How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Further Evaluation:Observations listed as further evaluation need a more extensive or technically exhaustive evaluation and warrant further investigation by a specialist. For areas where corrections may not be straight forward or where a proper plan should be developed to implement corrections, then further evaluation is recommended. To obtain further evaluation is to hire a specialist that is highly experienced in the repair or correction of a specific item or area. Some observations listed under other labels that also require further evaluation will appear under the other label only. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Routine Correction Needed:Observations listed as routine correction need repair or correction and are not unusual for the type and age property inspected. These routine items are typically not recurring and once properly corrected should not require repetitive correction. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- K-1 KITCHEN:
Location Kitchen Duplex Left Side
Sink Faucet
Leak observed at throat of faucet.
Properly repair faucet for correct function.
- K-2 KITCHEN:
Range Duplex Left Side
Clearance appeared improper above cook surface.
Most ranges and cooktops require a minimum 30" clearance to combustibles above cook surface for fire safety. Refer to installation instructions and provide proper clearance or properly relocate cooking appliance as needed for safety and function.
- K-3 KITCHEN:
Range Duplex Right Side
Clearance appeared improper above cook surface.
Most ranges and cooktops require a minimum 30" clearance to combustibles above cook surface for fire safety. Refer to installation instructions and provide proper clearance or properly relocate cooking appliance as needed for safety and function.
- K-4 KITCHEN:
Cooktop Duplex Right Side
Cooktop left front eye did not come on when turned on at selector switch. Right rear eye came on but did not heat up properly.
The cooking surface was inspected and found inoperative when using the normal operating controls. Properly put the cooktop back in service correcting as needed for function and safety.
- B-1 BATHROOM:
Location Full Bathroom Duplex Right Side
Toilet
The toilet was loose at the floor and should be properly repaired for function and safety.
Corrections were needed for the toilet. Loose toilets can cause leakage and floor damage.
- B-2 BATHROOM:
Location Full Bathroom Duplex Right Side
Area: Bathing Faucet
Faucet was loose.
Properly secure faucet as needed. Properly correct any affected areas if present.
- P-1 PLUMBING:
Multiple exterior hose faucets need correction.
Check all exterior hose faucets properly correcting where needed.
- Two hose faucets observed missing handles and were inoperative when inspected.
- P-2 PLUMBING:
Water Heater Duplex Left Side
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Water heater did not have reasonable service access.
- P-3 PLUMBING:
Water Heater Duplex Right Side
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Water heater did not have reasonable service access.
- E-1 ELECTRICAL:
Sub Breaker Panel Bathroom, consider upgrade, Duplex Left Side
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
- E-2 ELECTRICAL:
Sub Breaker Panel Bathroom, consider upgrade, Duplex Right Side
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
- E-3 ELECTRICAL:
Branch Wiring Attic
Improper wiring was observed at attic.
Properly correct any improper wiring where needed for function and safety.
- E-4 ELECTRICAL:
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Some electrical receptacles tested hot/neutral reversed.
- Some electrical receptacles tested open ground.
- Some electrical receptacles were observed damaged.
- Install proper cover plates where needed at interior.
- Properly correct loose electrical receptacles where needed.
An electrical contractor should check all receptacles making functional and safe where needed. Photos and video provided.
- E-5 ELECTRICAL:
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were damaged.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
- R-1 ROOF:
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles observed worn.
- Some shingles observed damaged.
- Some shingles had temporary repairs.
- Some shingles did not lay flat. Correct shingles and/or roof decking as needed.
- Remove vegetation debris from roofing where needed.
- Vegetation on roof covering concealed view of areas.
- Vegetation debris on roof covering concealed view of areas.
- R-2 ROOF:
Consider replacement of all roofing.
Weigh your options for repairing roof covering now and proper complete roof covering replacement now to determine which is the possible better long term solution for your situation. Considering that a properly replaced roofing system may last up to three decades it may make better sense to replace the roofing correctly now rather than to repair an aging roof system.
- R-3 ROOF:
Roof Covering
Coordinate roof covering corrections needed now in conjunction with roof framing corrections needed now.
Further Evaluations
- P-4 PLUMBING:
Multiple plumbing corrections were needed.
A Licensed Competent Plumbing Contractor should further evaluate entire plumbing system. Properly repair or replace plumbing system as needed to make system fully functional and safe.
- S-1 STRUCTURE:
Damaged Engineered Roof Truss was observed unrepaired. Representative Photos Provided
To repair damaged roof truss framing:
- Obtain further evaluation to verify all areas where damage is present at roof trusses.
- Contact roof truss manufacturer or other State Licensed Professional Engineer to design appropriate corrections.
- A competent qualified contractor should execute engineering design where needed.
- Retain stamped engineering design drawing for your permanent records.
- One truss appeared with damage that likely should have been corrected at the factory.
- At least two trusses were observed damaged to accommodate plumbing and were left unrepaired.
- One or more roof trusses were observed damaged from roof covering leakage and were left unrepaired.
- S-2 STRUCTURE:
Roof Framing
Coordinate roof framing corrections needed now in conjunction with roof covering corrections needed now.
The Full Report
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Doors
Glazing/Glass
Windows
MAIN LEVEL PHOTOS
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Exterior Hose Faucets
Water Heater
Water Heater
Equipment Observed
Plumbing Other
ELECTRICAL
Electrical Inspection
ELECTRICAL SERVICE
System Amps / Volts
MAIN PANEL
SUB PANEL
SUB PANEL
Branch Wiring
AFCI
GFCI
Receptacle Outlets
Three Wire Receptacles
Lighting/Ceiling Fans
Switches
Smoke Alarms
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Home Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Duplex
Site Built
Approximate Square Footage: 1834, 1814
Approximate Year of Original Construction: 1972, 1961
Weather during the inspection: Cloudy
Ground/Soil surface conditions: Dry
Approximate Low Temperature During Inspection: 65[F]
Approximate High Temperature During Inspection: 75[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Furniture, Property, Rugs, Empty of Furnishings
Left Unit
Access and visibility was limited at interior areas as furnishings, personal property and area rugs were present at left unit.
Right Unit
Home was empty of furnishings when inspected.
________________________________________________________________________________________________________________________________________________________________
Ceilings
Interior Ceiling Materials: Drywall
Interior Ceiling Condition:
- Some settlement type cracking observed.
- Wear and damage observed, budget reconditioning
________________________________________________________________________________________________________________________________________________________________
Walls
Interior Wall Materials: Drywall
Interior Wall Condition:
- Some settlement type cracking observed.
- Wear and damage observed, budget reconditioning
________________________________________________________________________________________________________________________________________________________________
Flooring
Interior Flooring Materials: Engineered Flooring, Vinyl Tile
Interior Flooring Condition:
- Wear and damage observed, budget reconditioning
Doors
Doors at Interior: Blocked
Doors Correct as Needed, Doors Replace Repair
Replace, repair or upgrade interior doors to meet your needs. Properly correct any affected adjacent areas, if present.
________________________________________________________________________________________________________________________________________________________________
Replace, Repair, Check All
Replace, repair or upgrade doors to exterior to meet your needs. Properly correct any affected adjacent areas if present. Check all doors to exterior properly making doors functional, secure and weather tight to meet your needs.
Glazing/Glass
Insulated glass was present.
Single pane glass was present.
Cracks / Breakage: Broken
Broken window glass should be replaced for safety and to reduce conditioned air loss. Replace any broken or cracked glass as needed.
Windows
Metal framed windows were present.
Vinyl framed windows were present.
Escape and Rescue, Screens
Consider upgrade for escape and rescue window openings.
Window for one or more possible sleeping areas did not appear to meet modern safety standards for an emergency escape or a rescue opening from a sleeping room. Evaluate your risk exposure correcting or making contingency measures as needed. Consider this area for appropriate upgrade or improvement.
Window screens are not required on homes with central cooling system air conditioning. Install window screens where missing, if desired.
Older Windows, Original Windows
Older windows often have been neglected and may not operate as intended. Check all windows properly correcting where needed.
The building appeared to have at least some of the original windows installed during construction. Windows are now available that are more efficient to reduce energy usage and improve comfort level inside home. Consider upgrading if desired.
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following builtin kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area: Left
Kitchen Duplex Left Side
Countertop: Laminate
- Wear noted, properly recondition to meet your needs
Cabinets: Wood painted
- Wear noted, properly recondition to meet your needs
Floor Covering: Vinyl Tile
- Wear noted, properly recondition to meet your needs
Sink: Double Bowl Stainless Steel
Disposal: Not Present
Dishwasher: Not Present
Range: Range (Electric Top/Oven)
Present and On/Off Tested functional
Microwave: Portable unit not evaluated
Kitchen Exhaust: Not Present
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Range Duplex Left Side
Clearance appeared improper above cook surface.
Most ranges and cooktops require a minimum 30" clearance to combustibles above cook surface for fire safety. Refer to installation instructions and provide proper clearance or properly relocate cooking appliance as needed for safety and function.
Kitchen
Kitchen Area: Right
Kitchen Duplex Right Side
Countertop: Laminate
- Wear noted, properly recondition to meet your needs
Cabinets: Wood painted
- Wear noted, properly recondition to meet your needs
Floor Covering: Peel and Stick Vinyl Tile
- Wear and damage observed, budget reconditioning
Sink: Double Bowl Stainless Steel
- No leaks were viewed at faucet or visible supply lines or waste drain just beneath the sink.
- Signs of past leakage observed. Maintain area to meet your needs.
Disposal: Not Present
Dishwasher: Present
Range: Range (Electric Top/Oven)
Oven On/Off Tested Functional
Microwave: Not Present
Kitchen Exhaust: Not Present
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Range Duplex Right Side
Clearance appeared improper above cook surface.
Most ranges and cooktops require a minimum 30" clearance to combustibles above cook surface for fire safety. Refer to installation instructions and provide proper clearance or properly relocate cooking appliance as needed for safety and function.
Cooktop Duplex Right Side
Cooktop left front eye did not come on when turned on at selector switch. Right rear eye came on but did not heat up properly.
The cooking surface was inspected and found inoperative when using the normal operating controls. Properly put the cooktop back in service correcting as needed for function and safety.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom 1
Full Bathroom
Location Full Bathroom Duplex Left Side
Bathing Area: Combination tub and shower
- No leaks were observed around faucet and the water containment area appeared serviceable.
Hand Washing: Vanity with basin
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
- Signs of past leakage observed. Maintain area to meet your needs.
- Personal property beneath sink restricted view of area.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested operative. Consider exhausting to exterior if needed.
- Window present to ventilate bathroom.
Floor Covering: Vinyl Tile
- Wear noted, properly recondition to meet your needs
Bathing Area: Tub (Tub Spout Not Flush)
Space Heater: Functional
Location Full Bathroom Duplex Left Side
Bathroom Space Heater observed functional, properly maintain unit for safety and function.
Bathroom 2
Full Bathroom
Location Full Bathroom Duplex Right Side
Bathing Area: Combination tub and shower
Hand Washing: Vanity with basin
- Signs of past leakage observed. Maintain area to meet your needs.
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
Ventilation:
- Window present to ventilate bathroom.
Floor Covering: Vinyl Tile
- Wear noted, properly recondition to meet your needs
Location Full Bathroom Duplex Right Side
Toilet
The toilet was loose at the floor and should be properly repaired for function and safety.
Corrections were needed for the toilet. Loose toilets can cause leakage and floor damage.
Location Full Bathroom Duplex Right Side
Area: Bathing Faucet
Faucet was loose.
Properly secure faucet as needed. Properly correct any affected areas if present.
LAUNDRY
Laundry Connections
Laundry: Appliances Present
Laundry appliances were present during inspection.
Laundry appliances restricted view of laundry connections. Laundry appliances typically do not convey with property. Laundry appliances are not evaluated during inspection. Laundry faucets are not operated when appliances are connected to faucets. Verify your clothes dryer exhaust is functional, safe and properly installed to meet the requirements of clothes dryer manufacturer in use.
PLUMBING
Supply Piping
Supply Piping: Copper visible, other materials not viewed could be present
Galvanized Steel Piping: Some Galvanized Steel Plumbing Fittings Were Observed
Waste Piping
Waste Piping: Functional Flow Plastic
Material: Plastic
Functional waste water flow observed during inspection for water outlets operated.
Apparent Vent Piping
Plastic - No Adverse
Material: Plastic
No adverse conditions were observed, maintain to meet your needs.
Exterior Hose Faucets
Water Heater
Access: No Reasonable Access View Limited
Water Heater Duplex Left Side
Water heaters should be readily accessible for routine servicing and inspection. The installed water heater did not have reasonable access and proper correction is recommended. The restricted access to the water heater limited the visible evaluation of this area.
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior type areas have contingency measures installed to mitigate expected leakage or rupture of water heater.
Such measures would collect and drain unwanted water to exterior to avoid damaging interior finishes. Consider upgrading water heater installation to help reduce unnecessary damage when the water heater leakage occurs.
Water Heater Duplex Left Side
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Water heater did not have reasonable service access.
Water Heater
Access: Area Not For Storage
Access: Concealed
Water Heater Duplex Right Side
Water heater, likely area, appeared concealed when inspected. Water heater installation did not have reasonable access for servicing or inspecting system. Inspector was unable to fully evaluate water heater installation nor was area around the water heater observed for leaks when inspected. Create proper access to water heater area. Have system installation evaluated properly correcting as needed.
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior type areas have contingency measures installed to mitigate expected leakage or rupture of water heater.
Such measures would collect and drain unwanted water to exterior to avoid damaging interior finishes. Consider upgrading water heater installation to help reduce unnecessary damage when the water heater leakage occurs.
Water Heater Duplex Right Side
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Water heater did not have reasonable service access.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Missing
A plumbing thermal expansion tank was not observed near the water heater.
Monitor this area for leaks adding an expansion tank if needed.
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Unknown
Plumbing Supply Piping
A plumbing system pressure reducer was not located.
Verify location of installed pressure reducer or add as needed, if needed.
________________________________________________________________________________________________________________________________________________________________
Property Owner - Plumbing Supply Piping - MAIN WATER SHUT OFF VALVE - Apparent Location - Note Such Valves are Not Operated : Water Shut off Not Observed, unknown if present
Plumbing Other
Multiple plumbing corrections were needed.
A Licensed Competent Plumbing Contractor should further evaluate entire plumbing system. Properly repair or replace plumbing system as needed to make system fully functional and safe.
CENTRAL SYSTEM
Central Heat/Cool
Not Present
Central Heating/Cooling
Central heating and cooling was not present during inspection. Install proper heating and cooling to meet your needs.
Space Heating
Space Heater
Fuel: Electric
Type: Baseboard heater
Function: Appeared Functional
Five baseboard heaters were observed; two at left unit, three at right unit.
Each unit was on/off tested and appeared functional. Properly maintain units as needed for function and safety.
Space Heat/Cool
Space Heating/Cooling
Space Cooling
Space Cooling
Type: Portable Cooling Unit
Portable cooling units are considered personal property and are not evaluated.
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment is most often one or more installed breaker panels and the branch wiring runs to all equipment, receptacles, lighting outlets and devices such as the light switches. The inspection report focuses on wiring operating between 100-250 Volts. While system Amperage and Voltage is recorded, it is not measured during inspection. Most low voltage wiring is excluded from the performed inspection. Low voltage items such as a heating and cooling thermostat are operated in order to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify each lamp or bulb is appropriate for the installed lighting fixture. The inspector recommends that you review the bulb or lamp installations for each fixture correcting as needed for safety and function. Common errors include 100 watt bulbs installed in fixtures rated for 60 watt max bulbs and interior rated bulbs installed at exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. Most, if not all, electrical corrections should be considered a safety concern.
ELECTRICAL SERVICE
System Amps / Volts
System Amperage: Two 100 Amp panels
System Voltage: 120/240 Volts
MAIN PANEL
Main Electrical Panel
Service Entrance Conductors: Aluminum, Stranded
Panel Inspected
The electrical panel cover was removed from the electrical distribution panel. The interior components were viewed and found to be in satisfactory condition and appeared to be properly installed. No repairs were needed to electrical panel or interior components when inspected.
SUB PANEL
Sub Electrical Panel
Index: Index
Access: Area Not For Storage, Working Access
Observed electrical equipment panel should have unobstructed dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel. This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to the electrical panel.
Location Issue: Bathroom
Wiring: Remark White 240V Breaker
Wiring: Relocate Low Voltage Wiring
Wiring Sub Panel: 4 Wire Needed, 4 Isolate
Breaker: Breaker ON in Down Position
Upgrade: Distribution Equipment Upgrade Recommended
In the inspector's opinion, now is the time to consider an electrical upgrade for the distribution electrical equipment. Updating this older equipment properly will improve safety and convenience.
Sub Breaker Panel Bathroom, consider upgrade, Duplex Left Side
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
SUB PANEL
Sub Electrical Panel
Index: Index
Location Issue: Bathroom
For safety and access a breaker panel should not be installed inside a bathroom. Appropriate correction is recommended.
Wiring: Remark White 240V Breaker, Remark Wiring, Neutral Multiple Lugged
Wiring: Relocate Low Voltage Wiring
Breaker: Handle Tie Missing 240 V, Breaker ON in Down Position
Upgrade: Distribution Equipment Upgrade Recommended
In the inspector's opinion, now is the time to consider an electrical upgrade for the distribution electrical equipment. Updating this older equipment properly will improve safety and convenience.
Sub Breaker Panel Bathroom, consider upgrade, Duplex Right Side
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
Branch Wiring
Material: Aluminum, Solid Conductor
Branch Wiring
The inspector observed solid conductor aluminum wiring in branch circuits. This wiring is no longer used and is controversial because it requires properly listed devices and connectors. Periodic maintenance is also required to ensure safe operation. Monitor this wiring maintaining as necessary.
Wiring Method: Non Metallic Sheathed Cable
Improper Wiring, Service Disconnect Missing
Electrical service disconnect was not observed near water heaters at Kitchen. An electrical service disconnect within view of the permanently installed appliance is an important safety device for personnel servicing equipment. A competent electrical contractor should properly install an electrical service disconnect where missing for safety.
AFCI
AFCI Residential
What is Arc Fault Circuit Interrupter (AFCI) Protection?
AFCI protection is designed to break the electrical circuit when it detects electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Most, but not all, homes will have a need for additional AFCI protection based on varied municipal enforcement and the numerous changes for which areas require AFCI protection. Evaluate your risk exposure. Consider adding AFCI protection where needed for improved safety, particularly where construction was completed 2002 or later.
Modern Locations Where AFCI Protection is Known to Improve Safety:
Dwelling Units. All 120-volt, single-phase, 10-, 15-, and 20-ampere branch circuits supplying outlets or devices installed in the following locations:
Kitchens, Family Rooms, Dining Rooms, Living Rooms, Parlors, Libraries, Dens, Bedrooms, Sunrooms, Recreation Rooms, Closets, Hallways, Laundry Areas, or similar areas.
Testing AFCI Function
The inspector uses push button at AFCI breakers, where installed, to confirm AFCI protection trips. Once tripped, the inspector checks indexed electrical circuits to determine where AFCI protection is present or missing.
Obvious locations lacking AFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired AFCI receptacles or breakers are listed in the summary of the report. Evaluate your risk exposure.
No AFCI Built Before 2002
Areas That Did Not Appear AFCI Protected
No AFCI protection was observed at inspected property. AFCI protection is not expected for homes built before 2002. If installation of AFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI
GFCI Residential
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Dwelling Units.
(A) Dwelling Units
All 125-volt through 250-volt receptacles installed in the following locations and supplied by single phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.
(3) Outdoors
(4) Crawl spaces - at or below grade level
(4) Basements
(5) Kitchens
(6) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(7) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Boathouses
(9) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(10) Laundry areas
(12) Indoor damp and wet locations
Some exceptions apply, see current standard for a list of exceptions.
(B) Pertains to Other Than Dwelling Units
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
(F) Outdoor Outlets. For dwellings, all outdoor outlets, including outlets installed in the following locations, and supplied-by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, shall be provided with GFCI protection:
(1) Garages that have floors located at or below grade level.
(2) Accessory buildings
(3) Boathouses
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Older Home
GFCI protection was ready for upgrade at older inspected property. Consider modernizing electrical installation adding this shock protection for all electrical areas where GFCI protection is known to improve safety. If installation of additional GFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
Receptacle Outlets
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Some electrical receptacles tested hot/neutral reversed.
- Some electrical receptacles tested open ground.
- Some electrical receptacles were observed damaged.
- Install proper cover plates where needed at interior.
- Properly correct loose electrical receptacles where needed.
An electrical contractor should check all receptacles making functional and safe where needed. Photos and video provided.
Three Wire Receptacles
Three Wire 240V Receptacles Observed
Some older 240V 3 wire electrical receptacle circuits were observed. Typically, these circuits would serve electric clothes dryers or electric kitchen ranges but may also serve other areas. Evaluate your risk exposure and consider upgrade replacement of any 240V 3 wire receptacle circuits where present with a modern 240V 4 wire receptacle circuits for improved safety. Properly maintain older 240V 3 wire receptacle circuits to meet your needs and for safety, if not upgrading older circuits now.
Lighting/Ceiling Fans
Correct Lighting Where Needed
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were damaged.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
Smoke Alarms
Smoke Alarm Installation: Where Should Smoke Alarms be Installed?, Additional Smoke Alarms Recommended
Depending on the age and location of the home, installation of smoke alarms are either recommended or required for improved safety.
Modern smoke alarm systems typically are hardwired to the electrical system and will have battery backup so that they will function when the power is off to the building. Modern smoke alarm systems typically have all smoke alarms interconnected so that when one alarm sounds then all smoke alarms will sound simultaneously. This is useful for heavy sleepers and in larger homes.
Modern smoke alarm systems typically have smoke alarms installed at the following locations:
- In the immediate vicinity outside sleeping areas
- Inside sleeping areas
- At least one per floor level including basements
- Near stairs
- In unfinished basements
- (some installations will require additional smoke alarms)
It is important to note that a single smoke alarm can satisfy multiple areas if carefully placed.
It is common to have a single smoke alarm near the top of the stairs and just outside multiple sleeping areas.
Properly maintain smoke alarm system as needed for life safety.
Regarding Testing Smoke Alarms:
Test smoke alarms weekly to ensure proper function for life safety. Replace batteries when needed. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
The inspector does not test smoke alarms. For safety, the inspector only accesses smoke alarms from the installed flooring. To prevent damage, the inspector does not remove smoke alarms or open smoke alarm covers.
Smoke alarms were not present for all areas where now recommended or required.
Installation of additional smoke alarms is recommended.
- Inside sleeping rooms
- Outside sleeping area
Evaluate your risk exposure. Upgrade smoke alarms to meet your needs and for life safety.
Read and follow the smoke alarm manufacturer installation and operating instructions.
Contact your local Fire Marshal if need be.
Not Interconnected, Older Smoke Alarms
Smoke Alarms
Smoke alarms did not appear interconnected together to facilitate simultaneous report. Modern smoke alarm installations will have all smoke alarms sound together when one smoke alarm is tested or indicates smoke is present. Consider this area for upgrade for improved safety.
One or more smoke alarms appear older.
Inspector does not confirm date of manufacture or operate smoke alarms when inspecting installed smoke alarms.
Smoke alarms older than ten years should be replaced. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
STRUCTURE
Attic Access
Attic Access: Scuttle Hole
Attic Access: Not Floored
Attic area viewed from access point only due to lack of walk boards. Some areas of attic may not have been viewed.
Attic Area
Draft Stop:Not Present
No draft stop or fire wall was observed at attic area between dwelling units for multi family dwelling. Properly installed drywall at attic areas between attached dwelling is used to create a draft stop. In case of fire a properly installed draft stop can offer some protection slowing the spread of smoke and fire from one dwelling unit to another. Consider this area for appropriate upgrade or improvement.
Roof Framing
Framing: Trusses, Wooden
Sheathing: Plywood
Roof Framing: Roof Decking Check When Replacing Roof Covering
Truss Framing: Trusses Are Engineered, Lateral Bracing Not Observed
Truss systems are designed, engineered framing systems that are comprised of multiple components. Truss systems are accompanied by specific installation instructions that should be closely followed. Installation instructions are rarely available during a property inspection. Review of instructions, if available, is not part of the inspection performed. Obvious, visible defects are listed in the report, when encountered. Properly maintain truss system to meet your needs.
Damaged Engineered Roof Truss was observed unrepaired. Representative Photos Provided
To repair damaged roof truss framing:
- Obtain further evaluation to verify all areas where damage is present at roof trusses.
- Contact roof truss manufacturer or other State Licensed Professional Engineer to design appropriate corrections.
- A competent qualified contractor should execute engineering design where needed.
- Retain stamped engineering design drawing for your permanent records.
- One truss appeared with damage that likely should have been corrected at the factory.
- At least two trusses were observed damaged to accommodate plumbing and were left unrepaired.
- One or more roof trusses were observed damaged from roof covering leakage and were left unrepaired.
Roof Framing
Coordinate roof framing corrections needed now in conjunction with roof covering corrections needed now.
Ceiling Framing
Truss Framing: Ceiling framing was integral with roof framing trusses where installed.
Wall Framing
Framing Access: Finished Prevented
Finished areas prevented view of structural components. Structural areas were not observed by inspector. Concealed areas are not part of the inspection performed.
Underfloor Access
Slab: Finished Areas
Finished areas prevented view of structural components. Structural components were not observed by inspector at such areas.
Underfloor Description
Slab: Elevated
Access:
Slab construction no underfloor area present
Construction Type:
Concrete Slab Elevated
Foundation:
Concrete Block or Poured in Place Concrete
Columns or Piers:
Not Applicable
Floor Structure:
Concrete Slab Floor
Floor Insulation:
Not Applicable
INSULATION
Above Ceiling Insulation
Recommended Insulation, Insulation Photo
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Insulation Type: Blown In
Observed Insulation Approximate Depth: R - 19, R - 13
Consider Improving Insulation: Energy Audit Recommended, Missing
Consider obtaining evaluation by an energy auditor for property to improve energy efficiency and comfort.
Insulation was missing at some areas. Inspector recommends insulation be properly installed where missing to lower utility costs.
Wall Insulation
Insulation: Wall Insulation Not Observed, Undetermined
MOISTURE
Interior Moisture Signs
Interior: Moisture Stains Observed Dry
Dry moisture stains were observed. Stains are evidence of a prior undesirable moisture condition. Monitor area to verify cause of stain is not still present. Further evaluation may be needed if cause of stains persists. Properly correct cause of stain if needed. Properly repair affected areas as needed.
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Gable End Vent, Roof Deck Vent
Attic Intake Vents: Soffit Vents Where Installed
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof
Roof Style: Gable, Shed
Approximate Age of Roof Covering: Unknown
Roofing Material: Composition Three Tab Shingle, Roll Roofing
Consider Replacement All Roofing, Coordinate Roof Covering with Roof Framing
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some shingles observed worn.
- Some shingles observed damaged.
- Some shingles had temporary repairs.
- Some shingles did not lay flat. Correct shingles and/or roof decking as needed.
- Remove vegetation debris from roofing where needed.
- Vegetation on roof covering concealed view of areas.
- Vegetation debris on roof covering concealed view of areas.
Consider replacement of all roofing.
Weigh your options for repairing roof covering now and proper complete roof covering replacement now to determine which is the possible better long term solution for your situation. Considering that a properly replaced roofing system may last up to three decades it may make better sense to replace the roofing correctly now rather than to repair an aging roof system.
Roof Covering
Coordinate roof covering corrections needed now in conjunction with roof framing corrections needed now.
Gutters and Downspouts
Gutter and Downspout Materials: None
Gutters: Recommended Where Missing
The inspected property would benefit from adding gutters where missing to collect rain water and properly divert the water away from the foundation of the property.
SIDING and TRIM
Siding
Siding: Composition Siding
Eaves: Painted Wood
Trim: Wood
Siding: Flashing With Replacement
Older siding installation may not have modern flashing details for all areas where expected. Correct any flashings where needed now in conjunction with predictable siding replacement at older home needed now.
Siding: Corrections Needed
Exterior siding was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Physical Damage Observed
- Rot Observed
- Failing Paint Observed
- Temporary Repairs Observed
What you should do.
- Refurbish area before painting. A quality paint or stain job will include washing/cleaning all areas to be painted, repair/replacement of damaged siding and trim, seal all gaps, prime all unpainted areas and sufficient paint coverage to achieve desired color without bleed through.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance.
Consider Complete Replacement
Consider complete replacement of siding and trim now as a more cost effective long term solution rather than replacing portions of damaged siding and trim now then replacing additional portions of damaged siding as it continues to age.
Masonry Siding
Brick Veneer
What is Brick Veneer
Brick veneer siding serves as a non-structural outer layer of masonry. In contrast to solid brick constructions, which rely on multiple layers of brick for structural support, brick veneer systems depend on the underlying structure to support the masonry. The removal of the brick veneer would not compromise the building's structural integrity.
Brickwork: Requires Maintenance, Replace/Repair
Brickwork
Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance.
Siding: Brick Veneer Consider Complete Replacement
Consider complete replacement of brick veneer siding and trim now as a more cost effective long term solution rather than replacing portions of damaged siding and trim now then replacing additional portions of damaged siding as it continues to age. Brick veneer can be replaced with a less costly material such as vinyl siding, if desired. Other options are also available,
LOTS and GROUNDS
Driveway
None, add driveway if needed
Verify Meets Needs
Verify available parking for area served meets your needs, correct if needed.
Walkway
Porch
Stairs and Railings at Exterior
Diagram: Older Railing & Stairs
Railings and Stairs at older home as expected, did not meet current safety standards. Railings and stairs were ready for modernization for improved safety. Evaluate your risk exposure. Consider proper repair or replacement of stairs and railings where needed now for safety and function.
Stairs Repair/Replace
Evaluate your risk exposure. Consider proper repair or replacement of steps and railings where needed now for safety and function.
Vegetation
Vegetation Maintenance, Overhanging Branches
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Site
Site: Adjust Grade Slab
Adjust exterior grade for concrete slab floor construction. Some exterior grade work may improve storm water runoff away from foundation. Slope grade minimum ten feet away from and around structure so that water does not collect near foundation. Be sure that exterior soil grade and landscaping is below interior floor level at perimeter of foundation to help prevent unwanted moisture entry into interior areas.
Out Structures
Poor Condition, Locked
Attached Outbuilding observed in poor condition. Properly recondition outbuilding or remove outbuilding now for safety.
End of Report