How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- K-1 KITCHEN:
Exhaust at Microwave
The deep cabinet above the microwave restricted the exhaust opening at the top of and towards the front of the microwave, which is designed for ductless exhausting. Proper correction is recommended. A competent, qualified contractor capable of reading and following the installation instructions should properly correct the microwave exhaust installation as needed for function and safety.
Multiple corrections are possible to improve the condition or to prevent damage to the cabinet or possibly the exhaust fan.
Some options are:
- It is possible to build a proper structural spacer at least 4" deep that would be attached between the wall behind the microwave and the microwave itself so that the microwave exhaust would properly extend beyond the cabinet front.
- Consider discontinuing use of exhaust fan altogether. If the exhaust fan comes on automatically with microwave use, then consider discontinuing the use of microwave and exhaust altogether.
- Consider replacing the microwave with one that exhausts out the front rather than the top.
- Consider replacing or modifying the cabinet above the microwave to prevent the cabinet from obstructing the exhaust.
Refer to installation instructions. Properly correct as desired to meet your needs, making the system fully functional and safe.
- P-1 PLUMBING:
Exterior Hose Faucet at Rear wall of home
Exterior hose faucet was observed inoperative when inspected.
Properly correct or replace as needed.
- E-1 ELECTRICAL:
Main Breaker Panel Garage
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
- E-2 ELECTRICAL:
Branch Wiring
Improperly terminated wiring was observed in garage between furnace and water heater. Photo Provided
Some exposed loose ends of wiring could not be visually confirmed as being properly disconnected from all electrical systems. Properly terminate exposed wiring ends by adding junction boxes, wire nuts, and covers where needed.
- E-3 ELECTRICAL:
Branch Wiring
Improper wiring was observed at kitchen garbage disposal.
Properly correct any improper wiring where needed for function and safety.
- E-4 ELECTRICAL:
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Multiple electrical receptacles were observed loose.
- Properly correct loose electrical receptacles where needed.
- Some electrical receptacle junction boxes were loose. Properly correct where needed.
A competent electrical contractor should check all receptacles, making them functional and safe where needed.
- E-5 ELECTRICAL:
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were improperly installed.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
- R-1 ROOF:
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles were observed to be improperly installed. Refer to the installation instructions, and properly correct where needed.
- Low-sloping roof area with a pitch less than 2:12 was observed improperly covered with roofing shingles.
- Some shingles observed damaged.
- Some shingles observed worn.
- Temporary repairs observed. Execute permanent corrections where needed.
- Properly correct protruding nails where needed and replace shingles damaged by protruding nails.
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Some kick out flashings appeared omitted.
- R-2 ROOF:
Consider replacement of older roofing.
Weigh your options for repairing roofing now knowing that you should replace it in the near future with the option of proper complete replacement now. Considering that a properly replaced roofing system may last up to three decades it may make better sense to replace the roofing correctly now rather than to repair an older roof system that will have to be replaced soon anyway.
The Full Report
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Doors
Glazing/Glass
Windows
Stairs/Railings Interior
Stairs/Railings Interior
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Exterior Hose Faucets
Water Heater
Equipment Observed
ELECTRICAL
Electrical Inspection
Electrical Service
MAIN PANEL
Branch Wiring
AFCI
GFCI
Receptacle Outlets
Lighting/Ceiling Fans
Lighting/Ceiling Fans
Switches
Smoke Alarms
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Home Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
Be Proactive Regarding Maintenance:
How much should you budget to maintain a home in the Chattanooga area?
As a general rule, a proper home maintenance budget should be about 2-5% of the value of the home annually. This maintenance budget would include periodic maintenance, general repairs, lawn care, housekeeping and saving any excess funds to budget for predictable replacement of the water heater, central heating/cooling and the roof covering. Should you choose to perform any of these tasks yourself, you should have fewer out of pocket expenditures to properly maintain your home.
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Townhouse
Site Built
Approximate Square Footage: 2929
Approximate Year of Original Construction: 2007
Weather during the inspection: Cloudy
Ground/Soil surface conditions: Wet
Approximate Low Temperature During Inspection: 75[F]
Approximate High Temperature During Inspection: Above 80[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Empty of Furnishings
Home was empty of furnishings when inspected.
________________________________________________________________________________________________________________________________________________________________
Ceiling area
________________________________________________________________________________________________________________________________________________________________
Wall Area
Interior Wall Materials: Drywall
Interior Wall Condition:
- Some wear noted.
- Recondition to your standard.
________________________________________________________________________________________________________________________________________________________________
Flooring
Interior Flooring Materials: Carpet, Engineered Flooring, and Tile
- Some wear noted, recondition to your standard
Not Level
Flooring
Flooring appeared out of level. Consider for proper correction to meet your standards.
Doors
________________________________________________________________________________________________________________________________________________________________
Replace, Repair, Check All
Replace, repair or upgrade doors to exterior to meet your needs. Properly correct any affected adjacent areas if present. Check all doors to exterior properly making doors functional, secure and weather tight to meet your needs.
Glazing/Glass
Insulated glass was present.
Windows
Wood framed windows were present.
Escape and Rescue
Consider upgrading emergency escape and rescue window openings.
Window for one or more possible sleeping areas did not appear to meet modern safety standards for an emergency escape or a rescue opening from a sleeping room. Evaluate your risk exposure, correcting or making contingency measures as needed. Consider this area for appropriate upgrade or improvement.
Refurbish Before Painting
Refurbish before painting windows. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged areas, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
Window List
Windows needed correction when inspected. Windows were ready for corrections. Window conditions observed appear below in a bulleted list below. Check all windows correcting as needed for function and safety.
- Some window operation could be improved.
- Some window locks needed correction.
- Failing paint was observed.
Stairs/Railings Interior
Stairs/Railings Interior
Diagram: Correction Needed Railing
Railings were ready for upgrade: Railing for stairs to second floor
GARAGE
GARAGE
GARAGE TYPE: Attached
Garage Floor Location: At Ground
Garage Restrictions: Stored Items
Stored items were present at garage when it was inspected limiting view and access to some areas of garage.
Garage Separation from Living Space: Drywall Present Ceiling/Wall
Drywall was observed installed on ceiling framing and the wall framing that separated the garage and living space.
Should a fire occur at an attached garage area, properly installed drywall on framing, where needed, can offer some assistance to slow the spread of fire and smoke from the garage area to living areas. Properly maintain this area as needed.
Garage Floor: Floor Cracks Multiple
________________________________________________________________________________________________________________________________________________________________
GARAGE OVERHEAD DOOR: One Installed
Overhead Door Insulation: Not Insulated, Heated Area Over Garage
Heated space was observed above garage area. Garage overhead door was not insulated.
Garage overhead doors are typically the largest opening in a building. Installing insulated garage overhead doors may lower utility costs as well help make the garage and the heated living space above the garage area less drafty. Consider this area for appropriate improvement or upgrade.
Overhead Door Operation: Tested Using Operator
________________________________________________________________________________________________________________________________________________________________
GARAGE OVERHEAD DOOR OPERATOR: Testing Garage Overhead Door Operators
Testing Electric Operators for Garage Overhead Doors
Garage overhead door operators require periodic maintenance to maintain safe operation. Electric overhead door operators are checked for function and safety when inspected.
Modern garage overhead door operators have two safety reversal means; contact reversal and non-contact reversal.
Contact reversal is when the garage overhead door hits an obstruction that should cause the operator to reverse for safety.
Non-contact reversal is when the electronic eyes detect an obstruction, without the garage overhead door hitting an object, that should cause the operator to reverse for safety.
The contact reversal of the garage door operator is tested using a 1.5 inch obstruction on the floor at the center point of the overhead door. If the contact reversal requires correction, this is typically accomplished by a simple adjustment on the operator but other corrections could also be necessary. See overhead door operator owners manual for additional details.
If the electronic eyes area installed properly, the non-contact reversal is tested by obstructing the path between the electronic eyes while the operator is closing the garage overhead door. The installation height of the electronic eyes varies slightly by manufacture. Most manufacturers typically advise installing the electronic eyes no more than six inches above the floor at the overhead door track. If the electronic eyes are out of alignment, the operator will not close the garage overhead door without pushing and holding the wired, wall mounted, push-button until the garage overhead door is fully closed. If the electronic eyes require adjustment, this is typically accomplished by remounting or correcting the aim of the electronic eyes but other corrections could also be needed. See overhead door operator owners manual for additional details.
Electronic Eyes / Non Contact Reversal: Eyes Functional
Attached Garage Overhead Door Operator
Overhead door operator, non contact reversal means, electronic eyes, tested functional.
Contact Reversal: Contact Failed
Attached Garage Overhead Door Operator
Overhead door operator contact reversal means failed pinning an obstruction. It is not uncommon for the garage overhead door operators to require minor adjustment periodically. See overhead door operator owners manual for how to adjust the operator force for correct function. Correct as needed now for improved safety.
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following built-in kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area: Main Level
Kitchen
Countertop: Granite
- Serviceable, fulfilling its function
Cabinets: Wood
- Some wear noted, recondition to your standard
Floor Covering:
- Some wear noted, recondition to your standard
- Flooring was not level. Consider for correction.
Sink: Double Bowl Stainless Steel
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
Disposal: Present and appeared functional
Dishwasher: Present and ran through a normal cycle without incident
Range: Range (Electric Top/Oven)
Present and On/Off Tested functional
Microwave: Present and On/Off Tested functional
Kitchen Exhaust: Questionable installation observed. See Summary of report.
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Exhaust at Microwave
The deep cabinet above the microwave restricted the exhaust opening at the top of and towards the front of the microwave, which is designed for ductless exhausting. Proper correction is recommended. A competent, qualified contractor capable of reading and following the installation instructions should properly correct the microwave exhaust installation as needed for function and safety.
Multiple corrections are possible to improve the condition or to prevent damage to the cabinet or possibly the exhaust fan.
Some options are:
- It is possible to build a proper structural spacer at least 4" deep that would be attached between the wall behind the microwave and the microwave itself so that the microwave exhaust would properly extend beyond the cabinet front.
- Consider discontinuing use of exhaust fan altogether. If the exhaust fan comes on automatically with microwave use, then consider discontinuing the use of microwave and exhaust altogether.
- Consider replacing the microwave with one that exhausts out the front rather than the top.
- Consider replacing or modifying the cabinet above the microwave to prevent the cabinet from obstructing the exhaust.
Refer to installation instructions. Properly correct as desired to meet your needs, making the system fully functional and safe.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom
Full Bathroom
Location Full Bathroom: Upstairs
Bathing Area: Combination tub and shower
- No leaks were observed around the faucet, and the water containment area appeared serviceable.
- The shower was run only briefly as no shower curtain/door was present.
Hand Washing: Two basins in vanity
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
- Signs of past leakage were observed. Maintain the area to meet your needs.
Toilet: Water tank type
- No leaks were observed around the toilet, and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
Floor Covering: Tile
- Some wear noted, recondition to your standard
Bathroom
Full Bathroom
Location Full Bathroom: Main Level attached to a bedroom
Bathing Area: Shower
- No leaks were observed around the faucet, and the water containment area appeared serviceable.
- Properly maintain tile work to meet your needs.
Hand Washing: Two basins in vanity
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
- Signs of past leakage were observed. Maintain the area to meet your needs.
Toilet: Water tank type
- No leaks were observed around the toilet, and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
- Multiple fans were present and appeared to be operative.
Floor Covering: Tile
- Some wear noted, recondition to your standard
Bathroom
Half Bathroom
Location 1/2 Bathroom: Main Level Left
Hand Washing: Vanity with basin
- No leaks were observed at the faucet, the visible supply lines, or the waste drain beneath the sink.
Toilet: Water tank type
- No leaks were observed around the toilet, and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
Floor Covering: Tile
- Some wear noted, recondition to your standard
LAUNDRY
Laundry Connections
Laundry: Connections Available
Clothes washer and dryer connections were available.
Laundry appliances were not observed connected to the laundry connections during the inspection. Laundry faucets are not operated when the basin beneath the faucets is inadequate to contain the faucet flow without a hose being connected to the faucets. Verify your clothes dryer exhaust is functional, safe, and properly installed to meet the requirements of the clothes dryer manufacturer.
PLUMBING
Supply Piping
Supply Piping: Copper visible, other materials not viewed could be present
Water Flow at Supply Piping: Adequate
Adequate functional supply water flow was observed during inspection for water outlets operated.
Waste Piping
Waste Piping: Functional Flow Plastic
Material: Plastic
Functional waste water flow observed during inspection for water outlets operated.
Apparent Vent Piping
Plastic - No Adverse
Material: Plastic
No adverse conditions were observed, maintain to meet your needs.
Exterior Hose Faucets
Water Heater
Water Heater
Access: Area Not For Storage
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior-type areas have contingency measures installed to mitigate expected leakage or rupture of the water heater.
Such measures would collect and drain unwanted water to the exterior to prevent damage to interior finishes. Consider upgrading the water heater installation to help reduce unnecessary damage when the water heater leaks.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Present
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Unknown
Plumbing Supply Piping
A plumbing system pressure reducer was not located.
Verify location of installed pressure reducer or add as needed, if needed.
________________________________________________________________________________________________________________________________________________________________
Property Owner - Plumbing Supply Piping - MAIN WATER SHUT OFF VALVE - Apparent Location - Note Such Valves are Not Operated : Water Shut off Not Observed, unknown if present
CENTRAL SYSTEM
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served: System served upstairs area
Brand Furnace: U.S. Alumacoil / Location: Attic
Size: 2 ton / Year of Manufacture: 2022 / Fuel: Electric Heat Pump
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Goodman / Location: Exterior
Year of Manufacture: 2022 / Fuel: Electric
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Gravity drain piping - service annually
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Functional
________________________________________________________________________________________________________________________________________________________________
Heat Pump Single Fuel: Warm Day Backup Functional
Electric Heat Pump System - Backup heating was operated on a warm day.
For heating function, the electric single fuel heat pump system was operated only in the back up heating mode due to warmer outdoor ambient air temperature. Backup heating was briefly operated on heat pump. System engaged and was found to be functional.
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served:
Brand Furnace: U.S. Alumacoil / Location: Garage
Size: 2.5 ton / Year of Manufacture: 2022 / Fuel: Electric Heat Pump
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Goodman / Location: Exterior
Year of Manufacture: 2022 / Fuel: Electric
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Condensate pump was present, service annually
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Functional
Condensate Pan: Leak Pan Not Present Near Finished Area
Cooling System System served main level
Condensate leak pan was expected and not present. Cooling system evaporator coils installed adjacent to finished living space should have a properly installed condensate overflow leak pan to help minimize damage to finished areas when the system malfunctions. A properly installed float switch should be present at the overflow pan to switch off the condensing unit when the condensate drain becomes clogged or a separate drain should be present for the overflow pan that drains directly to an exterior area. Consider having a qualified competent heat/cool contractor properly correct area to control unnecessary preventable damage.
________________________________________________________________________________________________________________________________________________________________
Heat Pump Single Fuel: Warm Day Backup Functional
Electric Heat Pump System - Backup heating was operated on a warm day.
For heating function, the electric single fuel heat pump system was operated only in the back up heating mode due to warmer outdoor ambient air temperature. Backup heating was briefly operated on heat pump. System engaged and was found to be functional.
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served (if present), shade, climate zone, as well as the size, number, and placement of windows, must be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the installed central heating and cooling equipment.
Properly maintain the ductwork system to meet your comfort needs and ensure the system operates efficiently.
Space Heating
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment, and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment typically consists of one or more installed breaker panels, with branch wiring extending to all equipment, receptacles, lighting outlets, and devices, such as light switches. The inspection report focuses on wiring operating between 100-250 Volts. While the system's Amperage and Voltage are recorded, it is not measured during the inspection. Most low-voltage wiring is excluded from the performed inspection. Low-voltage items, such as heating and cooling thermostats, are used to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify that each lamp or bulb is suitable for the installed lighting fixture. The inspector recommends reviewing the bulb or lamp installations for each fixture, making corrections as needed for safety and proper function. Common errors include installing 100-watt bulbs in fixtures rated for 60-watt maximum bulbs, and using interior-rated bulbs in exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. A competent, licensed electrical contractor should correct electrical installation issues and address any functional issues that require correction. Most, if not all, electrical corrections should be considered a safety concern.
Electrical Service
System Amperage and Voltage, identified but not measured: 200 Amps - 120/240 Volts
Electrical Service Type: Underground
Access: Electrical Service Remove Vegetation, Electrical Service Routine Working Access, Service Not Identified But Evaluated
Electrical Service
Observed electrical service should have unobstructed, dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel. This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to electrical service.
MAIN PANEL
Main Electrical Panel
Service Entrance Conductors: Aluminum, Stranded
Index: Index, Vague
Electrical panel directory was ready for correction. Properly index or label each electrical panel circuit as needed for clarity and safety.
Enclosure: Screws, KO Open
Wiring: Remark White 240V Breaker
Wiring: Relocate Low Voltage Wiring
Breaker: Breaker COOLING Too Large
Cooling unit serving upstairs area was rated Max 15 Amp overcurrent device and a 20 Amp breaker was installed. Electrical breaker for installed central cooling unit was larger than allowed on the name plate of the cooling equipment. Install proper size overcurrent device for cooling unit as needed for safety and to protect the cooling equipment.
Main Breaker Panel Garage
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
Branch Wiring
Material: Copper
Wiring Method: Non Metallic Sheathed Cable
Improperly Terminated, Improper Wiring
Branch Wiring
Improperly terminated wiring was observed in garage between furnace and water heater. Photo Provided
Some exposed loose ends of wiring could not be visually confirmed as being properly disconnected from all electrical systems. Properly terminate exposed wiring ends by adding junction boxes, wire nuts, and covers where needed.
AFCI
AFCI Residential
What is Arc Fault Circuit Interrupter (AFCI) Protection?
AFCI protection is designed to break the electrical circuit when it detects electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Most, but not all, homes will have a need for additional AFCI protection based on varied municipal enforcement and the numerous changes for which areas require AFCI protection. Evaluate your risk exposure. Consider adding AFCI protection where needed for improved safety, particularly where construction was completed 2002 or later.
Modern Locations Where AFCI Protection is Known to Improve Safety:
Dwelling Units. All 120-volt, single-phase, 10-, 15-, and 20-ampere branch circuits supplying outlets or devices installed in the following locations:
Kitchens,
Family Rooms,
Dining Rooms,
Living Rooms,
Parlors, Libraries,
Dens,
Bedrooms,
Sunrooms,
Recreation Rooms,
Closets,
Hallways,
Laundry Areas,
or similar areas.
Testing AFCI Function
The inspector uses push button at AFCI breakers, where installed, to confirm AFCI protection trips. Once tripped, the inspector checks indexed electrical circuits to determine where AFCI protection is present or missing.
Obvious locations lacking AFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired AFCI receptacles or breakers are listed in the summary of the report. Evaluate your risk exposure.
No AFCI Built 2002 or Later
No AFCI protection was observed at inspected property. Consider modernizing electrical installation adding AFCI protection for improved electrical and fire safety. If installation of AFCI protection is desired, consult a competent electrical contractor.
GFCI
GFCI Residential
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Dwelling Units.
(A) Dwelling Units
All 125-volt through 250-volt receptacles installed in the following locations and supplied by single phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.
(3) Outdoors
(4) Crawl spaces - at or below grade level
(4) Basements
(5) Kitchens
(6) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(7) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Boathouses
(9) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(10) Laundry areas
(12) Indoor damp and wet locations
Some exceptions apply, see current standard for a list of exceptions.
(B) Pertains to Other Than Dwelling Units
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
(F) Outdoor Outlets. For dwellings, all outdoor outlets, including outlets installed in the following locations, and supplied-by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, shall be provided with GFCI protection:
(1) Garages that have floors located at or below grade level.
(2) Accessory buildings
(3) Boathouses
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Some
Some GFCI protection was present. Multiple areas would benefit from adding further GFCI protection. Consider modernizing electrical installation adding this shock protection, where missing, for all electrical areas where GFCI protection is known to improve safety. If installation of additional GFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
Receptacle Outlets
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Multiple electrical receptacles were observed loose.
- Properly correct loose electrical receptacles where needed.
- Some electrical receptacle junction boxes were loose. Properly correct where needed.
A competent electrical contractor should check all receptacles, making them functional and safe where needed.
Lighting/Ceiling Fans
Lighting/Ceiling Fans
Correct Lighting Where Needed
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were improperly installed.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
Switches Erroneous
Switches
The inspector was unable to determine the function of all switches present. Switches may operate flood lights, receptacles, or other items. They may also be an unused extra switch.
Smoke Alarms
Smoke Alarm Installation: Where Should Smoke Alarms be Installed?, Additional Smoke Alarms Recommended
Depending on the age and location of the home, installation of smoke alarms are either recommended or required for improved safety.
Modern smoke alarm systems typically are hardwired to the electrical system and will have battery backup so that they will function when the power is off to the building. Modern smoke alarm systems typically have all smoke alarms interconnected so that when one alarm sounds then all smoke alarms will sound simultaneously. This is useful for heavy sleepers and in larger homes.
Modern smoke alarm systems typically have smoke alarms installed at the following locations:
- In the immediate vicinity outside sleeping areas
- Inside sleeping areas
- At least one per floor level including basements
- Near stairs
- In unfinished basements
- (some installations will require additional smoke alarms)
It is important to note that a single smoke alarm can satisfy multiple areas if carefully placed.
It is common to have a single smoke alarm near the top of the stairs and just outside multiple sleeping areas.
Properly maintain smoke alarm system as needed for life safety.
Regarding Testing Smoke Alarms:
Test smoke alarms weekly to ensure proper function for life safety. Replace batteries when needed. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
The inspector does not test smoke alarms. For safety, the inspector only accesses smoke alarms from the installed flooring. To prevent damage, the inspector does not remove smoke alarms or open smoke alarm covers.
Smoke alarms were not present for all areas where now recommended or required.
Installation of additional smoke alarms is recommended.
- Inside sleeping room
- Outside sleeping area
- Near Bottom of Stairs
Evaluate your risk exposure. Upgrade smoke alarms to meet your needs and for life safety.
Read and follow the smoke alarm manufacturer installation and operating instructions.
Contact your local Fire Marshal if need be.
Battery Removed, Irregular Location, Smoke Alarm Removed
Battery was observed removed from smoke alarm. Install battery and test to ensure the unit is working properly. Properly correct as needed for function and safety.
Irregular smoke alarm location observed. Typically smoke alarms are mounted on ceilings at least 4" from a wall or when mounted on walls they should be between 4-12" from ceiling. Additionally, smoke alarms should be three feet from duct supply vents and doorways to kitchens or bathrooms. Refer to installation instructions properly correcting where needed.
SMOKE ALARM BELOW CEILING
- Smoke alarm at wall was not 4-12" below upper ceiling.
STRUCTURE
Attic Access
Attic Access: Door to Side attic area
Attic Access: Floored
Attic area viewed from areas where secured, floored, continuous, walkway was present that had sufficient height to be walked. Some areas of attic may not have been viewed.
Attic Area
Roof Framing
Framing: Rafters, Wooden
Sheathing: OSB
Roof Framing: Older Typical
Original framing, where visible, was observed typical for age of structure and may not meet current building standards. Monitor area periodically and make corrections if condition changes.
Ceiling Framing
Ceiling Framing: Wood
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector.
Wall Framing
Underfloor Access
Basement: Finished
Finished areas prevented the view of structural components, so the inspector did not observe structural areas. Concealed areas were not part of the inspection performed.
Underfloor Description
Attributes: Basement
Underfloor Area
Access:
- Basement walked
Construction Type:
- Basement - Finished
Foundation:
- Concrete Block or poured in place concrete
Columns or Piers:
- Load Bearing Wall
Floor Structure:
- Floor Joists - Not Observed
- Beam - Not Observed
- Subfloor - Not Observed
INSULATION
Above Ceiling Insulation
Recommended Insulation, Insulation Photo
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Insulation Type: Blown In
Observed Insulation Approximate Depth: R - 30, R - 19
Wall Insulation
Insulation: Roll batt insulation was observed where visible in the attic.
MOISTURE
Garage
Garage: Moisture Stains Observed Dry
Dry moisture stains were observed. Stains are evidence of a prior undesirable moisture condition. Monitor area to verify cause of stain is not still present. Further evaluation may be needed if cause of stains persists. Properly correct cause of stain if needed. Properly repair affected areas as needed.
- Dry moisture stains observed at garage near water heater.
Interior Moisture Signs
Interior: Moisture Stains Observed Dry
Dry moisture stains were observed. Stains are evidence of a prior undesirable moisture condition. Monitor the area to verify that the cause of the stain is not still present. Further evaluation may be needed if the cause of the stains persists. Properly correct the cause of the stain if needed. Properly repair affected areas as needed. Some affected areas may be concealed and are not part of the inspection performed.
- Dry moisture stains observed at living room ceiling near sky light.
- Dry moisture stains observed at living room right wall.
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Ridge Roof Vent
Attic Intake Vents: Soffit Vents Where Installed
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof
Common Limitations: Architectural Design Irregular
Roof Style: Multi Plane
Approximate Age of Roof Covering: Appeared original to construction date
Roofing Material: Composition Dimensional Shingle
Consider Replacement Older Roofing
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles were observed to be improperly installed. Refer to the installation instructions, and properly correct where needed.
- Low-sloping roof area with a pitch less than 2:12 was observed improperly covered with roofing shingles.
- Some shingles observed damaged.
- Some shingles observed worn.
- Temporary repairs observed. Execute permanent corrections where needed.
- Properly correct protruding nails where needed and replace shingles damaged by protruding nails.
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Some kick out flashings appeared omitted.
Consider replacement of older roofing.
Weigh your options for repairing roofing now knowing that you should replace it in the near future with the option of proper complete replacement now. Considering that a properly replaced roofing system may last up to three decades it may make better sense to replace the roofing correctly now rather than to repair an older roof system that will have to be replaced soon anyway.
Gutters and Downspouts
Gutter and Downspout Materials: Metal
Best Time to Replace
The best time to replace guttering is while you are having the roof covering replaced.
Observation: Screens
Downspout: Under
Gutters: Replace or Repair
Skylights
Multiple Skylights Observed
Maintain Instructions not reviewed, Replace/Remove when reroofing
Properly maintain skylight installation to meet your needs and prevent unwanted water entry. Review of skylight installation instructions is not part of this inspection.
SIDING and TRIM
Siding - Cement Fiber
Siding Irregularities: Common Irregularities
Cement Fiber Siding/Trim -
Typical siding installation irregularities were observed. Monitor siding installation budgeting corrections when necessary. When corrections are performed, refer to the installation instructions and best installation practices, and correct as required.
Siding Irregularities: Too Close to Roofing, Too Close to Pavement and Ground, Blocking and Flashing, Joint Treatment
Cement Fiber Siding/Trim -
Siding/Trim should be 1-2" away from roofing shingles to facilitate shingle replacement and to prevent siding from wicking moisture from roofing causing damage to siding and adjacent areas. Monitor siding installation budgeting corrections as needed. Consider upgrading area either before painting or when replacing roofing.
Cement Fiber Siding/Trim -
The inspector noted that portions of the siding or trim were too close to ground level, making the siding or substrate subject to damage. Siding and untreated substrate should be a minimum of 6" above soil and 1-2" above pavement. Properly provide separation at siding/trim and untreated substrate from soil and pavement. If it is not cost effective to lower the soil grade or raise the siding and substrate area then you should budget periodic replacement of affected areas.
Cement Fiber Siding/Trim -
The inspector noted that blocking and flashing details did not meet the Best Practices - Installation Guide for all areas. These areas should be considered for proper correction now. Closely monitor areas if not correcting blocking and flashing details now. Budget immediate correction should negative consequences occur due to a lack of proper blocking and flashing.
Cement Fiber Siding/Trim - Joint Treatment for cement fiber siding.
It is recommended that siding butt seams not be caulked. Flashing is preferred over caulk at butt seams. It is challenging to add flashing after the siding is installed, and it may not be cost-effective. If proper flashing installation is cost-prohibitive, then use of a properly rated exterior caulk may be necessary, albeit less desirable. Properly maintain siding as needed to prevent unwanted water damage.
Flashing behind butt joints provides an extra level of protection against the entry of water at the joint. James Hardie recommends 6 in. wide flashing that overlaps the course below by 1 in. Some local building codes may require a different size flashing. Joint-flashing material must be durable, waterproof materials that do not react with cement products. Examples of suitable material include finished coil stock and code-compliant water-resistant barriers. Other products may also be suitable.
- Flashing was not visible at some vertical edges where siding planks butt up against one another.
Siding: Corrections Needed
Exterior siding was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Physical Damage Observed
- Loose Siding Observed
- Trim Was Missing at Areas
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance. Affected adjacent areas that are concealed or not readily accessible are not part of the inspection performed.
Siding - Concrete Tile
What is Concrete Tile Siding?
Concrete Tile Siding, also known as Adhered Concrete Masonry Veneer or Manufactured Masonry Veneer, is a non structural, light weight concrete product that is not made of natural stone. Concrete tile siding resembles stonework because real stone are used to make castings that are filled with light weight concrete and are stained to appear similar to natural stone. Concrete tile siding is absorbent and requires a proper moisture management system be in place before applying the concrete tile to exterior areas. Since the moisture management system is beneath the concrete tile, after the tile are installed the moisture management system is no longer readily visible. The best time to inspect the moisture management system is during installation. Most adhered concrete tile installations should follow the Masonry Veneer Manufacturers Association Installation Guide and Detailing Options for Compliance with ASTM C1780. ACMV.
Irregular Monitor
Concrete Tile Siding
Common installation irregularities were observed. Monitor siding installation budgeting corrections when necessary. Refer to installation instructions and best installation practices, correcting where needed, when performing repairs. Maintain or upgrade this siding to meet your needs.
- Siding observed too close to Soil
- Irregular transition was observed at dissimilar materials
Siding - Vinyl
Vinyl Eaves with Metal Trim
Trim
Trim Material: Wood where installed
Trim: Corrections Needed
Exterior trim was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Failing Paint Observed
- Physical Damage Observed
- Rot Observed
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance. Affected adjacent areas that are concealed or not readily accessible are not part of the inspection performed.
LOTS and GROUNDS
Driveway
Walkway
Walkway: Recondition, Serviceable Cracked
Patio
Patio: Recondition
Patio was ready for reconditioning. Patio sloped towards foundation. Multiple cracks were present at patio. Properly correct or upgrade area to meet your needs.
Vegetation
Vegetation Maintenance
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Site
Site: Adjust Grade Basement
Some exterior grade work may improve stormwater runoff away from a basement-type foundation. Slope grade at least ten feet away from and around the structure so that water does not collect at the foundation. Be careful not to raise the grade at the structure above the foundation waterproofing.
Site: Verify Yard Dries
Verify yard dries out after 48 hours of no rain. Budget proper corrections should yard remain wet after rain has stopped for longer than 48 hours. If corrections are needed, then make proper corrections to protect dwelling and to your standard of care. Contact an appropriate competent professional if yard does not dry properly.
Retaining Wall
Retaining Wall
End of Report