How to Read This Report
This report, whether viewed digitally or in printed form, should be reviewed in full color so that photographs are clearly discernible and on a device or page width of no less than 8.5 inches. References to the right and left sides of the building are based on facing the front of the structure as shown on the report cover. The client has a duty and obligation to read the entire report. Please contact the inspector with any questions or concerns.
This inspection report is intended to identify readily observable major structural deficiencies, inoperative conditions, and noticeable moisture-related concerns in the areas inspected. The report may also note safety concerns and recommended upgrades that should be considered. Conditions may exist that were not observed or reported due to concealed, inaccessible, or obstructed areas.
Photos
Photographs included in this report are provided to help illustrate reported conditions or areas of concern. Photos are representative only and may not show the full scope of repairs required. Repairs should be based on the actual conditions observed at the property, not solely on photographs. When viewing the online report, clicking a photo will enlarge it for closer inspection.
Repairs
Any repairs or corrections should be performed by qualified and competent professionals familiar with the type of work being completed. Obtain competitive bids as appropriate and further evaluation when recommended.
Getting the Information to You
This report is designed to present technical information in an accessible format. The online HTML version allows expanded access to additional information. Some words or phrases may appear blue and underlined; clicking these provides links to supplemental resources. Other text colors, if present, have no specific meaning. Please read all written text.
This report may also be printed or saved as a PDF.
Chapters and Sections
The report is organized into chapters that represent major home systems. Each chapter contains sections addressing specific components. When viewing online, chapters can be accessed using the navigation menu on the left side of the screen.
Observation Labels
Observation labels are used to categorize findings. Not all labels appear in every report. Hazardous, Key Concerns, and Further Evaluation Needed items, when used, will appear in both the report and the summary. Other observation types appear only in the report body. Labels are numbered for reference. Colors and icons, when used, do not indicate severity.
Summary Page
For convenience, this report includes a summary listing non-routine maintenance items that the inspector believes should be addressed prior to marketing the home for sale. The summary contains limited information and does not include photos or detailed explanations. Only items classified as Key Concerns, Further Evaluation Needed, Hazardous, and when applicable New Construction Builder Punch List Items, are included.
The report body contains the most complete information, including descriptions, photographs, captions, and when applicable, diagrams, videos, and links. Refer to the full report body when planning repairs or upgrades. The client is responsible for reading the entire report.
Summary
Key Concerns
- B-1 BATHROOM:
Location Full Bathroom: Main Level Front attached to a bedroom
Area: Hydro Massage Tub
Hydro massage tub failed to properly respond to push button control switch at tub when filled with water.
Corrections were needed for the hydro massage tub. Properly correct as needed for function or safety.
- Controls for hydro massage tub appeared coated with substance used to coat tub finish which made the controls for hydro massge tub inoperable. Photos Provided
- P-3 PLUMBING:
Exterior Hose Faucet at Front
Hose faucet observed loose. Properly correct hose faucet installation as needed. Video Provided
- E-1 ELECTRICAL:
Electrical Service
The electrical utility-owned splice for the overhead electrical service near the building was exposed to one or more ungrounded conductors.
Arcing or fire may occur, causing equipment or property damage if contact is made with the bare grounded conductor or other conducting materials. Notify the electrical utility and have it repaired as soon as possible. The utility typically repairs this item the same day at no charge.
- E-2 ELECTRICAL:
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
- R-1 ROOF:
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles were observed to be improperly installed. Refer to the installation instructions, and properly correct where needed.
- Low-sloping roof area with a pitch less than 2:12 was observed improperly covered with roofing shingles.
- Very steep roofs require roof covering that is designed for very steep slopes.
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Remove vegetation debris from roofing where needed.
- Vegetation debris on roof covering concealed view of areas.
- D-1 DECK:
Deck areas were observed ready for corrections now and before use to improve the structure of the deck and to improve the safety aspects for the fall prevention measures installed at deck areas. Refer to the full report for additional information and photos regarding obvious corrections recommended now for any deck areas. A competent deck contractor should check all deck areas. Make deck areas functional, safe and structurally sound where needed.
- Representative Photos Provided
- LG-1 LOTS and GROUNDS:
Drainage was negative, and stormwater will flow toward the structure.
Corrections are recommended to reduce stormwater from flowing towards the foundation. Be careful not to raise the grade near the structure above the foundation waterproofing for the basement areas. Other corrections may also be needed. Check all exterior areas. Monitor stormwater runoff during and after rain. Make appropriate corrections to meet your needs.
Further Evaluations
- P-1 PLUMBING:
Waste Piping
Improper use of a sanitary tee fitting was observed at crawl space.
Waste drain piping was irregular. Further evaluation and proper correction of irregular waste drain piping is recommended.
- Multiple improper use of sanitary T fittings were observed at basement.
- P-2 PLUMBING:
Plumbing Waste Piping
Plumbing waste drain piping was irregular at basement.
Further evaluation and proper correction of irregular waste drain piping is recommended.
- Portions of waste piping appeared to have excessive fall, and the liquids in the waste piping could run past the solids inside the piping, creating a blockage.
- Plumbing waste piping in the basement was observed exiting the foundation at multiple outlets at multiple elevations. Verify the location of the septic tank and that all plumbing waste piping properly discharges to an appropriate area. Properly correct or upgrade as needed.
- Pressure fittings were observed installed at gravity drain piping in basement.
- P-4 PLUMBING:
Multiple plumbing corrections were needed.
A licensed, competent plumbing contractor should further evaluate the entire plumbing system and properly replace or repair it as needed to make it fully functional and safe.
- SH-1 Space Heating:
Instructions for wood burning stoves must be closely adhered to and these instructions often vary by manufacturer.
Wood burning stoves are not fully evaluated when inspected. The inspector recommends further evaluation by a chimney specialist and a review of installation and maintenance instructions before use. Properly correct if needed for function or safety.
- S-1 STRUCTURE:
Floor Framing and Supports
Conditions were observed at the floor system that warrant further evaluation by a specialist.
Crawl space conversion to a basement area was observed. Obtain any available architectural drawings and engineering design documentation that was prepared for the conversion process. Verify that the as-built condition meets the designed criteria. If adequate documentation for the home is unavailable, further evaluation of the structure is recommended by a State-licensed professional engineer who specializes in crawl space-to-basement conversions. Properly correct or upgrade the structure as needed, following the recommendations of the party providing further evaluation.
- Representative Photos Provided
- Irregular addition to the original construction was apparent.
- The foundation was irregular.
- Floor framing was outdated or irregular.
- Shoring or strengthening measures observed were irregular.
- Flooring was noticeably out of level.
- Further evaluation should include a load path analysis for the structure.
Update: State Licensed Professional Engineer confirmed that the modification was inadequate to properly support the structure.
- M-1 MOISTURE:
Wet moisture stains were observed at basement.
Stains are evidence of an undesirable moisture condition. Further evaluation is needed to determine exact source of unwanted moisture. Properly correct source of moisture. Take steps to prevent recurrence. Properly repair affected areas as needed.
- Wet moisture stains were observed at basement front wall.
- Moisture stains were confirmed wet with a moisture meter.
- Standing water was not present.
The Full Report
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Doors
Glazing/Glass
Windows
Stairs/Railings Interior
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Exterior Hose Faucets
Water Heater
Equipment Observed
Plumbing Other
ELECTRICAL
Electrical Inspection
Electrical Service
MAIN PANEL
Branch Wiring
AFCI
GFCI
Receptacle Outlets
Three Wire Receptacles
Lighting/Ceiling Fans
Switches
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Be Proactive Regarding Maintenance:
How much should you budget to maintain a home in the Chattanooga area?
As a general rule, a proper home maintenance budget should be about 2-5% of the value of the home annually. This maintenance budget would include periodic maintenance, general repairs, lawn care, housekeeping and saving any excess funds to budget for predictable replacement of the water heater, central heating/cooling and the roof covering. Should you choose to perform any of these tasks yourself, you should have fewer out of pocket expenditures to properly maintain your home.
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Single Family Home
Site Built, Apparent additions built after original construction were observed.
Approximate Square Footage: 1680
Approximate Year of Original Construction: 1977
Weather during the inspection: Cloudy
Ground/Soil surface conditions: Dry
Approximate Low Temperature During Inspection: 60[F]
Approximate High Temperature During Inspection: Above 60[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access:
Home was empty of furnishings when inspected.
________________________________________________________________________________________________________________________________________________________________
Interior Ceiling Materials: Drywall
Interior Ceiling Condition:
Some wear noted, recondition to your standard
________________________________________________________________________________________________________________________________________________________________
Interior Wall Materials: Drywall and Wood
Interior Wall Condition:
- Some wear noted.
- Recondition to your standard.
________________________________________________________________________________________________________________________________________________________________
Interior Flooring Materials: Wood and Engineered Flooring
- Some wear noted, recondition to your standard
Doors
Doors at Interior
Check all doors. Properly correct interior doors to your standard and to meet your needs.
________________________________________________________________________________________________________________________________________________________________
Doors to Exterior:
Door to Exterior Front Door Front and Rear Doors
Screws were missing at hinges designed to connect the door frame to the structure. Refer to the installation instructions to properly complete the door installation where needed.
- Hinge Screws to Structure Were Missing
Doors to the Exterior
Check all doors to the exterior properly, making doors functional, secure, and weather-tight to meet your needs.
Glazing/Glass
Insulated glass was present.
Single pane glass was present.
Windows
Wood framed windows were present., Vinyl framed windows were present.
One or more storm windows were present. Storm windows are outside the scope of this inspection and were not evaluated.
A representative number of accessible, operable windows were operated and were found generally serviceable within the parameters of their given service life.
Stairs/Railings Interior
Diagram:
Railings and Stairs at the older home, as expected, did not meet current safety standards. Railings and stairs were ready for modernization for improved safety. Evaluate your risk exposure. Consider proper repair or replacement of stairs and railings where needed now for safety and function. Railings and stairs in older houses should be reasonable, considering the needs of individuals with reduced mobility, children, and the elderly who may use the stairs at the home.
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following built-in kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area:
Kitchen
Countertop: Granite
- Serviceable, fulfilling its function
Cabinets: Wood painted
- Serviceable, fulfilling its function
Floor Covering: Wood
- Serviceable, fulfilling its function
Sink: Single Bowl Stainless Steel
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
Disposal: Not Present
Dishwasher: Present and ran through a normal cycle without incident
Range: Cooktop Electric and Separate Electric Oven
Cooktop On/Off Tested Functional
Microwave: Present and On/Off Tested functional
Kitchen Exhaust: Ductless in microwave appeared functional.
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Cooking Appliance: Note (Cooking Appliance Incompatible Storage)
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom
Full Bathroom
Location Full Bathroom: Upstairs
Bathing Area: Shower
- No leaks were observed around the faucet, and the water containment area appeared serviceable.
- Properly maintain tile work to meet your needs.
- The shower was run only briefly as no shower curtain/door was present.
Hand Washing: Vanity with basin
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
Toilet: Water tank type
- No leaks were observed around the toilet, and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
Floor Covering: Tile
- Serviceable, fulfilling its function
Bathroom
Full Bathroom
Location Full Bathroom: Main Level Front attached to a bedroom
Bathing Area: Combination tub and shower
- The shower was run only briefly as no shower curtain/door was present.
- Properly maintain tile work to meet your needs.
Hand Washing: Vanity with basin
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
Toilet: Water tank type
- No leaks were observed around the toilet, and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
Floor Covering: Tile
- Serviceable, fulfilling its function
Location Full Bathroom: Main Level Front attached to a bedroom
Area: Hydro Massage Tub
Hydro massage tub failed to properly respond to push button control switch at tub when filled with water.
Corrections were needed for the hydro massage tub. Properly correct as needed for function or safety.
- Controls for hydro massage tub appeared coated with substance used to coat tub finish which made the controls for hydro massge tub inoperable. Photos Provided
Bathroom
Full Bathroom
Location Full Bathroom: Main Level Rear
Bathing Area: Shower
- No leaks around the shower faucet were observed, and the water containment area appeared serviceable.
- The shower was run only briefly as no shower curtain/door was present.
Hand Washing: Vanity with basin
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
Toilet: Water tank type
- No leaks were observed around the toilet, and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
Floor Covering: Tile
- Serviceable, fulfilling its function
LAUNDRY
Laundry Connections
Laundry: Connections Available
Clothes washer and dryer connections were available.
Laundry appliances were not observed connected to the laundry connections during the inspection. Laundry faucets are not operated when the basin beneath the faucets is inadequate to contain the faucet flow without a hose being connected to the faucets. Verify your clothes dryer exhaust is functional, safe, and properly installed to meet the requirements of the clothes dryer manufacturer.
PLUMBING
Supply Piping
Supply Piping: Copper, PEX
Waste Piping
Waste Piping: Plastic
Waste Piping
Improper use of a sanitary tee fitting was observed at crawl space.
Waste drain piping was irregular. Further evaluation and proper correction of irregular waste drain piping is recommended.
- Multiple improper use of sanitary T fittings were observed at basement.
Plumbing Waste Piping
Plumbing waste drain piping was irregular at basement.
Further evaluation and proper correction of irregular waste drain piping is recommended.
- Portions of waste piping appeared to have excessive fall, and the liquids in the waste piping could run past the solids inside the piping, creating a blockage.
- Plumbing waste piping in the basement was observed exiting the foundation at multiple outlets at multiple elevations. Verify the location of the septic tank and that all plumbing waste piping properly discharges to an appropriate area. Properly correct or upgrade as needed.
- Pressure fittings were observed installed at gravity drain piping in basement.
Apparent Vent Piping
Plastic
Exterior Hose Faucets
Performance: Loose
Exterior Hose Faucet at Front
Hose faucet observed loose. Properly correct hose faucet installation as needed. Video Provided
Water Heater
Water Heater
Discharge Piping: Missing
Water Heater
Water heater temperature and pressure relief valve did not appear to have a discharge extension piping installed.
Refer to discharge piping general guidelines. Proper correction is needed for correct function and safety.
Water Heater - Temperature and Pressure Relief Valve - Discharge Piping General Guidelines
Consult a knowledgeable, competent, qualified plumbing contractor for specific requirements in your area.
Valve Manufacturer WARNING: To avoid water damage and/or scalding due to valve operation, a properly installed discharge line must be connected to valve outlet and run to a safe place of disposal.
- Discharge line shall serve a single relief device and shall not connect to piping serving any other relief device or equipment.
- The discharge line shall be installed in a manner that does not cause personal injury or structural damage.
- The discharge line shall be installed to a termination point that is readily observable by the building occupants.
- The discharge line shall be installed to allow complete drainage of both the valve and the discharge line.
- No reducing coupling or other restriction shall be installed in the discharge line.
- The discharge line must pitch downward from the valve and terminate not more than 6 inches (152 mm) above and not less than two times the discharge pipe diameter above the floor or flood level rim of the waste receptor.
- A proper air gap should be present above the floor or flood level rim of the waste receptor where the discharge pipe drains. The discharge piping should not drain into an indirect waste receptor such as a leak pan beneath a water heater.
- The discharge line must terminate through plain (unthreaded) pipe.
- Discharge line material must conform to local plumbing code or A.S.M.E. requirements. PVC piping is not rated for hot water and shall not be used.
- Excessive length - more than 30 feet (9.14m), use of more than four elbows or bends in discharge piping, or reduction of discharge line size will cause a restriction and reduce the discharge capacity of the valve.
- No shut-off valve shall be installed between the relief valve and tank, or in the discharge line.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Missing
A plumbing thermal expansion tank was not observed near the water heater.
Monitor this area for leaks adding an expansion tank if needed.
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Basement
________________________________________________________________________________________________________________________________________________________________
Plumbing Other
Multiple plumbing corrections were needed.
A licensed, competent plumbing contractor should further evaluate the entire plumbing system and properly replace or repair it as needed to make it fully functional and safe.
CENTRAL SYSTEM
Central Heat/Cool
Central Heating/Cooling
Split, Forced Air Heat Pump System served: System served the entire home
Brand Furnace: Carrier / Location: Unfinished Basement
Size: 3.5 ton / Year of Manufacture: 2024 / Fuel: Electric Heat Pump
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Carrier / Location: Exterior
Year of Manufacture: 2024 / Fuel: Electric
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Gravity drain for condensate
________________________________________________________________________________________________________________________________________________________________
Cooling Function:
Cooling System Functional
The inspector adjusted the thermostat. The cooling system engaged and was found to be functional.
________________________________________________________________________________________________________________________________________________________________
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding ductwork inspection:
During the inspection, the uniformity or adequacy of heating or cooling supply to the various rooms is not determined.
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served (if present), shade, climate zone, as well as the size, number, and placement of windows, must be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the installed central heating and cooling equipment.
Properly maintain the ductwork system to meet your comfort needs and ensure it operates efficiently.
Ductwork:
Ductwork
A single central heat/cool system was installed serving multiple floor levels. When one central system serves multiple floor levels, expect some temperature disparity between floor levels. Seasonal adjustment of vent diffusers may help. A heating contractor may also be hired to modify the system. Monitor your comfort level and correct as desired to meet your needs.
Ductwork
The central heat/cool system served multiple floor levels with an air return installed only at one of those levels. Expect temperature disparity between floor levels. Monitor your comfort level and correct as needed.
Space Heating
Fireplace
Fireplace Use Nonessential
Regarding Fireplace Use:
Fireplace use was nonessential. The installed fireplace was not the sole heating system for the inspected property and does not have to function if you do not desire to use the fireplace area. Typically, deficient fireplaces are not listed in the summary of the report. Properly repair fireplace area for function and safety if use is desired.
Type: Masonry Fireplace
Vented
Regarding Vented Fireplaces or Fireplaces with a Flue
This type of fireplace will exhaust directly to an exterior area in an effort to reduce or eliminate smoke, fumes and carbon monoxide build up in the interior living space areas. You should become familiar with care and maintenance procedures for any installed fireplace as some procedures will be specific to what type of fireplace is installed. If you choose not to learn about the care and maintenance requirements for the installed fireplace, you should have a competent qualified chimney specialist check and inspect the fireplace before initial use and then as directed by the chimney specialist thereafter. Properly maintain any fireplace as needed for proper function and safety.
Firebox: Stove Blocked Access
Installed stove blocked access to fireplace. Firebox area was not viewed by home inspector.
Chimney Type: Stone Exterior
Solid Fuel Stove
Wood Stove Observed but not evaluated
Instructions for wood burning stoves must be closely adhered to and these instructions often vary by manufacturer.
Wood burning stoves are not fully evaluated when inspected. The inspector recommends further evaluation by a chimney specialist and a review of installation and maintenance instructions before use. Properly correct if needed for function or safety.
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment, and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment typically consists of one or more installed breaker panels, with branch wiring extending to all equipment, receptacles, lighting outlets, and devices, such as light switches. The inspection report focuses on wiring operating between 100-250 Volts. While the system's Amperage and Voltage are recorded, it is not measured during the inspection. Most low-voltage wiring is excluded from the performed inspection. Low-voltage items, such as heating and cooling thermostats, are used to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify that each lamp or bulb is suitable for the installed lighting fixture. The inspector recommends reviewing the bulb or lamp installations for each fixture, making corrections as needed for safety and proper function. Common errors include installing 100-watt bulbs in fixtures rated for 60-watt maximum bulbs, and using interior-rated bulbs in exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. A competent, licensed electrical contractor should correct electrical installation issues and address any functional issues that require correction. Most, if not all, electrical corrections should be considered a safety concern.
Electrical Service
System Amperage and Voltage, identified but not measured: 200 Amps - 120/240 Volts
Electrical Service Type: Overhead, Representative Photo, Service Older
The electrical service appeared older. Monitor area budgeting replacement when necessary.
Aerial: Drop Exposed Splice
Electrical Service
The electrical utility-owned splice for the overhead electrical service near the building was exposed to one or more ungrounded conductors.
Arcing or fire may occur, causing equipment or property damage if contact is made with the bare grounded conductor or other conducting materials. Notify the electrical utility and have it repaired as soon as possible. The utility typically repairs this item the same day at no charge.
MAIN PANEL
Main Electrical Panel
Main Breaker Panel Bedroom
- Breaker panel shown with cover removed by other parties present during the home inspection.
Routine Correction Needed
Electrical Panel Bedroom
Routine corrections were needed at the electrical distribution panel.
These corrections should be performed now or may be scheduled with other electrical work if that work is done in the near future.
- For panel directory, properly index or label each electrical panel circuit as needed for clarity and safety.
- Index appeared vague. Properly index each electrical circuit where needed for clarity and safety.
Branch Wiring
Material: Copper
Wiring Method: Non Metallic Sheathed Cable
Improper Wiring, Service Disconnect Missing
Electrical service disconnect was not observed near water heater at Basement. An electrical service disconnect within view of the permanently installed appliance is an important safety device for personnel servicing equipment. A competent electrical contractor should properly install an electrical service disconnect where missing for safety.
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
AFCI
AFCI Residential
What is Arc Fault Circuit Interrupter (AFCI) Protection?
AFCI protection is designed to break the electrical circuit when it detects electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Most, but not all, homes will have a need for additional AFCI protection based on varied municipal enforcement and the numerous changes for which areas require AFCI protection. Evaluate your risk exposure. Consider adding AFCI protection where needed for improved safety, particularly where construction was completed 2002 or later.
Modern Locations Where AFCI Protection is Known to Improve Safety:
Dwelling Units. All 120-volt, single-phase, 10-, 15-, and 20-ampere branch circuits supplying outlets or devices installed in the following locations:
Kitchens,
Family Rooms,
Dining Rooms,
Living Rooms,
Parlors, Libraries,
Dens,
Bedrooms,
Sunrooms,
Recreation Rooms,
Closets,
Hallways,
Laundry Areas,
or similar areas.
Testing AFCI Function
The inspector uses push button at AFCI breakers, where installed, to confirm AFCI protection trips. Once tripped, the inspector checks indexed electrical circuits to determine where AFCI protection is present or missing.
Obvious locations lacking AFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired AFCI receptacles or breakers are listed in the summary of the report. Evaluate your risk exposure.
No AFCI Built Before 2002
Areas That Did Not Appear AFCI Protected
No AFCI protection was observed at inspected property. AFCI protection is not expected for homes built before 2002. If installation of AFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI
GFCI Residential
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Dwelling Units.
(A) Dwelling Units
All 125-volt through 250-volt receptacles installed in the following locations and supplied by single phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.
(3) Outdoors
(4) Crawl spaces - at or below grade level
(4) Basements
(5) Kitchens
(6) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(7) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Boathouses
(9) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(10) Laundry areas
(12) Indoor damp and wet locations
Some exceptions apply, see current standard for a list of exceptions.
(B) Pertains to Other Than Dwelling Units
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
(F) Outdoor Outlets. For dwellings, all outdoor outlets, including outlets installed in the following locations, and supplied-by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, shall be provided with GFCI protection:
(1) Garages that have floors located at or below grade level.
(2) Accessory buildings
(3) Boathouses
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Older Home
GFCI protection was ready for upgrade at older inspected property. Consider modernizing electrical installation adding this shock protection for all electrical areas where GFCI protection is known to improve safety. If installation of additional GFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI: Redundant Protection
GFCI electrical receptacle at upstairs bathroom was redundant to GFCI electrical breaker at breaker panel. Redundant GFCI protection was observed during inspection. While this is not a defect in itself, the occupant should know that redundant protection is present and where redundant devices are to avoid extended loss of use of electrical receptacle or needless electrical service calls.
Receptacle Outlets
Receptacle Appeared Missing: Cooling Unit
Electrical Receptacle Outlet
An electrical receptacle was not observed near the cooling condensing unit at the exterior.
Equipment requiring periodic servicing should have a permanent electrical receptacle installed close by. Consider properly adding an electrical receptacle at exterior ground level within 25 feet of the cooling condensing unit to service this equipment.
Cover Plates: Missing
Electrical Receptacle Outlet
Properly install receptacle cover plates where needed for safety.
Three Wire Receptacles
Three Wire 240V Receptacles Observed
Some older 240V 3 wire electrical receptacle circuits were observed. Typically, these circuits would serve electric clothes dryers or electric kitchen ranges but may also serve other areas. Evaluate your risk exposure and consider upgrade replacement of any 240V 3 wire receptacle circuits where present with a modern 240V 4 wire receptacle circuits for improved safety. Properly maintain older 240V 3 wire receptacle circuits to meet your needs and for safety, if not upgrading older circuits now.
Lighting/Ceiling Fans
Lighting OK
A representative number of installed lighting fixtures were observed and appeared to be functional and generally serviceable within the parameters of their given service life.
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
STRUCTURE
Attic Access
Attic Access: Cathedral
Restrictions: No Attic Access
Attic access did not appear present at inspected property above upstairs rooms or rear addition. Attic area, if present, was not entered or observed during inspection. Small attic areas are not required to be accessible.
Roof Framing
Roof Framing: Not Observed
Framing Access: Finished Prevented
Finished areas prevented the view of structural components, so the inspector did not observe structural areas. Concealed areas were not part of the inspection performed.
Ceiling Framing
Framing Access: Finished Prevented
Finished areas prevented the view of structural components, so the inspector did not observe structural areas. Concealed areas were not part of the inspection performed.
Wall Framing
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector. Concealed areas are not part of the inspection performed.
Underfloor Description
Attributes: Unfinished Basement
Underfloor Area
Access:
- Basement walked
Construction Type:
- Basement - Unfinished
Foundation:
- Concrete Block
Columns or Piers:
- Concrete Block
- Wood
Floor Structure:
- Floor Joists - Solid Wood
- Beam - Built Up Wood
- Beam - Steel I Beam
- Subfloor - Wood
Floor System
Floor Framing and Supports
Conditions were observed at the floor system that warrant further evaluation by a specialist.
Crawl space conversion to a basement area was observed. Obtain any available architectural drawings and engineering design documentation that was prepared for the conversion process. Verify that the as-built condition meets the designed criteria. If adequate documentation for the home is unavailable, further evaluation of the structure is recommended by a State-licensed professional engineer who specializes in crawl space-to-basement conversions. Properly correct or upgrade the structure as needed, following the recommendations of the party providing further evaluation.
- Representative Photos Provided
- Irregular addition to the original construction was apparent.
- The foundation was irregular.
- Floor framing was outdated or irregular.
- Shoring or strengthening measures observed were irregular.
- Flooring was noticeably out of level.
- Further evaluation should include a load path analysis for the structure.
Update: State Licensed Professional Engineer confirmed that the modification was inadequate to properly support the structure.
INSULATION
Above Ceiling Insulation
Recommended Insulation
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Above Ceiling Insulation Not Observed, Undetermined
Consider Improving Insulation: Energy Audit Recommended
Consider obtaining evaluation by an energy auditor for property to improve energy efficiency and comfort.
Wall Insulation
Insulation: Wall Insulation Not Observed, Undetermined
Underfloor Insulation
Insulation: None
Underfloor insulation was not observed at crawl space beneath living space.
Heat Pump: Unfinished Basement
Underfloor area above the unfinished basement did not appear to be properly insulated to maximize the efficiency of the installed heat pump. Recommend adding insulation to R-19 or R-25 levels to lower utility costs.
MOISTURE
Basement
Basement: Practical Steps Basement Moisture, Dehumidifier Present, Interior Damp Proofing Observed, Moisture Stains Observed Dry
Dry moisture stains were observed. Stains are evidence of a prior undesirable moisture condition. Monitor area to verify cause of stain is not still present. Further evaluation may be needed if cause of stains persists. Properly correct cause of stain if needed. Properly repair affected areas as needed.
- Dry moisture stains observed at floor framing visible at basement front. Previous repairs observed. Both areas shown in photos were sampled for mold determination.
A dehumidifier was noted. Be sure to keep a dehumidifier, if needed, to help remove moisture from the air. Dehumidifiers are used to reduce excess moisture and/or condensation problems. Monitor area correcting as necessary to meet your needs and to protect building components.
- Basement area was ventilated. Dehumidifiers are ineffective in basements that are open to the exterior atmosphere.
- Inquire about the purpose of having a dehumidifier present in a ventilated basement area. Correct to meet your needs.
Interior damp proofing was observed applied to basement walls. Waterproofing should be done on exterior walls at and below soil grade at time of construction. Interior damp proofing may indicate moisture penetration. Monitor area and correct as needed.
- Interior Damp Proofing observed at basement wall.
Practical steps to better moisture condition at a typical basement.
- Properly divert any storm water and all gutter down spouts a minimum 10 feet away from foundation.
- Correct any exterior grading issues that prevent storm water from flowing away from foundation.
- Install proper size dehumidifier if needed to help control high humidity.
- Properly drain any excess bulk moisture from basement, if present, to prevent accumulation.
- Take more aggressive steps if necessary such as installing a dewatering system.
Wet moisture stains were observed at basement.
Stains are evidence of an undesirable moisture condition. Further evaluation is needed to determine exact source of unwanted moisture. Properly correct source of moisture. Take steps to prevent recurrence. Properly repair affected areas as needed.
- Wet moisture stains were observed at basement front wall.
- Moisture stains were confirmed wet with a moisture meter.
- Standing water was not present.
Interior Moisture Signs
Interior: Moisture Stains Observed Dry
Dry moisture stains were observed. Stains are evidence of a prior undesirable moisture condition. Monitor the area to verify that the stain's cause is no longer present. Further evaluation may be needed if the cause of the stains persists. Properly correct the cause of the stain if needed. Properly repair affected areas as needed. Affected adjacent areas that are concealed or not readily accessible are not part of the inspection performed.
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Ridge Roof Vent, Gable End Vent
Attic Intake Vents: Soffit Vents Where Installed
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof
Common Limitations: Architectural Design Irregular
Architectural design was irregular. Monitor irregular architecture at roofing budgeting periodic maintenance as needed to help prevent unwanted water entry. Make corrections as needed, when needed.
Roof Style: Multi Plane
Approximate Age of Roof Covering: 2-3 Years
Roofing Material: Composition Dimensional Shingle
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles were observed to be improperly installed. Refer to the installation instructions, and properly correct where needed.
- Low-sloping roof area with a pitch less than 2:12 was observed improperly covered with roofing shingles.
- Very steep roofs require roof covering that is designed for very steep slopes.
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Remove vegetation debris from roofing where needed.
- Vegetation debris on roof covering concealed view of areas.
Gutters and Downspouts
Gutter and Downspout Materials: Metal
The best time to replace guttering is while you are having the roof covering replaced.
Observation:
Gutters suffered from deferred maintenance and were ready for reconditioning. Properly correct as needed for proper function.
Downspout:
Gutters:
Properly maintain rain gutters to meet your needs.
Skylights
Two Skylights Observed, Best Time to Replace a Skylight
The best time to replace a skylight is while you are having the roof covering replaced.
Maintain Instructions not reviewed, Reused
Properly maintain skylight installation to meet your needs and prevent unwanted water entry. Review of skylight installation instructions is not part of this inspection.
SIDING and TRIM
Siding
Siding: Wood
Eaves: Wood
Trim: Wood
Irregularity:
Siding/Trim should be 1-2" away from roofing shingles to facilitate shingle replacement and to prevent siding from wicking moisture from roofing causing damage to siding and adjacent areas. Monitor siding installation budgeting corrections as needed. Consider upgrading area either before painting or when replacing roofing.
Siding:
Siding:
Exterior siding was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Physical Damage Observed
- Failing Paint Observed
- Temporary Repairs Observed
- Rot Observed
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance. Affected adjacent areas that are concealed or not readily accessible are not part of the inspection performed.
Siding - Stucco
Stucco Over Concrete Block where installed
DECK
Deck or Wooden Porch Areas Overall Condition Statement
Inspecting decks which are also known as wooden porches.
Decks and their attached steps are inspected for structural integrity, fall prevention and possible entrapment openings. Concealed areas such as deck footers are not included in the inspection. Most inspected decks will be ready for some correction or upgrade due to age, wear or improper construction. For any areas ready for upgrade, you should evaluate your risk exposure properly correcting as needed for improved structural integrity and improved safety.
Any deck needing correction should be further reviewed and corrections performed by a Competent Qualified Deck Contractor as the deck inspection performed in this report is not meant to discover every possible correction that a deck might need.
Each deck should be properly stained to prolong deck life. A solid deck stain is preferred as it will also protect the deck from sun light damage.
Two useful sources for deck information may be found at the following websites:
https://knoxcounty.org/codes/pdfs/construction_info/DeckInformation.pdf
Deck areas were observed ready for corrections now and before use to improve the structure of the deck and to improve the safety aspects for the fall prevention measures installed at deck areas. Refer to the full report for additional information and photos regarding obvious corrections recommended now for any deck areas. A competent deck contractor should check all deck areas. Make deck areas functional, safe and structurally sound where needed.
- Representative Photos Provided
Deck or Wooden Porch Location, Attributes and Restrictions
Deck or Wooden Porch Structure
Girder or Beam:
Girder or Beam Illustrations:
Joist Hangers:
Deck or Wooden Porch Railings and Stairs
Diagram:
Guardrail:
Railings:
Fall from area did not require a railing, but where installed, railings should meet minimum safety standards to help prevent injury.
Stairs:
Uneven steps were observed. Differing riser heights are a common cause of falls. For safety, the height between the tallest and the shortest riser on a set of stairs should be no more than 3/8". Proper correction is recommended.
LOTS and GROUNDS
Driveway
Walkway
Vegetation
Dead tree limbs were noted and should be properly removed.
Dead or dying trees were observed. Properly trim or remove as needed.
Overhanging tree branches appeared too close above roofing. Air circulation and sunlight help prevent deterioration of roof components. Branches should be properly trimmed back to alleviate this condition.
Trees too close to foundation may impact building. Evaluate your risk exposure removing trees where needed. Correct any affected areas if present.
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Site
Drainage was negative, and stormwater will flow toward the structure.
Corrections are recommended to reduce stormwater from flowing towards the foundation. Be careful not to raise the grade near the structure above the foundation waterproofing for the basement areas. Other corrections may also be needed. Check all exterior areas. Monitor stormwater runoff during and after rain. Make appropriate corrections to meet your needs.


.jpg)
.jpg)
.png)
.jpg)
.jpg)




-2.jpg)


-1.jpg)