How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Further Evaluation:Observations listed as further evaluation need a more extensive or technically exhaustive evaluation and warrant further investigation by a specialist. For areas where corrections may not be straight forward or where a proper plan should be developed to implement corrections, then further evaluation is recommended. To obtain further evaluation is to hire a specialist that is highly experienced in the repair or correction of a specific item or area. Some observations listed under other labels that also require further evaluation will appear under the other label only. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Routine Correction Needed:Observations listed as routine correction need repair or correction and are not unusual for the type and age property inspected. These routine items are typically not recurring and once properly corrected should not require repetitive correction. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- G-1 GARAGE:
Attached Garage Overhead Door at Interior
Overhead door was damaged. Overhead door operator was not tested.
Properly repair or replace overhead door for correct function. Test overhead door operator correcting for function and safety as needed.
- K-1 KITCHEN:
Location Kitchen
Sink
Leak observed under sink.
Properly repair leak and any affected areas.
- Sewage pump was found shut down. Sink faucet was immediately turned off when sewage pump was observed unplugged.
- B-1 BATHROOM:
Location Bathroom Main Level, Front, Right
Urinal
Urinal was leaking at piping above urinal basin when inspected. Video Provided
If damage has not yet occurred, future damage is likely. Properly repair as soon as possible along with correcting any affected areas, if present.
- P-1 PLUMBING:
Water Heater
Water heater temperature and pressure relief valve had a discharge extension piping that was a smaller diameter pipe than the relief valve.
Reduction of discharge line size will cause a restriction and reduce the discharge capacity of the valve. For safety this pipe should not be reduced.
Refer to discharge piping general guidelines. Proper correction is needed for correct function and safety.
- P-2 PLUMBING:
Water Heater
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Pressure temperature relief valve discharge piping was not installed properly.
- P-3 PLUMBING:
Water Heater
Water heater was found inoperative when inspected.
Properly put the water heater back in service correcting as needed for function and safety. Verify Hot/Cold orientation is correct at plumbing outlets. Properly correct orientation if needed.
- CS-1 CENTRAL SYSTEM:
Cooling System: System served left area
Corrections were needed to the cooling system.
The cooling unit failed to properly respond to the thermostat setting when it was inspected and the system was calling for cooling. Properly service cooling system correcting as needed for function and safety.
- CS-2 CENTRAL SYSTEM:
Heating System: System served left area
Corrections were needed for the heating system.
The furnace failed to properly respond to the thermostat setting when it was inspected and the system was calling for heat. Properly service heating system correcting as needed for function and safety.
- CS-5 CENTRAL SYSTEM:
Heating System: System served right area
Corrections were needed for the heating system.
The furnace failed to properly respond to the thermostat setting when it was inspected and the system was calling for heat. Properly service heating system correcting as needed for function and safety.
- CD-1 Central Ductwork:
Rain guard for exterior ductwork of all three package heating/cooling units was damaged or in need of repair or replacement.
Properly correct rain guard and any ductwork damage as needed.
- G2-1 Gas:
Gas Piping was ready for proper correction. Properly correct gas piping where needed.
- Sediment trap for gas piping to left furnace was not visible.
- E-1 ELECTRICAL:
Multiple Electrical Panels at one location, Exterior near Meter
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
- E-2 ELECTRICAL:
Multiple Breaker Panels at One Location Equipment Closet, not for storage
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
- E-3 ELECTRICAL:
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
- E-4 ELECTRICAL:
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Some electrical receptacles were observed damaged such as at rear exterior.
- Properly correct loose electrical receptacles where needed.
An electrical contractor should check all receptacles making functional and safe where needed.
- E-5 ELECTRICAL:
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were improperly installed.
- Some light fixtures were damaged.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
- R-1 ROOF:
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some roof areas appeared to pond water rather than shed water.
- Some deferred maintenance was observed.
- Debris was encountered beneath roof covering at lower right roof area.
- Some roof deck areas appeared soft.
Further Evaluations
- P-4 PLUMBING:
Questionable sewage pump system was observed beneath kitchen sink.
Obtain installation and warranty information for this equipment. The inspector recommends further evaluation by a competent contractor properly correcting if needed for function or safety. Such pumps should be accessible for periodic servicing and should have high water alarms to report failures. Inspection of this type system is outside the scope of the inspection performed and was not evaluated by the inspector.
- Sewage pump system was shut down being unplugged.
- A high water alarm was not visible.
- CS-3 CENTRAL SYSTEM:
Heating/Cooling System: System served left area
Further evaluation and proper correction of installation of central system is recommended.
Installation of central heating/cooling system should not interfere with repair or replacement of roof covering. As installed, central system will need to be uninstalled to properly repair or replace roof covering beneath central system.
- CS-4 CENTRAL SYSTEM:
Heating/Cooling System: System served center area
Further evaluation and proper correction of installation of central system is recommended.
Installation of central heating/cooling system should not interfere with repair or replacement of roof covering. As installed, central system will need to be uninstalled to properly repair or replace roof covering beneath central system.
- CS-6 CENTRAL SYSTEM:
Heating/Cooling System: System served right area
Further evaluation and proper correction of installation of central system is recommended.
Installation of central heating/cooling system should not interfere with repair or replacement of roof covering. As installed, central system will need to be uninstalled to properly repair or replace roof covering beneath central system.
- M-1 MOISTURE:
Wet moisture stains were observed at interior.
Stains are evidence of an undesirable moisture condition. Further evaluation is needed to determine exact source of unwanted moisture. Properly correct source of moisture. Take steps to prevent recurrence. Properly repair affected areas as needed.
- Multiple wet moisture stains and damage were observed at showroom baseboards.
- Wet moisture stains were observed at network room.
- Wet moisture stains were observed at storage closet.
- ST-1 SIDING and TRIM:
Exterior Insulation and Finish Systems (EIFS) siding was present at inspected property.
EIFS siding can be problematic if not properly installed and properly maintained.
Proper maintenance of EIFS siding will include destructive evaluation performed at regular intervals to ensure no undesirable moisture intrusion has occurred.
The most common issue with EIFS siding is when undesirable moisture intrusion occurs. The foam insulation panels can sometimes trap the moisture against the wooden wall framing which causes damage. This damage can go undetected for a period of time and may be costly to correct.
Penetrations through EIFS siding are undesirable, should be kept to a minimum and require special measures to guard against moisture intrusion at penetrations.
Obtain independent EIFS destructive evaluation properly correcting as needed. Full EIFS installation evaluation was not performed by inspector.
- ST-2 SIDING and TRIM:
Exterior Insulation and Finish System (EIFS) Siding
Installation irregularities were observed. Stucco siding areas should be further evaluated and properly repaired or replaced by a competent qualified contractor that specializes in the installation of this type siding material and is familiar with the installation standard.
- Representative Photos Provided
- Siding observed too close to Soil and Pavement
- Deferred Maintenance Observed
- Damage was visible
- Temporary repairs were visible
- LG-1 LOTS and GROUNDS:
Grading and Drainage
Drainage was improper at exterior of slab construction home, which means storm water can flow toward the slab structure.
Obtain further evaluation of exterior drainage. Consult a highly competent landscaping contractor, water proofing specialist, or State Licensed Professional Engineer that specializes in storm water management near structures. It is crucial that storm water near the home be properly managed to divert such water away from the home and foundation. Failure to do so properly can result in moisture transfer, water entry, and property damage.
If possible, slope grade a minimum of ten feet away from and around structure so that water does not collect near foundation. Additional measures such as a retaining wall or underground drainage system may be needed to compensate for improper drainage at property. Be sure that exterior soil grade and landscaping are below interior floor level at perimeter of foundation to help prevent unwanted moisture entry into interior areas at slab type construction.
- Exterior soil did not properly slope down and away from slab foundation.
The Full Report
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Exterior Hose Faucets
Janitorial Area
Water Heater
Equipment Observed
Plumbing Other
ELECTRICAL
Electrical Inspection
ELECTRICAL SERVICE
System Amps / Volts
MAIN PANEL
SUB PANEL
Branch Wiring
GFCI
Receptacle Outlets
Lighting/Ceiling Fans
Switches
Electrical Other
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Home Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Commercial
Site Built, Apparent additions built after original construction were observed.
Approximate Square Footage: 7436
Approximate Year of Original Construction: 1975
Approximate Low Temperature During Inspection: 65[F]
Approximate High Temperature During Inspection: 65[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Empty of Furnishings
Home was empty of furnishings when inspected.
________________________________________________________________________________________________________________________________________________________________
Ceilings
Interior Ceiling Materials: Drywall, Open, Suspended Ceiling
Interior Ceiling Condition:
- Some wear noted, recondition to your standard
________________________________________________________________________________________________________________________________________________________________
Walls
Interior Wall Materials: Concrete Block, Concrete Tile, Drywall, Painted Planks
Interior Wall Condition:
- Some wear noted, recondition to your standard
________________________________________________________________________________________________________________________________________________________________
Doors
Doors at Interior: Some door operation could be improved
Doors Correct as Needed
Doors at Interior
Properly correct interior doors to your standard and to meet your needs.
________________________________________________________________________________________________________________________________________________________________
Glazing/Glass
Single pane glass was present.
Windows
Metal framed windows were present.
Fixed in place, fulfilling their function.
GARAGE
GARAGE
GARAGE TYPE: Attached
Garage Floor Location: At Ground
Garage Floor: Floor Cracks Multiple, Saw Cut
________________________________________________________________________________________________________________________________________________________________
GARAGE OVERHEAD DOOR: Two Installed
Overhead Door Material: Metal
Overhead Door Insulation: Not Insulated
Overhead Door Operation: Operational
Overhead Door Condition:
Garage Overhead Door Operator Function: Operator Not Tested
Attached Garage Overhead Door Operator at Interior
Operator was not tested as the overhead door required correction before testing operator. Properly put this area back in service correcting as needed for function and safety.
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following builtin kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area: Main Level
Kitchen
Countertop: Granite
- Serviceable, fulfilling its function
Cabinets: Wood and wood composition
- Wear and damage observed, budget reconditioning
Floor Covering: Tile
- Some wear noted, recondition to your standard
Sink: Double Bowl Stainless Steel
Disposal: Not Present
Dishwasher: Not Present
Range: Not Present
Microwave: Not Present
Kitchen Exhaust: Not Present
Refrigerator: Not Present
Trash Compactor: Not Present
Location Kitchen
Sink
Leak observed under sink.
Properly repair leak and any affected areas.
- Sewage pump was found shut down. Sink faucet was immediately turned off when sewage pump was observed unplugged.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom 1
Half Bathroom
Location 1/2 Bathroom Main Level, Front, Right
Hand Washing: Vanity with basin
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Two, Pressure flush type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Some wear noted, recondition to your standard
Location Bathroom Main Level, Front, Right
Urinal
Urinal was leaking at piping above urinal basin when inspected. Video Provided
If damage has not yet occurred, future damage is likely. Properly repair as soon as possible along with correcting any affected areas, if present.
Bathroom 2
Half Bathroom
Location 1/2 Bathroom Main Level, Front, Left
Hand Washing: Vanity with basin
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Wear and damage observed, budget reconditioning
LAUNDRY
Laundry Connections
Laundry: Connections Not Observed
Laundry connections were not located for inspected property. Verify with owner should connections not be readily visible. Add laundry connections if needed.
PLUMBING
Supply Piping
Supply Piping: Copper
Water Flow at Supply Piping: Adequate
Adequate functional supply water flow was observed during inspection for water outlets operated.
Waste Piping
Apparent Vent Piping
Plastic - No Adverse
Material: Plastic
No adverse conditions were observed, maintain to meet your needs.
Exterior Hose Faucets
None
Janitorial Area
Water Heater
Water Heater
Water Heater
Size: 19.9 gallon 120V / Location: Equipment Closet
Year of Manufacture: 2003 / Fuel: Electric
Water Heater was not functional during inspection, verify Hot/Cold orientation at plumbing outlets, correct if needed.
Typical service life of a water heater is 8-12 years.
Water heater was very old, consider replacement as preventative maintenance.
Discharge Piping: General Guidelines
Water Heater - Temperature and Pressure Relief Valve - Discharge Piping General Guidelines
Consult a knowledgeable, competent, qualified plumbing contractor for specific requirements in your area.
Valve Manufacturer WARNING: To avoid water damage and/or scalding due to valve operation, a properly installed discharge line must be connected to valve outlet and run to a safe place of disposal.
- Discharge line shall serve a single relief device and shall not connect to piping serving any other relief device or equipment.
- The discharge line shall be installed in a manner that does not cause personal injury or structural damage.
- The discharge line shall be installed to a termination point that is readily observable by the building occupants.
- The discharge line shall be installed to allow complete drainage of both the valve and the discharge line.
- No reducing coupling or other restriction shall be installed in the discharge line.
- The discharge line must pitch downward from the valve and terminate not more than 6 inches (152 mm) above and not less than two times the discharge pipe diameter above the floor or flood level rim of the waste receptor.
- A proper air gap should be present above the floor or flood level rim of the waste receptor where the discharge pipe drains. The discharge piping should not drain into an indirect waste receptor such as a leak pan beneath a water heater.
- The discharge line must terminate through plain (unthreaded) pipe.
- Discharge line material must conform to local plumbing code or A.S.M.E. requirements. PVC piping is not rated for hot water and shall not be used.
- Excessive length - more than 30 feet (9.14m), use of more than four elbows or bends in discharge piping, or reduction of discharge line size will cause a restriction and reduce the discharge capacity of the valve.
- No shut-off valve shall be installed between the relief valve and tank, or in the discharge line.
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior type areas have contingency measures installed to mitigate expected leakage or rupture of water heater.
Such measures would collect and drain unwanted water to exterior to avoid damaging interior finishes. Consider upgrading water heater installation to help reduce unnecessary damage when the water heater leakage occurs.
Water Heater
Water heater temperature and pressure relief valve had a discharge extension piping that was a smaller diameter pipe than the relief valve.
Reduction of discharge line size will cause a restriction and reduce the discharge capacity of the valve. For safety this pipe should not be reduced.
Refer to discharge piping general guidelines. Proper correction is needed for correct function and safety.
Water Heater
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- Pressure temperature relief valve discharge piping was not installed properly.
Water Heater
Water heater was found inoperative when inspected.
Properly put the water heater back in service correcting as needed for function and safety. Verify Hot/Cold orientation is correct at plumbing outlets. Properly correct orientation if needed.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Missing
A plumbing thermal expansion tank was not observed near the water heater.
Monitor this area for leaks adding an expansion tank if needed.
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Unknown
Plumbing Supply Piping
A plumbing system pressure reducer was not located.
Verify location of installed pressure reducer or add as needed, if needed.
________________________________________________________________________________________________________________________________________________________________
Property Owner - Plumbing Supply Piping - MAIN WATER SHUT OFF VALVE - Apparent Location - Note Such Valves are Not Operated : Water Shut off Not Observed, unknown if present
Sewage Pump: System Questionable
Questionable sewage pump system was observed beneath kitchen sink.
Obtain installation and warranty information for this equipment. The inspector recommends further evaluation by a competent contractor properly correcting if needed for function or safety. Such pumps should be accessible for periodic servicing and should have high water alarms to report failures. Inspection of this type system is outside the scope of the inspection performed and was not evaluated by the inspector.
- Sewage pump system was shut down being unplugged.
- A high water alarm was not visible.
Plumbing Other
CENTRAL SYSTEM
Central Heat/Cool
Package System
Central Heating/Cooling
Package, Forced Air System Served: System served left area
Brand Furnace: Carrier / Location: Exterior Package Unit / Fuel: Natural Gas; Forced air system
Size: Unknown / Approximate Age: unknown: ID plate was not legible
Package gas furnaces with electric cooling typically have a service life of 15-20 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Size: Unknown / Fuel: Electric
Condensate disposal method: Add water seal trap at gravity condensate line for proper function
Consider properly replacing older central system as preventative maintenance.
________________________________________________________________________________________________________________________________________________________________
Cooling System: System served left area
Corrections were needed to the cooling system.
The cooling unit failed to properly respond to the thermostat setting when it was inspected and the system was calling for cooling. Properly service cooling system correcting as needed for function and safety.
Heating System: System served left area
Corrections were needed for the heating system.
The furnace failed to properly respond to the thermostat setting when it was inspected and the system was calling for heat. Properly service heating system correcting as needed for function and safety.
Heating/Cooling System: System served left area
Further evaluation and proper correction of installation of central system is recommended.
Installation of central heating/cooling system should not interfere with repair or replacement of roof covering. As installed, central system will need to be uninstalled to properly repair or replace roof covering beneath central system.
Central Heat/Cool
Package System
Central Heating/Cooling
Package, Forced Air System Served: System served center area
Brand Furnace: Carrier / Location: Exterior Package Unit / Fuel: Natural Gas; Forced air system
Size: Unknown / Approximate Age: unknown: ID plate was not legible
Package gas furnaces with electric cooling typically have a service life of 15-20 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Size: Unknown / Fuel: Electric
Condensate disposal method: Add water seal trap at gravity condensate line for proper function
Consider properly replacing older central system as preventative maintenance.
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Functional
Cooling System Functional
Inspector adjusted thermostat. Cooling system engaged and was found to be functional.
________________________________________________________________________________________________________________________________________________________________
Heating Function: Functional
Heating System Functional
Inspector adjusted thermostat. Heating system engaged and was found to be functional.
Heating/Cooling System: System served center area
Further evaluation and proper correction of installation of central system is recommended.
Installation of central heating/cooling system should not interfere with repair or replacement of roof covering. As installed, central system will need to be uninstalled to properly repair or replace roof covering beneath central system.
Central Heat/Cool
Package System
Central Heating/Cooling
Package, Forced Air System Served: System served right area
Brand Furnace: Carrier / Location: Exterior Package Unit / Fuel: Natural Gas; Forced air system
Size: Unknown / Approximate Age: unknown: ID plate was not legible
Package gas furnaces with electric cooling typically have a service life of 15-20 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Size: Unknown / Fuel: Electric
Condensate disposal method: Add water seal trap at gravity condensate line for proper function
Consider properly replacing older central system as preventative maintenance.
________________________________________________________________________________________________________________________________________________________________
Cooling Function: Functional
Cooling System Functional
Inspector adjusted thermostat. Cooling system engaged and was found to be functional.
________________________________________________________________________________________________________________________________________________________________
Heating System: System served right area
Corrections were needed for the heating system.
The furnace failed to properly respond to the thermostat setting when it was inspected and the system was calling for heat. Properly service heating system correcting as needed for function and safety.
Heating/Cooling System: System served right area
Further evaluation and proper correction of installation of central system is recommended.
Installation of central heating/cooling system should not interfere with repair or replacement of roof covering. As installed, central system will need to be uninstalled to properly repair or replace roof covering beneath central system.
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served, if present, shade, climate zone along with size, number and placement of windows have to be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the the installed central heating and cooling equipment. Properly maintain the ductwork system to meet your comfort needs and to allow system to operate properly.
Ductwork Issue: Rain Guard Package Unit Repair
Rain guard for exterior ductwork of all three package heating/cooling units was damaged or in need of repair or replacement.
Properly correct rain guard and any ductwork damage as needed.
Gas
Gas Fuel Piping
Natural gas piping observed at inspected property.
Properly maintain gas piping as needed for function and safety.
Installation Issue: Sediment Trap
Gas Piping was ready for proper correction. Properly correct gas piping where needed.
- Sediment trap for gas piping to left furnace was not visible.
Gas Appliance Flue
Flue
Furnace
Furnace System served left area
Flue Type: Metal Flue Self Contained
Appliance was inoperative when inspected.
Flue cont
Furnace
Furnace System served center area
Flue Type: Metal Flue Self Contained
Properly maintain flue for safety and function.
Flue cont
Furnace
Furnace System served right area
Flue Type: Metal Flue Self Contained
Appliance was inoperative when inspected.
Space Heating
Space Heater
Location: Garage
Fuel: Gas
Type: Blower heater
Not Operated: Unplugged
Unit was found shut down and out of service as the unit appeared off at the electrical disconnect. The unit was not observed in operation. Properly put the unit back in service correcting as needed for function and safety.
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment is most often one or more installed breaker panels and the branch wiring runs to all equipment, receptacles, lighting outlets and devices such as the light switches. The inspection report focuses on wiring operating between 100-250 Volts. While system Amperage and Voltage is recorded, it is not measured during inspection. Most low voltage wiring is excluded from the performed inspection. Low voltage items such as a heating and cooling thermostat are operated in order to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify each lamp or bulb is appropriate for the installed lighting fixture. The inspector recommends that you review the bulb or lamp installations for each fixture correcting as needed for safety and function. Common errors include 100 watt bulbs installed in fixtures rated for 60 watt max bulbs and interior rated bulbs installed at exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. Most, if not all, electrical corrections should be considered a safety concern.
ELECTRICAL SERVICE
System Amps / Volts
System Amperage: 600 Amp
System Voltage: 120/240 Volts, 120/240 Volts 3 phase with high leg
MAIN PANEL
Main Electrical Panel
Service Entrance Conductors: Aluminum, Stranded
Index: Index
Electrical panel directory was ready for correction. Properly index or label each electrical panel circuit as needed for clarity and safety.
Multiple Electrical Panels at one location, Exterior near Meter
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
SUB PANEL
Sub Electrical Panel
Index: Index
Access: Working Access
Observed electrical equipment panel should have unobstructed dedicated safe service access area of no less than 30" in width and 36" depth as measured out from the inspected electrical panel. This clear area is needed for safe access to this type of equipment. Consider relocating equipment or obstruction as needed to provide minimum safe working access to the electrical panel.
Enclosure: Plug/Plate Cover, Screws, Screws Pointed Tips
For safety, pointed end coarse thread screws should not be used to secure electrical panel cover.
Wiring: Remark White 240V Breaker, Neutral Multiple Lugged, Remark Wiring
Multiple Breaker Panels at One Location Equipment Closet, not for storage
Multiple corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. A competent electrical contractor should further evaluate this area. Make proper corrections as needed for safety and function now.
Branch Wiring
Material: Copper
Wiring Method: Metallic Sheathed Cable, Conduit, Non Metallic Sheathed Cable
Service Disconnect Missing
Electrical service disconnect was not observed near water heater at Equipment Closet. An electrical service disconnect within view of the permanently installed appliance is an important safety device for personnel servicing equipment. A competent electrical contractor should properly install an electrical service disconnect where missing for safety.
Branch Wiring
Multiple corrections were needed to improve the safety of the electrical branch wiring.
These corrections are usually non-recurring once properly completed. A competent electrical contractor should review the installed branch wiring making proper corrections where needed for both safety and function.
- Representative Photos Provided
GFCI
GFCI Commercial
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Other Than Dwelling Units.
(A) Pertains to Dwelling Units
(B) Other Than Dwelling Units
All 125-Volt through 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, and all receptacles supplied by three-phase branch circuits rated 150 volts
or less to ground, 100 amperes or less, installed in the following locations shall be provided with GFCI protection:
(1) Bathrooms
(2) Kitchens
(3) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(4) Buffet serving areas with permanent provisions for food serving, beverage serving, or cooking
(5) Rooftops
(6) Outdoors
(7) Sinks where receptacles or cord-and-plug-connected fixed or stationary appliances are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Indoor damp or wet locations
(9) Locker rooms with associated showering facilities
(10) Garages, accessory buildings, service bays, and similar areas other than vehicle exhibition halls and showrooms
(11) Crawl spaces at or below grade level
(12) Unfinished areas of basements
(13) Aquariums, bait wells, and similar open aquatic vessels or containers, such as tanks or bowls, where receptacles are installed within 1.8 m (6 ft.) from the top inside edge or rim or from the conductive support framing of the vessel or container
(14) Laundry areas
(15) Bathtubs and shower stalls where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Some
Some GFCI protection was present. Multiple areas would benefit from adding further GFCI protection. Consider modernizing electrical installation adding this shock protection, where missing, for all electrical areas where GFCI protection is known to improve safety. If installation of additional GFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
Receptacle Outlets
Electrical Receptacle Outlets
Multiple electrical receptacles were ready for proper correction.
- Some electrical receptacles were observed damaged such as at rear exterior.
- Properly correct loose electrical receptacles where needed.
An electrical contractor should check all receptacles making functional and safe where needed.
Lighting/Ceiling Fans
Correct Lighting Where Needed
Lighting/fans - Make lighting/fans functional and safe where needed.
- Some lighting was inoperative when inspected.
- Some lighting was not fully functional when inspected.
- Some light fixtures were improperly installed.
- Some light fixtures were damaged.
Check all lighting/fans making functional and safe where needed.
Representative Photos Provided
Switches
Switch Location Informational Note
Regarding Lighting Switch Locations:
While exact placement of lighting switches is considered a design issue, installing lighting switches at appropriate locations is useful to improve safety. Generally, a light switch would be located within arms length of the entry point of a room so that the lighting for the room you are entering may be switched on from an area near the doorway. Installing a switch at an inconvenient location, such as on the hinge side of a door, would not be desirable. Where the stairway between floor levels has six risers or more, a wall switch would be located at each floor level and at each landing level that includes an entryway to control the lighting for the stairway. Evaluate your need in regard to lighting switch locations. Consider updating switch locations for improved safety if desired.
STRUCTURE
Attic Access
Attic Access: None
Roof Framing
Framing: Trusses, Metal
Sheathing: Metal
Framing Access: Finished Restricted
Finished areas restricted view of structural components. Some areas were not observed by inspector.
Roof Framing: No Adverse
No adverse conditions where observed for visible portions of roof framing. Properly maintain this area to meet your needs.
Ceiling Framing
Ceiling Framing: Suspended ceiling with metal track framing was present for some areas.
Wall Framing
Concrete Block, Metal
Framing Access: Finished Restricted
Finished areas restricted view of structural components. Some areas were not observed by inspector. Concealed areas are not part of the inspection performed.
Underfloor Access
Slab: Finished Areas
Finished areas prevented view of structural components. Structural components were not observed by inspector at such areas.
Underfloor Description
Slab: On Grade
Underfloor Area
Access:
Slab construction no underfloor area present
Construction Type:
Concrete Slab on Grade
Foundation:
Poured in Place Concrete or Concrete Block
Columns or Piers:
Not Applicable
Floor Structure:
Concrete Slab Floor
Floor Insulation:
Not Applicable
INSULATION
Above Ceiling Insulation
Recommended Insulation
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Above Ceiling Insulation Not Observed, Undetermined
Wall Insulation
Insulation: Wall Insulation Not Observed, Undetermined
MOISTURE
Interior Moisture Signs
Wet moisture stains were observed at interior.
Stains are evidence of an undesirable moisture condition. Further evaluation is needed to determine exact source of unwanted moisture. Properly correct source of moisture. Take steps to prevent recurrence. Properly repair affected areas as needed.
- Multiple wet moisture stains and damage were observed at showroom baseboards.
- Wet moisture stains were observed at network room.
- Wet moisture stains were observed at storage closet.
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof
Roof Style: Low slope
Approximate Age of Roof Covering: Unknown
Roofing Material: Single Membrane - TPO
Roof covering was ready for corrections now.
A competent roofing contractor should check entire roof system and associated flashings. Properly repair or replace roof covering system as needed.
Roof Covering was Ready for Correction
- Representative Photos Provided
- Some roof areas appeared to pond water rather than shed water.
- Some deferred maintenance was observed.
- Debris was encountered beneath roof covering at lower right roof area.
- Some roof deck areas appeared soft.
Gutters and Downspouts
Gutter and Downspout Materials: Metal
Observation: Deferred Maintenance
Gutters: Cleaning Routine, Replace or Repair
Replace or repair gutters as needed for proper function.
SIDING and TRIM
Masonry Siding
Brick Veneer
Brickwork: Serviceable
Brickwork
The exterior readily visible areas of the brickwork were inspected and appeared to be in overall serviceable condition, fulfilling its function. All siding requires maintenance. Properly maintain siding condition correcting when needed.
Siding - Stucco
Exterior Insulation and Finish System (EIFS) Siding where installed
Exterior Insulation and Finish Systems (EIFS) siding was present at inspected property.
EIFS siding can be problematic if not properly installed and properly maintained.
Proper maintenance of EIFS siding will include destructive evaluation performed at regular intervals to ensure no undesirable moisture intrusion has occurred.
The most common issue with EIFS siding is when undesirable moisture intrusion occurs. The foam insulation panels can sometimes trap the moisture against the wooden wall framing which causes damage. This damage can go undetected for a period of time and may be costly to correct.
Penetrations through EIFS siding are undesirable, should be kept to a minimum and require special measures to guard against moisture intrusion at penetrations.
Obtain independent EIFS destructive evaluation properly correcting as needed. Full EIFS installation evaluation was not performed by inspector.
Exterior Insulation and Finish System (EIFS) Siding
Installation irregularities were observed. Stucco siding areas should be further evaluated and properly repaired or replaced by a competent qualified contractor that specializes in the installation of this type siding material and is familiar with the installation standard.
- Representative Photos Provided
- Siding observed too close to Soil and Pavement
- Deferred Maintenance Observed
- Damage was visible
- Temporary repairs were visible
LOTS and GROUNDS
Driveway
Asphalt, Concrete
Driveway: Recondition
Shared, Verify Meets Needs
Driveway appeared shared. Verify easement on file and party responsible for repairs.
Verify available parking for area served meets your needs, correct if needed.
Walkway
Stairs and Railings at Exterior
Vegetation
Vegetation Maintenance, Overgrown Shrubs
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Shrubs or other vegetation appeared too close to the exterior walls and can transfer unwanted moisture that may be detrimental to building components. Review vegetation correcting where needed. Consider having enough separation between plants and exterior walls so that you can walk as this allows air circulation and improves access for home maintenance. Areas concealed by overgrown vegetation were not observed by inspector.
Site
Slab: Crucial Slab Negative Drainage
Grading and Drainage
Drainage was improper at exterior of slab construction home, which means storm water can flow toward the slab structure.
Obtain further evaluation of exterior drainage. Consult a highly competent landscaping contractor, water proofing specialist, or State Licensed Professional Engineer that specializes in storm water management near structures. It is crucial that storm water near the home be properly managed to divert such water away from the home and foundation. Failure to do so properly can result in moisture transfer, water entry, and property damage.
If possible, slope grade a minimum of ten feet away from and around structure so that water does not collect near foundation. Additional measures such as a retaining wall or underground drainage system may be needed to compensate for improper drainage at property. Be sure that exterior soil grade and landscaping are below interior floor level at perimeter of foundation to help prevent unwanted moisture entry into interior areas at slab type construction.
- Exterior soil did not properly slope down and away from slab foundation.
Retaining Wall
End of Report