How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Further Evaluation:Observations listed as further evaluation need a more extensive or technically exhaustive evaluation and warrant further investigation by a specialist. For areas where corrections may not be straight forward or where a proper plan should be developed to implement corrections, then further evaluation is recommended. To obtain further evaluation is to hire a specialist that is highly experienced in the repair or correction of a specific item or area. Some observations listed under other labels that also require further evaluation will appear under the other label only. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Routine Correction Needed:Observations listed as routine correction need repair or correction and are not unusual for the type and age property inspected. These routine items are typically not recurring and once properly corrected should not require repetitive correction. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- B-1 BATHROOM:
Location 1/2 Bathroom Main Level, Left, at Hall, Womens Restroom
Sink
Sink was loose.
Properly secure sink as needed to help prevent leaks. Faucet was not operated. Make functional and safe as needed.
- P-1 PLUMBING:
Location Main Level, Left
Sink Faucet
Leak observed at faucet handle.
Properly repair faucet for correct function.
Leak observed under sink.
Properly repair leak and any affected areas.
- P-2 PLUMBING:
Exterior Hose Faucet at Front
Exterior hose faucet was observed inoperative and loose when inspected.
Properly correct or replace as needed. Video Provided
- P-3 PLUMBING:
Water Heater Equipment Closet
Water heater relief valve should have discharge extension pipe that is installed so that valve and discharge piping drain completely.
Installed discharge pipe did not appear to be self draining. Properly correct water heater relief valve discharge pipe as needed for function and safety.
- P-4 PLUMBING:
Water Heater Equipment Closet
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater leak provisions were not installed.
- Pressure temperature relief valve discharge piping was not installed properly.
- CS-1 CENTRAL SYSTEM:
Cooling System: System served main level right area
Condensate leak pan was expected and not present beneath furnace.
Cooling system evaporator coils installed at, adjacent to, or above a finished living space should have a properly installed condensate overflow leak pan to help minimize damage to finished areas when the system malfunctions. A properly installed float switch should be present at the overflow pan to switch off the condensing unit when the condensate drain becomes clogged or a separate drain should be present for the overflow pan that drains directly to an exterior area. Consider having a qualified competent heat/cool contractor properly correct area to control unnecessary preventable damage.
- CS-2 CENTRAL SYSTEM:
Service walkway to furnace in attic was missing or incomplete. System served upstairs right area
Furnaces installed inside attic areas should have a secured 24" wide walkway and a 30" deep service platform running the length of the control side of the furnace to provide minimum reasonable access for maintenance of the furnace. Correction was needed for safety of service personnel and to reduce property owner liability exposure. Properly correct to meet your needs.
- CS-3 CENTRAL SYSTEM:
Cooling System: System served main level left area
Condensate leak pan was expected and not present beneath furnace.
Cooling system evaporator coils installed at, adjacent to, or above a finished living space should have a properly installed condensate overflow leak pan to help minimize damage to finished areas when the system malfunctions. A properly installed float switch should be present at the overflow pan to switch off the condensing unit when the condensate drain becomes clogged or a separate drain should be present for the overflow pan that drains directly to an exterior area. Consider having a qualified competent heat/cool contractor properly correct area to control unnecessary preventable damage.
- CS-4 CENTRAL SYSTEM:
Service walkway to furnace in attic was missing or incomplete. System served upstairs left area
Furnaces installed inside attic areas should have a secured 24" wide walkway and a 30" deep service platform running the length of the control side of the furnace to provide minimum reasonable access for maintenance of the furnace. Correction was needed for safety of service personnel and to reduce property owner liability exposure. Properly correct to meet your needs.
- CD-1 Central Ductwork:
Ductwork
Ductwork insulation observed in need of correction for some areas. Have a competent heating contractor check all ductwork properly correcting where needed.
- Ductwork insulation observed missing at rear access equipment closet.
- E-1 ELECTRICAL:
Electrical Service
Observed electrical service should have unobstructed, dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel.
This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to electrical service.
- E-2 ELECTRICAL:
Sub Breaker Panel Equipment Closet at Rear
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
- E-3 ELECTRICAL:
Sub Breaker Panel Upstairs
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
- E-4 ELECTRICAL:
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was not fully functional when inspected.
- Some lighting was inoperative when inspected.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
- R-1 ROOF:
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles observed damaged.
- Flashing appeared irregular at areas. Correct where needed.
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Numerous ceiling stains were observed
Further Evaluations
- M-1 MOISTURE:
Numerous dry moisture stains and damage was observed at interior areas. Representative photos provided.
- Obtain further evaluation of all interior areas to determine cause of moisture staining and damage at each area.
- Take steps to prevent recurrence.
- Properly cure all affected areas as needed including mold remediation if deemed needed after separate mold evaluation is performed by other parties,
- M-2 MOISTURE:
Further evaluation of apparent fungal growth observed at at equipment closet that is entered from right rear of building is needed before occupying building.
- A mold inspection in addition to the commercial building inspection was not ordered and is not part of this inspection.
- Sampling of area for mold determination by a certified lab was offered during inspection and was declined by client's wife.
- Sampling of area and lab analysis for mold determination prior to remediation is necessary to determine protocol needed for remediation.
- Air inside equipment closet communicates through to finished areas of building. Air samples are recommended of areas inside finished areas and at equipment closet to be compared to outdoor air and sent lab for analysis for mold determination prior to occupying building.
- Properly cure all undesirable moisture conditions.
- Obtain further evaluation for mold. A competent inspector should collect samples and submit for proper lab analysis for mold determination. Perform remediation measures as needed for health safety and to protect the building.
The Full Report
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Doors
Glazing/Glass
Windows
Stairs/Railings Interior
Stairs/Railings Interior
Not evaluated
UPSTAIRS PHOTOS
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Other Sink Area
Exterior Hose Faucets
Water Heater
Equipment Observed
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Home Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Commercial
Site Built
Approximate Square Footage: 4625
Approximate Year of Original Construction: 2011
Weather during the inspection: Cloudy
Ground/Soil surface conditions: Dry
Approximate Low Temperature During Inspection: 40[F]
Approximate High Temperature During Inspection: 50[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Building Empty
Building was empty of furnishings when inspected.
________________________________________________________________________________________________________________________________________________________________
Ceilings
Interior Ceiling Materials: Drywall, Open, Suspended Ceiling
Interior Ceiling Condition:
- Wear and damage noted.
- Recondition to your standard.
________________________________________________________________________________________________________________________________________________________________
Walls
Interior Wall Materials: Drywall
Interior Wall Condition:
- Wear and damage noted.
- Recondition to your standard.
________________________________________________________________________________________________________________________________________________________________
Flooring
Interior Flooring Materials: Wood, Carpet, Tile
Interior Flooring Condition:
- Wear and damage noted.
- Recondition to your standard.
Doors
Doors at Interior: Some door operation could be improved
Doors Correct as Needed
Doors at Interior
Properly correct interior doors to your standard and to meet your needs.
________________________________________________________________________________________________________________________________________________________________
Check All
Doors to Exterior
Check all doors to exterior properly making doors functional, secure and weather tight to meet your needs.
- Door operation could be improved. Properly correct door operation to meet your needs.
- Properly correct door hardware to meet your needs.
Glazing/Glass
Insulated glass was present.
Visibility Obscured
Obscured visibility was observed at insulated glass at some windows. Obscured visibility at insulated glass can be caused by failure of the seal between the layers of glass, failure of the UV protective film or other cause. Replacement of the glass is typically the best method to cure this problem. Check all areas. Properly replace or repair all obscured or damaged glass as needed.
Windows
Wood framed windows were present.
Screens
Window screens are not required on homes with central cooling system air conditioning. Install window screens where missing, if desired.
Window List, Wood Consider Upgrade, Consider Replacement
Windows needed correction when inspected. Windows were ready for corrections. Window conditions observed appear below in a bulleted list below. Check all windows correcting as needed for function and safety. Photos are representative.
- Some window operation could be improved.
- Some windows did not operate properly.
- Wood rot observed.
Wooden framed windows require more periodic maintenance than modern vinyl or metal windows. Properly maintain wooden framed windows to meet your needs. Consider upgrade to a more durable material, if less frequent maintenance is desired.
Consider replacement windows as a more cost effective long term solution than repairing existing windows now and performing future periodic maintenance.
Stairs/Railings Interior
Railing Serviceable, fulfilling its function: Railing for stairs to second floor
Stairs/Railings Interior
Diagram: Correction Needed Stairs
Stairs: Irregular, Uneven, Commercial Steep 7 1/2+"
The installed steps did not conform to modern standards for safe stairs. Use extreme caution when walking on these stairs now and consider upgrade to conforming stairs for safety.
Stairs Repair/Replace
Evaluate your risk exposure. Consider proper repair or replacement of steps and railings where needed now for safety and function.
Not evaluated
KITCHEN
Inspection Process
Not Present
The inspected property did not appear to have a functional kitchen. Evaluate your need. Install a functional kitchen if desired or necessary.
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following built-in kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom 1
Half Bathroom
Location 1/2 Bathroom Main Level, Right, at Hall, Mens Restroom
Hand Washing: Wall hung type
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Wear and damage observed. Budget reconditioning.
Bathroom 2
Half Bathroom
Location 1/2 Bathroom Main Level, Right, at Hall, Womens Restroom
Hand Washing: Wall hung type
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Wear and damage observed. Budget reconditioning.
Sink/Faucet: Waste (Mechanical Stopper)
Location 1/2 Bathroom Main Level, Right, at Hall, Womens Restroom
Sink
Mechanical stopper was in need of repair. Correct to meet your needs.
Bathroom 3
Half Bathroom
Location 1/2 Bathroom Main Level, Left, at Hall, Mens Restroom
Hand Washing: Wall hung type
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Wear and damage observed. Budget reconditioning.
Sink/Faucet: Waste (Mechanical Stopper)
Location 1/2 Bathroom Main Level, Left, at Hall, Mens Restroom
Sink
Mechanical stopper was in need of repair. Correct to meet your needs.
Bathroom 4
Half Bathroom
Location 1/2 Bathroom Main Level, Left, at Hall, Womens Restroom
Hand Washing: Wall hung type
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Wear and damage observed. Budget reconditioning.
Sink/Faucet: Waste (Mechanical Stopper)
Location 1/2 Bathroom Main Level, Left, at Hall, Womens Restroom
Sink
Mechanical stopper was in need of repair. Correct to meet your needs.
PLUMBING
Supply Piping
Supply Piping: Mostly PEX with Some Copper
Water Flow at Supply Piping: Adequate
Adequate functional supply water flow was observed during inspection for water outlets operated.
Waste Piping
Waste Piping: Functional Flow Plastic
Material: Plastic
Functional waste water flow observed during inspection for water outlets operated.
Apparent Vent Piping
Plastic - No Adverse
Material: Plastic
No adverse conditions were observed, maintain to meet your needs.
Other Sink Area
No Leaks
Location Main Level Right
Sink
No leaks were observed. The inspected faucet was run for longer than one minute. No leaks were viewed at the visible supply lines, faucet or the visible waste drain lines just beneath the sink.
Signs of past leakage observed. Maintain area to meet your needs.
Location Main Level, Left
Sink Faucet
Leak observed at faucet handle.
Properly repair faucet for correct function.
Leak observed under sink.
Properly repair leak and any affected areas.
Exterior Hose Faucets
Exterior Hose Faucet at Front
Exterior hose faucet was observed inoperative and loose when inspected.
Properly correct or replace as needed. Video Provided
Water Heater
Water Heater
Discharge Piping: Should Self Drain
Installation Issue: Leak Pan Drained to Interior
Water Heater
Leak pan was observed beneath water heater that drained to an interior area defeating the function of the leak pan. The leak pan should drain to an exterior area. Proper correction is recommended to prevent damage to interior areas should the water heater leak pan receive water such as from a water heater leak.
Water Heater Equipment Closet
Water heater relief valve should have discharge extension pipe that is installed so that valve and discharge piping drain completely.
Installed discharge pipe did not appear to be self draining. Properly correct water heater relief valve discharge pipe as needed for function and safety.
Water Heater Equipment Closet
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater leak provisions were not installed.
- Pressure temperature relief valve discharge piping was not installed properly.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Present
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Unknown
Plumbing Supply Piping
A plumbing system pressure reducer was not located.
Verify location of installed pressure reducer or add as needed, if needed.
________________________________________________________________________________________________________________________________________________________________
Property Owner - Plumbing Supply Piping - MAIN WATER SHUT OFF VALVE - Apparent Location - Note Such Valves are Not Operated : Water Shut off Not Observed, unknown if present
CENTRAL SYSTEM
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served: System served main level right area
Brand Furnace: Frigidaire by Nortek / Location: Equipment Closet / Fuel: Electric Heat Pump
Size: 4 ton / Year of Manufacture: 2010
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Frigidaire by Nortek / Location: Exterior / Fuel: Electric
Year of Manufacture: 2010
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Gravity drain for condensate
The inspector recommends annual servicing for all equipment ten years old and older.
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Below 60 Degrees
Cooling System Not Operated Cool Day
Outdoor temperature was below 60 degrees f. The central cooling system was not operated in cooling mode due to low exterior ambient temperatures. To test the cooling unit without causing possible damage to the compressor the ambient outdoor temperature should be above 60 degrees f.
Heat Pump Single Fuel: Cool Day Heat Pump Functional
Electric Heat Pump System - Heating functional cool day
For heating function, the electric single fuel heat pump system was operated in the normal heating mode and in the back up heating mode.
In normal heating mode, system engaged and was found to be functional.
Backup heating was briefly operated on heat pump. System engaged and was found to be functional.
Cooling System: System served main level right area
Condensate leak pan was expected and not present beneath furnace.
Cooling system evaporator coils installed at, adjacent to, or above a finished living space should have a properly installed condensate overflow leak pan to help minimize damage to finished areas when the system malfunctions. A properly installed float switch should be present at the overflow pan to switch off the condensing unit when the condensate drain becomes clogged or a separate drain should be present for the overflow pan that drains directly to an exterior area. Consider having a qualified competent heat/cool contractor properly correct area to control unnecessary preventable damage.
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served: System served upstairs right area
Brand Furnace: Goodman / Location: Attic / Fuel: Electric Heat Pump
Size: 2.5 ton / Year of Manufacture: 2022
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Goodman / Location: Exterior / Fuel: Electric
Year of Manufacture: 2023
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Condensate pump was present, service annually
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Below 60 Degrees
Cooling System Not Operated Cool Day
Outdoor temperature was below 60 degrees f. The central cooling system was not operated in cooling mode due to low exterior ambient temperatures. To test the cooling unit without causing possible damage to the compressor the ambient outdoor temperature should be above 60 degrees f.
________________________________________________________________________________________________________________________________________________________________
Heat Pump Single Fuel: Cool Day Heat Pump Functional
Electric Heat Pump System - Heating functional cool day
For heating function, the electric single fuel heat pump system was operated in the normal heating mode and in the back up heating mode.
In normal heating mode, system engaged and was found to be functional.
Backup heating was briefly operated on heat pump. System engaged and was found to be functional.
Service walkway to furnace in attic was missing or incomplete. System served upstairs right area
Furnaces installed inside attic areas should have a secured 24" wide walkway and a 30" deep service platform running the length of the control side of the furnace to provide minimum reasonable access for maintenance of the furnace. Correction was needed for safety of service personnel and to reduce property owner liability exposure. Properly correct to meet your needs.
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served: System served main level left area
Brand Furnace: Frigidaire by Nortek / Location: Equipment Closet / Fuel: Electric Heat Pump
Size: 4 ton / Year of Manufacture: 2010
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Frigidaire by Nortek / Location: Exterior / Fuel: Electric
Year of Manufacture: 2011
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Gravity drain piping - service annually
The inspector recommends annual servicing for all equipment ten years old and older.
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Below 60 Degrees
Cooling System Not Operated Cool Day
Outdoor temperature was below 60 degrees f. The central cooling system was not operated in cooling mode due to low exterior ambient temperatures. To test the cooling unit without causing possible damage to the compressor the ambient outdoor temperature should be above 60 degrees f.
Refrigerant Piping: Some Insulation Missing
Cooling system refrigerant piping needed additional insulation. Sections of the insulation on the compressor refrigerant lines appeared to be missing. These lines should be suitably insulated to prevent sweating lines from dripping moisture to finished areas and to improve efficiency of the cooling system.
________________________________________________________________________________________________________________________________________________________________
Heat Pump Single Fuel: Cool Day Heat Pump Functional
Electric Heat Pump System - Heating functional cool day
For heating function, the electric single fuel heat pump system was operated in the normal heating mode and in the back up heating mode.
In normal heating mode, system engaged and was found to be functional.
Backup heating was briefly operated on heat pump. System engaged and was found to be functional.
Cooling System: System served main level left area
Condensate leak pan was expected and not present beneath furnace.
Cooling system evaporator coils installed at, adjacent to, or above a finished living space should have a properly installed condensate overflow leak pan to help minimize damage to finished areas when the system malfunctions. A properly installed float switch should be present at the overflow pan to switch off the condensing unit when the condensate drain becomes clogged or a separate drain should be present for the overflow pan that drains directly to an exterior area. Consider having a qualified competent heat/cool contractor properly correct area to control unnecessary preventable damage.
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served: System served upstairs left area
Brand Furnace: Frigidaire by Nortek / Location: Attic / Fuel: Electric Heat Pump
Size: 3 ton / Year of Manufacture: 2011
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Frigidaire by Nortek / Location: Exterior / Fuel: Electric
Year of Manufacture: 2011
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Gravity drain piping - service annually
The inspector recommends annual servicing for all equipment ten years old and older.
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Below 60 Degrees
Cooling System Not Operated Cool Day
Outdoor temperature was below 60 degrees f. The central cooling system was not operated in cooling mode due to low exterior ambient temperatures. To test the cooling unit without causing possible damage to the compressor the ambient outdoor temperature should be above 60 degrees f.
Refrigerant Piping: Some Insulation Missing
Cooling system refrigerant piping needed additional insulation. Sections of the insulation on the compressor refrigerant lines appeared to be missing. These lines should be suitably insulated to prevent sweating lines from dripping moisture to finished areas and to improve efficiency of the cooling system.
________________________________________________________________________________________________________________________________________________________________
Heat Pump Single Fuel: Cool Day Heat Pump Functional
Electric Heat Pump System - Heating functional cool day
For heating function, the electric single fuel heat pump system was operated in the normal heating mode and in the back up heating mode.
In normal heating mode, system engaged and was found to be functional.
Backup heating was briefly operated on heat pump. System engaged and was found to be functional.
Service walkway to furnace in attic was missing or incomplete. System served upstairs left area
Furnaces installed inside attic areas should have a secured 24" wide walkway and a 30" deep service platform running the length of the control side of the furnace to provide minimum reasonable access for maintenance of the furnace. Correction was needed for safety of service personnel and to reduce property owner liability exposure. Properly correct to meet your needs.
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served, if present, shade, climate zone along with size, number and placement of windows have to be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the the installed central heating and cooling equipment. Properly maintain the ductwork system to meet your comfort needs and to allow system to operate properly.
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment is most often one or more installed breaker panels and the branch wiring runs to all equipment, receptacles, lighting outlets and devices such as the light switches. The inspection report focuses on wiring operating between 100-250 Volts. While system Amperage and Voltage is recorded, it is not measured during inspection. Most low voltage wiring is excluded from the performed inspection. Low voltage items such as a heating and cooling thermostat are operated in order to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify each lamp or bulb is appropriate for the installed lighting fixture. The inspector recommends that you review the bulb or lamp installations for each fixture correcting as needed for safety and function. Common errors include 100 watt bulbs installed in fixtures rated for 60 watt max bulbs and interior rated bulbs installed at exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. Most, if not all, electrical corrections should be considered a safety concern.
ELECTRICAL SERVICE
Electrical Service
Observed electrical service should have unobstructed, dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel.
This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to electrical service.
System Amps / Volts
System Amperage: 400 Amp
System Voltage: 120/240 Volts
MAIN PANEL
Main Electrical Panel
Service Entrance Conductors: Aluminum, Stranded
Panel Inspected
The electrical panel cover was removed from the electrical distribution panel. The interior components were viewed and found to be in satisfactory condition and appeared to be properly installed. No repairs were needed to electrical panel or interior components when inspected.
SUB PANEL
Sub Electrical Panel
Index: Index, Differentiate
Electrical panel directory was ready for correction. Properly index or label each electrical panel circuit as needed for clarity and safety.
Wiring: Remark White 240V Breaker
Breaker: Breaker COOLING Too Large, Breaker COOLING2 Too Large
Cooling unit serving main level Left was rated Max 45 Amp overcurrent device and a 50 Amp breaker was installed. Electrical breaker for installed central cooling unit was larger than allowed on the name plate of the cooling equipment. Install proper size overcurrent device for cooling unit as needed for safety and to protect the cooling equipment.
Cooling unit serving upstairs area left was rated Max 30 Amp overcurrent device and a 50 Amp breaker was installed. Electrical breaker for installed central cooling unit was larger than allowed on the name plate of the cooling equipment. Install proper size overcurrent device for cooling unit as needed for safety and to protect the cooling equipment.
Sub Breaker Panel Equipment Closet at Rear
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
SUB PANEL
Sub Electrical Panel
Index: Index, Differentiate
Wiring: Remark White 240V Breaker
Sub Breaker Panel Upstairs
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
GFCI
GFCI Commercial
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is designed to help reduce the risk of being shocked when using electricity in certain areas.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. Evaluate your risk exposure. Consider adding GFCI protection for 15 and 20 ampere electrical circuits where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety:
All 120V electrical receptacles for commercial buildings should now be GFCI protected.
Testing GFCI Function
The inspector uses an electrical tester at receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Receptacles OK
Using a ground fault circuit interrupter tester, GFCI protected electrical receptacles, where installed, were checked and indicated proper function.
GFCI Some
Some GFCI protection was present. Multiple areas would benefit from adding further GFCI protection. Consider modernizing electrical installation adding this shock protection, where missing, for all electrical areas where GFCI protection is known to improve safety.
Receptacle Outlets
Loose
Electrical Receptacle Outlets
One or more electrical receptacles were observed loose. Properly correct any loose electrical receptacles where needed for safety.
Cover Plates: Exterior
Electrical Receptacle Outlet
Properly install exterior rated receptacle cover plates where needed for safety.
Lighting/Ceiling Fans
Correct Lighting Where Needed
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
STRUCTURE
Attic Access
Attic Access: Door to Side attic area, Through Suspended Ceiling Tile
Roof Framing
Ceiling Framing
Ceiling Framing: Suspended ceiling with metal track framing was present for some areas.
Condition: No Adverse
No adverse conditions were observed for this area. Maintain this area to meet your needs.
Wall Framing
Wood
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector.
Underfloor Access
Slab: Finished Areas
Finished areas prevented view of structural components. Structural components were not observed by inspector at such areas.
Underfloor Description
Slab: On Grade
Underfloor Area
Access:
Slab construction no underfloor area present
Construction Type:
Concrete Slab on Grade
Foundation:
Poured in Place Concrete or Concrete Block
Columns or Piers:
Not Applicable
Floor Structure:
Concrete Slab Floor
Floor Insulation:
Not Applicable
INSULATION
Above Ceiling Insulation
Recommended Insulation
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Insulation Type: Roll or Batt
Observed Insulation Approximate Depth: R - 30, R - 19
Wall Insulation
Insulation: Roll batt insulation observed where visible at attic.
MOISTURE
Interior Moisture Signs
Numerous dry moisture stains and damage was observed at interior areas. Representative photos provided.
- Obtain further evaluation of all interior areas to determine cause of moisture staining and damage at each area.
- Take steps to prevent recurrence.
- Properly cure all affected areas as needed including mold remediation if deemed needed after separate mold evaluation is performed by other parties,
Further evaluation of apparent fungal growth observed at at equipment closet that is entered from right rear of building is needed before occupying building.
- A mold inspection in addition to the commercial building inspection was not ordered and is not part of this inspection.
- Sampling of area for mold determination by a certified lab was offered during inspection and was declined by client's wife.
- Sampling of area and lab analysis for mold determination prior to remediation is necessary to determine protocol needed for remediation.
- Air inside equipment closet communicates through to finished areas of building. Air samples are recommended of areas inside finished areas and at equipment closet to be compared to outdoor air and sent lab for analysis for mold determination prior to occupying building.
- Properly cure all undesirable moisture conditions.
- Obtain further evaluation for mold. A competent inspector should collect samples and submit for proper lab analysis for mold determination. Perform remediation measures as needed for health safety and to protect the building.
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Ridge Roof Vent
Attic Intake Vents: Soffit Vents Where Installed
ROOF
Roof Covering
Method of Roof Inspection: Viewed from ground with binoculars, Viewed from ladder at eave
Roof Style: Multi Plane
Approximate Age of Roof Covering: 12-14 Years
Roofing Material: Composition Dimensional Shingle
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles observed damaged.
- Flashing appeared irregular at areas. Correct where needed.
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Numerous ceiling stains were observed
Gutters and Downspouts
Gutter and Downspout Materials: Metal
Best Time to Replace
The best time to replace guttering is while you are having the roof covering replaced.
Downspout: Near
Gutters: Maintain
Properly maintain rain gutters to meet your needs.
SIDING and TRIM
Masonry Siding
Brick Veneer
Brickwork: Requires Maintenance, Replace/Repair
Brickwork
Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance.
Siding - Cement Fiber
Siding - Vinyl
Vinyl Eaves with Metal Trim, Vinyl Siding
Siding: Corrections Needed
Exterior siding/trim was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Vinyl Siding Was Ready to be Washed
What you should do.
- Siding was ready for routine maintenance such as washing and inspecting for damaged areas. Make proper corrections as needed.
LOTS and GROUNDS
Driveway
Walkway
Porch
Vegetation
Vegetation Maintenance
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Site
End of Report
Thank You Note
Thank you so much for trusting me to perform your inspection!
Please reach out if I may assist you further.
Roger Williamson
423-301-1000
HomePro Inspection.com