The Scope and Purpose of This Inspection Report
Purpose of the Commercial Purchase Walkthrough (A Limited Scope Inspection)
This limited scope inspection is a visual survey and a basic performance evaluation of the systems and components of the building exterior, mechanical systems, and a representative sampling of units/rooms. It provides information regarding the general condition of the plumbing, electrical, roofing, exterior, HVAC, and mechanical systems at the time the inspection was conducted. It is important that you carefully read ALL of the information in this report. Feel free to ask the inspector to clarify any items or comments that are unclear.
The inspector IS NOT required to:
- identify all potential hazards;
- turn on decommissioned equipment, systems, or utilities;
- climb over obstacles, move furnishings or stored items;
- prioritize or emphasize the importance of one deficiency over another;
- provide follow-up services to verify that proper repairs have been made;
- Provide commentary on systems that require a specialty designation.
Responsibility of the Client
While items identified as Concern, Repair, Maintenance, or Due Diligence in this inspection report DO NOT obligate any party to make repairs or take other actions, in the event that any further evaluations are needed, it is the responsibility of the client to obtain further evaluations and/or cost estimates from qualified service professionals regarding any items so classified. It is recommended that any further evaluations and/or cost estimates take place as soon as feasibly possible after delivery of the report, to mitigate any potential issues or ongoing damage.
Please Note: Evaluations performed by service professionals in response to items reported as Concern, Repair, Maintenance, or Due Diligence on the report may lead to the discovery of additional deficiencies that were not present, visible, or accessible at the time of the inspection. Any repairs made after the date of the inspection may render information contained in this report obsolete or invalid.
Report Limitations
This report is provided for the sole benefit of the client named and is based on observations made by the named inspector on the date the inspection was performed (indicated above).
ONLY those items specifically noted as being inspected on the report were inspected.
This inspection IS NOT:
- a technically exhaustive inspection of the structure, its systems, or its components and may not reveal all deficiencies;
- an inspection to verify compliance with any building codes;
- an inspection to verify compliance with manufacturer's installation instructions for any system or component and DOES NOT imply insurability or warrantability of the structure or its components.
NOTICE CONCERNING HAZARDOUS CONDITIONS, DEFICIENCIES, AND CONTRACTUAL AGREEMENTS
Conditions may be present in the home that did not violate building codes or common practices in effect when the home was constructed but are considered hazardous by today's standards. Such conditions that were part of the home prior to the adoption of any current codes prohibiting them may not be required to be updated to meet current code requirements. However, if it can be reasonably determined that they are present at the time of the inspection, the potential for injury or property loss from these conditions is significant enough to require inspectors to report them as items of Concern, Repair, Maintenance, or Due Diligence. Examples of such hazardous conditions include:
- malfunctioning, improperly installed, or missing ground fault circuit protection (GFCI) devices and arc-fault (AFCI) devices;
- ordinary glass in locations where modern construction requirements call for safety glass;
- malfunctioning or lack of fire safety features such as smoke alarms, fire-rated doors in certain locations, and functional emergency escape and rescue openings in bedrooms;
- malfunctioning or missing carbon monoxide alarms;
- excessive spacing between balusters on stairways and guard rails;
- improperly installed appliances;
- improperly installed or defective safety devices;
- lack of electrical bonding and grounding; and
- lack of bonding on gas piping, including corrugated stainless steel tubing (CSST).
Please Note: items identified as Concern, Repair, Maintenance, or Due Diligence in an inspection report DO NOT obligate any party to make repairs or take other actions. The decision to correct a hazard or any deficiency identified in an inspection report is left up to the Salish Village HOA, according to their bylaws.
How to Read This Report
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which potentially includes digital photographs, diagrams, descriptions, videos, and links to additional information that do not show up in the summary.
The best way to get the layers of information that are presented in this report is to read your report online, which will allow you to expand your learning about your house. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the property into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin.
Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section and it may simply say “tested,” or “inspected.”
Observation Labels
All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
- Concern:Urgent repair items that should be addressed now to prevent further issues or inherent safety hazards. This category includes items requiring immediate attention to prevent additional damage to the structure, or to eliminate safety hazards.
- Repair:Repair and urgent maintenance items noted during inspection. Please note that some repair items can be quite expensive to correct. Items identified in this category should be dealt with in a timely manner (less than 6 months) or they will likely turn into items of concern.
- Maintenance:These are routine items that are less urgent than repairs, and also don't pose an immediate safety risk. Maintenance items that get ignored WILL turn into items of repair or concern... Maintenance items should be addressed within the next 12-24 months.
- Due Diligence:Observations on items that are outside the scope of a general home inspection and require further investigation on your part to determine the severity and/or urgency of potential issues.
- Monitor:Items that do not currently appear to require action, but should be watched to see if action may be needed in the future.
- Informational:Detailed description of various aspects of the property noted during the inspection. Generally good stuff to know.
- Not Inspected:Refers to limitations and/or exclusions to the home inspection. Items with this designation are not part of the SOP, but may be commented on as a courtesy.
Summary Page
The Summary Page is designed as a bulleted overview of all the time sensitive observations noted during inspection. This helpful overview is not a substitution for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report as the Summary Page does not include photographs, photo captions, or informational comments.
Summary
Concerns
- SFBE-7 Structural Frame and Building Envelope:
A passive roof vent (above room 308) is missing its rain hat. Moisture intrusion was noted in room 308. This vent needs to be repaired or replaced as necessary to protect against further water intrusion.
- MES-1 Mechanical and Electrical System:
The plumbing supply system is ACTIVELY leaking in the crawlspace. At the time of the inspection water was flowing enough to create puddles. Not all leaks were identified by the inspector, but enough leaks were found to suggest that the entire supply system needs to be reviewed and repaired by a licensed plumber. With a 3 story structure it is impossible during an inspection to determine which floor has a problem, since water will follow the pipes through the walls until it gets to the crawlspace.
Since there was evidence found indicating that this building was originally plumbed with Polybutylene pipes, A licensed and bonded commercial plumbing company should be retained to assess the scope of repairs required.
(Inspector noted that the angle stops on the first and second floor were all replaced with quarter turn valves, but NONE of the angle stops on the third floor were replaced. This leads me to suspect that the first two floor had plumbing updates and the third floor did not...)
Repairs
- GPC-1 General Physical Condition :
The grounds around the building are sloped with different elevations and underground drainage is expected but not verified. There were no visible signs of poor drainage.
- U-3 Utilities:
The main gas shutoff is located at the meter... However, the valve is partially buried in the ground and needs to be excavated so that it is accessible for service or emergencies.
- SFBE-1 Structural Frame and Building Envelope:
This crawlspace is a mess. The insulation is marginal at best. Missing in some areas, and destroyed by rodents and others. Plumbing is exposed not insulated properly in areas. Electrical wires are run freely and not properly supported.
This area needs to be cleaned out and reconditioned. All insulation should be removed and replaced to modern standard and properly supported. When the insulation is removed as the perfect time to go through and air seal utility openings in the floor and do the rodent exclusionary work that needs to take place to prevent them from returning.
- SFBE-3 Structural Frame and Building Envelope:
A majority of the siding on this building is "EIFS" (Exterior Insulation and Finish Systems), commonly called "Synthetic Stucco." I did not perform a test for possible water intrusion, as that requires drilling holes through the material. Examples of issues found during this inspection include:
- There are areas of damage that need to be repaired.
- It was also noted that the sections at the lower HVAC units appear to be holding water enough to cause algae growth.
- Trim around widows needs to be sealed to prevent water intrusion (the tile facade is mounted on top of the EIFS exterior)
This finishing system needs to be repaired and verified watertight by a specialist. If water gets behind this product it will cause extensive damage to the structure.
- SFBE-5 Structural Frame and Building Envelope:
The glazing between glass panes are failed at some windows. This issue is a cosmetic one. Failed glazing units should be replaced with new ones.
- MES-5 Mechanical and Electrical System:
The electrical panel in the maintenance room of the basement was not inspected, since it is inaccessible due to excessive storage in front of the panel. The NEC requires 36 inches of working clearance in front of electrical panels. Inspector suggests that you have this Challenger panel inspected once the appropriate acces is provided.
- MES-6 Mechanical and Electrical System:
Electrical issues that require repair include the following:
- Overheated (scorched) wire noted on the circuit labeled 122 in the right panel of the first floor. This usually indicates a loose connection that can be a fire hazard.
- Electrical bonding conductor in the laundry area should be properly attached to the pipes with a rated clamp.
- Unprofessional wiring on the third floor. It wire leaves the panel without a protective grommet or bushing to feed the outlet.
These issues need to be researched and repaired by a licensed electrician.
- CAI-2 Common Areas (Interior):
The signage on the employee bathrooms should be properly installed. These bathrooms are not intended for public use, nor are they ADA compliant, so the signage should be permanent, not a printed out sheet of orange paper.
- GR-2 Guest Rooms:
The following issues were noted in the first floor rooms:
- One or more bathroom vent fans are not pulling any air and need to be repaired or replaced
- One or more bathroom heat lamps, have been replaced with a standard lightbulb. As such, the bathroom has no heat source. The lightbulb should be swapped out for one that generates heat.
- There are dings and dents and marks in the paint finishes on some of the walls. This is a cosmetic concern.
- One or more of the positive stop mechanisms have been removed from the windows. This mechanism needs to be replaced to restore safety and prevent the window from being opened past a certain 4 inches.
- The toilet in room # 119 has been leaking at the base, and my moisture meter shows high readings. It should be removed and any repairs necessary should be performed prior to replacing the wax ring and securing the toilet back to the floor.
- The toilet in room 119 continues to run periodically. The flapper valve is leaking into the bowl causing it to waste water.
- Your blow dryer was noted to be missing from its base.
- GR-3 Guest Rooms:
The following issues were noted in Room #:
- The following issues were noted in these rooms :
- One or more bathroom vent fans are not pulling any air and need to be repaired or replaced
- One or more bathroom heat lamps, have been replaced with a standard lightbulb. As such, the bathroom has no heat source. The lightbulb should be swapped out for one that generates heat.
- There are dings and dents and marks in the paint finishes on some of the walls. This is a cosmetic concern.
- One or more of the positive stop mechanisms have been removed from the windows. This mechanism needs to be replaced to restore safety and prevent the window from being opened past a certain 4 inches.
- The shower supply valve in room 217 needs to be repaired or replaced it is barely functional.
- I some of the rooms are missing the hairdryer.
- The stopper in the bathroom sink needs to be replaced in room number 212
- Hey sink drain in room number 221 needs to be cleared it is backed up.
- GR-4 Guest Rooms:
The following issues were noted in Room #:
- One or more bathroom vent fans are not pulling any air and need to be repaired or replaced
- One or more bathroom heat lamps, have been replaced with a standard lightbulb. As such, the bathroom has no heat source. The lightbulb should be swapped out for one that generates heat.
- There are dings and dents and marks in the paint finishes on some of the walls. This is a cosmetic concern.
- One or more of the positive stop mechanisms have been removed from the windows. This mechanism needs to be replaced to restore safety and prevent the window from being opened past a certain 4 inches.
- Some of these rooms have old and unreliable angle stops that need to be replaced ASAP to prevent plumbing leaks.
- The toilet in room #320 is loose at the floor and needs to be properly secured. You should probably replace the wax ring as part of this repair.
- The stopper for the bathroom sink is not connected in room number 322
- Prior water intrusion was noted around some of the windows. At the moment of this inspection all of the evidence tested dry with my moisture meter. However, these rooms are on the top floor so these areas need to be monitored to determine whether or not there is a water intrusion issue during heavy rains.
Maintenance Items
- GPC-4 General Physical Condition :
The parking lot generally is intact with some minor cracks in some surface areas typical of its age. It is recommended to schedule a maintenance coating which may also require painting new lines for parking spaces .
- CAI-1 Common Areas (Interior):
Multiple water stains were noted in ceiling tiles. A representative sampling of these stains were tested for moisture, and tested dry. These cellulose tiles should be replaced so that any new leaks will be readily discernible.
Due Diligence Items
- U-1 Utilities:
The main water shutoff was not located during this inspection. Consult with the current owner to learn where the valve is located. This is important information.
- U-2 Utilities:
The main electrical shutoff appears to be located in the maintenance room of the basement. Consult with the current owner to verify that this is in fact the main shutoff. Each floor also has shutoffs in each panel. This is important information.
- U-4 Utilities:
Inspector strongly suggests that you have a sewer scope provided to determine the condition of the lateral sewer line from the property to the city right of way.
- U-5 Utilities:
There are T-Mobile towers on the roof. You should request all relevant paperwork regarding this installation.
- MES-2 Mechanical and Electrical System:
The drains all appear functional... but you really have no idea until you put a camera down the line. Inspector suggests getting a sewer scope inspection.
- MES-3 Mechanical and Electrical System:
This is a relatively new installation that should have a warranty. You should request installation information.
- MES-10 Mechanical and Electrical System:
The elevator was not included in this inspection and is hereby excluded from this report. You should request maintenance and inspection records from the seller.
It should be noted that the elevator machine room has a fan set up to blow on the equipment. This makes it appear that the equipment might be running too hot. Sliding bamboo covers
- FP-1 Fire Protection:
The fire alarm/protection system was not included in this inspection and is hereby excluded from this report. You should request testing, maintenance, and inspection records from the seller.
Items To Monitor
- SFBE-6 Structural Frame and Building Envelope:
The roof covering is a rolled asphalt material with a reflective coating that has been applied. The roof will need periodical coatings. Also, there is evidence of prior repairs to this roof.
The roof is functioning well at this point, but should be monitored an a semi-annual basis for the first few years of ownership to get an idea of the required maintenance schedule and to catch any issues as they occur. It is important to remember that T-Mobile technicians may be accessing this roof to work on the cellular arrays, and that could cause premature wear on portions of this roof.
Your Optimized Commercial Building Report
General Physical Condition
Styles and Materials
Topography
Storm Water Drainage
Access and Egress
Paving, Curbing and Parking
Structural Frame and Building Envelope
Styles and Materials
Crawlspace
Sidewall System (exterior wall cladding and components)
Fenestration System (i.e. windows, openings, doors etc.)
Roofing
Mechanical and Electrical System
Styles and Materials
Plumbing water supply and Distribution and Fixtures
Plumbing Drain, Waste and Vent Systems
Domestic hot water production
Electric Distribution
Vertical Transportation (Elevators and Escalators)
General Physical Condition
Styles and Materials
General Topography: Flat
Storm Water Drainage: Underground Drains
Access and Egress: Paved Driveway
Paving Curbing Parking: Asphalt Parking Lot
Number of Parking levels: One
Number of parking spaces: 50
Method used to determine parking spaces: estimated roughly
Topography
The grounds around the building are sloped with different elevations and underground drainage is expected but not verified. There were no visible signs of poor drainage.
Storm Water Drainage
Storm water run-off is disposed of through the municipal drains at the street. There were no evidence to suggest standing water or problems in removing water.
Access and Egress
The main entrance to the building provides access to visitors and staff. There is a rear basement access for loading or unloading supplies. The north end has a fire escape door.
Paving, Curbing and Parking
The parking lot generally is intact with some minor cracks in some surface areas typical of its age. It is recommended to schedule a maintenance coating which may also require painting new lines for parking spaces .
Utilities
Styles and Materials
Water Source: Public Utility
Electric source: Public Utility, SnoCoPUD
Gas supply: Natural Gas, PSE
Sanitary Sewer: Public sewer system
Water
The main water shutoff was not located during this inspection. Consult with the current owner to learn where the valve is located. This is important information.
Electricity
The main electrical shutoff appears to be located in the maintenance room of the basement. Consult with the current owner to verify that this is in fact the main shutoff. Each floor also has shutoffs in each panel. This is important information.
Natural gas
The main gas shutoff is located at the meter... However, the valve is partially buried in the ground and needs to be excavated so that it is accessible for service or emergencies.
Sanitary Sewer
Inspector strongly suggests that you have a sewer scope provided to determine the condition of the lateral sewer line from the property to the city right of way.
Special Utility Systems
There are T-Mobile towers on the roof. You should request all relevant paperwork regarding this installation.
Structural Frame and Building Envelope
Styles and Materials
Foundation: Poured Concrete, Pier
Method used to observe Crawlspace Cellars or Basement: Crawled, Walked
Building Type: Wood Frame, EIFS (Exterior Insulation Finish System)
Roof-Type: Gable
Roof Structure: Not visible
Method used to observe attic: Inaccessible
Ventilation: Passive
Exterior Entry Doors: Steel, Insulated glass
Window Types: Thermal/Insulated, Sliders
Siding Material: EIFS, Ceramic Tile
Roof Covering: Roll/Selvage
Viewed roof covering from: Walked roof
Crawlspace
This crawlspace is a mess. The insulation is marginal at best. Missing in some areas, and destroyed by rodents and others. Plumbing is exposed not insulated properly in areas. Electrical wires are run freely and not properly supported.
This area needs to be cleaned out and reconditioned. All insulation should be removed and replaced to modern standard and properly supported. When the insulation is removed as the perfect time to go through and air seal utility openings in the floor and do the rodent exclusionary work that needs to take place to prevent them from returning.
Sidewall System (exterior wall cladding and components)
A majority of the siding on this building is "EIFS" (Exterior Insulation and Finish Systems), commonly called "Synthetic Stucco." I did not perform a test for possible water intrusion, as that requires drilling holes through the material. Examples of issues found during this inspection include:
- There are areas of damage that need to be repaired.
- It was also noted that the sections at the lower HVAC units appear to be holding water enough to cause algae growth.
- Trim around widows needs to be sealed to prevent water intrusion (the tile facade is mounted on top of the EIFS exterior)
This finishing system needs to be repaired and verified watertight by a specialist. If water gets behind this product it will cause extensive damage to the structure.
Exterior photos 📸
Fenestration System (i.e. windows, openings, doors etc.)
The glazing between glass panes are failed at some windows. This issue is a cosmetic one. Failed glazing units should be replaced with new ones.
Roofing
The roof covering is a rolled asphalt material with a reflective coating that has been applied. The roof will need periodical coatings. Also, there is evidence of prior repairs to this roof.
The roof is functioning well at this point, but should be monitored an a semi-annual basis for the first few years of ownership to get an idea of the required maintenance schedule and to catch any issues as they occur. It is important to remember that T-Mobile technicians may be accessing this roof to work on the cellular arrays, and that could cause premature wear on portions of this roof.
Mechanical and Electrical System
Styles and Materials
Plumbing Water Distribution (inside building): Copper, POLY
Plumbing Waste: ABS
Water Heater Power Source: Gas (quick recovery)
Water Heater Capacity: Tankless
Water Heater Manufacturer: Rinnai
Water Heater Location: Basement
Heat Type: Heat Pump Forced Air (also provides cool air)
Number of Heat Systems (excluding wood): One Per Room, One for common areas
Energy Source for Heat: Electric
Heat System Brand: Various
Ductwork: N/A
Electrical Service Conductors: Below ground
Units individually metered (Electrical): No
Panel capacity: Adequate
Panel Type: Circuit breakers
Electric Panel Manufacturer: CHALLENGER, SQUARE D
Vertical Transportation Type: One Elevator cab
Plumbing water supply and Distribution and Fixtures
The plumbing supply system is ACTIVELY leaking in the crawlspace. At the time of the inspection water was flowing enough to create puddles. Not all leaks were identified by the inspector, but enough leaks were found to suggest that the entire supply system needs to be reviewed and repaired by a licensed plumber. With a 3 story structure it is impossible during an inspection to determine which floor has a problem, since water will follow the pipes through the walls until it gets to the crawlspace.
Since there was evidence found indicating that this building was originally plumbed with Polybutylene pipes, A licensed and bonded commercial plumbing company should be retained to assess the scope of repairs required.
(Inspector noted that the angle stops on the first and second floor were all replaced with quarter turn valves, but NONE of the angle stops on the third floor were replaced. This leads me to suspect that the first two floor had plumbing updates and the third floor did not...)
Plumbing Drain, Waste and Vent Systems
The drains all appear functional... but you really have no idea until you put a camera down the line. Inspector suggests getting a sewer scope inspection.
Domestic hot water production
This is a relatively new installation that should have a warranty. You should request installation information.
Electric Distribution
The electrical panel in the maintenance room of the basement was not inspected, since it is inaccessible due to excessive storage in front of the panel. The NEC requires 36 inches of working clearance in front of electrical panels. Inspector suggests that you have this Challenger panel inspected once the appropriate acces is provided.
Electrical issues that require repair include the following:
- Overheated (scorched) wire noted on the circuit labeled 122 in the right panel of the first floor. This usually indicates a loose connection that can be a fire hazard.
- Electrical bonding conductor in the laundry area should be properly attached to the pipes with a rated clamp.
- Unprofessional wiring on the third floor. It wire leaves the panel without a protective grommet or bushing to feed the outlet.
These issues need to be researched and repaired by a licensed electrician.
Vertical Transportation (Elevators and Escalators)
The elevator was not included in this inspection and is hereby excluded from this report. You should request maintenance and inspection records from the seller.
It should be noted that the elevator machine room has a fan set up to blow on the equipment. This makes it appear that the equipment might be running too hot. Sliding bamboo covers
Fire Protection
Styles and Materials
Sprinkler system: None
Standpipes: Present but not tested
Fire Hydrant: Yes on property
Fire Alarm system: Yes but did not test for operation
The fire alarm/protection system was not included in this inspection and is hereby excluded from this report. You should request testing, maintenance, and inspection records from the seller.
Common Areas (Interior)
Styles and Materials
Ceiling Materials: Suspended ceiling panels
Wall Material: Drywall
Floor Covering(s): Carpet
Interior Doors: Metal
Window Types: Sliders
Ceiling, Walls, Floors
Multiple water stains were noted in ceiling tiles. A representative sampling of these stains were tested for moisture, and tested dry. These cellulose tiles should be replaced so that any new leaks will be readily discernible.
Windows and Doors
Guest Rooms
General Condition Of Rooms
The guest rooms were inspected by the representative sampling system. In total, 16 of the 73 guest rooms were inspected. The photos from the rooms are here...
Repair Issues Noted In Rooms
The following issues were noted in 1st floor Rooms # 113, 119, 124: : .
The following issues were noted in 2nd Floor Rooms # 212, 213, 215, 217, 221: :
.
The following issues were noted in 3rd Floor Rooms # 303, 308, 312, 318, 320, 322: : .
The following issues were noted in the first floor rooms:
- One or more bathroom vent fans are not pulling any air and need to be repaired or replaced
- One or more bathroom heat lamps, have been replaced with a standard lightbulb. As such, the bathroom has no heat source. The lightbulb should be swapped out for one that generates heat.
- There are dings and dents and marks in the paint finishes on some of the walls. This is a cosmetic concern.
- One or more of the positive stop mechanisms have been removed from the windows. This mechanism needs to be replaced to restore safety and prevent the window from being opened past a certain 4 inches.
- The toilet in room # 119 has been leaking at the base, and my moisture meter shows high readings. It should be removed and any repairs necessary should be performed prior to replacing the wax ring and securing the toilet back to the floor.
- The toilet in room 119 continues to run periodically. The flapper valve is leaking into the bowl causing it to waste water.
- Your blow dryer was noted to be missing from its base.
The following issues were noted in Room #:
- The following issues were noted in these rooms :
- One or more bathroom vent fans are not pulling any air and need to be repaired or replaced
- One or more bathroom heat lamps, have been replaced with a standard lightbulb. As such, the bathroom has no heat source. The lightbulb should be swapped out for one that generates heat.
- There are dings and dents and marks in the paint finishes on some of the walls. This is a cosmetic concern.
- One or more of the positive stop mechanisms have been removed from the windows. This mechanism needs to be replaced to restore safety and prevent the window from being opened past a certain 4 inches.
- The shower supply valve in room 217 needs to be repaired or replaced it is barely functional.
- I some of the rooms are missing the hairdryer.
- The stopper in the bathroom sink needs to be replaced in room number 212
- Hey sink drain in room number 221 needs to be cleared it is backed up.
The following issues were noted in Room #:
- One or more bathroom vent fans are not pulling any air and need to be repaired or replaced
- One or more bathroom heat lamps, have been replaced with a standard lightbulb. As such, the bathroom has no heat source. The lightbulb should be swapped out for one that generates heat.
- There are dings and dents and marks in the paint finishes on some of the walls. This is a cosmetic concern.
- One or more of the positive stop mechanisms have been removed from the windows. This mechanism needs to be replaced to restore safety and prevent the window from being opened past a certain 4 inches.
- Some of these rooms have old and unreliable angle stops that need to be replaced ASAP to prevent plumbing leaks.
- The toilet in room #320 is loose at the floor and needs to be properly secured. You should probably replace the wax ring as part of this repair.
- The stopper for the bathroom sink is not connected in room number 322
- Prior water intrusion was noted around some of the windows. At the moment of this inspection all of the evidence tested dry with my moisture meter. However, these rooms are on the top floor so these areas need to be monitored to determine whether or not there is a water intrusion issue during heavy rains.