How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Further Evaluation:Observations listed as further evaluation need a more extensive or technically exhaustive evaluation and warrant further investigation by a specialist. For areas where corrections may not be straight forward or where a proper plan should be developed to implement corrections, then further evaluation is recommended. To obtain further evaluation is to hire a specialist that is highly experienced in the repair or correction of a specific item or area. Some observations listed under other labels that also require further evaluation will appear under the other label only. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Routine Correction Needed:Observations listed as routine correction need repair or correction and are not unusual for the type and age property inspected. These routine items are typically not recurring and once properly corrected should not require repetitive correction. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- K-1 KITCHEN:
Range
Clearance appeared improper above cook surface.
Most ranges and cooktops require a minimum 30" clearance to combustibles above cook surface for fire safety. Refer to installation instructions and provide proper clearance or properly relocate cooking appliance as needed for safety and function.
- K-2 KITCHEN:
Location Kitchen
Sink Faucet
Leak observed at faucet handle.
Properly repair faucet for correct function.
- B-1 BATHROOM:
Location Full Bathroom at Hall
Sink Faucet
Faucet was loose. Properly secure faucet as needed.
- B-2 BATHROOM:
Location Full Bathroom at Hall
Sink
Waste drain piping was irregular.
Proper correction of irregular waste drain piping is recommended.
- Waste piping beneath bathroom sink was improperly installed as an S Trap was present.
- Waste piping beneath bathroom sink was improperly installed as it was double trapped.
- P-2 PLUMBING:
Water Heater
Water heater temperature and pressure relief valve had discharge extension piping that was not rated for hot water and this pipe should be properly replaced.
- PVC piping is not rated for use with hot water and should not be used at water heater for temperature and pressure relief valve discharge piping.
Refer to discharge piping general guidelines. Proper correction is needed for correct function and safety.
- P-3 PLUMBING:
Water Heater
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Pressure temperature relief valve discharge piping was not installed properly.
- CS-1 CENTRAL SYSTEM:
Furnace at crawl space did not have reasonable access for servicing or inspecting system. Inspector was unable to fully evaluate furnace installation when inspected. Create proper access to furnace. Have system installation evaluated properly correcting as needed for function and safety.
- CS-2 CENTRAL SYSTEM:
Heating System
Proper servicing of system is recommended. Due to the condition of the heating system, it is recommended that a qualified competent heating contractor service this system properly repairing as needed for function and safety.
- Furnace system was not installed properly. Correct before use.
- CD-1 Central Ductwork:
Ductwork
Ductwork observed in contact with the ground.
Central system ductwork should not touch the floor of the crawlspace. Ductwork may become damaged by moisture from ground contact. A competent heating contractor should check all ductwork and properly correct or replace ductwork as needed.
- CD-2 Central Ductwork:
Ductwork
Ductwork insulation observed in need of correction for some areas. Have a competent heating contractor check all ductwork properly correcting where needed.
- Ductwork insulation observed missing
- CD-3 Central Ductwork:
Ductwork
The inspector noted damage to the ductwork system.
A competent heating contractor should check all ductwork and properly correct or replace ductwork as needed.
- CD-4 Central Ductwork:
Ductwork
Properly replace or repair duct system as needed to adequately heat and cool all finished areas.
- G2-2 Gas:
Gas Piping was ready for proper correction. Properly correct gas piping where needed.
- Sediment trap for gas piping to furnace was not visible.
- GAF-1 Gas Appliance Flue:
Furnace Flue
Gas appliance metal flue needed correction.
The gas appliance chimney flue had an installed electric powered vent fan to exhaust the gas appliance flue gases to the exterior atmosphere. This electric fan should be as close to the exit point of the flue at the exterior wall as possible for safety. The installed fan appeared father away from the flue exit point than expected. A fan installed too far away from this area can blow carbon monoxide into living space if the flue is not sealed properly. A competent heating technician should further evaluate and properly correct the gas appliance flue as needed for safety and function.
- E-2 ELECTRICAL:
Electrical Service
Observed electrical service should have unobstructed, dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel.
This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to electrical service.
- E-3 ELECTRICAL:
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
- E-4 ELECTRICAL:
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Install proper cover plates where needed at exterior.
- Some electrical receptacles were observed inoperative such as at right exterior.
- Properly correct loose electrical receptacles and loose electrical receptacle junction boxes where needed.
An electrical contractor should check all receptacles making functional and safe where needed.
- E-5 ELECTRICAL:
Lighting
Service lighting was missing for Furnace at Crawl Space.
- Existing lighting at area did not properly illuminate service area for appliance and additional lighting should be installed.
Equipment requiring periodic servicing should have permanent lighting installed near such equipment that illuminates the control side of the equipment. This service lighting should be controlled by a switch that is installed at the entry point to the area where the equipment is installed. Consider properly adding additional lighting where needed near such equipment for improved safety and to facilitate servicing equipment when needed.
- E-6 ELECTRICAL:
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some light fixtures were improperly installed.
- Some ceiling fans needed correction.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
- AL-1 ATTIC LADDER:
Attic ladder was observed ready for corrections now and before use to improve the function and safety aspects of the attic ladder.
Refer to the full report for additional information and photos regarding obvious corrections recommended now for the attic ladder area. A competent qualified contractor capable of reading and following the manufacturer installation instructions should check all attic ladder areas. Make attic ladder functional, safe and structurally sound where needed.
- S-1 STRUCTURE:
Home was a candidate for demolition if proper structural repairs, needed now, are not feasible.
Obtain competitive bids for all work needed.
Obtain further evaluation for areas as instructed.
- M-1 MOISTURE:
Plastic sheeting, vapor retarder, covering soil areas inside the underfloor crawl space was ready for replacement.
A vapor retarder is an important measure to reduce moisture inside underfloor crawl spaces. Properly remove any debris from crawl space and replace vapor retarder for improved moisture control at crawl space area.
- R-1 ROOF:
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Remove vegetation debris from roofing where needed.
- Vegetation on roof covering concealed view of areas.
- Roof framing was sagging and in need of correction to properly support dimensional shingles..
- Some shingles observed damaged.
- R-2 ROOF:
Roof Covering
Coordinate roof covering corrections needed now in conjunction with roof framing corrections needed now.
Further Evaluations
- P-1 PLUMBING:
Plumbing Waste Piping
Plumbing waste drain piping was irregular at crawl space.
Further evaluation and proper correction of irregular waste drain piping is recommended.
- P-4 PLUMBING:
Multiple plumbing corrections were needed.
A Licensed Competent Plumbing Contractor should further evaluate entire plumbing system. Properly repair or replace plumbing system as needed to make system fully functional and safe.
- G2-1 Gas:
Furnace
A Gas Utility Company 'Red Tag' was observed during inspection. Verify conditions causing utility company to issue this 'Warning' have been properly corrected before occupying home. Make any proper corrections as needed to ensure system is fully functional and safe. Properly remove Gas Utility Company 'Red Tag' when safe to do so.
- Red tag provided by utility was not legible. Contact utility company.
- Gas was on to furnace.
- E-1 ELECTRICAL:
Electrical Service
Electrical service mast extended farther above roof than expected.
Mast may require bracing or other correction. Further evaluation is recommended for this area. Contact governing authority such as municipality or competent electrical contractor. Properly correct if necessary.
- S-2 STRUCTURE:
Roof Framing
Further evaluation of roof framing system was needed. Conditions observed at roof framing that warrant further evaluation by a specialist. A competent qualified contractor should further evaluate entire roof framing system and all supports determining corrective measures needed, take action to prevent recurrence and properly repair affected areas where needed.
- Representative Photos Provided
- Some roof framing was damaged and unrepaired.
- Some roof framing was outdated or improper.
- Irregular alterations to roof framing were apparent.
- Replace or correct roof framing to make area structurally sound.
- S-3 STRUCTURE:
Roof Framing
Coordinate roof framing corrections needed now in conjunction with roof covering corrections needed now.
- S-4 STRUCTURE:
Floor Framing and Supports
Conditions observed at floor system that warrant further evaluation by a specialist.
A competent qualified contractor should further evaluate entire floor system and all supports determining corrective measures needed, take action to prevent recurrence and properly repair affected areas where needed. Making corrections for areas where needed now would help reduce predictable unnecessary settlement of structure.
- Representative Photos Provided
- Floor framing was outdated or improper.
- Some floor framing was damaged and unrepaired.
- Some floor framing was damaged and partially repaired.
- Older foundation observed in need of corrections.
- Shoring or strengthening measures observed were irregular.
- Obvious preventable load path settlement had occurred and proper correction is recommended.
- Flooring was noticeably out of level at multiple areas.
- Further evaluation should include a load path analysis for the structure.
- Replace or correct floor framing, foundation and supports to make area structurally sound.
- S-5 STRUCTURE:
Suspect termite activity observed.
The inspector recommends further evaluation by a specialist properly correcting as needed. An exterminator is needed to determine if termite presence is active or not. Often termite activity is related to a moisture condition. Properly correct any undesirable moisture conditions as needed.
The Full Report
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Exterior Hose Faucets
Water Heater
Equipment Observed
Plumbing Other
ELECTRICAL
Electrical Inspection
ELECTRICAL SERVICE
MAIN PANEL
Branch Wiring
AFCI
GFCI
Receptacle Outlets
Three Wire Receptacles
Lighting/Ceiling Fans
Lighting/Ceiling Fans
Switches
Smoke Alarms
STRUCTURE
Commentary
Attic Access
Roof Framing
Ceiling Framing
Wall Framing
Underfloor Access
Underfloor Description
Floor System
Other Concerns
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Home Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Single Family Home
Site Built, Apparent additions built after original construction were observed.
Approximate Square Footage: 1000
Approximate Year of Original Construction: 1950
Weather during the inspection: Clear
Ground/Soil surface conditions: Dry
Approximate Low Temperature During Inspection: 60[F]
Approximate High Temperature During Inspection: 72[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Empty of Furnishings
Home was empty of furnishings when inspected.
________________________________________________________________________________________________________________________________________________________________
Ceilings
________________________________________________________________________________________________________________________________________________________________
Walls
________________________________________________________________________________________________________________________________________________________________
Flooring
Interior Flooring Materials: Engineered Flooring, Sheet Vinyl
Interior Flooring Condition:
- Recondition to your standard.
Doors
Doors at Interior: Missing, Some door operation could be improved
Doors Replace Repair
Replace, repair or upgrade interior doors to meet your needs. Properly correct any affected adjacent areas, if present.
________________________________________________________________________________________________________________________________________________________________
Doors to Exterior: Hollow, Locking, Some door operation could be improved.
Replace, Repair, Check All
Replace, repair or upgrade doors to exterior to meet your needs. Properly correct any affected adjacent areas if present. Check all doors to exterior properly making doors functional, secure and weather tight to meet your needs.
Glazing/Glass
Single pane glass was present.
Windows
Metal framed windows were present.
Wood framed windows were present.
Screens, Storm Windows
Window screens are not required on homes with central cooling system air conditioning. Install window screens where missing, if desired.
One or more storm windows were present. Storm windows are outside the scope of this inspection and were not evaluated.
Window List, Budget Replacement
Windows needed correction when inspected. Windows were ready for corrections. Window conditions observed appear below in a bulleted list below. Check all windows correcting as needed for function and safety.
- Some windows did not operate properly.
- Some windows dropped swiftly when open.
- Some window locks needed correction.
- Failing paint was observed.
- Broken sash ropes observed.
Budget replacement windows. The condition and operation of existing windows justifies consideration of installing upgrade replacement windows rather than performing the exhaustive corrections needed at present to the installed windows.
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following builtin kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area: Main Level
Kitchen
Countertop: Laminate
- Some wear noted, recondition to your standard
Cabinets: Wood and wood composition, painted
- Wear and damage observed, budget reconditioning
Floor Covering: Engineered Flooring
- Flooring was not level. Consider for correction.
Sink: Double Bowl Stainless Steel
- Signs of past leakage observed. Maintain area to meet your needs.
Disposal: Not Present
Dishwasher: Present and ran through a normal cycle without incident
Range: Range (Electric Top/Oven)
Present and On/Off Tested functional
Microwave: Not Present
Kitchen Exhaust: Not Present
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Range
Clearance appeared improper above cook surface.
Most ranges and cooktops require a minimum 30" clearance to combustibles above cook surface for fire safety. Refer to installation instructions and provide proper clearance or properly relocate cooking appliance as needed for safety and function.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom 1
Full Bathroom
Location Full Bathroom at Hall
Bathing Area: Combination tub and shower
- No leaks were observed around faucet and the water containment area appeared serviceable.
- Shower was run only briefly as no shower curtain/door was present.
Hand Washing: Vanity with basin
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
Floor Covering: Engineered Flooring
- Wear noted, properly recondition to meet your needs
Location Full Bathroom at Hall
Sink Faucet
Faucet was loose. Properly secure faucet as needed.
Location Full Bathroom at Hall
Sink
Waste drain piping was irregular.
Proper correction of irregular waste drain piping is recommended.
- Waste piping beneath bathroom sink was improperly installed as an S Trap was present.
- Waste piping beneath bathroom sink was improperly installed as it was double trapped.
LAUNDRY
Laundry Connections
Laundry: Connections Available
Clothes washer and dryer connections were available.
Laundry appliances were not present during inspection. Laundry faucets are not operated when the basin beneath the faucets is inadequate to contain the faucet flow without a hose being connected to the faucets. Verify your clothes dryer exhaust is functional, safe and properly installed to meet the requirements of clothes dryer manufacturer when installed.
PLUMBING
Supply Piping
Supply Piping: CPVC, PEX
Galvanized Steel Piping: Galvanized Steel Piping Observed
Galvanized steel plumbing supply piping was observed. This type of piping may be nearing or past the age of normal life expectancy. You should monitor the piping and budget replacement of the galvanized piping as leaks occur or flow restrictions are observed. Consider replacing older galvanized piping as preventative maintenance.
- Galvanized steel plumbing piping was viewed in use as plumbing distribution piping..
Waste Piping
Waste Piping: Plastic, Metal
Apparent Vent Piping
Metal
Exterior Hose Faucets
Water Heater
Water Heater
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior type areas have contingency measures installed to mitigate expected leakage or rupture of water heater.
Such measures would collect and drain unwanted water to exterior to avoid damaging interior finishes. Consider upgrading water heater installation to help reduce unnecessary damage when the water heater leakage occurs.
Water Heater
Water heater temperature and pressure relief valve had discharge extension piping that was not rated for hot water and this pipe should be properly replaced.
- PVC piping is not rated for use with hot water and should not be used at water heater for temperature and pressure relief valve discharge piping.
Refer to discharge piping general guidelines. Proper correction is needed for correct function and safety.
Water Heater
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Pressure temperature relief valve discharge piping was not installed properly.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Present
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Crawl Space
________________________________________________________________________________________________________________________________________________________________
Plumbing Other
Multiple plumbing corrections were needed.
A Licensed Competent Plumbing Contractor should further evaluate entire plumbing system. Properly repair or replace plumbing system as needed to make system fully functional and safe.
CENTRAL SYSTEM
Central Heat/Cool
Split System
Central Heating/Cooling
Split, Forced Air System served: System served majority of home
Brand Furnace: Weather King / Location: Crawl Space / Fuel: Natural Gas
Size: Unknown / Year of Manufacture: unknown
Gas furnaces typically have a service life of 16-22 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Rheem / Location: Exterior / Fuel: Electric
Size: 3 ton / Year of Manufacture: 2010
Central cooling units typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Gravity drain for condensate
The inspector recommends annual servicing for all equipment ten years old and older.
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Functional
Cooling System Functional
Inspector adjusted thermostat. Cooling system engaged and was found to be functional.
________________________________________________________________________________________________________________________________________________________________
Furnace at crawl space did not have reasonable access for servicing or inspecting system. Inspector was unable to fully evaluate furnace installation when inspected. Create proper access to furnace. Have system installation evaluated properly correcting as needed for function and safety.
Heating System
Proper servicing of system is recommended. Due to the condition of the heating system, it is recommended that a qualified competent heating contractor service this system properly repairing as needed for function and safety.
- Furnace system was not installed properly. Correct before use.
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served, if present, shade, climate zone along with size, number and placement of windows have to be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the the installed central heating and cooling equipment. Properly maintain the ductwork system to meet your comfort needs and to allow system to operate properly.
Ductwork: Ductwork Not at All Rooms
Ductwork
Some rooms did not appear to be served by central system ductwork. Monitor your comfort level correcting if desired.
Ductwork did not appear installed to serve:
- Laundry Room
Ductwork
Ductwork observed in contact with the ground.
Central system ductwork should not touch the floor of the crawlspace. Ductwork may become damaged by moisture from ground contact. A competent heating contractor should check all ductwork and properly correct or replace ductwork as needed.
Ductwork
Properly replace or repair duct system as needed to adequately heat and cool all finished areas.
Gas
Gas Fuel Piping
Natural gas piping observed at inspected property.
Properly maintain gas piping as needed for function and safety.
Installation Issue: Sediment Trap
Installation Issue: Utility Red Tag
Gas Piping was ready for proper correction. Properly correct gas piping where needed.
- Sediment trap for gas piping to furnace was not visible.
Furnace
A Gas Utility Company 'Red Tag' was observed during inspection. Verify conditions causing utility company to issue this 'Warning' have been properly corrected before occupying home. Make any proper corrections as needed to ensure system is fully functional and safe. Properly remove Gas Utility Company 'Red Tag' when safe to do so.
- Red tag provided by utility was not legible. Contact utility company.
- Gas was on to furnace.
Gas Appliance Flue
Flue
Flue: Power Venter Placement
Furnace Flue
Gas appliance metal flue needed correction.
The gas appliance chimney flue had an installed electric powered vent fan to exhaust the gas appliance flue gases to the exterior atmosphere. This electric fan should be as close to the exit point of the flue at the exterior wall as possible for safety. The installed fan appeared father away from the flue exit point than expected. A fan installed too far away from this area can blow carbon monoxide into living space if the flue is not sealed properly. A competent heating technician should further evaluate and properly correct the gas appliance flue as needed for safety and function.
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment is most often one or more installed breaker panels and the branch wiring runs to all equipment, receptacles, lighting outlets and devices such as the light switches. The inspection report focuses on wiring operating between 100-250 Volts. While system Amperage and Voltage is recorded, it is not measured during inspection. Most low voltage wiring is excluded from the performed inspection. Low voltage items such as a heating and cooling thermostat are operated in order to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify each lamp or bulb is appropriate for the installed lighting fixture. The inspector recommends that you review the bulb or lamp installations for each fixture correcting as needed for safety and function. Common errors include 100 watt bulbs installed in fixtures rated for 60 watt max bulbs and interior rated bulbs installed at exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. Most, if not all, electrical corrections should be considered a safety concern.
ELECTRICAL SERVICE
System Amperage and Voltage, identified but not measured: 200 Amps - 120/240 Volts
Electrical Service Type: Overhead
Aerial: Service Tall Above Roof
Electrical Service
Observed electrical service should have unobstructed, dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel.
This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to electrical service.
Electrical Service
Electrical service mast extended farther above roof than expected.
Mast may require bracing or other correction. Further evaluation is recommended for this area. Contact governing authority such as municipality or competent electrical contractor. Properly correct if necessary.
MAIN PANEL
Main Electrical Panel
Routine Correction Needed
Electrical Panel
Routine corrections were needed at electrical distribution panel.
These corrections should be performed now or may be scheduled with other electrical work if having that work done in the near future.
- For panel directory, properly index or label each electrical panel circuit as needed for clarity and safety.
- Multiple neutral wiring was observed under a single lug inside panel. Separate each neutral wire to individual lugs where needed.
- White wires observed attached to 240V breakers. Remark or correct improperly colored wiring inside electrical panel where needed for service personnel safety.
Location Issue: Main Disconnect Not Near Service
The main electrical disconnect was not located near the electrical service. This modern requirement is to assist firefighters and other personnel to more quickly disconnect the electrical power to the building when needed. Evaluate your risk exposure considering an upgrade for this issue.
Branch Wiring
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
AFCI
AFCI Residential
What is Arc Fault Circuit Interrupter (AFCI) Protection?
AFCI protection is designed to break the electrical circuit when it detects electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Most, but not all, homes will have a need for additional AFCI protection based on varied municipal enforcement and the numerous changes for which areas require AFCI protection. Evaluate your risk exposure. Consider adding AFCI protection where needed for improved safety, particularly where construction was completed 2002 or later.
Modern Locations Where AFCI Protection is Known to Improve Safety:
Dwelling Units. All 120-volt, single-phase, 10-, 15-, and 20-ampere branch circuits supplying outlets or devices installed in the following locations:
Kitchens, Family Rooms, Dining Rooms, Living Rooms, Parlors, Libraries, Dens, Bedrooms, Sunrooms, Recreation Rooms, Closets, Hallways, Laundry Areas, or similar areas.
Testing AFCI Function
The inspector uses push button at AFCI breakers, where installed, to confirm AFCI protection trips. Once tripped, the inspector checks indexed electrical circuits to determine where AFCI protection is present or missing.
Obvious locations lacking AFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired AFCI receptacles or breakers are listed in the summary of the report. Evaluate your risk exposure.
No AFCI Built Before 2002
Areas That Did Not Appear AFCI Protected
No AFCI protection was observed at inspected property. AFCI protection is not expected for homes built before 2002. If installation of AFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI
GFCI Residential
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Dwelling Units.
(A) Dwelling Units
All 125-volt through 250-volt receptacles installed in the following locations and supplied by single phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.
(3) Outdoors
(4) Crawl spaces - at or below grade level
(4) Basements
(5) Kitchens
(6) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(7) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Boathouses
(9) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(10) Laundry areas
(12) Indoor damp and wet locations
Some exceptions apply, see current standard for a list of exceptions.
(B) Pertains to Other Than Dwelling Units
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
(F) Outdoor Outlets. For dwellings, all outdoor outlets, including outlets installed in the following locations, and supplied-by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, shall be provided with GFCI protection:
(1) Garages that have floors located at or below grade level.
(2) Accessory buildings
(3) Boathouses
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Older Home
GFCI protection was ready for upgrade at older inspected property. Consider modernizing electrical installation adding this shock protection for all electrical areas where GFCI protection is known to improve safety. If installation of additional GFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI: Redundant Protection
Two GFCI electrical receptacles at kitchen serving counter left of sink were redundant to GFCI electrical receptacle at kitchen serving counter right of sink. Redundant GFCI protection was observed during inspection. While this is not a defect in itself, the occupant should know that redundant protection is present and where redundant devices are to avoid extended loss of use of electrical receptacle or needless electrical service calls.
Receptacle Outlets
Receptacle Appeared Missing: Cooling Unit, Heating Unit
Electrical Receptacle Outlet
An electrical receptacle was not observed near the cooling condensing unit at exterior.
Equipment requiring periodic servicing should have a permanent electrical receptacle installed close by. Consider properly adding an electrical receptacle at exterior ground level within 25 feet of cooling condensing unit to service this equipment.
Electrical Receptacle Outlet
An electrical receptacle was not observed near the heating unit.
Equipment requiring periodic servicing should have a permanent electrical receptacle installed close by. Consider properly adding an electrical receptacle within 25 feet of heating unit to service this equipment.
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Install proper cover plates where needed at exterior.
- Some electrical receptacles were observed inoperative such as at right exterior.
- Properly correct loose electrical receptacles and loose electrical receptacle junction boxes where needed.
An electrical contractor should check all receptacles making functional and safe where needed.
Three Wire Receptacles
Three Wire 240V Receptacles Observed
Some older 240V 3 wire electrical receptacle circuits were observed. Typically, these circuits would serve electric clothes dryers or electric kitchen ranges but may also serve other areas. Evaluate your risk exposure and consider upgrade replacement of any 240V 3 wire receptacle circuits where present with a modern 240V 4 wire receptacle circuits for improved safety. Properly maintain older 240V 3 wire receptacle circuits to meet your needs and for safety, if not upgrading older circuits now.
Lighting/Ceiling Fans
Photo Cell
Photo cell was installed at some exterior light fixtures. Fixtures with photo cells are designed to operate after dark. Verify such lighting fixtures operate properly or correct as needed for function and safety.
Lighting
Service lighting was missing for Furnace at Crawl Space.
- Existing lighting at area did not properly illuminate service area for appliance and additional lighting should be installed.
Equipment requiring periodic servicing should have permanent lighting installed near such equipment that illuminates the control side of the equipment. This service lighting should be controlled by a switch that is installed at the entry point to the area where the equipment is installed. Consider properly adding additional lighting where needed near such equipment for improved safety and to facilitate servicing equipment when needed.
Lighting/Ceiling Fans
Correct Lighting Where Needed
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some light fixtures were improperly installed.
- Some ceiling fans needed correction.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
Smoke Alarms
Smoke Alarm Installation: Where Should Smoke Alarms be Installed?
Depending on the age and location of the home, installation of smoke alarms are either recommended or required for improved safety.
Modern smoke alarm systems typically are hardwired to the electrical system and will have battery backup so that they will function when the power is off to the building. Modern smoke alarm systems typically have all smoke alarms interconnected so that when one alarm sounds then all smoke alarms will sound simultaneously. This is useful for heavy sleepers and in larger homes.
Modern smoke alarm systems typically have smoke alarms installed at the following locations:
- In the immediate vicinity outside sleeping areas
- Inside sleeping areas
- At least one per floor level including basements
- Near stairs
- In unfinished basements
- (some installations will require additional smoke alarms)
It is important to note that a single smoke alarm can satisfy multiple areas if carefully placed.
It is common to have a single smoke alarm near the top of the stairs and just outside multiple sleeping areas.
Properly maintain smoke alarm system as needed for life safety.
Regarding Testing Smoke Alarms:
Test smoke alarms weekly to ensure proper function for life safety. Replace batteries when needed. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
The inspector does not test smoke alarms. For safety, the inspector only accesses smoke alarms from the installed flooring. To prevent damage, the inspector does not remove smoke alarms or open smoke alarm covers.
Modernize
Smoke alarms were not present for all areas where now recommended or required.
Installation of additional smoke alarms is recommended.
- Inside sleeping rooms
- Outside sleeping area
Evaluate your risk exposure. Upgrade smoke alarms to meet your needs and for life safety.
Read and follow the smoke alarm manufacturer installation and operating instructions.
Contact your local Fire Marshal if need be.
Battery Removed, BATTERY POWERED Smoke Alarm Older
One or more battery-powered smoke alarms appeared older.
Inspector does not confirm date of manufacture or operate smoke alarms when inspecting installed smoke alarms.
Smoke alarms older than ten years should be replaced. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
Required Reporting by the State of Tennessee
The home inspector shall report:
If battery-powered smoke alarms appear more than ten (10) years from the date of manufacture, a request by the owner for that type of device shall be directed to the State Fire Marshal's Office.
ATTIC LADDER
Installation / Condition
Overall Condition: Attic Ladder Correct Before Use, Consider Upgrade
If pull down attic ladder stairway is used frequently you may consider upgrading to one with locking aluminum adjustable steps for safety. Werner brand makes this type of pull down attic ladder stairway and these are sold at big box stores and available online. Pull down attic ladder stairway should be properly installed for safety.
Attic ladder was observed ready for corrections now and before use to improve the function and safety aspects of the attic ladder.
Refer to the full report for additional information and photos regarding obvious corrections recommended now for the attic ladder area. A competent qualified contractor capable of reading and following the manufacturer installation instructions should check all attic ladder areas. Make attic ladder functional, safe and structurally sound where needed.
STRUCTURE
Commentary
CANDIDATE FOR DEMOLITION
Home was a candidate for demolition if proper structural repairs, needed now, are not feasible.
Obtain competitive bids for all work needed.
Obtain further evaluation for areas as instructed.
Attic Access
Pull down attic ladder stairway, properly maintain unit as needed for safety
Attic Access: Not Floored
Attic area viewed from access point only due to lack of walk boards. Some areas of attic may not have been viewed.
Roof Framing
Framing: Rafters, Wooden
Sheathing: Wood Boards
Roof Framing
Further evaluation of roof framing system was needed. Conditions observed at roof framing that warrant further evaluation by a specialist. A competent qualified contractor should further evaluate entire roof framing system and all supports determining corrective measures needed, take action to prevent recurrence and properly repair affected areas where needed.
- Representative Photos Provided
- Some roof framing was damaged and unrepaired.
- Some roof framing was outdated or improper.
- Irregular alterations to roof framing were apparent.
- Replace or correct roof framing to make area structurally sound.
Roof Framing
Coordinate roof framing corrections needed now in conjunction with roof covering corrections needed now.
Ceiling Framing
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector.
Wall Framing
Framing Access: Finished Prevented
Finished areas prevented view of structural components. Structural areas were not observed by inspector. Concealed areas are not part of the inspection performed.
Underfloor Access
Crawl Space: Ductwork, Insulation, Limited Access
Visibility or access limited at crawl space due to installed ductwork.
Visibility was limited due to installed insulation in this area.
The inspector enters readily accessible crawl space areas where the overall height is at least 24" and there is an unobstructed crawl path height of at least 16". The inspected property did not meet these criteria. Areas of crawl space with limited access were not accessed by inspector.
Underfloor Description
Attributes: Crawl Space Throughout
Underfloor Area
Access:
- Crawl space entered through hinged door
Construction Type:
- Crawl Space
Foundation:
- Concrete Block
Columns or Piers:
- Concrete Block
Floor Structure:
- Floor Joists - Solid Wood
- Beam - Wood
- Subfloor - Wood
Floor System
Floor Framing and Supports
Conditions observed at floor system that warrant further evaluation by a specialist.
A competent qualified contractor should further evaluate entire floor system and all supports determining corrective measures needed, take action to prevent recurrence and properly repair affected areas where needed. Making corrections for areas where needed now would help reduce predictable unnecessary settlement of structure.
- Representative Photos Provided
- Floor framing was outdated or improper.
- Some floor framing was damaged and unrepaired.
- Some floor framing was damaged and partially repaired.
- Older foundation observed in need of corrections.
- Shoring or strengthening measures observed were irregular.
- Obvious preventable load path settlement had occurred and proper correction is recommended.
- Flooring was noticeably out of level at multiple areas.
- Further evaluation should include a load path analysis for the structure.
- Replace or correct floor framing, foundation and supports to make area structurally sound.
Other Concerns
Construction Debris, Suspect Termites
Construction debris, undesirable debris or excess debris was observed at crawl space area. Remove unnecessary debris and any wood scraps from crawl space area. Do not forget to check beneath plastic sheeting on the ground too, if installed.
Suspect termite activity observed.
The inspector recommends further evaluation by a specialist properly correcting as needed. An exterminator is needed to determine if termite presence is active or not. Often termite activity is related to a moisture condition. Properly correct any undesirable moisture conditions as needed.
INSULATION
Above Ceiling Insulation
Recommended Insulation
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Observed Insulation Approximate Depth: R - 19
Consider Improving Insulation: Missing, Energy Audit Recommended
Insulation was missing at some areas. Inspector recommends insulation be properly installed where missing to lower utility costs.
Consider obtaining evaluation by an energy auditor for property to improve energy efficiency and comfort.
Wall Insulation
Insulation: Wall Insulation Not Observed, Undetermined
MOISTURE
Crawl Space Underfloor
Crawl Space: Practical Steps Crawl Space Moisture
Practical steps to better moisture condition at a typical crawl space after ensuring no possible plumbing leaks into crawl space are present.
- Properly divert any storm water and all gutter down spouts a minimum 10 feet away from foundation.
- Correct any exterior grading issues that prevent storm water from flowing away from foundation.
- Improve air flow through crawl space to provide proper cross ventilation.
- Improve crawl space dirt floor vapor retarder to help keep moisture at soil.
- Properly drain any excess bulk moisture from crawl space, if present, to prevent accumulation.
- Take more aggressive steps if necessary such as installing a dewatering system and proper encapsulation of crawl space with conditioned air space.
Vapor Retarder
Plastic sheeting, vapor retarder, covering soil areas inside the underfloor crawl space was ready for replacement.
A vapor retarder is an important measure to reduce moisture inside underfloor crawl spaces. Properly remove any debris from crawl space and replace vapor retarder for improved moisture control at crawl space area.
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Ridge Roof Vent, Gable End Vent
Attic Intake Vents: Soffit Vents Missing
Consider adding low intake vents such as soffit vents to provide proper cross ventilation.
Foundation Ventilation at Underfloor Crawl Space
Info Crawl Space Ventilation
Regarding underfloor crawl space ventilation.
Crawl spaces either should be properly ventilated or properly encapsulated. Encapsulated crawl spaces must have a conditioned air space. When ventilating a crawlspace it is important to have proper intake and exhaust venting to provide adequate cross ventilation. Monitor crawl space air for excess moisture and condensation properly correcting if necessary to meet your needs.
Foundation Vents Should Be Open
Regarding closing foundation vents at ventilated crawl spaces in the Greater Chattanooga Metropolitan Area.
- Foundation vents at ventilated crawl spaces should NEVER be closed seasonally such as leaving crawl space vents closed ALL WINTER.
- Foundation vents at ventilated crawl spaces should be CLOSED if outdoor temperature is BELOW 25 degrees f.
- Foundation vents at ventilated crawl spaces should be OPEN if outdoor temperature is ABOVE 32 degrees f.
Foundation vents at ventilated crawl spaces should be open when the outdoor temperature is above freezing. If you feel you must close the foundation vents, they should only be closed for very low temperatures and then promptly reopened when the outdoor temperature rises above freezing. Our moderate climate for this area is known for outdoor temperatures typically being in the 40s to 60s f during the day in the winter. Leaving the foundation vents closed for weeks or months, in some instances, may damage the floor framing due to excess humidity and fungal growth.
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof
Roof Style: Multi Plane
Approximate Age of Roof Covering: 4-8 Years
Roofing Material: Composition Dimensional Shingle
Coordinate Roof Covering with Roof Framing
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Flashing appeared omitted at areas. Properly add flashing where needed.
- Remove vegetation debris from roofing where needed.
- Vegetation on roof covering concealed view of areas.
- Roof framing was sagging and in need of correction to properly support dimensional shingles..
- Some shingles observed damaged.
Roof Covering
Coordinate roof covering corrections needed now in conjunction with roof framing corrections needed now.
Gutters and Downspouts
Gutter and Downspout Materials: Metal
Best Time to Replace
The best time to replace guttering is while you are having the roof covering replaced.
Observation:
Downspout: Near
Gutters: Cleaning Excess Debris, Replace or Repair
The gutters were viewed with debris in them and some downspouts may be obstructed. Although this is a maintenance item, the condition viewed may cause damage to the soffits or fascia and should be corrected soon. Properly correct gutters as needed for proper function.
Replace or repair gutters as needed for proper function.
SIDING and TRIM
Siding - Metal
Metal Siding: Corrections Needed
Exterior siding was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Failing Paint Observed
- Physical Damage Observed
- Trim Was Missing at Areas
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
Trim
Trim Material: Wood where installed
Trim: Corrections Needed
Exterior trim was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Failing Paint Observed
- Physical Damage Observed
- Rot Observed
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance.
LOTS and GROUNDS
Driveway
Walkway
Porch
Stairs and Railings at Exterior
Diagram: Older Railing & Stairs
Railings and Stairs at older home as expected, did not meet current safety standards. Railings and stairs were ready for modernization for improved safety. Evaluate your risk exposure. Consider proper repair or replacement of stairs and railings where needed now for safety and function.
Stairs: Deferred Maintenance
Stairs suffered from deferred maintenance and were ready for reconditioning.
Vegetation
Vegetation Maintenance, Overgrown Shrubs, Climbing Vegetation, Overhanging Branches, Dead Limbs
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Shrubs or other vegetation appeared too close to the exterior walls and can transfer unwanted moisture that may be detrimental to building components. Review vegetation correcting where needed. Consider having enough separation between plants and exterior walls so that you can walk as this allows air circulation and improves access for home maintenance. Areas concealed by overgrown vegetation were not observed by inspector.
Ivy or other climbing vegetation was noted. The vegetation should be properly removed as it may cause damage to building components. Areas concealed by vegetation were not inspected. Repair any affected areas damaged by vegetation if present.
Overhanging tree branches appeared too close above roofing. Air circulation and sunlight help prevent deterioration of roof components. Branches should be properly trimmed back to alleviate this condition.
Dead tree limbs were noted and should be properly removed.
Site
Site: Negative Drainage
Drainage was negative, which means water will flow toward the structure. In order to correct this condition, it may be necessary to alter the grade by lowering or raising the immediate grade to divert water away from the building a minimum of ten feet. Other corrections may also be needed. Monitor storm water runoff during and after rains. Make appropriate corrections to meet your needs.
Retaining Wall
Retaining Wall
End of Report
Thank You Note
Thank you so much for trusting me to perform your inspection!
Please reach out if I may assist you further.
Roger Williamson
423-301-1000
HomePro Inspection.com