🪠 PLUMBING
This is a list of all of the plumbing items found during this inspection. A licensed plumbing contractor can use this list to further evaluate and repair the plumbing system.
🪠 PLUMBING
Repairs
- HB-3 HALL BATHROOM - Bathtub / Shower:
INADEQUATE HOT WATER TEMPERATURES IN SHOWERS
I did not get adequate hot water when testing the bathroom showers on the main floor. Building standards do not consider water hot until at least 100 degrees F. I generally expect that fixtures, when tested in full hot, should provide hot water to roughly 120 degrees F, though this can vary by the fixture's proximity to the water heater. Hot water at any given fixture should never exceed 120 degrees F. I recommend additional inspection of these shower fixtures by a qualified plumbing contractor. Repair could necessitate adjustment of the water heater or downstream mixing valves or possibly even eliminating redundant mixing valves.
Bathroom LocationsPrimary BathroomHall Bathroom
Recommended Maintenance
- K-2 KITCHEN - Dishwasher:
NO WATER HAMMER ARRESTOR WAS FOUND - DISHWASHER
Water hammer arrestors are required where quick closing valves are utilized - this is most dishwashers and washing machines. Installation of a hammer arrestor device is recommended for improved reliability of the piping system.
Improve Or Upgrade Items
- P-2 PLUMBING - Water Service Supply:
CONSIDER A FLOW SENSOR ON THE MAIN WATER PIPE
A Flo water sensor should be considered to protect the building. These are smart home technologies that can monitor the house for leaks and shut the water to the home off in case leaks are detected.
- L-3 LAUNDRY - Washer:
MOISTURE ALARM RECOMMENDED
A moisture alarm with water shut-off features is recommended under the washing machine to protect against accidental leaks in the supply hoses. Pans can be effective when there is a drain, but even these will not protect against a burst supply connector. A moisture alarm with automatic shut-off will. Watts is a brand I have seen installed: Link. Please also note that appliance manufacturers recommend replacing supply hoses every 5 years to reduce the risk of failure.
Due Diligence Items
- P-8 PLUMBING - Waste Pipe and Discharge:
ONSITE SEPTIC SYSTEM
Based on visible components, this property appears to have a private on-site septic system. These are specialty systems and are excluded from this inspection. Comments in this report related to this system are made as a courtesy only and are not meant to be a substitute for a full evaluation by a qualified specialist. Generally, septic tanks should be pumped and inspected every 3 years. Depending on the type of system and municipal regulations, inspection and maintenance may be required more frequently, often annually. I recommend:
- Investigating any information about this system's maintenance and repair history
- Reviewing any documentation available for this system
- Learning inspection and maintenance requirements for this system
- Hire a qualified specialist to evaluate, perform maintenance and make repairs as needed
- AP-1 ADDITIONAL PLUMBING - Irrigation:
IRRIGATION SYSTEM NOTED
An exterior irrigation system was noted for this yard. Sprinkler systems are beyond the scope of this inspection. My own experience with irrigation systems is that they require annual attention/repair/servicing after every winter.
Recommendation
Inquire with the seller for any information about winterizing this system, as this should be done before cold weather. When testing the system, be sure sprinkler heads are adjusted so the system is not watering the side of the house. Hire a specialist to evaluate this system further as desired.
- L-4 LAUNDRY - Washer:
ROUGHED IN LAUNDRY FACILITIES
It looks as though a 2nd laundry facility has been roughed in for this building. Inquire with the seller regarding any additional information.
Items for Monitoring
- P-10 PLUMBING - Exterior Hose Bibs:
BE SURE TO WINTERIZE HOSE BIBS PRIOR TO FREEZING WEATHER
These hot and cold hose bibs should be winterized during cold weather to prevent freezing.