How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Further Evaluation:Observations listed as further evaluation need a more extensive or technically exhaustive evaluation and warrant further investigation by a specialist. For areas where corrections may not be straight forward or where a proper plan should be developed to implement corrections, then further evaluation is recommended. To obtain further evaluation is to hire a specialist that is highly experienced in the repair or correction of a specific item or area. Some observations listed under other labels that also require further evaluation will appear under the other label only. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Routine Correction Needed:Observations listed as routine correction need repair or correction and are not unusual for the type and age property inspected. These routine items are typically not recurring and once properly corrected should not require repetitive correction. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- K-1 KITCHEN:
Kitchen Cooking Exhaust
Kitchen ducted exhaust fan appeared to discharge to the attic area.
For safety this unit should properly exhaust directly to the exterior or be properly converted to a ductless or recirculating exhaust. Refer to the installation instructions. Properly correct or replace kitchen exhaust as needed for function and safety. Correct any affected areas, if needed.
- K-2 KITCHEN:
Cooking Exhaust Inoperative
The kitchen exhaust system was inspected and found inoperative when using the normal operating controls.
Properly put the system back in service correcting as needed for function and safety.
- B-1 BATHROOM:
Location Full Bathroom Upstairs, En Suite, attached to a bedroom
Sink
Sink observed damaged when inspected.
Proper replacement of the sink is recommended.
- B-2 BATHROOM:
Location Full Bathroom Basement
Sink
Sink was loose.
Properly secure sink as needed to help prevent leaks.
- B-3 BATHROOM:
Location Full Bathroom Basement
Sink
Leak observed under sink.
Properly repair leak and any affected areas.
- B-4 BATHROOM:
Location Full Bathroom Basement
Area: Bathing Area
Shower finish was observed damaged.
Properly repair to meet your needs and prevent leakage.
- B-5 BATHROOM:
Full Bathroom at Basement
Ductwork for multiple bathroom exhaust fans were observed connected together exhausting to a single discharge outlet.
Typically each fan requires an independent discharge outlet. Refer to installation instructions for each fan properly correcting as needed for function and safety. Also, clothes dryer exhaust should not be connected to bathroom exhausts.
- B-6 BATHROOM:
Location Full Bathroom Basement
Properly put this bathroom back in service.
- L-1 LAUNDRY:
Clothes dryer exhaust observed irregular as it was connected to two exhaust fans at basement bathroom.
Properly correct clothes dryer exhaust to meet manufacturer requirements.
- G2-1 Gas:
Furnace System served majority of home
Gas Piping was ready for proper correction.
Properly correct gas piping where needed.
- Sediment trap for gas piping to furnace was not visible.
- GAF-1 Gas Appliance Flue:
Water Heater
Gas appliance metal flue needed correction.
Gas appliance metal chimney flue appeared too close to combustible roof decking and should be properly corrected for safety. A single wall metal flue generally needs six inches clearance away from combustibles while a double wall metal flue will typically only need one full inch clearance away from combustibles. A competent heating technician should further evaluate and properly correct gas appliance metal flue as needed for safety and function.
- E-1 ELECTRICAL:
Main Breaker Panel Basement
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
- E-2 ELECTRICAL:
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
- E-3 ELECTRICAL:
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Some electrical receptacles were observed improperly installed.
- Older two wire electrical receptacle circuits observed in need of correction.
- Some electrical receptacles were observed damaged.
- Install proper cover plates where needed at interior.
An electrical contractor should check all receptacles making functional and safe where needed.
- E-4 ELECTRICAL:
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were improperly installed.
- Some light fixtures were damaged.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
Further Evaluations
- P-1 PLUMBING:
Multiple plumbing corrections were needed.
A Licensed Competent Plumbing Contractor should further evaluate entire plumbing system. Properly repair or replace plumbing system as needed to make system fully functional and safe.
- S-1 STRUCTURE:
Foundation Warrants Further Evaluation by a Specialists
A competent qualified contractor, foundation specialist or State licensed professional engineer should further evaluate entire foundation system and all supports determining corrective measures needed, take action to prevent recurrence and properly repair affected areas where needed. Making corrections for areas where needed now would help reduce predictable unnecessary settlement or possible collapse of structure.
The Full Report
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Doors
Glazing/Glass
Windows
Stairs/Railings Interior
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Exterior Hose Faucets
Water Heater
Equipment Observed
Plumbing Other
ELECTRICAL
Electrical Inspection
Electrical Service
MAIN PANEL
Branch Wiring
AFCI
GFCI
Receptacle Outlets
Two Wire Receptacles
Three Wire Receptacles
Lighting/Ceiling Fans
Lighting/Ceiling Fans
Switches
Smoke Alarms
Bond
STRUCTURE
Attic Access
Roof Framing
Ceiling Framing
Wall Framing
Underfloor Access
Underfloor Description
Foundation
Floor System
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Home Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Single Family Home
Site Built, Possible unfinished basement area converted to finished living space.
Approximate Square Footage: 2416
Approximate Year of Original Construction: 1964
Weather during the inspection: Clear
Ground/Soil surface conditions: Dry
Approximate Low Temperature During Inspection: 50[F]
Approximate High Temperature During Inspection: Above 60[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Furniture, Property, Rugs, Excess Stored Items
Access and visibility was limited at interior areas as furnishings, personal property and area rugs were present.
Access and visibility at interior areas had greater restrictions due to excess stored items. Concealed conditions may be present. All interior areas should be reinspected after reasonable access is provided. Make proper corrections as needed after having all interior areas reinspected. Report photos are representative and are not intended to show all areas where access and visibility were restricted.
________________________________________________________________________________________________________________________________________________________________
Ceilings
Patched Areas, Low Ceiling
Patched ceiling areas were viewed. The inspected area had visible patched areas. Verify that the cause requiring the area to be patched has been resolved. Monitor area and correct further if needed.
________________________________________________________________________________________________________________________________________________________________
Walls
Interior Wall Materials: Drywall, Paneling
Interior Wall Condition:
- Wear noted, properly recondition to meet your needs
________________________________________________________________________________________________________________________________________________________________
Flooring
Not Level Older
Flooring
Some flooring appeared out of level. This is not uncommon for older structures. Monitor area correcting to meet your standards.
Doors
Doors Replace Repair
Replace, repair or upgrade interior doors to meet your needs. Properly correct any affected adjacent areas, if present.
________________________________________________________________________________________________________________________________________________________________
Doors to Exterior: Hollow
Glazing/Glass
Single pane glass was present.
Windows
Metal framed windows were present.
Escape and Rescue
Consider upgrade for escape and rescue window openings.
Window for one or more possible sleeping areas did not appear to meet modern safety standards for an emergency escape or a rescue opening from a sleeping room. Evaluate your risk exposure correcting or making contingency measures as needed. Consider this area for appropriate upgrade or improvement.
Older Windows, Original Windows
Older windows often have been neglected and may not operate as intended. Check all windows properly correcting where needed.
The building appeared to have at least some of the original windows installed during construction. Windows are now available that are more efficient to reduce energy usage and improve comfort level inside home. Consider upgrading if desired.
Stairs/Railings Interior
Diagram: Older Railing & Stairs
Railings and Stairs at older home as expected, did not meet current safety standards. Railings and stairs were ready for modernization for improved safety. Evaluate your risk exposure. Consider proper repair or replacement of stairs and railings where needed now for safety and function.
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following built-in kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area: Upstairs
Kitchen
Countertop: Laminate
- Some wear noted, recondition to your standard
Cabinets: Wood and wood composition, painted
- Some wear noted, recondition to your standard
Floor Covering: Tile
- Some wear noted, recondition to your standard
Sink: Double Bowl Stainless Steel
- No leaks were viewed at faucet or visible supply lines or waste drain just beneath the sink.
- Signs of past leakage observed. Maintain area to meet your needs.
Disposal: Present and appeared functional
Dishwasher: Present and ran through a normal cycle without incident
Range: Cooktop Gas and Separate Electric Double Oven
Present and On/Off Tested functional
Microwave: Portable unit not evaluated
Kitchen Exhaust: Questionable installation observed. See Summary of report.
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Kitchen Cooking Exhaust
Kitchen ducted exhaust fan appeared to discharge to the attic area.
For safety this unit should properly exhaust directly to the exterior or be properly converted to a ductless or recirculating exhaust. Refer to the installation instructions. Properly correct or replace kitchen exhaust as needed for function and safety. Correct any affected areas, if needed.
Cooking Exhaust Inoperative
The kitchen exhaust system was inspected and found inoperative when using the normal operating controls.
Properly put the system back in service correcting as needed for function and safety.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom
Full Bathroom
Location Full Bathroom Upstairs, EnSuite, attached to a bedroom
Bathing Area: Shower
Hand Washing: Vanity with basin
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
- Window present to ventilate bathroom.
Floor Covering: Tile
- Some wear noted, recondition to your standard
Bathing Area: Shower Head (Leak at Shower Head)
Location Full Bathroom Upstairs, En Suite, attached to a bedroom
Shower Area
Leak observed at shower head piping. Properly correct as needed.
Bathroom
Full Bathroom
Location Full Bathroom Upstairs, at Hall
Bathing Area: Combination tub and shower
- Appropriate upgrade recommended for shower enclosure area.
Hand Washing: Vanity with basin
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Window present to ventilate bathroom.
Floor Covering: Engineered Flooring
- Some wear noted, recondition to your standard
Bathroom
Full Bathroom, Irregular
Location Full Bathroom Basement
Bathing Area: Shower
Hand Washing: Vanity with basin
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
- Confined seating observed at toilet. Upgrade if needed.
- Confined standing area observed at toilet. Upgrade if needed.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering:
- Some wear noted, recondition to your standard
Location Full Bathroom Basement
Monitor irregular bathroom installation.
Consider this area for upgrade. Make corrections as necessary to meet your needs if not upgrading now.
Bathing Area: Shower Head (Leak at Shower Head)
Location Full Bathroom
Shower Area
Leak observed at shower head piping. Properly correct as needed.
Floor Covering: Improve (Incomplete)
Flooring
- Flooring at basement bathroom was irregular. Obtain installation instructions. Properly correct to your standard.
Location Full Bathroom Basement
Sink
Sink was loose.
Properly secure sink as needed to help prevent leaks.
Location Full Bathroom Basement
Sink
Leak observed under sink.
Properly repair leak and any affected areas.
Full Bathroom at Basement
Ductwork for multiple bathroom exhaust fans were observed connected together exhausting to a single discharge outlet.
Typically each fan requires an independent discharge outlet. Refer to installation instructions for each fan properly correcting as needed for function and safety. Also, clothes dryer exhaust should not be connected to bathroom exhausts.
Location Full Bathroom Basement
Properly put this bathroom back in service.
LAUNDRY
Laundry Connections
Laundry: Appliances Present
Laundry appliances were present during inspection.
Laundry appliances restricted view of laundry connections. Laundry appliances typically do not convey with property. Laundry appliances are not evaluated during inspection. Laundry faucets are not operated when appliances are connected to faucets. Verify your clothes dryer exhaust is functional, safe and properly installed to meet the requirements of clothes dryer manufacturer in use.
Clothes Dryer:
Clothes dryer exhaust observed irregular as it was connected to two exhaust fans at basement bathroom.
Properly correct clothes dryer exhaust to meet manufacturer requirements.
PLUMBING
Supply Piping
Supply Piping: Copper, PEX
Waste Piping
Waste Piping: Plastic, Metal
Functional waste water flow observed during inspection for water outlets operated.
Apparent Vent Piping
Metal, Plastic
Exterior Hose Faucets
Water Heater
Water Heater
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior type areas have contingency measures installed to mitigate expected leakage or rupture of water heater.
Such measures would collect and drain unwanted water to exterior to avoid damaging interior finishes. Consider upgrading water heater installation to help reduce unnecessary damage when the water heater leakage occurs.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Missing
A plumbing thermal expansion tank was not observed near the water heater.
Monitor this area for leaks adding an expansion tank if needed.
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Basement
________________________________________________________________________________________________________________________________________________________________
Plumbing Other
Multiple plumbing corrections were needed.
A Licensed Competent Plumbing Contractor should further evaluate entire plumbing system. Properly repair or replace plumbing system as needed to make system fully functional and safe.
CENTRAL SYSTEM
Central Heat/Cool
Package System
Central Heating/Cooling
Package, Forced Air System Served: System served majority of home
Brand Furnace: Rheem / Location: Exterior Package Unit / Fuel: Natural Gas; Forced air system
Size: 80K BTU / Year of Manufacture: 2021
Package gas furnaces with electric cooling typically have a service life of 15-20 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Size: 3 ton / Fuel: Electric
Condensate disposal method: Gravity drain for condensate
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Functional
Cooling System Functional
Inspector adjusted thermostat. Cooling system engaged and was found to be functional.
________________________________________________________________________________________________________________________________________________________________
Heating Function: Functional
Heating System Functional
Inspector adjusted thermostat. Heating system engaged and was found to be functional.
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served, if present, shade, climate zone along with size, number and placement of windows have to be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the the installed central heating and cooling equipment. Properly maintain the ductwork system to meet your comfort needs and to allow system to operate properly.
Ductwork: Single Unit Serving Multiple Floors, Return at One Level, Ductwork Not at All Rooms
Ductwork
A single central heat/cool system was installed serving multiple floor levels. When one central system serves multiple floor levels expect some temperature disparity between floor levels. Seasonal adjustment of vent diffusers may help. A heating contractor may also be hired to modify the system. Monitor your comfort level and correct as desired to meet your needs.
Ductwork
The central heat/cool system served multiple floor levels with an air return installed only at one of those levels. Monitor your comfort level properly correcting if needed.
Ductwork
Some rooms did not appear to be served by central system ductwork. Monitor your comfort level correcting if desired.
Ductwork did not appear installed to serve:
- Basement bathroom
- Basement left rear room
Gas
Gas Fuel Piping
Natural gas piping observed at inspected property.
Properly maintain gas piping protecting from physical damage as needed.
Installation Issue: Sediment Trap
Furnace System served majority of home
Gas Piping was ready for proper correction.
Properly correct gas piping where needed.
- Sediment trap for gas piping to furnace was not visible.
Gas Appliance Flue
Flue
Furnace
Furnace
Flue Type: Metal Flue Self Contained
Properly maintain flue for safety and function.
Flue cont
Water Heater
Water Heater
Flue Type: Metal Flue, exhaust discharged through roof
Flue corrections were needed.
Flue: Clearance Metal Flue Roof Deck
Water Heater
Gas appliance metal flue needed correction.
Gas appliance metal chimney flue appeared too close to combustible roof decking and should be properly corrected for safety. A single wall metal flue generally needs six inches clearance away from combustibles while a double wall metal flue will typically only need one full inch clearance away from combustibles. A competent heating technician should further evaluate and properly correct gas appliance metal flue as needed for safety and function.
Space Heating
Space Heater
Location: Basement
Fuel: Natural Gas
Type: Blower heater
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment is most often one or more installed breaker panels and the branch wiring runs to all equipment, receptacles, lighting outlets and devices such as the light switches. The inspection report focuses on wiring operating between 100-250 Volts. While system Amperage and Voltage is recorded, it is not measured during inspection. Most low voltage wiring is excluded from the performed inspection. Low voltage items such as a heating and cooling thermostat are operated in order to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify each lamp or bulb is appropriate for the installed lighting fixture. The inspector recommends that you review the bulb or lamp installations for each fixture correcting as needed for safety and function. Common errors include 100 watt bulbs installed in fixtures rated for 60 watt max bulbs and interior rated bulbs installed at exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. Most, if not all, electrical corrections should be considered a safety concern.
Electrical Service
System Amperage and Voltage, identified but not measured: 100 Amps - 120/240 Volts
Electrical Service Type: Overhead, Service Older
Ground Rod: Ground Rod Not Observed
Electrical Service
Ground rods were not observed for use as a supplemental earthing of stray electrical current. Electrical system did not appear to have ground rods near the electric meter for the electrical service. This is an important safety item to help prevent shocks, fire or equipment damage. The inspector recommends an upgrade and properly adding ground rods for safety where needed.
MAIN PANEL
Main Electrical Panel
Main Breaker Panel Basement
Service Entrance Conductors: Aluminum, Stranded
Index: Index
Electrical panel directory was ready for correction. Properly index or label each electrical panel circuit as needed for clarity and safety.
Access: Working Access
Observed electrical equipment panel should have unobstructed dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel. This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to the electrical panel.
Enclosure: Protect Wiring at KO
Enclosure: Panel Cover Not Installed
Wiring: Remark White 240V Breaker
Wiring: Improper Wiring, Sheathing Excess
Breaker: Over Breakering
Some breakers appeared mismatched to wire size. Properly correct where needed.
Upgrade: Distribution Equipment Upgrade Recommended
In the inspector's opinion, now is the time to consider an electrical upgrade for the distribution electrical equipment. Updating this older equipment properly will improve safety and convenience.
Main Breaker Panel Basement
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
Branch Wiring
Material: Copper
Wiring Method: Non Metallic Sheathed Cable
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
AFCI
AFCI Residential
What is Arc Fault Circuit Interrupter (AFCI) Protection?
AFCI protection is designed to break the electrical circuit when it detects electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Most, but not all, homes will have a need for additional AFCI protection based on varied municipal enforcement and the numerous changes for which areas require AFCI protection. Evaluate your risk exposure. Consider adding AFCI protection where needed for improved safety, particularly where construction was completed 2002 or later.
Modern Locations Where AFCI Protection is Known to Improve Safety:
Dwelling Units. All 120-volt, single-phase, 10-, 15-, and 20-ampere branch circuits supplying outlets or devices installed in the following locations:
Kitchens,
Family Rooms,
Dining Rooms,
Living Rooms,
Parlors, Libraries,
Dens,
Bedrooms,
Sunrooms,
Recreation Rooms,
Closets,
Hallways,
Laundry Areas,
or similar areas.
Testing AFCI Function
The inspector uses push button at AFCI breakers, where installed, to confirm AFCI protection trips. Once tripped, the inspector checks indexed electrical circuits to determine where AFCI protection is present or missing.
Obvious locations lacking AFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired AFCI receptacles or breakers are listed in the summary of the report. Evaluate your risk exposure.
No AFCI Built Before 2002
Areas That Did Not Appear AFCI Protected
No AFCI protection was observed at inspected property. AFCI protection is not expected for homes built before 2002. If installation of AFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI
GFCI Residential
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Dwelling Units.
(A) Dwelling Units
All 125-volt through 250-volt receptacles installed in the following locations and supplied by single phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.
(3) Outdoors
(4) Crawl spaces - at or below grade level
(4) Basements
(5) Kitchens
(6) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(7) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Boathouses
(9) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(10) Laundry areas
(12) Indoor damp and wet locations
Some exceptions apply, see current standard for a list of exceptions.
(B) Pertains to Other Than Dwelling Units
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
(F) Outdoor Outlets. For dwellings, all outdoor outlets, including outlets installed in the following locations, and supplied-by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, shall be provided with GFCI protection:
(1) Garages that have floors located at or below grade level.
(2) Accessory buildings
(3) Boathouses
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Older Home
GFCI protection was ready for upgrade at older inspected property. Consider modernizing electrical installation adding this shock protection for all electrical areas where GFCI protection is known to improve safety. If installation of additional GFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
Receptacle Outlets
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Some electrical receptacles were observed improperly installed.
- Older two wire electrical receptacle circuits observed in need of correction.
- Some electrical receptacles were observed damaged.
- Install proper cover plates where needed at interior.
An electrical contractor should check all receptacles making functional and safe where needed.
Two Wire Receptacles
3 Corrections 2 Wire Receptacle Circuits, Preferred Method 2 Wire Receptacles
Regarding Two Wire Electrical Receptacle Outlets
Inspector informational note regarding proper wiring of 120V electrical receptacles on two wire electrical circuits such as in older homes and in the inspected property.
There are three proper wiring methods for older two wire receptacle circuits:
- Two wire receptacle circuits may have two wire receptacles, if properly installed.
- Two wire receptacle circuits may have replacement three wire receptacles, if properly installed, GFCI protected and appropriately marked 'NO EQUIPMENT GROUND'. GFCI protected receptacles without test/reset buttons should also be appropriately marked 'GFCI PROTECTED OUTLET'.
- Two wire receptacle circuits may be properly replaced with three wire receptacle circuits and three wire receptacles.
Two Wire Electrical Receptacle Outlets
Inspector informational note regarding personal preferred wiring method for 120 V two wire electrical receptacles circuits found in older homes.
There are multiple ways to properly address electrical receptacles on two wire circuits. The inspector has developed a personal preference for your consideration. This preference eliminates the need for stickers on most of the receptacles. This preference eliminates confusion regarding which receptacles have a grounding wire and which do not.
INSPECTOR PREFERRED METHOD
Newer two wire receptacles are used on two wire receptacle circuits.
Replace any two wire receptacles that are damaged or where a plug is loose when plugged into receptacle.
For two wire receptacle circuits needing GFCI protection, GFCI breakers are utilized rather than GFCI receptacles.
Where three wire receptacles are necessary or desired, three wire receptacle circuits are either confirmed existing already or a new three wire circuit is added.
Areas where three wire receptacles are beneficial include:
Exterior, Garages and circuits that serve refrigerator, freezer, microwave, clothes washer, garage door operator, computers and other electronics, appliances or tools with a three wire cord. Adding grounded electrical receptacles for electronics, appliances or tools that have a two wire cord is not necessary.
2 Wire Present, Mixed Circuits, Correct Where Needed, Label Where Needed
Two Wire Electrical Receptacle Outlets
The inspector observed some electrical circuits that appeared to have a grounding conductor and some circuits that did not appear to have a grounding conductor. This is not unusual for the age of the property inspected. Monitor your electrical need and consider upgrading wiring as appropriate.
Two Wire Electrical Receptacle Outlets
Properly correct two wire receptacle circuits where needed to improve safety.
Two Wire Electrical Receptacle Outlets
Properly identify 3 wire receptacles installed on 2 wire circuits as 'GFCI Protected' and 'No Equipment Ground' where needed.
Three Wire Receptacles
Three Wire 240V Receptacles Observed
Some older 240V 3 wire electrical receptacle circuits were observed. Typically, these circuits would serve electric clothes dryers or electric kitchen ranges but may also serve other areas. Evaluate your risk exposure and consider upgrade replacement of any 240V 3 wire receptacle circuits where present with a modern 240V 4 wire receptacle circuits for improved safety. Properly maintain older 240V 3 wire receptacle circuits to meet your needs and for safety, if not upgrading older circuits now.
Lighting/Ceiling Fans
Cord and Plug Connected Lighting, Exposed Closet
Lighting
Exposed incandescent type light fixture was observed at closet. Stored items should be kept away from surface mounted incandescent closet lights to reduce the risk of fire. Use caution with this type fixture. Install low wattage LED light bulbs or fixture with a globe to help reduce heat transfer risk.
Lighting/Ceiling Fans
Correct Lighting Where Needed
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were improperly installed.
- Some light fixtures were damaged.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
Switches Erroneous
Switches
Inspector was unable to determine function of all switches present. Switches may operate flood lights, receptacles or other item. They may also be an unused extra switch.
Smoke Alarms
Smoke Alarm Installation: Where Should Smoke Alarms be Installed?, Additional Smoke Alarms Recommended
Depending on the age and location of the home, installation of smoke alarms are either recommended or required for improved safety.
Modern smoke alarm systems typically are hardwired to the electrical system and will have battery backup so that they will function when the power is off to the building. Modern smoke alarm systems typically have all smoke alarms interconnected so that when one alarm sounds then all smoke alarms will sound simultaneously. This is useful for heavy sleepers and in larger homes.
Modern smoke alarm systems typically have smoke alarms installed at the following locations:
- In the immediate vicinity outside sleeping areas
- Inside sleeping areas
- At least one per floor level including basements
- Near stairs
- In unfinished basements
- (some installations will require additional smoke alarms)
It is important to note that a single smoke alarm can satisfy multiple areas if carefully placed.
It is common to have a single smoke alarm near the top of the stairs and just outside multiple sleeping areas.
Properly maintain smoke alarm system as needed for life safety.
Regarding Testing Smoke Alarms:
Test smoke alarms weekly to ensure proper function for life safety. Replace batteries when needed. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
The inspector does not test smoke alarms. For safety, the inspector only accesses smoke alarms from the installed flooring. To prevent damage, the inspector does not remove smoke alarms or open smoke alarm covers.
Smoke alarms were not present for all areas where now recommended or required.
Installation of additional smoke alarms is recommended.
- Inside sleeping rooms
Evaluate your risk exposure. Upgrade smoke alarms to meet your needs and for life safety.
Read and follow the smoke alarm manufacturer installation and operating instructions.
Contact your local Fire Marshal if need be.
Bond
Metal and Plastic Piping
Electrical Bonding
An electrical bonding jumper was needed to connect metal plumbing supply piping to the electrical system in order to prevent the metal plumbing supply piping from accidentally becoming energized should an electrical malfunction occur. Plastic plumbing supply piping introduced into metal plumbing supply piping system has interrupted the continuity of the electrical bond for the metal plumbing supply piping that should earth any stray electrical current that may be encountered during a malfunction. The correction for this issue will typically only take a few minutes for a competent electrical contractor to complete where needed.
STRUCTURE
Attic Access
Attic Access: Scuttle Hole
Attic Access: Not Floored
Attic area viewed from access point only due to lack of walk boards. Some areas of attic may not have been viewed.
Roof Framing
Framing: Rafters, Wooden
Sheathing: Plywood, OSB
Roof Framing: Older Typical
Original framing, where visible, was observed typical for age of structure and may not meet current building standards. Monitor area periodically and make corrections if condition changes.
Ceiling Framing
Ceiling Framing: Wood
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector.
Wall Framing
Wood, Concrete Block
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector.
Basement: Furring Strips Monitor Older
As expected for age of home, older basement wooden wall framing, where non bearing, was observed with lumber smaller than 2"x 4 " wall studs used to attach finished walls. Using traditional wall studs allows use of modern electrical wiring methods and wall insulation. Monitor this area upgrading when necessary or desired.
Underfloor Access
Basement: Semifinished
Basement Semifinished
Some areas were finished. The components behind the finished areas were not observed. Concealed areas are not part of the inspection performed.
Underfloor Description
Attributes: Basement Semi Finished
Underfloor Area
Access:
- Basement walked
Construction Type:
- Basement - Semi Finished
Foundation:
- Concrete Block
Columns or Piers:
- Load Bearing Wall
Floor Structure:
- Floor Joists - Solid Wood
- Beam - Built Up Wood
- Subfloor - Wood
Foundation
Foundation Warrants Further Evaluation
Foundation Warrants Further Evaluation by a Specialists
A competent qualified contractor, foundation specialist or State licensed professional engineer should further evaluate entire foundation system and all supports determining corrective measures needed, take action to prevent recurrence and properly repair affected areas where needed. Making corrections for areas where needed now would help reduce predictable unnecessary settlement or possible collapse of structure.
Floor System
Floor Framing: Load Path Settlement
Some settlement was observed that may or may not be related to the structural load path of the building.
It is beyond the scope of this inspection to determine the structural load path or calculate structural integrity. Monitor framing budgeting corrective measures if condition worsens.
INSULATION
Above Ceiling Insulation
Recommended Insulation, Insulation Photo
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Insulation Type: Blown In
Observed Insulation Approximate Depth: R - 30, R - 19 Where Compressed
Consider Improving Insulation: Energy Audit Recommended
Consider obtaining evaluation by an energy auditor for property to improve energy efficiency and comfort.
Wall Insulation
Insulation: None expected at basement walls .
MOISTURE
Basement
Basement: Practical Steps Basement Moisture, Interior Damp Proofing Observed, Basement Dry But Older
Practical steps to better moisture condition at a typical basement.
- Properly divert any storm water and all gutter down spouts a minimum 10 feet away from foundation.
- Correct any exterior grading issues that prevent storm water from flowing away from foundation.
- Install proper size dehumidifier if needed to help control high humidity.
- Properly drain any excess bulk moisture from basement, if present, to prevent accumulation.
- Take more aggressive steps if necessary such as installing a dewatering system.
Interior damp proofing was observed applied to basement walls. Waterproofing should be done on exterior walls at and below soil grade at time of construction. Interior damp proofing may indicate moisture penetration. Monitor area and correct as needed.
- Interior Damp Proofing observed at basement wall.
Interior Moisture Signs
Interior: Moisture Stains Observed Dry
Dry moisture stains were observed. Stains are evidence of a prior undesirable moisture condition. Monitor area to verify cause of stain is not still present. Further evaluation may be needed if cause of stains persists. Properly correct cause of stain if needed. Properly repair affected areas as needed. Some affected areas may be concealed and are not part of the inspection performed.
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Ridge Roof Vent
Attic Intake Vents: Soffit Vents Where Installed
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof
Roof Style: Hip
Approximate Age of Roof Covering: 12-16 Years
Roofing Material: Composition Three Tab Shingle
Observation: Serviceable, Fulfilling Its Function
The roof covering overall was found generally serviceable within the parameters of its given service life. All roofing requires periodic maintenance. Properly maintain and correct roof covering as needed, when needed.
Gutters and Downspouts
Gutter and Downspout Materials: Metal
Best Time to Replace
The best time to replace guttering is while you are having the roof covering replaced.
Observation: Budget Gutter Removal Damaged Fascia
Budget removal and replacement of gutters where needed to facilitate proper repairs of fascia at eaves.
Downspout: Under
Gutters: Replace or Repair
Replace or repair gutters as needed for proper function.
SIDING and TRIM
Siding
Siding: Composition Siding, Wood
Eaves: Painted Wood
Trim: Wood
Siding: Carpenter Bees
Siding: Corrections Needed
Exterior siding was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Physical Damage Observed
- Failing Paint Observed
- Temporary Repairs Observed
- Rot Observed
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance. Affected adjacent areas that are concealed or not readily accessible are not part of the inspection performed.
Masonry Siding
Brick Veneer
What is Brick Veneer
Brick veneer siding serves as a non-structural outer layer of masonry. In contrast to solid brick constructions, which rely on multiple layers of brick for structural support, brick veneer systems depend on the underlying structure to support the masonry. The removal of the brick veneer would not compromise the building's structural integrity.
Siding - Stucco
Stucco Over Concrete Block where installed
Siding: Requires Maintenance, Upgrade or Maintain
Stucco
Upgrade or maintain stucco to meet your needs.
LOTS and GROUNDS
Driveway
Walkway
Concrete
Area had a partial roof structure.
Patio
Stairs and Railings at Exterior
Diagram: Older Railing & Stairs
Railings and Stairs at older home as expected, did not meet current safety standards. Railings and stairs were ready for modernization for improved safety. Evaluate your risk exposure. Consider proper repair or replacement of stairs and railings where needed now for safety and function.
Vegetation
Vegetation Maintenance, Overgrown Shrubs
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Shrubs or other vegetation appeared too close to the exterior walls and can transfer unwanted moisture that may be detrimental to building components. Review vegetation correcting where needed. Consider having enough separation between plants and exterior walls so that you can walk as this allows air circulation and improves access for home maintenance. Areas concealed by overgrown vegetation were not observed by inspector.
Site
Site: Adjust Grade Basement
Some exterior grade work may improve storm water runoff away from basement type foundation. Slope grade minimum ten feet away from and around the structure so that water does not collect at foundation. Be careful not to raise grade at the structure above the foundation water proofing.
Retaining Wall
Retaining Wall
End of Report
Thank You Note
Thank you so much for trusting me to perform your inspection!
Please reach out if I may assist you further.