How to Read This Report
This digital report or a printed version of this report should only be viewed in full color where the photos are discernible and on a device where the report page width is no less than 8.5" wide. Please note, Right and Left of the building are determined as facing the front of building shown on the report cover. The client has the duty and obligation to read the entire report. Feel free to reach out to the inspector should you have any questions or concerns.
This report is designed to inform the client of obvious major structural deficiencies, inoperative conditions and the presence of noticeable, detrimental moisture issues for areas inspected. Additionally, the inspection report may advise regarding notable safety concerns and appropriate upgrades recommended by the inspector that you should consider and act on when appropriate. Please note, undesirable conditions pertaining to this inspection may be present and unreported for concealed areas and areas with limited or blocked access.
Photos
Photos included in this report are intended to help describe a reported item or area only. The photos, while representative, may not encompass the full scope of work required to correct the item or area listed. Repairs should be based on actual condition of property and not solely on the photos included in this report. Note, when viewing photos in the online report, clicking on a photo will zoom in and enlarge the photo. Clicking on a photo a second time will enlarge and zoom in on the photo one more time.
Repairs
Repairs or corrections needed at the inspected property should be completed by competent qualified professions familiar with the type of work being performed. Obtain competitive bids as needed. Obtain further evaluation when needed.
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy to access and understand. The best way to get the layers of information that are presented in this report is to read your report online in the HTML format, which will allow you to expand your learning about the inspected property. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information, if desired. Other text colors, if present, have no real meaning. Please read all written text.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin when viewing the report online.
Observation Labels
Narrative observation labels are defined here. Some of the following observation labels may not appear in all reports. Hazardous, Key Concerns and Further Evaluation observation label types, if used, will appear in the report and in the summary. All other observation labels, when used, appear only in the report and will not appear in the summary. All narrative observation label types are labeled, and numbered to help differentiate each reported narrative observation. When narrative observation labels are given a color, the specific color used has no meaning. Some observation labels are given a specific icon to group the observation types. The specific icon used also has no meaning.
Observation labels and colors used for reporting are:
- Key Concerns:Observations listed as key concerns need repair or correction and will typically include inoperative equipment, common and significant corrections needed for plumbing, electrical, heating/cooling, structure, interior and exterior areas including the roof covering. When used, this observation will appear in the report and in the summary.
- Further Evaluation:Observations listed as further evaluation need a more extensive or technically exhaustive evaluation and warrant further investigation by a specialist. For areas where corrections may not be straight forward or where a proper plan should be developed to implement corrections, then further evaluation is recommended. To obtain further evaluation is to hire a specialist that is highly experienced in the repair or correction of a specific item or area. Some observations listed under other labels that also require further evaluation will appear under the other label only. When used, this observation will appear in the report and in the summary.
- Periodic Maintenance Needed:Observations listed as periodic maintenance needed are items or areas that need repair or correction and are expected to have maintenance performed at some interval. Maintenance neglect may be from lack of maintenance knowledge or lack of adequate funding for periodic maintenance. Some irregular or substandard installations may need more frequent maintenance until properly replaced. Start dates and intervals for periodic maintenance are a matter of personal judgment. When used, this observation will appear only in the report.
- Safety Concerns:Observations listed as safety concerns are items or areas listed to help reduce the risk of personal injury and should be considered for repair, correction or upgrade. Safety standards and expectations change. Consideration should be given to evaluate and act upon your risk exposure to help reduce the risk of personal injury. Some observations listed under other labels that are also safety concerns will appear under the other label only, such as electrical repairs, which almost always pose some safety risk. Some safety concerns may also be considered improvements but will fall under the safety concerns label if deemed more appropriate. When used, this observation will appear only in the report.
- Routine Correction Needed:Observations listed as routine correction need repair or correction and are not unusual for the type and age property inspected. These routine items are typically not recurring and once properly corrected should not require repetitive correction. When used, this observation will appear only in the report.
- Monitor:Observations listed as monitor are typically items or areas that need subsequent observations and should be monitored over time to obtain historical data. These items may or may not require correction in the future based upon their performance over time. If you are unable to do the monitoring, the inspector recommends you appropriately schedule monitoring by a qualified competent contractor. Some observations listed under other labels that also may require monitoring will appear under the other label only. When used, this observation will appear only in the report.
- Improve:Observations listed as improve are items or areas that were ready for repair or correction that involve improvement or upgrade. This label is used for predictable expected opportunities to better the property condition or installation deficiencies that may or may not affect equipment function. Some observations listed under other labels that also may be considered improvements will appear under the other label only. When used, this observation will appear only in the report.
- Note:Notes are general remarks or comments elaborating on descriptions of systems, limitations, restrictions, or other similar conditions present during the inspection. Notes do not appear in the summary.
- Inspector Informational Note:Inspector informational note regarding inspection process.
- Description:Descriptive information for various aspects of the property, equipment, items, or areas noted during the inspection. Descriptions do not appear in the summary.
- Deck Description:Description of observed deck conditions and issues.
Summary Page
For convenience, the report contains a summary. The inspector uses the Summary to list non Periodic Maintenance issues that, in his opinion, he would expect to be completed before marketing the home for sale. Be advised, the summary contains only text from the observations listed as Key Concerns, Further Evaluation Needed, Hazardous and when applicable, New Construction Builder Punch List Items. The summary does not show any photos or photo captions that may be listed with an observation. The summary provides the least information for the observations listed.
The report body contains the most information and includes full descriptions, digital photographs, captions, and when applicable, diagrams, videos and hot links to additional information. Refer to the report body when making actual corrections, upgrade or repairs. Please understand that you have a duty and obligation to read the full report.
Summary
Key Concerns
- K-1 KITCHEN:
Exhaust at Microwave
Deep cabinet above microwave restricted exhaust opening at top of and towards front of microwave. Proper correction is recommended.
Multiple corrections are possible to improve condition or to prevent damage to cabinet or possibly the exhaust fan.
Some options are:
- It is possible to build a proper structural spacer that is at least 4" deep that would be attached between the wall behind the microwave and the microwave itself such that the microwave exhaust would properly extend beyond the cabinet front.
- Consider discontinuing use of exhaust fan altogether. If the exhaust fan comes on automatically with microwave use then consider discontinuing use of microwave and exhaust altogether.
- Consider replacing microwave with one that exhausts out the front rather than the top.
- Consider replacing or modifying the cabinet above the microwave to prevent the cabinet from obstructing the exhaust.
Refer to installation instructions. Properly correct as desired to meet your needs making system fully functional and safe.
- B-1 BATHROOM:
Location Full Bathroom Main Level, En Suite, attached to a bedroom
Area: Bathing Faucet
Faucet was loose and not operated.
Properly secure faucet as needed. Properly correct any affected areas if present.
- B-2 BATHROOM:
Location Full Bathroom Main Level, En Suite, attached to a bedroom
Area: Tub
Tub was not secured in place. Faucet was not operated.
Properly secure tub as needed to help prevent leaks.
- B-3 BATHROOM:
Location Full Bathroom Main Level, En Suite, attached to a bedroom
Left Sink
Faucet did not operate properly when inspected. Video Provided.
Properly correct as needed for function and safety.
- P-1 PLUMBING:
Water Heater
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
- CS-1 CENTRAL SYSTEM:
Heat Pump System:
Back up heat failed to properly respond when thermostat was set to manually engage the emergency heat on heat pump.
The back up heat should be functional when turned on manually for testing regardless of outdoor temperature. Proper servicing of system is recommended. Due to the condition of the heating system, it is recommended that a qualified competent heating contractor service this system properly correcting as needed for function and safety.
- E-1 ELECTRICAL:
Main Breaker Panel Garage
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
- E-2 ELECTRICAL:
Sub Breaker Panel Basement
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
- E-3 ELECTRICAL:
Lighting
Service lighting was missing for Water Heater at Basement.
- Existing lighting at area did not properly illuminate service area for appliance and additional lighting should be installed.
Equipment requiring periodic servicing should have permanent lighting installed near such equipment that illuminates the control side of the equipment. This service lighting should be controlled by a switch that is installed at the entry point to the area where the equipment is installed. Consider properly adding additional lighting where needed near such equipment for improved safety and to facilitate servicing equipment when needed.
- D-1 DECK:
Deck areas were observed ready for corrections now and before use to improve the structure of the deck and to improve the safety aspects for the fall prevention measures installed at deck areas. Refer to the full report for additional information and photos regarding obvious corrections recommended now for any deck areas. A competent deck contractor should check all deck areas. Make deck areas functional, safe and structurally sound where needed.
- Representative Photos Provided
Further Evaluations
- CS-2 CENTRAL SYSTEM:
Inspection performed does not determine system adequacy.
Capacity of central heat/cool unit appeared undersized for reported (square footage) area served. A competent heat/cool contractor should further evaluate system and perform load/distribution analysis properly correcting system as needed.
3 ton heat pump appeared undersized to serve reported 3036 sqft home.
- Single system was attempting to serve three separate floors.
- Air returns were not present to serve each floor.
- Left basement area was not served by ductwork.
- Zone control ductwork was present but there was no thermostat at basement.
- ST-1 SIDING and TRIM:
Concrete tile siding observed irregular and further evaluation is recommended.
Installation irregularities were observed. Adhered concrete tile siding areas should be further evaluated and properly repaired or replaced by a competent qualified contractor that specializes in the installation of this type siding material and is familiar the installation standard. Properly correct any affected areas damaged by improper installation, if present.
Representative Photos Provided
- Siding observed too close to Soil and Pavement
- Some concrete tile observed cracked
- Some concrete tile observed loose
- Irregular transition was observed at dissimilar materials
The Full Report
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Doors
Glazing/Glass
Windows
Stairs/Railings Interior
Stairs/Railings Interior
PLUMBING
Supply Piping
Waste Piping
Apparent Vent Piping
Other Sink Area
Exterior Hose Faucets
Water Heater
Equipment Observed
ELECTRICAL
Electrical Inspection
ELECTRICAL SERVICE
MAIN PANEL
SUB PANEL
Branch Wiring
AFCI
GFCI
Receptacle Outlets
Lighting/Ceiling Fans
Smoke Alarms
STRUCTURE
Attic Access
Roof Framing
Ceiling Framing
Wall Framing
Underfloor Access
Underfloor Description
Floor System
About the Inspection Process
Home Inspection: Scope and Purpose of a Home Inspection
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most home buyers.
Inspection: Home Inspection Agreement
Inspection Agreement
Major Structural and Electromechanical Inspection
HomePro Inspection, Inc. agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property in accordance with the Standards as set forth by the American Society of Home Inspectors (ASHI) and the State of Tennessee. The inspection and written report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT; the report is nontransferable.
The written report will include the following only:
- general exterior, including roof, siding, windows, chimney, drainage and grading
- structural condition of foundation & frame
- electrical, plumbing, hot water heater, heating and air conditioning
- general interior, including ceilings, walls, floors, windows, insulation and ventilation
Maintenance and other items may be discussed but they are not a part of the inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind and is only based on the inspector’s opinions.
It is understood and agreed that the inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing at the time of the inspection only. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items and systems will not be moved or dismantled. When the inspection is for only one or a limited number of systems or components, the inspection is limited to only those systems or components that were inspected. Detached structures are not included. HomePro Inspection, Inc. will be under no obligation under any circumstances for any further follow-up inspection.
ENVIRONMENTAL HAZARDS including Asbestos, Mold, Fungus, Lead, Radon, Cockroaches, Rodents, Pesticides, Treated Lumber, Mercury, Carbon Monoxide, Urea Formaldehyde, Toxic Wastes, Polluted Water, Contaminants and all Pollutants and Hazardous Materials or other similar environmental hazards are not part of this Home Inspection. In addition, no inspection for household insects or unwanted animals will be done.
This report does not address Subterranean Systems or system components for Sewage Disposal, Water Supply, or Fuel Storage or Delivery. Auxiliary systems such as Alarm, Security, Intercom, other low voltage wiring, Generator, Private Water, Sprinkler, Elevator, Central Vacuum, Refrigerators, Laundry Equipment, Solar, Swimming Pools, Hot Tubs, Saunas, Space Heaters, Window Air Conditioners and or any system not considered a part of the major building systems are not a part of the inspection process.
The parties agree that the HomePro Inspection, Inc., and its employees and agents, assume no liability or responsibility for the cost of repairing or replacing any unreported defects or deficiencies, either current or arising in the future, or for any property damage, consequential damage or bodily injury of any nature. THE INSPECTION AND REPORT ARE NOT INTENDED AS A GUARANTEE OR WARRANTY, EXPRESSED OR IMPLIED INCLUDING REGARDING THE ADEQUACY, OR PERFORMANCE OF ANY INSPECTED STRUCTURE, ITEM OR SYSTEM. THE HOMEPRO INSPECTION, INC. IS NOT AN INSURER OF ANY INSPECTED CONDITIONS.
It is understood and agreed that should HomePro Inspection, Inc. and/or its agents or employees be found liable for any loss or damages resulting from a failure to perform any of its obligations, including but not limited to negligence, breach of contract or otherwise, then the liability of HomePro Inspection, Inc. and/or its agents or employees, shall be limited to a sum equal to the amount of the fee paid by the CLIENT for the Inspection and Report.
The parties agree that the faxed or digital copy of the agreement is to be relied upon in lieu of the original.
Acceptance and understanding of this agreement are hereby acknowledged:
Digital Signature: Roger Williamson
License #226 TN
General Comments
Building Characteristics, Conditions and Limitations
Type of Building : Single Family Home
Site Built, Possible unfinished basement area converted to finished living space.
Approximate Square Footage: 3036
Approximate Year of Original Construction: 2020
Weather during the inspection: Cloudy
Ground/Soil surface conditions: Dry
Approximate Low Temperature During Inspection: 70[F]
Approximate High Temperature During Inspection: 75[F]
INTERIOR
Interior Access / Ceilings / Walls / Floor Coverings
Interior Access: Furniture, Property
Access and visibility was limited at interior areas as furnishings and personal property were present.
________________________________________________________________________________________________________________________________________________________________
Ceilings
Interior Ceiling Materials: Drywall, Suspended Ceiling
Interior Ceiling Condition:
- Some settlement type cracking observed.
- Some wear noted, recondition to your standard
Low Ceiling
________________________________________________________________________________________________________________________________________________________________
Walls
Interior Wall Materials: Drywall
Interior Wall Condition:
- Some wear noted, recondition to your standard
________________________________________________________________________________________________________________________________________________________________
Flooring
Interior Flooring Materials: Carpet, Wood, Tile, Concrete
Interior Flooring Condition:
- Some wear noted, recondition to your standard
Doors
Doors Correct as Needed
Doors at Interior
Properly correct interior doors to your standard and to meet your needs.
________________________________________________________________________________________________________________________________________________________________
Doors to Exterior: Weatherization
Weather stripping could be improved. Properly correct or replace weather stripping where needed.
Glazing/Glass
Insulated glass was present.
Windows
Vinyl framed windows were present.
Serviceable
A representative number of accessible windows were operated and were found generally serviceable within the parameters of their given service life.
Stairs/Railings Interior
Stairs Serviceable, fulfilling its function: For stairs to second floor, For stairs to basement
________________________________________________________________________________________________________________________________________________________________
Railing Serviceable, fulfilling its function: Railing for stairs to second floor, Railing for stairs to basement
________________________________________________________________________________________________________________________________________________________________
Stairs/Railings Interior
Diagram: Correction Needed Railing
Railings were ready for modernization for improved safety. Some municipalities are more laxed in their enforcement of safety requirements than others. Evaluate your risk exposure. Consider proper repair or replacement of railings where needed now for safety and function.
Railings were ready for upgrade: Railing for stairs at garage
Handrail: ≥4 3/8", Missing
Openings at handrails, such as at balusters, were ready for correction or upgrade as they did not reject a 4 3/8" sphere for all openings.
Railings: Risers ≥4"
Openings at stair steps such as at risers did not reject a 4" sphere for all openings. Evaluate your risk exposure properly correcting as needed for improved safety and function.
GARAGE
GARAGE
GARAGE TYPE: Attached
Garage Floor Location: At Ground, Above Ground
Garage Restrictions: Excess Stored Items
Excess stored items were present at garage when it was inspected limiting view and access to most areas of garage. Obtain reasonable access and reinspect area prior to settlement. Make corrections if needed.
Garage Separation from Living Space: Drywall Present Ceiling/Wall
Drywall was observed installed on ceiling framing and the wall framing that separated the garage and living space.
Should a fire occur at an attached garage area, properly installed drywall on framing, where needed, can offer some assistance to slow the spread of fire and smoke from the garage area to living areas. Properly maintain this area as needed.
________________________________________________________________________________________________________________________________________________________________
GARAGE OVERHEAD DOOR: One Installed
Overhead Door Material: Metal
Overhead Door Insulation: Partially Insulated
Overhead Door Operation: Tested Using Operator
________________________________________________________________________________________________________________________________________________________________
GARAGE OVERHEAD DOOR OPERATOR: Testing Garage Overhead Door Operators
Testing Electric Operators for Garage Overhead Doors
Garage overhead door operators require periodic maintenance to maintain safe operation. Electric overhead door operators are checked for function and safety when inspected.
Modern garage overhead door operators have two safety reversal means; contact reversal and non-contact reversal.
Contact reversal is when the garage overhead door hits an obstruction that should cause the operator to reverse for safety.
Non-contact reversal is when the electronic eyes detect an obstruction, without the garage overhead door hitting an object, that should cause the operator to reverse for safety.
The contact reversal of the garage door operator is tested using a 1.5 inch obstruction on the floor at the center point of the overhead door. If the contact reversal requires correction, this is typically accomplished by a simple adjustment on the operator but other corrections could also be necessary. See overhead door operator owners manual for additional details.
If the electronic eyes area installed properly, the non-contact reversal is tested by obstructing the path between the electronic eyes while the operator is closing the garage overhead door. The installation height of the electronic eyes varies slightly by manufacture. Most manufacturers typically advise installing the electronic eyes no more than six inches above the floor at the overhead door track. If the electronic eyes are out of alignment, the operator will not close the garage overhead door without pushing and holding the wired, wall mounted, push-button until the garage overhead door is fully closed. If the electronic eyes require adjustment, this is typically accomplished by remounting or correcting the aim of the electronic eyes but other corrections could also be needed. See overhead door operator owners manual for additional details.
Overhead Door Operator: One Installed
Garage Overhead Door Operator Function: Operator Functional
KITCHEN
Inspection Process
Kitchen Inspection Process
Kitchen Inspection Process
Kitchen inspection was of the readily accessible and visible portions of the kitchen. The kitchen inspection includes the countertops and a representative number of cabinets. Kitchen faucets, when functional, are run for longer than one minute checking for observable leaks and hot/cold orientation.
The following builtin kitchen appliances, where installed, were inspected and on/off operated testing the main function of each appliance using the normal operating controls:
- Cooktop / Oven / Range (cook surface with integral oven)
- Microwave
- Garbage Disposal
- Trash Compactor
Installed dishwashers are run through a normal cycle. Obvious functional issues and leaks observed around the dishwasher are reported, if present.
Ventilation equipment, such as range hoods, are inspected, on/off operated and are reported as ductless, ducted or recirculating. It is beyond the scope of this inspection to determine the effectiveness of the kitchen exhaust fan, such as to verify air flow quantity or discharge location.
Appliance inspection does not cover clocks, timers, self cleaning function, calibration, automatic functions or optional equipment on appliances.
Refrigerators are considered personal property and are not evaluated. Refrigerator presence or absence is noted. Faucets for refrigerator ice makers are not tested whether the refrigerator is present or not as there is no basin to catch the water from the ice maker faucet.
Equipment that appears to be shut down, inoperable or intentionally taken out of service is noted but will not be operated by the inspector. Shut down equipment may be unplugged, breaker off, water off, gas off or otherwise taken out of service.
Installation conditions and functional issues for this area requiring correction should be performed by a competent qualified contractor.
Kitchen
Kitchen Area: Main Level
Kitchen
Countertop: Granite
- Serviceable, fulfilling its function
Cabinets: Wood
- Wear noted, properly recondition to meet your needs
Floor Covering: Wood
- Some wear noted, recondition to your standard
Sink: Double Bowl Stainless Steel
- No leaks were viewed at faucet or visible supply lines or waste drain just beneath the sink.
Disposal: Present and appeared functional
Dishwasher: Present and ran through a normal cycle without incident
Range: Range (Electric Top/Oven)
Present and On/Off Tested functional
Microwave: Present and On/Off Tested functional
Kitchen Exhaust: Ductless in microwave appeared functional.
Refrigerator: Present but not evaluated
Trash Compactor: Not Present
Exhaust at Microwave
Deep cabinet above microwave restricted exhaust opening at top of and towards front of microwave. Proper correction is recommended.
Multiple corrections are possible to improve condition or to prevent damage to cabinet or possibly the exhaust fan.
Some options are:
- It is possible to build a proper structural spacer that is at least 4" deep that would be attached between the wall behind the microwave and the microwave itself such that the microwave exhaust would properly extend beyond the cabinet front.
- Consider discontinuing use of exhaust fan altogether. If the exhaust fan comes on automatically with microwave use then consider discontinuing use of microwave and exhaust altogether.
- Consider replacing microwave with one that exhausts out the front rather than the top.
- Consider replacing or modifying the cabinet above the microwave to prevent the cabinet from obstructing the exhaust.
Refer to installation instructions. Properly correct as desired to meet your needs making system fully functional and safe.
BATHROOM
Inspection Process
Testing Limitations
Bathroom Inspection Process
The following opinion was based on an inspection of the readily accessible and visible portions of bathroom areas.
Hand washing faucets, when functional, are run for approximately one minute checking for observable leaks at the faucet and beneath the sink as well as checking Hot/Cold orientation.
Bathing area faucets, when functional, are run for approximately five minutes checking for observable leaks and Hot/Cold orientation.
Toilets, when functional, are flushed twice. Inspector checks for leaks around toilet, checks that toilet fills and shuts off, and checks to see if toilet appears securely mounted.
Effectiveness and discharge locations for mechanical bathroom exhaust vents are not confirmed during inspection.
Installation conditions and functional issues for this area requiring correction should be performed by a competent, qualified contractor.
Bathroom 1
Full Bathroom
Location Full Bathroom Upstairs
Bathing Area: Combination tub and shower
- No leaks were observed around faucet and the water containment area appeared serviceable.
Hand Washing: Two basins in vanity
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
- Window present to ventilate bathroom.
Floor Covering: Tile
- Some wear noted, recondition to your standard
Bathroom 2
Full Bathroom
Location Full Bathroom Main Level, EnSuite, attached to a bedroom
Bathing Area: Soaking tub and separate shower
- No leaks were observed around shower faucet and the water containment area appeared serviceable.
- Properly maintain tile work to meet your needs.
Hand Washing: Two basins in vanity
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
- Excess personal property beneath sink greatly restricted view of area.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Tile
- Some wear noted, recondition to your standard
Location Full Bathroom Main Level, En Suite, attached to a bedroom
Area: Bathing Faucet
Faucet was loose and not operated.
Properly secure faucet as needed. Properly correct any affected areas if present.
Location Full Bathroom Main Level, En Suite, attached to a bedroom
Area: Tub
Tub was not secured in place. Faucet was not operated.
Properly secure tub as needed to help prevent leaks.
Location Full Bathroom Main Level, En Suite, attached to a bedroom
Left Sink
Faucet did not operate properly when inspected. Video Provided.
Properly correct as needed for function and safety.
Bathroom 3
Half Bathroom
Location 1/2 Bathroom Main Level
Hand Washing: Pedestal type
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- Fan on/off tested. The sound heard appeared to be appropriate for the fan.
Floor Covering: Engineered Flooring
- Some wear noted, recondition to your standard
Bathroom 4
Full Bathroom
Location Full Bathroom Basement
Bathing Area: Combination tub and shower
- No leaks were observed around faucet and the water containment area appeared serviceable.
Hand Washing: Vanity with basin
- No leaks were observed around faucet visible supply lines or waste drain just beneath the sink.
Toilet: Water tank type
- No Leaks were observed around toilet and it appeared secured in place.
Ventilation:
- None. Bath ventilation recommended. Consider adding.
Floor Covering: Engineered Flooring
- Serviceable, fulfilling its function
LAUNDRY
Laundry Connections
Laundry: Appliances Present
Laundry appliances were present during inspection.
Laundry appliances restricted view of laundry connections. Laundry appliances typically do not convey with property. Laundry appliances are not evaluated during inspection. Laundry faucets are not operated when appliances are connected to faucets. Verify your clothes dryer exhaust is functional, safe and properly installed to meet the requirements of clothes dryer manufacturer in use.
PLUMBING
Supply Piping
Supply Piping: PEX
Some Copper, Some CPVC
Water Flow at Supply Piping: Adequate
Adequate functional supply water flow was observed during inspection for water outlets operated.
Waste Piping
Waste Piping: Functional Flow Plastic
Material: Plastic
Functional waste water flow observed during inspection for water outlets operated.
Apparent Vent Piping
Plastic - No Adverse
Material: Plastic
No adverse conditions were observed, maintain to meet your needs.
Other Sink Area
Exterior Hose Faucets
Two
Performance: Functional Multiple
Exterior Hose Faucets
Exterior hose faucets were turned on and off briefly and appeared to function normally.
Water Heater
Water Heater
Access: Area Not For Storage
Leak Mitigation: Installed at Interior
Water Heater
It is recommended that water heaters installed at or adjacent to interior type areas have contingency measures installed to mitigate expected leakage or rupture of water heater.
Such measures would collect and drain unwanted water to exterior to avoid damaging interior finishes. Consider upgrading water heater installation to help reduce unnecessary damage when the water heater leakage occurs.
Water Heater
Questionable Installation
Water heater did not appear to meet manufacturer installation standards for proper installation when inspected.
Refer to installation instructions and have a competent contractor correct as needed for function and safety.
- Water heater proper leak provisions were not installed.
Equipment Observed
Plumbing Equipment Observed Present But Not Tested or Evaluated: ________________________________________________________________________________________________________________________________________________________________
Thermal Expansion: About Thermal Expansion
Regarding Plumbing System Thermal Expansion:
Thermal expansion occurs when a tanked water heater operates without any plumbing valves open for a period of time. If the property water meter has a check or backflow preventer valve installed it will prevent the expanding contained water from flowing backwards through the water meter. This expansion causes the water heater pressure relief valve to open briefly releasing a small amount of water if an expansion control device is not present or not working properly. If the pressure relief valve on the water heater opens and does not seal closed properly then active leaks and subsequent damage may occur.
Tank Present
________________________________________________________________________________________________________________________________________________________________
Pressure Reducer: About Pressure Reducing Valves
Regarding Plumbing System Pressure Reducing Valves:
The pressure reducer or pressure regulator in a plumbing system is designed to reduce the water pressure to a reasonable level in an effort to help prevent damage to the plumbing system. For most areas if the utility water pressure is greater than 80 PSI (pounds per square inch) a pressure reducer is needed. For some areas with extremely high utility pressure multiple pressure reducers may be needed installed in series. Pressure reducers are typically factory set for 50 PSI and property water pressure is expected to be between 30 PSI and 80 PSI. Inspector notes presence of pressure reducer when observed. Pressure readings for plumbing system are not part of the inspection performed.
Pressure Reducer Location: Basement
________________________________________________________________________________________________________________________________________________________________
CENTRAL SYSTEM
Central Heat/Cool
Split System - Heat Pump
Central Heating/Cooling
Split, Forced Air Heat Pump System served:
Brand Furnace: Goodman / Location: Basement / Fuel: Electric Heat Pump
Size: 3 ton / Year of Manufacture: 2019
Heat pumps typically have a service life of 12-18 years when properly maintained
Filter Type: Disposable / Thermostat Type: Digital - Thermostat was located within area served.
Cooling Brand: Goodman / Location: Exterior / Fuel: Electric
Year of Manufacture: 2019
Heat pumps typically have a service life of 12-18 years when properly maintained
Condensate disposal method: Condensate pump was present, service annually
Heat Pump: Backup Heat Failed
Heat Pump System:
Back up heat failed to properly respond when thermostat was set to manually engage the emergency heat on heat pump.
The back up heat should be functional when turned on manually for testing regardless of outdoor temperature. Proper servicing of system is recommended. Due to the condition of the heating system, it is recommended that a qualified competent heating contractor service this system properly correcting as needed for function and safety.
Inspection performed does not determine system adequacy.
Capacity of central heat/cool unit appeared undersized for reported (square footage) area served. A competent heat/cool contractor should further evaluate system and perform load/distribution analysis properly correcting system as needed.
3 ton heat pump appeared undersized to serve reported 3036 sqft home.
- Single system was attempting to serve three separate floors.
- Air returns were not present to serve each floor.
- Left basement area was not served by ductwork.
- Zone control ductwork was present but there was no thermostat at basement.
Central Ductwork
Distribution Ductwork
Ductwork Information: About your central heating and cooling ductwork
Regarding calculating the load of a central system:
Several factors are considered when performing a load evaluation for central heating and cooling systems to determine the appropriate size system for the area served. Factors such as installed ductwork, insulation, ceiling height, basement area served, if present, shade, climate zone along with size, number and placement of windows have to be taken into account before sizing a system. The inspector does not calculate the load of a central heating and cooling system during the performed inspection. The inspector also does not confirm that the installed ductwork is appropriately sized to serve the the installed central heating and cooling equipment. Properly maintain the ductwork system to meet your comfort needs and to allow system to operate properly.
Gas
Gas Fuel Piping
Representative Photo
Representative Photo
Propane gas piping observed at inspected property.
Properly maintain gas piping as needed for function and safety.
Space Heating
Fireplace
Fireplace Use Nonessential
Regarding Fireplace Use:
Fireplace use was nonessential. The installed fireplace was not the sole heating system for the inspected property and does not have to function if you do not desire to use the fireplace area. Typically, deficient fireplaces are not listed in the summary of the report. Properly repair fireplace area for function and safety if use is desired.
Type: Prefabricated or Manufactured Fireplace
Unvented/Ventless/Vent Free/Room Vented
Regarding Room Vented Fireplaces also known as Unvented, Ventless or Vent Free Fireplaces or Firebox Enclosures
Room vented firebox enclosures do not have a flue that exhausts to an exterior area. Gas log set heaters installed inside this type of fireplace burn using the oxygen in the room. Gas log set heaters installed in room vented fireplaces should be equipped with special devices that automatically shut off the gas to the heater should nearby oxygen reach unhealthy levels. Additionally, manufacturers often recommend homeowners leave a window open an inch or two while operating a gas log set heater to introduce fresh air into the room. For improved safety, the inspector recommends not sleeping in an area when a gas log set heater is in use and not using a gas log set heater as the primary heat source for the area served. Properly maintain any fireplace as needed for proper function and safety.
Gas Log Set Heater: Present
Gas Log Set Heater Function: Failed to Light
Gas Log Set Heater
Failed to Light
The gas log heater was inspected and found inoperative when using the normal operating controls. The inspector attempted to light the gas appliance and it failed to respond after a dozen attempts. Often this is remedied simply by allowing the gas to advance forward for several minutes or by restoring the fuel supply but other conditions may also exist. Properly put the gas log heater back in service correcting as needed for function and safety.
ELECTRICAL
Electrical Inspection
Electrical System Inspection
What is an electrical system?
The electrical system consists of an electrical service, distribution equipment and branch wiring. The electric metering equipment is usually at the electrical service. Distribution equipment is most often one or more installed breaker panels and the branch wiring runs to all equipment, receptacles, lighting outlets and devices such as the light switches. The inspection report focuses on wiring operating between 100-250 Volts. While system Amperage and Voltage is recorded, it is not measured during inspection. Most low voltage wiring is excluded from the performed inspection. Low voltage items such as a heating and cooling thermostat are operated in order to determine the function of such equipment.
There are now a wide variety of lighting bulbs or lamps that will fit into lighting fixtures. Some choices may not be appropriate for some lighting fixtures. It is beyond the scope of this inspection to verify each lamp or bulb is appropriate for the installed lighting fixture. The inspector recommends that you review the bulb or lamp installations for each fixture correcting as needed for safety and function. Common errors include 100 watt bulbs installed in fixtures rated for 60 watt max bulbs and interior rated bulbs installed at exterior or damp locations. Other types of errors also exist.
The following opinion was based on an inspection of the readily accessible and visible portions of the electrical system. The Inspector is responsible for checking a representative number of installed lighting fixtures, switches, and receptacles. Electrical installation conditions and functional issues requiring correction should be performed by a competent licensed electrical contractor. Most, if not all, electrical corrections should be considered a safety concern.
ELECTRICAL SERVICE
MAIN PANEL
Main Electrical Panel
Service Entrance Conductors: Aluminum, Stranded
Index: Differentiate, Vague
Electrical circuit directory appeared vague. Proper correction is recommended.
Access: Area Not For Storage
Location Issue: Breaker Over 79" Above Floor
Main Breaker Panel Garage
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
SUB PANEL
Sub Electrical Panel
Index: Index, Vague
Electrical panel directory was ready for correction. Properly index or label each electrical panel circuit as needed for clarity and safety.
Access: Area Not For Storage
Enclosure: Protect Wiring at KO
Enclosure: Panel Bond Missing
Panel bond did not appear present. Properly install panel bond where missing to prevent enclosure from becoming energized should a specific malfunction occur.
Sub Breaker Panel Basement
Corrections were needed at electrical distribution panel.
Refer to the full report for additional information and photos regarding obvious corrections recommended for this electrical panel. Make proper corrections as needed for safety and function now.
Branch Wiring
Material: Copper
Wiring Method: Non Metallic Sheathed Cable
AFCI
AFCI Residential
What is Arc Fault Circuit Interrupter (AFCI) Protection?
AFCI protection is designed to break the electrical circuit when it detects electric arcs that are a signature of loose connections in home wiring. Loose connections, which can develop over time, can sometimes become hot enough to ignite house fires.
Most, but not all, homes will have a need for additional AFCI protection based on varied municipal enforcement and the numerous changes for which areas require AFCI protection. Evaluate your risk exposure. Consider adding AFCI protection where needed for improved safety, particularly where construction was completed 2002 or later.
Modern Locations Where AFCI Protection is Known to Improve Safety:
Dwelling Units. All 120-volt, single-phase, 10-, 15-, and 20-ampere branch circuits supplying outlets or devices installed in the following locations:
Kitchens, Family Rooms, Dining Rooms, Living Rooms, Parlors, Libraries, Dens, Bedrooms, Sunrooms, Recreation Rooms, Closets, Hallways, Laundry Areas, or similar areas.
Testing AFCI Function
The inspector uses push button at AFCI breakers, where installed, to confirm AFCI protection trips. Once tripped, the inspector checks indexed electrical circuits to determine where AFCI protection is present or missing.
Obvious locations lacking AFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired AFCI receptacles or breakers are listed in the summary of the report. Evaluate your risk exposure.
AFCI Modernize Add More
Consider modernizing electrical installation adding further AFCI protection for improved electrical and fire safety. If installation of additional AFCI protection is desired, consult a knowledgeable, competent, qualified electrical contractor for specific requirements in your area.
GFCI
GFCI Residential
What is Ground Fault Circuit Interrupter (GFCI) Protection?
GFCI protection is an electrical safety device that interrupts an electrical circuit when the current passing through a conductor is not equal and opposite in both directions, therefore indicating an improper flow of current such as leakage of current to ground or current flowing to another powered conductor. The device's purpose is to reduce the severity of injury caused by an electric shock.
Most, but not all, buildings will have a need for additional GFCI protection based on varied municipal enforcement and the numerous changes for which areas require this type of protection. The list below is based off the 2023 standard that may or may not have been adopted by the local municipality. Evaluate your risk exposure. Consider additional GFCI protection where needed for improved safety.
Modern Locations Where GFCI Protection is Known to Improve Safety in Dwelling Units.
(A) Dwelling Units
All 125-volt through 250-volt receptacles installed in the following locations and supplied by single phase branch circuits rated 150 volts or less to ground shall have ground-fault circuit-interrupter protection for personnel:
(1) Bathrooms
(2) Garages and also accessory buildings that have a floor located at or below grade level not intended as habitable rooms and limited to storage areas, work areas, and areas of similar use.
(3) Outdoors
(4) Crawl spaces - at or below grade level
(4) Basements
(5) Kitchens
(6) Areas with sinks and permanent provisions for food preparation, beverage preparation, or cooking
(7) Sinks - where receptacles are installed within 1.8 m (6 ft) from the top inside edge of the bowl of the sink
(8) Boathouses
(9) Bathtubs or shower stalls - where receptacles are installed within 1.8 m (6 ft) of the outside edge of the bathtub or shower stall
(10) Laundry areas
(12) Indoor damp and wet locations
Some exceptions apply, see current standard for a list of exceptions.
(B) Pertains to Other Than Dwelling Units
(C) Crawl Space Lighting Outlets. GFCI protection shall be provided for lighting outlets not exceeding 120 volts installed in crawl spaces.
(D) Specific Appliances. GFCI protection shall be provided for the branch circuit or outlet supplying the following appliances rated 150 volts or less to ground and 60 amperes or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle fill stations
(3) High-pressure spray washing machines
(4) Tire inflation machines V
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(13) Microwave ovens
(E) Equipment Requiring Servicing. GFCI protection shall be provided for the receptacles required near Equipment Requiring Servicing.
(F) Outdoor Outlets. For dwellings, all outdoor outlets, including outlets installed in the following locations, and supplied-by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, shall be provided with GFCI protection:
(1) Garages that have floors located at or below grade level.
(2) Accessory buildings
(3) Boathouses
Note: Some exceptions apply, see current standard for a list of all exceptions.
Testing GFCI Function
The inspector uses an electrical tester at accessible 120V electrical receptacles that simulates a remote ground fault current to confirm which areas lack proper GFCI protection at tested 120V electrical receptacles.
Obvious locations lacking GFCI protection are listed in the body of the report.
Obvious broken, non working and improperly wired GFCI receptacles or breakers are listed in the summary of the report.
GFCI Modernize Add More
Consider adding GFCI protection for for one or more electrical receptacles or electrical circuits where GFCI protection is known to improve safety at the following areas:
- Kitchen Range
- Clothes Dryer
If installation of additional GFCI protection is desired, consult a competent electrical contractor.
Receptacle Outlets
Lighting/Ceiling Fans
Lighting
Service lighting was missing for Water Heater at Basement.
- Existing lighting at area did not properly illuminate service area for appliance and additional lighting should be installed.
Equipment requiring periodic servicing should have permanent lighting installed near such equipment that illuminates the control side of the equipment. This service lighting should be controlled by a switch that is installed at the entry point to the area where the equipment is installed. Consider properly adding additional lighting where needed near such equipment for improved safety and to facilitate servicing equipment when needed.
Smoke Alarms
Smoke Alarm Installation: Where Should Smoke Alarms be Installed?, Smoke Alarms Were Present
Depending on the age and location of the home, installation of smoke alarms are either recommended or required for improved safety.
Modern smoke alarm systems typically are hardwired to the electrical system and will have battery backup so that they will function when the power is off to the building. Modern smoke alarm systems typically have all smoke alarms interconnected so that when one alarm sounds then all smoke alarms will sound simultaneously. This is useful for heavy sleepers and in larger homes.
Modern smoke alarm systems typically have smoke alarms installed at the following locations:
- In the immediate vicinity outside sleeping areas
- Inside sleeping areas
- At least one per floor level including basements
- Near stairs
- In unfinished basements
- (some installations will require additional smoke alarms)
It is important to note that a single smoke alarm can satisfy multiple areas if carefully placed.
It is common to have a single smoke alarm near the top of the stairs and just outside multiple sleeping areas.
Properly maintain smoke alarm system as needed for life safety.
Regarding Testing Smoke Alarms:
Test smoke alarms weekly to ensure proper function for life safety. Replace batteries when needed. Properly replace smoke alarms when not functioning correctly and at least once every ten years. Smoke alarms should be at least the photoelectric type and dual sensor photoelectric and ionization smoke alarms are available, and preferred. Refer to installation and care instructions for proper locations and periodic maintenance.
The inspector does not test smoke alarms. For safety, the inspector only accesses smoke alarms from the installed flooring. To prevent damage, the inspector does not remove smoke alarms or open smoke alarm covers.
Smoke alarms were observed at inspected property for the applicable areas listed above. Properly maintain and test smoke alarms for improved safety.
STRUCTURE
Attic Access
Attic Access: Scuttle Hole
Attic Access: Not Floored
Attic area viewed from access point only due to lack of walk boards. Some areas of attic may not have been viewed.
Roof Framing
Framing: Rafters, Wooden
Sheathing: OSB
Roof Framing: Ridge Board Undersized
The ridge board appeared undersized at the attic roof framing. The bottom edge of the ridge board at top of the attic roof framing should meet the bottom edge of the roof rafter cut at the top portion of the roof framing. In some cases the roof rafters may crack over time. Monitor area properly correcting if condition changes. No correction was necessary when inspected.
Ceiling Framing
Ceiling Framing: Wood
Framing Access: Finished and Insulated Restricted
Finished areas restricted view of structural components. Visibility was limited due to installed insulation in this area. Some areas were not observed by inspector.
Wall Framing
Underfloor Access
Basement: Semifinished
Basement Semifinished
Some areas were finished. The components behind the finished areas were not observed. Concealed areas are not part of the inspection performed.
Underfloor Description
Attributes: Basement Semi Finished
Underfloor Area
Access:
- Basement walked
Construction Type:
- Basement - Semi Finished
Foundation:
- Concrete Block
- Poured in Place Concrete
Columns or Piers:
- Load Bearing Wall
Floor Structure:
- Floor Joists - Solid Wood
- Beam - Built Up Wood
- Subfloor - OSB
INSULATION
Above Ceiling Insulation
Recommended Insulation
Recommended attic insulation depth above living spaces for this area of the country is R-38 to R-60 to help lower utility costs. This recommendation comes from the US Department of Energy. Evaluate your comfort level and utility costs correcting insulation depth if needed.
Insulation Type: Blown In, Roll or Batt
Observed Insulation Approximate Depth: R - 38, R - 25
Wall Insulation
Insulation: Wall Insulation Not Observed, Undetermined
VENTILATION
Attic Ventilation
Attic Exhaust Vents: Ridge Roof Vent
Attic Intake Vents: Soffit Vents Where Installed
ROOF
Roof Covering
Method of Roof Inspection: Walked on portions of roof, Portions not visible
Portions of roofing were not visible from ground at rear and were not accessible from an 18' ladder. Such areas were not observed by inspector.
Roof Style: Multi Plane
Approximate Age of Roof Covering: 4-6 Years
Roofing Material: Composition Dimensional Shingle
Observation: Serviceable, Fulfilling Its Function
The roof covering overall was found generally serviceable within the parameters of its given service life. All roofing requires periodic maintenance. Properly maintain and correct roof covering as needed, when needed.
Roof Penetrations
Plumbing Vent Flashing
Plumbing Vent Flashing at Roof
Monitor this type of penetration as the flashing around the plumbing waste pipe that penetrates the roof requires periodic replacement. Budget replacement of plumbing vent flashing as the gaskets begin to deteriorate and split. This is needed each 8-10 years after a new plumbing vent flashing is installed.
Gutters and Downspouts
Gutter and Downspout Materials: Metal
Observation: Partial Gutters
Downspout: Under
Gutters: Maintain
Properly maintain rain gutters to meet your needs.
SIDING and TRIM
Masonry Siding
Siding - Concrete Tile
What is Concrete Tile Siding?
Concrete Tile Siding, also known as Adhered Concrete Masonry Veneer or Manufactured Masonry Veneer, is a non structural, light weight concrete product that is not made of natural stone. Concrete tile siding resembles stonework because real stone are used to make castings that are filled with light weight concrete and are stained to appear similar to natural stone. Concrete tile siding is absorbent and requires a proper moisture management system be in place before applying the concrete tile to exterior areas. Since the moisture management system is beneath the concrete tile, after the tile are installed the moisture management system is no longer readily visible. The best time to inspect the moisture management system is during installation. Most adhered concrete tile installations should follow the Masonry Veneer Manufacturers Association Installation Guide and Detailing Options for Compliance with ASTM C1780. ACMV.
Concrete tile siding observed irregular and further evaluation is recommended.
Installation irregularities were observed. Adhered concrete tile siding areas should be further evaluated and properly repaired or replaced by a competent qualified contractor that specializes in the installation of this type siding material and is familiar the installation standard. Properly correct any affected areas damaged by improper installation, if present.
Representative Photos Provided
- Siding observed too close to Soil and Pavement
- Some concrete tile observed cracked
- Some concrete tile observed loose
- Irregular transition was observed at dissimilar materials
Siding - Vinyl
Vinyl Siding, Vinyl Eaves with Metal Trim
Siding: Corrections Needed
Exterior siding/trim was ready for proper corrections when inspected.
Inspector Observations - Representative Photos Provided
- Deferred Maintenance Observed
- Loose Siding Observed
What you should do.
- Properly replace or repair exterior siding and trim as needed. Properly correct any adjacent affected areas damaged by deferred maintenance.
Trim
Trim Material: Wood where installed
Trim: Serviceable
Trim -
The exterior readily visible areas of the trim were inspected and appeared to be in overall serviceable condition, fulfilling its function. All trim requires maintenance. Properly maintain siding condition correcting when needed.
DECK
Deck or Wooden Porch Areas Overall Condition Statement
Correct Deck and Fall Areas Before Use
Inspecting decks which are also known as wooden porches.
Decks and their attached steps are inspected for structural integrity, fall prevention and possible entrapment openings. Concealed areas such as deck footers are not included in the inspection. Most inspected decks will be ready for some correction or upgrade due to age, wear or improper construction. For any areas ready for upgrade, you should evaluate your risk exposure properly correcting as needed for improved structural integrity and improved safety.
Any deck needing correction should be further reviewed and corrections performed by a Competent Qualified Deck Contractor as the deck inspection performed in this report is not meant to discover every possible correction that a deck might need.
Each deck should be properly stained to prolong deck life. A solid deck stain is preferred as it will also protect the deck from sun light damage.
Two useful sources for deck information may be found at the following websites:
https://knoxcounty.org/codes/pdfs/construction_info/DeckInformation.pdf
Deck areas were observed ready for corrections now and before use to improve the structure of the deck and to improve the safety aspects for the fall prevention measures installed at deck areas. Refer to the full report for additional information and photos regarding obvious corrections recommended now for any deck areas. A competent deck contractor should check all deck areas. Make deck areas functional, safe and structurally sound where needed.
- Representative Photos Provided
Deck or Wooden Porch Location, Attributes and Restrictions
Deck or Wooden Porch Structure
Bolts: Not Present
Deck bolts were not observed. Decks should be properly bolted to the structure every 12", 16" or 24" depending on the span of the floor joists. Deck bolts should be ½” diameter lag bolts with washers. The installed bolts should be staggered top to bottom to prevent splitting of the ledger board. Proper correction should be completed to strengthen the deck connection to the structure.
Joist Hangers: Missing At End Joist
Ledger Strip: Present, Not Installed Correctly
Joist framing at deck into the side of a ledger board or beam should be properly supported by approved joist hangers. Consider upgrade for outdated ledger strip installation for improved structural integrity and safety at deck by replacing any ledger strip with properly installed joist hangers.
Deck or Wooden Porch Railings and Stairs
Diagram: Correction Needed Railing & Stairs
Railings: Risers ≥4", Return Not Present
Stairs: Stair Connection, 5/4" Treads Over Spanned
Stairs Repair/Replace
Evaluate your risk exposure. Consider proper repair or replacement of steps and railings where needed now for safety and function.
LOTS and GROUNDS
Driveway
Porch
Stairs and Railings at Exterior
Vegetation
Vegetation Maintenance
Properly maintain vegetation to meet your needs. Vegetation should not touch building exterior or overhang roof. Vegetation should not interfere with access or servicing of electrical, gas or heating/cooling equipment.
Site
No adverse conditions were observed, maintain to meet your needs.
End of Report