is recommended. Improvements may include sealing unfinished door edges, correcting incomplete finish work, and addressing similar workmanship-related conditions where present.
Note:
- Most doors are shipped without the top edge finishes and finishes are required to be completed on site.
Closet Doors Missing Floor Guides
Closet door floor guides are missing, allowing excessive movement and instability during operation. Conditions like this may increase the likelihood of track damage, hardware wear, door misalignment, or operational failure over time.
Recommendations:
The builder or appropriate contractor should install missing floor guides at affected closet doors and adjust the doors as needed for secure, smooth operation. Nearby closet doors should be reviewed for similar incomplete installation.
14.6 Windows
Window Glazing: Double pane
Interior Window Frame: Vinyl
Window Styles: Single hung
A representative number of readily accessible windows were inspected by operating them, where possible, to evaluate proper operation, latching, weather-tight closure, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
14.7 Additional Interior Cabinets and Countertops
Cabinet Material: Not Present
Countertop Material: Not Present
14.8 Wall Insulation and Air Bypass
Wall Insulation: Not Visible
14.9 Interior Stairs
Interior Stairs If Applicable: Present
The representative visible components of the exterior stair system were inspected by traversing the stairs, where possible, to evaluate their general condition, stability, handrails, guards (where applicable), and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Non-Uniform Stair Riser Heights
Modern stair construction practices generally call for stair risers to remain consistent in height throughout the stairway to help improve safety and usability. The visible stair geometry does not appear fully consistent with those practices.
Recommendations:
Request correction of the inconsistent stair riser heights as part of the builder's final work. The completed staircase should provide reasonably uniform step geometry throughout, with modifications made as needed to address the trip and fall concern and meet applicable requirements.
14.10 Indoor Air Quality
Link to Indoor Air Quality: Link to Indoor Air Quality
The following link can provide you with additional information regarding indoor air quality.
https://www.epa.gov/indoor-air-quality-iaq
Ch. 15 Kitchen
15.1
Per the Standards of Practice, the inspector will examine and report on the condition and operation of the dishwasher by initiating a cycle, the range by testing the heating elements and the oven, the mounted microwave by starting a warm-up cycle, test the hot/cold water supply at the fixture, look for leaks in the plumbing and fixtures/faucet, examine counters, walls, ceilings, floors, a representative number of cabinets, windows, doors, and the presence of GFCI receptacles and their operation, if applicable. Homes built prior to 1987 were not required to have GFCI receptacles in the kitchen, but upgrading is recommended for safety.
The home inspector is not required to report on: Clocks, timers, self-cleaning oven functions, thermostats for calibration or automatic operation; Non-built-in appliances; or Refrigeration units. The home inspector is not required to operate: Appliances in use; or Any appliance that is shut down or otherwise inoperable.
15.2 General Kitchen Pictures
15.3 Sinks and Faucets
The representative visible components of the sink assembly were inspected for significant defects related to fixture operation, water flow, drainage, faucets, shutoff valves, plumbing connections, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
The representative visible supply and drain piping serving the fixture were inspected for significant defects related to leaks, improper installation, physical damage, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Note:
- Thermal images taken during the inspection did not reveal any signs of active leaks at the time of inspection.
15.4 Cabinets and Countertops
Cabinet Material: Wood
Countertop Material: Granite
The representative visible cabinetry and countertops were inspected for significant defects related to physical damage, installation, and other readily visible deficiencies. Representative cabinet doors and drawers were operated, where possible, to evaluate proper operation, alignment, and other readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
This is a great document From the Natural Stone Institute that covers maintenance and installation recommendations for slab surface stone countertops.
Info and LMT's. Please note that some slab granite has been found to contain radon. Radon testing is beyond the scope of this inspection. Further investigation is required if you are concerned about the health risks associated with this product.
Cabinets / Countertops – Protective Coverings
Portions of the cabinets and countertops remained covered with protective plastic or construction materials at the time of the inspection, limiting full visual evaluation of the finished surfaces. Review these areas during the final walkthrough after coverings have been removed for damage, incomplete finishes, or other visible concerns.
15.5 Ranges, Ovens and Cooktops
Heat Source if Applicable : Not Present
15.6 Dishwasher
Dishwasher(s) if Applicable : Not Present
15.7 Refrigerators
Refrigerator(s) if Applicable : Not Present
15.8 Disposers
Disposers if Applicable : Operated
The garbage disposal was inspected by operating it with normal controls to evaluate its basic function and identify any readily visible deficiencies, including leakage, an exposed power cord, or excessive corrosion. Garbage disposals are inspected for basic operation only and are not evaluated for grinding performance. No significant deficiencies were identified unless otherwise noted within this section.
15.9 Microwave
Microwave if Applicable : Not Present
15.10 Kitchen Ventilation Method
Ventilation Method if Applicable : Not Present
15.11 General Appliances
Info and LMT's. Appliances are checked for general functionality by turning them on for a short period of time using basic operating modes. Thermostats, timers, clocks, self-cleaning features and other specialized functions are not tested during this inspection. Appliances are not inspected for cosmetic flaws, performance or the ability/accuracy of heating, cooling, etc. They are not inspected to ascertain whether the proper racks and/or accessories are present or in working order. Laundry appliances (and other portable appliances) are not moved and are outside the scope of this inspection; any comments are included for information purposes only. Water supply valves are not operated for liability reasons. It is further recommended that appliances be operated once again during the final walk through inspection prior to closing. Finally, product recalls and consumer product safety alerts occur almost daily. To best address your specific concerns, visit www.cpsc.gov or www.recalls.gov. Items, brand names, and model numbers will be required for proper identification.You may also find some general information or listed recalls on appliances by visiting the following link: https://www.building-center.org/
Info and LMT's. Except for the microwave, kitchen appliances were tested during inspection today. The typical design life of appliances can range from 4-20 years. Some appliances such as an older electric range are simple and tend to last longer than more complex appliances such as dishwashers and refrigerators or modern appliances with circuit boards. It is impossible to predict the useful remaining life of an appliance. I ran appliances during inspection. Any defects noted will be listed in this report.
Ch. 16 Laundry Facilities
16.1
Per the Standards of Practice, the inspector will examine and report on the condition of the exposed plumbing, the presence of a 240-volt receptacle, GFCI receptacles, dryer vent condition, and termination, as well as the walls, floors, ceilings, doors, cabinets, counters, and windows, if applicable.
The inspector is not required to: Inspect or move washers and dryers, operate water valves where the flow end of the faucet is connected to an appliance, or Inspect the plumbing for proper sizing, design, or use of proper materials.
16.2 Laundry Overview Photos
16.3 Washer
Washer: Not Present
Info and LMT's. Washer Drain Line – Not In Use / Not Verified
No washing machine was present at the time of inspection. As a result, the washer drain line was not operated or tested, and its routing, connections, and ability to properly handle discharge could not be confirmed. Inquire with the seller regarding prior use, known issues, and the condition of the washer drain line, and verify proper drainage and leak-free performance once a washer is installed.
16.4 Dryer
Dryer: Not Present
Power Source: Electric
Exhaust Duct: Ducted to Exterior
Info and LMT's. Dryer Exhaust Vent (Limited Visibility)
Portions of the dryer exhaust vent are concealed within wall and/or ceiling cavities and were not fully visible. As a result, the routing, support, connections, termination, and materials used in concealed sections could not be confirmed. If improper or non-recommended materials are present in these concealed areas—such as foil or Mylar flex duct, plastic ducting, thin vinyl ducting, or similar non-metal materials—they should be removed and replaced with smooth-wall or listed corrugated metal ducting in line with modern safety and manufacturer standards.
Concealed dryer vent conditions are a common source of airflow restriction and lint accumulation, which can increase fire risk. Verification and correction, if needed, should be performed by a qualified contractor familiar with proper dryer venting practices.
No Appliances Installed
No appliances have been installed for the laundry room at the time of inspection. When you install your dryer, be sure to check that it is venting outdoors - this is difficult to confirm during inspection when no appliances are present.
Dryer Vent Cleaning Note
Periodic cleaning of the dryer exhaust duct is recommended as part of normal home maintenance. Lint accumulation within the duct can restrict airflow, reduce dryer performance, and increase the potential for overheating or fire.
The maintenance history of the dryer exhaust duct could not be determined during the inspection. Consider cleaning the duct after taking possession if recent professional cleaning cannot be confirmed.
16. 5 Laundry Ventilation
Type: Not Present
Laundry Room Ventilation
No dedicated mechanical exhaust ventilation was present in the laundry room. This configuration is common in some older homes and no related moisture concerns were observed at the time of the inspection.
Normal ventilation and humidity control should be maintained during laundry use. Mechanical ventilation may be considered as a future improvement if desired.
Ch. 17 Bathroom Finishes
17.1
Per the Standards of Practice, the inspector will examine and report the condition of the: sinks, showers, tubs, enclosures, toilets, exposed plumbing, and the presence of leaks from plumbing, fixtures, and/or faucets. As well as the walls, floors, ceilings, a representative number of windows and doors, heating/cooling source, ventilation, and presence of GFCI protection, if applicable. GFCI protection in bathrooms was not required in homes built prior to 1975, but upgrading is recommended for safety.
The home inspector is not required to: Operate any valve except water closet flush valves, fixture faucets, and hose faucets; or Inspect the system for proper sizing, design, or use of proper materials.
17.2 Bathroom Overview Photos
General Pictures
General Bathroom Pictures
17.3 Sinks and Cabinets
The representative visible sink components were inspected by operating the faucets, shutoff valves, and other accessible controls, where possible, to evaluate their basic function and identify any readily visible deficiencies. Water was run through the drain system to evaluate functional drainage and check for visible leakage at the fixture, supply connections, drain assembly, and accessible areas below. No significant deficiencies were identified unless otherwise noted within this section.
The visible sink plumbing was inspected by running water through the drain system for over one minute to evaluate drainage and check for readily visible leakage at the drain assembly, supply connections, and accessible areas below the fixture. The visible plumbing was also evaluated for other readily apparent deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Note:
- Thermal images taken during the inspection did not reveal any signs of active leaks at the time of inspection.
17.4 Toilets
The representative visible toilets were inspected by flushing them to evaluate their basic function and identify any readily visible deficiencies. The fixtures were also checked for visible leakage at the tank, supply connections, and base. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Toilets are not assessed for their attachment to the closet flange or anchor bolts during the inspection. This is because manipulating or pushing on a toilet can compromise the wax seal, potentially leading to leaks. Therefore, the securing of toilets is not included in this inspection.
17.5 Bathtub / Shower / Bathtub Walls and Enclosures
The representative visible shower and tub components were inspected by operating the fixtures, where possible, to evaluate their basic function, water flow, drainage, and identify any readily visible deficiencies. Water was run through the fixtures for several minutes while accessible areas, including the enclosure, walls, door, drain assembly, and areas below (where accessible), were checked for visible leakage or conditions that could permit water intrusion. Occupant use and long-term water exposure cannot be fully replicated during a visual home inspection. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Water was allowed to flow through the drains of tubs and showers for an extended duration, followed by an inspection of the areas beneath these drains (if applicable) using thermal imaging to detect any signs of leaks. No leaks were detected during the inspection unless specifically mentioned in this report.
It's important to note that the effects of weight applied to these drains cannot be replicated during the inspection. When individuals shower or bathe, the weight can exert pressure on gaskets or joints in the drain pipes, potentially leading to leaks. This risk may be heightened in homes that have been unoccupied for an extended period. Therefore, any leaks occurring from these areas after the inspection are not covered.
Info and LMT's. Tub and sink overflows are not assessed for functionality during testing, as there is a high probability that the gaskets may leak. Therefore, it is advisable to be cautious when filling tubs to prevent water from entering the overflow. While these overflows typically help drain away excess water, some degree of leakage should be expected. To address this issue, it is recommended to have a licensed plumber inspect the gaskets and perform any necessary repairs. It should be assumed that these overflows may not be completely watertight.
Unable to verify water proofing materials.
Bathtub and shower floors, as well as walls above built-in tubs with showerheads, must be made of smooth, corrosion-resistant, and nonabsorbent waterproof materials. Walls must extend at least 6 feet (1829 mm) above the room floor or 70 inches (1778 mm) above the drain, whichever is greater, forming a watertight seal with the tub or shower floor.
For field-constructed enclosures, IBC (Sections 2509.2 and 1210.3)regulate materials. Tile backings must be glass mat water-resistant panels, non-asbestos fiber-cement, or fiber-mat-reinforced cement sheets. Above the required height, water-resistant gypsum board may be used. When used within tub or shower compartments (including ceilings), vapor barriers are prohibited. Ceiling installation requires 1/2-inch (12.7 mm) board with 12-inch (305 mm) spacing or 5/8-inch (15.9 mm) board with 16-inch (406 mm) spacing.
For proper waterproofing installation, see this link Water Proofing Shower Walls
Missing / Deteriorated Caulking at Tub or Shower Base
The sealant at the tub or shower base is incomplete or deteriorated. This condition can allow water intrusion into surrounding materials and may contribute to moisture-related deterioration or microbial growth over time.
Recommendations:
Request that the builder or appropriate contractor properly seal the flooring-to-tub transition with a compatible flexible sealant. Work should provide a continuous moisture-resistant joint and include review of similar wet-area transitions for incomplete sealing.
17.6 Bathroom Ventilation
Type: Bath fan
The representative visible bathroom exhaust fan(s) were inspected by operating normal controls to evaluate their basic function and identify any readily visible deficiencies. The apparent discharge method, where visible, was also considered. No significant deficiencies were identified unless otherwise noted within this section.
Bath Fan Note. The lifespan of a bathroom fan, also known as an exhaust fan, can vary depending on several factors, including the quality of the fan, the frequency of use, and the level of maintenance and care. In general, a well-maintained bathroom fan can last anywhere from 10 to 15 years, although some fans may last longer or shorter depending on their specific features and usage.
17.8 General Bathroom Finishes Condition
Info and LMT's. Bathroom Plumbing and Moisture Note
Plumbing fixtures in the bathrooms were operated at the time of inspection. Representative areas around toilets, tubs, showers, and accessible tile enclosures were checked for signs of active leakage, moisture-related concerns, loose finishes, or deteriorated tile conditions using normal inspection methods, including limited moisture meter testing and sounding of accessible surfaces where appropriate.
Bathtub overflow drains are not filled or intentionally tested during a home inspection, as doing so may increase the risk of leakage or damage around finished surfaces. Homeowners should avoid directing water into overflow openings and monitor tubs while filling, particularly after moving into the home. Overflow gaskets and concealed plumbing seals can deteriorate over time and may leak intermittently even when no visible concerns are present at the time of inspection.
Plumbing systems in vacant homes may present additional uncertainty, as limited fixture operation during an inspection does not fully replicate normal daily use conditions. Continued monitoring of plumbing fixtures, drains, and surrounding finishes is recommended after occupancy. Any visible deficiencies identified at the time of inspection are included elsewhere within this report.
Ch. 18 Attic, Roof Structure and Ventilation
18.1
Per the Standards of Practice, the inspector will examine: the attic area and report on the condition of the access opening (including location), insulation type (and current depth), ducts, visible electrical components, exhaust terminations, plumbing components, and ventilation if applicable.
The inspector is not required to: move or disturb insulation, report on the adequacy of current ventilation, or Calculate the strength, adequacy, or efficiency of any system or component, including framing. Enter any attic that may damage the property or its components or be dangerous to or adversely affect the health or safety of the home inspector or other persons. Therefore, I do not attempt to enter attics with less than 36" of headroom, where insulation obscures the ceiling joists, or where ducts block access. In these cases, I will evaluate from the access opening as best I can.
18.2 Attic Overview Photos
Info and LMT's. It is recommended to inspect all attic spaces at least twice annually to ensure that ventilation openings remain unobstructed and to prevent the development of mold. While there may be minimal or no visible evidence of organic growth during the inspection, mold can proliferate rapidly under favorable conditions. Organic growth poses potential hazards and can spread when moisture accumulates in the attic and is not properly vented to the exterior. Any areas of concern should be examined by a qualified contractor for analysis and appropriate removal measures.
Info and LMT's. Every effort is made to access and navigate all attics safely and thoroughly. Details regarding the inspection method used, including the approximate percentages of the attic that were both physically and visually accessible, will be provided, along with any safety concerns or obstacles that may have limited the inspection.
The method of inspection is determined solely by the inspector and is influenced by various factors, including accessibility, clearance, insulation levels, stored items, temperature, and more. It's important to note that the inspection is confined to visible areas only, and any sections that were not visually accessible are not included in the assessment.
It's essential to recognize that hidden damage may exist, as no attic can be entirely evaluated due to physical and visible obstructions such as insulation, which is not disturbed during the inspection for visual access to items.
18.3 Attic Access
Hatch Location: Garage
Method Of Inspection: Walked
Percentage of Attic that could be Safely Traversed: 70%
The attic access(es) were inspected by evaluating their location, type, and general condition while identifying any readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
18.4 Roof Framing and Sheathing
Rafters: Truss
Sheathing: Plywood
A representative sample of the visible portions of the roof structure were inspected for readily visible signs of moisture intrusion, damage, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
18.5 Fire Separation
Info and LMT's. Attic Visibility. Some areas of the attic were obstructed by insulation or other materials, which prevented a full view of vent penetrations and potential fire-stopping. The inspection is therefore limited to visible areas only.
18.6 Attic Insulation
Attic Insulation Type: Fiberglass
Insulation Depth: 11, 12
Approximate Insulation R-Value on Attic Floor: Improve to Modern Standard
Approximate Insulation R-Value on Attic Ceiling: Not needed
Approximate Insulation R-Value on Attic Walls: Not needed
Representative areas of the visible attic insulation were inspected to identify the apparent insulation type, estimate the approximate depth, and identify any readily visible deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Attic Insulation – Improvement Recommended
The attic insulation level does not appear consistent with modern energy-efficiency recommendations commonly used in this climate region. Modern standards generally favor higher insulation levels combined with improved attic air sealing to help reduce thermal loss and improve overall building performance.
Recommendations:
The attic insulation appeared lower than typically expected for modern new construction. Have the builder verify the installed insulation specifications and energy-code compliance and correct any deficiencies as needed under applicable warranty coverage.
18.7 Attic and Roof Cavity Ventilation
Attic Ventilation Method: Soffit vents, Ridge vents
Roof Ventilation Description
Attic and roof cavity ventilation is a frequently misunderstood element of residential construction. All roof cavities are required to have ventilation. The general default standard is 1 to 150 of the attic area and ideally, this comes from at least 60% lower roof cavity ventilation and 40% upper, but this is a wild over-simplifications of the subject. As a good guiding principle the most important elements for healthy attic spaces, which are traditionally insulated and ventilated are:
Make sure the ceiling between the living space and the attic is airtight
Ventilate consistently across the whole lower part of the roof cavity with low, intake soffit venting
Upper roof cavity venting is less important and if over-installed can exacerbate air migration into the attic from the living space.
Avoid power ventilators which can depressurize the attic and exacerbate air migration from the house into the attic.
For more information, please see: Link
Ch. 19 Foundation, Structure and Basement
19.1
Per the Standards of practice, the inspector will examine and report on the condition of the foundation walls, the framing (including probing of any framing that looks to have damage/deterioration), columns/piers, and insulation if applicable.
The inspector is not required to: enter any area that could be considered a safety hazard to the inspector; report on the adequacy of structural components; or report on spacing, span, or size of structural components. Ductwork, framing, plumbing, and insulation may block the visual accessibility of some areas. The inspection is limited to the conditions on the inspection day; I inspect several items looking for indications that moisture has infiltrated the foundation area. But, I cannot guarantee that water will not infiltrate the area at a future time due to conditions unforeseen at the time of inspection.
19.2 Foundation
Building Configuration: Basement
Foundation Description: Poured concrete
Estimated Percentage of Visible Foundation: 60%
Evidence of Seismic Protection or Foundation Reinforcements: Not visible
A representative number of the visible portions of the foundation walls were inspected to evaluate their general condition and identify any readily visible signs of cracking, moisture intrusion, damage, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Info and LMT's. Foundation & Basement Inspection Scope
A representative sample of the visible and readily accessible foundation, structural, and below-grade components was inspected for significant deficiencies, including signs of structural movement, damage, and moisture intrusion. Finished walls, ceilings, floors, stored belongings, insulation, and other concealed conditions limited visibility of many structural components, including portions of the foundation, framing, subflooring, and the foundation footing, which is typically concealed below grade and was not visible.
No evidence of active water intrusion or moisture-related concerns was identified in the visible areas at the time of the inspection unless otherwise noted within this section. Home inspections provide a snapshot of conditions present on the day of the inspection and cannot predict or guarantee future water intrusion, particularly during periods of heavy rainfall, seasonal groundwater changes, or other changing site conditions. Engineering analysis, structural calculations, and determination of structural design adequacy are beyond the scope of a standard home inspection.
The inspection of the poured concrete foundation is non-invasive and visual in nature. While we assess visible areas for cracks, moisture, and apparent defects, underlying conditions, such as hidden cracks or structural concerns within the concrete, may not be fully determined without destructive testing or specialized equipment
19.3 Floor, Wall and Ceiling Framing
Wall Framing: Not Visble
Wall Sheathing: Not visible
Floor Framing: Partly visible, 2x10
Sub-Floor Material: Partly visible, Plywood
Ceiling Framing: Not visible
Floor, Wall and Ceiling Framing Visual Obstructions:: HVAC Ductwork
A representative portion of the visible and accessible structural components were inspected to evaluate their general condition and identify any readily visible damage or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
Floor Joist Notched-OK
The floor joists have been notched to the floor framing system. The notching looks to be less than 1/3 of the joist depth and notches are allowed on the ends of joists. This also seems to have performed well to date. I do not see anything worth correcting at this time, however it should be monitored over time if correction may be needed.
19.4 Basement Overview Photos
Description: Full
Info and LMT's. A typical home inspection of a basement is primarily visual in nature due to practical limitations. Home inspectors visually examine the basement to evaluate its overall condition, identify visible issues such as water damage, structural concerns, or safety hazards. They rely on observable elements without employing invasive techniques, as accessing hidden areas may necessitate destructive actions.
Although a visual inspection offers valuable insights, it's crucial to acknowledge its inherent limitations. Considering additional assessments may be necessary to gain a comprehensive understanding of the basement's condition.
Egress Window Note
The basement lacks an egress window. In Ohio, egress windows are not required in basements unless there is a sleeping room present. Since no bedroom is located in this basement area, the absence of an egress window complies with current building codes.
For future reference, should a basement bedroom be added, an egress window would then be required to meet safety standards.
19.5 Slabs and Concrete Floors
Slab Type: Concrete
The visible portions of the concrete slab were inspected for readily visible signs of significant cracking, damage, or other deficiencies. No significant deficiencies were identified unless otherwise noted within this section.
19.6 Basement Moisture
Moisture Present if Applicable : None noted
No leaks were observed during the course of the inspection. Although no active moisture penetration was noted, it is advised that you always monitor this area and as good practice consider any basement as wet until experience proves it dry.
Ch. 20 Crawl Space
20.1 General Crawl Space
Crawl Space: Present
20.2 Crawl Space Access
Method of Inspection: Crawled
Percentage of Roof that could be Safely Traversed: 80%
Info and LMT's. While the crawl space was inspected, it's important to understand the limitations: Despite efforts to examine the entire space, the inspection is visually oriented and can be challenging due to potential restrictions caused by pipes, ducts, sub-floor insulation, and limited clearances. Therefore, only accessible and safe areas are inspected during this assessment.
20.3 Vapor Barrier
Vapor Barrier Material: Plastic on earth
20.4 Crawl Space Ventilation
Ventilation Method: Vents to basement
20.5 Posts and Footings
If Applicable: None needed
20.6 Insulation
Insulation Type: Fiberglass
Info and LMT's. Visible insulation in the crawl space was inspected, including batts between floor joists and insulation applied to foundation walls where accessible. Concealed areas behind ductwork, piping, or stored items were not visible.
20.7 Moisture Conditions
Moisture if Applicable: No water was visible or present at the time of inspection
The crawl space was dry at the time of inspection. It is always good practice to monitor crawl spaces to see how they perform a regarding drainage.
Ch. 21 Cracking, Settlement and Movement
21.1
Cracking, Settlement and Movement if Applicable: Note
Exterior Hardscapes & Flatwork: None Present on the Day of Inspection
Exterior Walls: None Present on the Day of Inspection
Interior Area(s): None Present on the Day of Inspection
Foundation Walls: None Present on the Day of Inspection
Slabs: None Present on the Day of Inspection
This section of the report will address concerns and deficiencies related to cracking, settlement, or movement. The inspection covered visible areas of the exterior, interior, and foundation, with particular attention to identifying cracks and signs of movement or settlement. The assessment of cracking acceptability depends on the client's preferences and exceeds the scope of a standard home inspection and any associated repairs are at the discretion of the client. No visible indications of these conditions were observed during the inspection, unless otherwise specified in this report.
Ch. 22 Thermal Imaging
22.1 Thermal Images
An infrared camera was used selectively to examine specific areas of concern or to help validate suspected issues. Its use should not be interpreted as a comprehensive thermal survey of the entire structure. Deployment of the infrared camera was at my discretion to provide additional insight, and its application goes beyond the standard scope of a home inspection.
Temperature readings shown on thermal images are provided as a courtesy and should not be solely relied upon. They are intended as qualitative indicators rather than precise measurements, and actual temperatures may vary by +/- 2% or more. Some readings reflect surface temperatures only, and obtaining air or internal temperature measurements is beyond the scope of this inspection.
Ch. 23 Environmental Information
23.1 Moisture, Water Penetration and Active Leaks
I inspected all visible and accessible areas for evidence of moisture intrusion or conditions that could contribute to moisture-related issues. At the time of inspection, no active moisture or leaks were observed, and all areas appeared to be performing as intended. These observations are limited to the conditions present at the time of inspection. Any future signs of moisture, damage, or related concerns may require further assessment by qualified professionals.
23.2 Mold and Bio-Growth
Please note that mold testing and indoor air quality assessments are beyond the scope of this inspection. If there are concerns about bio-growth or indoor air quality, I recommend evaluation by a qualified specialist. In general, localized issues can often be addressed by removing or sealing the affected area. Best practices for controlling bio-growth focus on diagnosing and repairing water problems. Where water issues are chronic, bio-growth can be more complex and costly to remediate. Where water problems are isolated, mold-related repairs tend to be limited in scope and less complex.
23.3 Pest/Insects/Wildlife Concerns: WDI / Termite Information and Exclusions
Environmental Hazards and Pest/Wood-Destroying Insect (WDI) Disclaimer:
As a home inspector, I do not assess or test for environmental hazards or pest infestations. Specifically, this inspection does not include:
- The presence of mold, mildew, fungus, or airborne contaminants.
- The identification of rodents, animals, bats, guano, or insects, including wood-destroying insects (WDIs).
- Air quality assessments.
- The presence of hazardous materials such as asbestos, lead-based paint, or other environmental risks.
- Hazardous waste conditions or contamination.
Pest & Wood-Destroying Insect (WDI) Concerns:
This inspection does not include an evaluation for the presence of pests, including wood-destroying insects such as termites, carpenter ants, or powderpost beetles. Nothing related to pests or WDI activity was visible on the day of inspection unless otherwise noted in this report. Any such mentions included in the report are based solely on a visual assessment and are strictly provided as recommendations, not a formal pest inspection.
If concerns regarding potential pest activity exist, I strongly recommend:
- Consulting a licensed pest control or WDI specialist to inspect and assess the entire building structure for pest activity or damage.
- Understanding that any informal mention of pest-related issues during this inspection is provided as a courtesy only and should not be interpreted as a formal pest inspection. A professional evaluation is still necessary.
For all environmental hazards or wood-destroying insect concerns, please seek a qualified specialist to perform a dedicated inspection.
Ch. 24 Checking Out Procedure
24.1 Check Out List
Heating and Cooling: Restored to Pre-inspection temperatures
Oven: Not Applicable
Appliances: Not Applicable
GFCI Reset: Reset
Lights: Off
Keys and Lockbox: Locked door upon departure
All accessible GFCI outlets were tested during the inspection. Each outlet was reset to its operational state before leaving the property.
24.2 Verbal Consultation
In person
24.3 One Year Follow Up
Once you approach the one-year mark of the purchase of your new home. A one-year inspection is a proactive measure to ensure the continued well-being of your property and identify any potential issues that may have arisen since the initial assessment.
If you wish to have this completed, please contact me for details at: 1-614-296-3721 or schedule online at olonzoinspections.com
Summary
Moderate Repair And Maintenance Items
- C4ESDW-7 Ch. 4 Exterior Siding, Doors and Windows:
Inconsistent Wall Cladding Flashing
Deficiencies were noted in the flashing installation at wall cladding transitions. Improper water-shedding details increase the likelihood of concealed moisture intrusion and may contribute to deterioration of adjacent building materials if left uncorrected.
Recommendations:
If the home is newer construction or may still be covered by a builder warranty, consultation with the builder is recommended. The builder may wish to verify that flashing and water-management details were installed in accordance with the original design and manufacturer requirements.
Key Points:
- Flashing helps direct water away from vulnerable wall transitions
- Long-term exposure may contribute to deterioration of sheathing, framing, and finish materials
Note:
Location(s)Exterior - FrontPorch - C4ESDW-8 Ch. 4 Exterior Siding, Doors and Windows:
Exposed Fasteners at Exterior Siding / Trim
Exposed or inadequately sealed fasteners were noted at portions of the exterior siding and/or trim. These locations can allow moisture intrusion and may contribute to staining, deterioration, or premature failure of surrounding materials.
Recommendations:
Have the builder correct exposed fasteners at the affected siding and trim in accordance with manufacturer installation requirements. Corrective work should include properly sealing or otherwise addressing affected fasteners and reviewing adjacent exterior finishes for similar installation conditions.
Location(s)Exterior - FrontSiding / CladdingTrim / Fascia / Soffits/Eaves - C6RCG-10 Ch. 6 Roof, Chimney and Gutters:
Roof Covering – Localized Damage Present
Damage is present to portions of the roof covering. The affected materials may be more vulnerable to water penetration and weather-related deterioration, particularly during severe weather events.
Recommendations:
Have the builder or qualified roofing contractor replace damaged shingles and review adjacent roof areas for similar damage. Repairs should use compatible materials and be completed in accordance with the roofing manufacturer's installation requirements to maintain proper weather resistance and applicable warranty coverage.
Key Points:
- Localized damage may allow moisture intrusion.
Location(s)Roof - Front Slope - C6RCG-11 Ch. 6 Roof, Chimney and Gutters:
Shingle(s) Not Properly Adhered
One or more roof shingles were observed that had not properly adhered or sealed to the underlying shingles. Unsealed shingles are more susceptible to wind uplift, displacement, and moisture intrusion and may affect the long-term performance of the roof covering.
Recommendations:
Have the builder or qualified roofing contractor correct shingles that have not properly adhered or sealed. Work should be completed in accordance with the roofing manufacturer's installation requirements and should include reviewing adjacent roof areas for similar installation conditions. Damaged shingles should be replaced as needed to maintain proper weather resistance and applicable warranty coverage.
Key Points:
- Unsealed shingles are more susceptible to wind uplift and displacement.
Location(s)Roof - Front Slope - C6RCG-15 Ch. 6 Roof, Chimney and Gutters:
Missing Drip Edge Flashing
Drip edge flashing is missing at portions of the roof edges. Drip edge helps direct water away from the roof decking and fascia while supporting proper water management at the roof perimeter. Its absence may allow moisture to reach underlying wood components, contributing to deterioration of the roof edge, fascia, soffit, or roof sheathing over time.
Recommendations:
Have a qualified roofing contractor install drip edge flashing where missing. The scope of work may reasonably include lifting and reinstalling roofing materials as needed, installing compatible drip edge flashing, verifying proper integration with the underlayment and gutter system, and assessing adjacent roof edge sections where similar conditions may exist.
Key Points:
- Drip edge helps direct water away from the roof edge and into the gutter system.
- Missing flashing can allow moisture to affect fascia, soffits, and roof sheathing.
Location(s)Roof - GeneralRoof - Front SlopeRoof - Rear SlopeRoof - Left SlopeRoof - Right SlopeFlashing / Penetrations - C1EDFW-5 Ch. 10 Electric Distribution and Finish Wiring:
Inoperative Outlet
One or more electrical outlets were inoperative at the time of inspection without any clearly identified switch control or GFCI protection. This condition raises concern for possible wiring defects, failed connections, or circuit-related issues that may impact electrical safety and system reliability.
Recommendations:
Have the builder or qualified electrician correct the inoperative receptacle and verify proper operation. Work should include determining the cause of the condition and reviewing associated electrical components for proper installation and function as needed.
Note:
- Electrical work appeared to remain in progress, and the condition may be related to incomplete installation, connections, or circuit activation. Final operation should be verified by the builder upon completion of the electrical work.
Location(s)Dining RoomLaundry Room - C1HCFV-14 Ch. 11 Heating, Cooling, Fireplaces and Ventilation:
Furnace Inoperative – Operation Not Verified
The furnace did not operate when tested. It could not be determined whether the gas supply was active or whether the condition was related to incomplete construction, system setup, or an equipment-related issue. As a result, proper furnace operation could not be verified during the inspection.
Recommendations:
Have the builder and/or qualified HVAC contractor verify that the gas supply is active and place the furnace into normal operation. The system should be fully tested and any deficiencies corrected prior to occupancy or closing.
- C1HCFV-15 Ch. 11 Heating, Cooling, Fireplaces and Ventilation:
Construction Dust at Furnace
Drywall and/or construction dust was observed within portions of the furnace. Construction debris can accumulate on HVAC components, restrict airflow, and affect system performance if not properly cleaned.
Recommendations:
Have the builder or qualified HVAC contractor clean and service the furnace and accessible system components as needed. Replace the HVAC filter and verify the system is clean and operating properly prior to occupancy.
- C1P-4 Ch. 12 Plumbing:
High Water Pressure Noted
The plumbing system appears subject to elevated water pressure conditions. Excessive pressure can increase stress on fixtures, valves, piping connections, and water-using appliances, potentially contributing to accelerated wear or plumbing failures over time.
Recommendations:
I would have the builder improve the plumbing pressure regulation as recommended. Improvements may include adjusting or installing pressure-reducing equipment, verifying system operating pressure, and reviewing related plumbing fixtures and appliances to help support reliable long-term performance consistent with modern plumbing practices.
Key Points:
- Water pressure above 80 psi is generally considered high and can put stress on pipes, fixtures, and appliances.
- High pressure may cause leaks, burst pipes, or premature wear on plumbing components.
Note:
- Water pressure was measured at a hose bib, which provides a general reading but may not be as accurate as a pressure reading taken from the washing machine supply lines
Items Recommended For Improvement Or Maintenance
- C3G-11 Ch. 3 Grounds:
Window Well Drainage
The window well lacks a visible drainage system or adequate water-management provisions. Conditions like this can reduce the ability of the well to properly disperse water and may contribute to moisture intrusion or deterioration near basement openings.
Recommendations:
If the home is newer construction or may still fall within a builder warranty period, consultation with the builder is recommended. Improvements or corrective work may include addressing drainage, grading, or installation-related conditions contributing to water accumulation around the window well area.
Key Points:
- Drainage improvements may help support long-term foundation and basement performance
- C3G-12 Ch. 3 Grounds:
Missing Window Well Covers
One or more window wells lack protective covers, increasing the likelihood of debris buildup and water accumulation. Conditions like this can reduce drainage effectiveness and may contribute to moisture intrusion or deterioration near basement window openings.
Recommendations:
Consultation with the builder is recommended. Improvements may include installation of appropriate window well covers and addressing related drainage or grading conditions contributing to moisture accumulation around basement openings.
- C4ESDW-9 Ch. 4 Exterior Siding, Doors and Windows:
Inadequate Exterior Caulking
Deteriorated exterior sealant is present at multiple joints and transitions. Open gaps or failed caulking may allow increased moisture intrusion into surrounding assemblies, which can contribute to material deterioration and ongoing maintenance concerns if not addressed.
Recommendations:
I would consult with the builder. Improvements may include correcting incomplete or deteriorated exterior sealant installations, addressing affected joints and material transitions, and reviewing similar exterior areas where comparable installation or finishing conditions may exist to help support proper water management and long-term exterior performance consistent with modern construction practices.
Key Points:
- Exterior sealant requires periodic maintenance and replacement as part of normal upkeep
Location(s)Exterior - Right Side - C6RCG-16 Ch. 6 Roof, Chimney and Gutters:
Missing Kick-Out / Re-Direct Flashing
Missing kick-out flashing is present at portions of the roof-to-wall intersections. Conditions like this may allow roof runoff to concentrate against exterior wall surfaces and can contribute to concealed moisture intrusion or deterioration of siding and underlying materials over time.
Recommendations:
If the home is newer construction or may still fall within a builder warranty period, consultation with the builder is recommended. Corrective work may include installation of missing kick-out flashing and review of roof-to-wall water-management details to confirm the assembly performs as intended.
Key Points:
- Kick-out flashing helps divert roof runoff away from exterior walls
- C1EDFW-10 Ch. 10 Electric Distribution and Finish Wiring:
Loose Light Fixture
The light fixture is loose and not securely fastened at its mounting location. This condition can allow movement at the fixture, which may affect electrical connections and presents a potential safety concern if the fixture becomes unstable over time.
Recommendations:
This would be a reasonable item to discuss with the builder. The fixture appears loose at the mounting location and may simply require adjustment, tightening, or improved support. Having the builder correct the installation and review similar fixtures may help ensure the lighting components are securely mounted and performing as intended.
Location(s)Exterior - Front - C1HCFV-17 Ch. 11 Heating, Cooling, Fireplaces and Ventilation:
HVAC Air Filter – Dirty
The HVAC air filter is heavily soiled, restricting normal airflow through the system. Reduced airflow may affect comfort, efficiency, and place unnecessary stress on heating and cooling components if not addressed.
Recommendations:
I would recommend the builder or qualified HVAC contractor replace the dirty air filter and verify proper airflow and system operation. Where construction dust or debris is present, accessible HVAC components should also be reviewed and cleaned as needed prior to occupancy.
Key Points:
- Dirty air filters reduce airflow and HVAC efficiency.
- C1HCFV-19 Ch. 11 Heating, Cooling, Fireplaces and Ventilation:
High-Efficiency Furnace PVC Vent Termination
The furnace PVC vent termination may not fully reflect modern installation and protection practices intended to help reduce the likelihood of debris intrusion, pest entry, snow blockage, or airflow restriction at high-efficiency appliance vent systems.
Recommendations:
This appears to be more of an installation-detail concern than a current performance failure. If the property is newer construction, having the builder review the vent termination and make any recommended improvements may help support safer and more consistent airflow at the furnace venting system.
- C1HCFV-21 Ch. 11 Heating, Cooling, Fireplaces and Ventilation:
Missing or Damaged Heat Register Covers
One or more heat register covers are missing or damaged. This can leave duct openings exposed, affect airflow distribution, and allow debris or objects to enter the ductwork.
Recommendations:
Have the builder or qualified HVAC contractor install or replace missing or damaged register covers prior to occupancy. Covers should be properly sized, securely installed, and free of damage. Review remaining supply and return openings for similar incomplete or damaged components.
Location(s)First Floor - C1P-9 Ch. 12 Plumbing:
Inadequate Pipe Supply Pipe Support
Portions of the plumbing supply system appear improperly supported or insufficiently secured. Excessive movement or sagging can place ongoing stress on pipe connections and may contribute to leakage, noise, or reduced long-term plumbing performance.
Recommendations:
The builder should improve the affected piping support installation as recommended. Improvements may include adding or adjusting pipe supports, improving fastening methods, and reviewing similar accessible plumbing areas to help support reliable long-term plumbing performance consistent with modern installation practices.
Key Points:
- Unsupported piping can shift and place stress on fittings and joints
- Excessive movement may contribute to leaks or premature plumbing wear
Notes:
- PEX pipe should have supports every 32 inches.
- C1P-25 Ch. 12 Plumbing:
Outdoor Faucet-Non-Operational
The exterior hose bib does not appear operational. Conditions like this may indicate fixture failure, supply valve concerns, freeze-related damage, or related plumbing issues that could affect long-term performance or result in leakage if left uncorrected.
Recommendations:
I would encourage the builder to restore proper operation of the exterior faucet as recommended. Improvements may include repair or replacement of the fixture, confirmation of proper shutoff and supply piping operation, and review of nearby plumbing connections to help support reliable long-term performance consistent with modern installation practices.
Key Points:
- Non-operational hose bibs limit normal exterior water access
- Freeze-related damage or shutoff issues are common causes of failure
- Early repairs may help prevent future leakage or plumbing deterioration
Note:
- The exterior hose bibs may have also been winterized at the time of inspection and could not be tested. Inquire with the seller to see if they are generally operable.
- C1AP-5 Ch. 13 Additional Plumbing:
Missing Basement Floor Drain Cover
Modern plumbing installations generally include secured or fitted floor drain covers intended to help reduce debris intrusion and improve drainage system protection. The visible condition does not appear consistent with these common plumbing practices.
Recommendations:
I would see if the builder could improve the floor drain assembly as recommended. Improvements may include installing a proper drain cover, confirming trap functionality, and reviewing similar drainage components to help support proper plumbing performance consistent with modern installation practices.
Key Points:
- Proper covers help improve drainage protection and sanitation
- C1ILAB-5 Ch. 14 Interior Living Area(s) and Bedrooms:
Interior Trim - Incomplete
Interior trim is missing in one or more areas, leaving exposed gaps or unfinished transitions between materials. In addition to cosmetic concerns, missing trim may reduce protection of adjacent finishes and can allow gaps to remain exposed.
Recommendations:
Missing or incomplete trim should be installed and finished by the builder or appropriate contractor prior to occupancy. Work should include completing affected areas with compatible materials and reviewing nearby finishes for similar incomplete conditions.
Location(s)Primary BathroomFamily Bathroom - C1ILAB-9 Ch. 14 Interior Living Area(s) and Bedrooms:
Top of Door Not Finished/Sealed
One or more door tops are missing protective finish or sealant. Continued exposure to humidity or moisture may increase the likelihood of swelling, finish damage, or reduced door performance over time.
Recommendations:
Consultation with the builder is recommended. Improvements may include sealing unfinished door edges, correcting incomplete finish work, and addressing similar workmanship-related conditions where present.
Note:
- Most doors are shipped without the top edge finishes and finishes are required to be completed on site.
Location(s)First Floor - C1ILAB-10 Ch. 14 Interior Living Area(s) and Bedrooms:
Closet Doors Missing Floor Guides
Closet door floor guides are missing, allowing excessive movement and instability during operation. Conditions like this may increase the likelihood of track damage, hardware wear, door misalignment, or operational failure over time.
Recommendations:
The builder or appropriate contractor should install missing floor guides at affected closet doors and adjust the doors as needed for secure, smooth operation. Nearby closet doors should be reviewed for similar incomplete installation.
Location(s)Entry / FoyerBedroom 2 - C1BF-11 Ch. 17 Bathroom Finishes:
Missing / Deteriorated Caulking at Tub or Shower Base
The sealant at the tub or shower base is incomplete or deteriorated. This condition can allow water intrusion into surrounding materials and may contribute to moisture-related deterioration or microbial growth over time.
Recommendations:
Request that the builder or appropriate contractor properly seal the flooring-to-tub transition with a compatible flexible sealant. Work should provide a continuous moisture-resistant joint and include review of similar wet-area transitions for incomplete sealing.
Location(s)Primary Bathroom - C1ARSV-9 Ch. 18 Attic, Roof Structure and Ventilation:
Attic Insulation – Improvement Recommended
The attic insulation level does not appear consistent with modern energy-efficiency recommendations commonly used in this climate region. Modern standards generally favor higher insulation levels combined with improved attic air sealing to help reduce thermal loss and improve overall building performance.
Recommendations:
The attic insulation appeared lower than typically expected for modern new construction. Have the builder verify the installed insulation specifications and energy-code compliance and correct any deficiencies as needed under applicable warranty coverage.
Conditions Warranting Safety Improvements
- C5DPBES-4 Ch. 5 Decks, Porches, Balconies and Exterior Stairs:
Non-Uniform Stair Riser Heights
Noticeable variations in stair riser height are present. Inconsistent stair geometry can interfere with normal walking rhythm and may create elevated trip and fall concerns, especially with regular use or reduced visibility conditions.
Recommendations:
Have the builder correct uneven stair riser heights to provide consistent stair geometry and reduce the potential for trips and falls. Corrective work should be completed in accordance with applicable requirements and accepted construction practices, with adjacent stairs reviewed for similar inconsistencies.
Key Points:
- Consistent stair geometry helps improve overall safety
- C7G-3 Ch. 7 Garage:
Missing Self-Closing Hinges at Garage-to-Interior Door
The garage-to-interior door does not have self-closing hinges installed. While this may not have been required at the time of original construction in some homes, self-closing operation is considered a valuable modern safety feature intended to improve separation between the garage and living areas.
Recommendations:
I would encourage the builder to improve this condition for safety. Improvements may include installing or adjusting self-closing hardware, confirming the door latches properly, and reviewing related garage separation components to help support safer long-term performance consistent with modern construction practices.
Key Points:
- Self-closing garage doors help limit the spread of smoke and fumes into living areas
Note:
- Requirements and enforcement related to self-closing garage-to-house doors have varied over time depending on the applicable construction standards and local adoption practices. Regardless of the specific standard in place at the time of construction, self-closing hinges are generally considered a beneficial safety feature that may help reduce the unintended movement of smoke, fumes, and fire-related conditions from the garage into the living space if the door is accidentally left open.
- C1EDFW-6 Ch. 10 Electric Distribution and Finish Wiring:
Loose Electrical Receptacle
The receptacle is noticeably loose within the wall assembly. Continued movement may contribute to deteriorated wiring connections, intermittent operation, or increased risk of electrical faults over time.
Recommendations:
This appears to be a relatively minor installation-related item that should be brought to the builder's attention. Corrective work may reasonably include securing the receptacle to the electrical box, repairing or replacing mounting hardware as needed, verifying proper support of the device, and reviewing nearby receptacles where similar installation concerns may be present. Any available warranty coverage or responsibility for corrective work should be verified directly with the builder, electrical contractor, or warranty provider.
Location(s)Family Bathroom - C1EDFW-7 Ch. 10 Electric Distribution and Finish Wiring:
Cover Plates Missing
One or more electrical boxes are missing cover plates, leaving wiring or electrical components exposed. This condition increases the risk of accidental contact and is not consistent with commonly accepted electrical safety practices.
Recommendations:
Have the builder or qualified electrician install missing electrical cover plates and review adjacent electrical devices for similar incomplete items prior to closing or occupancy.
Location(s)Living Room - C1ILAB-13 Ch. 14 Interior Living Area(s) and Bedrooms:
Non-Uniform Stair Riser Heights
Modern stair construction practices generally call for stair risers to remain consistent in height throughout the stairway to help improve safety and usability. The visible stair geometry does not appear fully consistent with those practices.
Recommendations:
Request correction of the inconsistent stair riser heights as part of the builder's final work. The completed staircase should provide reasonably uniform step geometry throughout, with modifications made as needed to address the trip and fall concern and meet applicable requirements.