The Scope and Purpose of a Home Inspection
Purchasing property involves risk
Buying a home—whether for yourself, your family, or as an investment—is a major decision. It’s not just about money; it’s about where and how you’ll live. My role is to support you in this process by offering a clear, honest, and detailed look at the condition of the property on the day of the inspection.
This home inspection is a limited, visual review of the building. It’s designed to help you better understand what you’re buying, not to give you a guarantee or make the decision for you. Old homes, new builds, quirky spaces, and fixer-uppers all come with their own stories and surprises—and that’s okay. My job is to help you see the parts that are visible and raise awareness about what may be hidden, uncertain, or outside the inspection’s scope.
I believe that good decisions come from good information. You won’t hear “don’t worry” from me—I’ll give you what I see, what I know, and what I don’t. That includes moments where I simply don’t have full access or where something needs a specialist’s opinion. Whenever possible, I encourage you to attend the inspection. Being there gives you a richer, real-time understanding of the property that’s hard to capture fully in a written report.
Whether you’re buying your first home or your fifth, in Lisbon or Leiria, the goal is the same: make informed, confident decisions about where you’ll live, grow, or invest.
This report is prepared in accordance with the terms of your inspection agreement with SEGUNDOS AFAMADOS - LDA and reflects the conditions observed on the date of inspection.
A home inspection is not an insurance policy
A home inspection is not a warranty or insurance policy. It won’t protect you from future problems or guarantee that nothing will go wrong with the house. Think of it instead as a snapshot of the property’s condition on a specific day, taken by someone who knows what to look for.
A home inspection is visual and not destructive
The inspection is visual and non-invasive. That means I don’t move furniture, open walls, dismantle equipment, or disturb finishes. I inspect only what’s accessible and visible without causing damage. Some systems—like overflow drains or waterproofing—can’t be tested without risk to the structure and are therefore excluded from direct testing. Tools such as thermal cameras or moisture meters may be used to support these observations. These tools provide visual context only and are not calibrated instruments for diagnostic or certified measurements.
This is not an inspection for code compliance
In Portugal, like many countries, there is no single national standard for home inspections, and we don’t check for compliance with municipal building codes. Code compliance is something typically reviewed by licensed architects or municipal officials during the construction phase, not after the home is finished. Building codes also evolve frequently, and older homes are not required to meet the latest standards unless major renovations are done.
In short: this inspection won’t catch everything, and it’s not meant to. But it will give you grounded, expert feedback on what’s visible and noteworthy—and that can make a world of difference in your planning and decision-making.
This is just our opinion
Every house is a little different—each with its own quirks, history, and construction choices. There’s no single “correct” way to build or repair everything, and that’s part of what makes homes so unique.
This report reflects my professional opinion, based on 20+ years of experience restoring and evaluating properties. But it’s still just that—an informed opinion. Other inspectors or contractors might see things differently, and that’s okay. You’re always welcome to get second opinions, especially on complex systems or repairs.
What I offer is context and perspective. I don’t just note problems; I explain them. And when something’s uncertain, I’ll say so. That might mean recommending further evaluation by a specialist, or simply highlighting something that’s outside the scope of this inspection.
In the end, this report isn’t a checklist—it’s a conversation starter. It gives you the groundwork to make your next steps with clarity and confidence.
The scope of this inspection
This inspection includes a visual evaluation of the exterior, roof, structure, foundation, attic, interior spaces, plumbing, electrical, and heating systems. I also assess conditions related to indoor air quality and the potential for mold growth where relevant. In some cases, I use tools such as a moisture meter, thermal camera or other handheld testers to gather additional visual context. These tools assist in visual evaluation but are not used to deliver technical measurements, official diagnostics, or precise readings. Any findings based on these tools will be included in the report where applicable.
Only areas that are accessible and safe on the day of the inspection will be included. When more detailed analysis is necessary, I’ll note it and recommend appropriate follow-up.
For clients who request it, I offer floor plans as an additional service. These are for reference only and are not intended for permitting, renovation planning, or any official use.
Your expectations
The goal of this inspection is to help align your expectations with the home you’re planning to buy. No home is perfect—every property has a history, and part of my job is to give you a clear picture of what that looks like on the day of the inspection.
I aim to highlight what’s working, what might need attention, and what’s unknown. This isn’t about finding every flaw—it’s about helping you make an informed decision. If you’re expecting a checklist of every minor issue, this report won’t provide that. But if you’re looking for guidance grounded in experience and transparency, that’s exactly what this offers.
This process is about discovery. It’s about seeing the home with informed eyes so you can decide how it fits into your plans.
How to Read This Report
Getting the Information to You
This report is designed to be clear and approachable, even if you’re not familiar with construction terms.
The full report includes photos, captions, descriptions, and links to more information to help you understand what you’re seeing. Some words or phrases may be highlighted and underlined—clicking on these will take you to additional resources or definitions.
You’ll also notice the use of emojis throughout the report. These are visual markers meant to draw your attention to specific items—they are not used to indicate the severity of an issue. The true meaning of each observation is described in the associated text and clearly labeled with a severity modifier.
For the best experience, I recommend reading the report online. It’s interactive, easy to navigate, and allows you to dive deeper into any areas that matter most to you. You can also download it as a PDF, and if needed, I can provide a high-quality translation to Portuguese.
Chapters and Sections
This report is organized into chapters, each covering a major part of the home. Within each chapter, you’ll find sections that focus on specific systems or components—like the roof, plumbing, or electrical. This structure makes it easy to navigate and understand the findings.
You’ll see most sections begin with a brief description in standard text. If I’ve observed something notable—whether it’s a concern or just something worth explaining more—you’ll find a colored box with a narrative. These narratives are meant to help you understand not just what was seen, but what it might mean in context.
Observation Labels used for Home in Mafra
Observations are numbered, colored, and labeled for clarity. The labels follow a standard set of observation modifiers, which define the nature and severity of each observation. If something is functioning as expected, the report may simply note “tested” or “inspected,” and no further comment will be needed.
Detailed description of various aspects of the property noted during the inspection.
Summary
Critical Issues
- ED-1 Exteriors and Decks:
DECK:
The balcony structure had some issues and no attempt to document all these issues will be made in this report. The bulleted lists, narratives and/or pictures related to the information below should be seen as more representative as opposed to all inclusive and other concerns should be anticipated. Concerns were noted in relation to:
SURFACE:
- Debris obscuring drainange — not fully inspected — visibility restricted due to leaf buildup, stored items, or vegetation
- 🚩 Mechanical damage to interior — visible cracks and interior damage suspected from patio floor area water leakage
IMMEDIATE REPAIRS SUGGESTED- drains should be cleaned and debris removed to prevent further damage to interior wall
Repair or Replace
- G-1 Grounds:
PATIO AND WALKWAY CONDITIONS:
There were numerous conditions documented below in bulleted lists, narratives, and/or pictures related to the Patio. Conditions should be evaluated, maintained and repaired by a qualified party as deemed necessary. In many cases, routine monitoring and basic maintenance will address typical wear and settling found on patios. Condition should be reviewed periodically, especially in areas where sidewalks are subject to heavy use or near vegetation.
WALKWAYS AND PATIO:
- Cracking evident — water infiltration may cause undermining and premature surface failure
- Trip hazards present — defined here as vertical displacement greater than 5 mm
- Displacement — surface offset or shifting noted
- Settlement evident — sunken areas suggest compaction or drainage failure
- Moss-covered — may create slippery conditions and indicates moisture retention
DRAINAGE:
- Ability of patio to drain away water not determined — inspection limitations prevented confirmation of drainage slope
- Ponding should be anticipated — surface configuration likely to retain water during rain events
I recommend evaluation, repairs, and improvements by a qualified party as deemed necessary.
- G-2 Grounds:
PROPERTY STORAGES SHEDS/STRUCTURES:
There were issues documented below in bulleted lists, narratives and/or pictures related to the storage sheds. While structures around the home are generally not inspected except as to how they impact the home, as a courtesy, I still report safety concerns and general conditions when warranted. All storage sheds should be maintained and inspected periodically. Your due diligence is advised. Further evaluation is recommended by a qualified party .
Storage sheds
SHED GENERAL CONDITIONS:
- Roof covering in poor condition — [asphalt / metal / tile] roof shows signs of [age / wear / leaks]
- Visible roof leaks / staining inside
- Damaged or missing trim — [corner boards / eaves / fascia]
- Mechanical damage — impact damage from [lawn equipment / vehicle / tree branches]
- Doors do not open / close properly — [hinge failure / misalignment / swelling from moisture]
- Evidence of rodent or insect activity — [droppings / nesting / chewed material]
- Paint / surface coating deteriorated — exposes material to further weathering
- ED-3 Exteriors and Decks:
EXTERIOR TRIM:
There were issues documented below in bulleted lists, narratives and/or pictures related to the trim of the home. There are conditions that should be evaluated and repaired as deemed necessary by a qualified party. Any damaged materials should be replaced and maintained as deemed necessary.
TILE TRIM:
- TILE pulling away or loose — fall hazard and structural detachment risk
- Trim behind or in contact with other surfaces — risk of trapped moisture or damage
MECHANICAL DAMAGE:
- Mechanical damage noted — dents, bends, or deformation observed on trim surfaces
- ES-1 Electric Service:
ELECTRICAL SERVICE EQUIPMENT:
There were issues documented below in bulleted lists, narratives and/or pictures related to the electrical service equipment that should be evaluated or repaired as deemed necessary by the licensed electrical contractor.
MULTIPLE LUGS:
- Improper Hot Terminal Connections – Multiple wires connected to a single terminal; though common, using dedicated junction terminals is safer and more compliant
- Loose or Overheated Terminations — loose, corroded, or overheated wires on terminals increase the risk of failure or fire and should be corrected immediately by a licensed electrician
🔨Repair ➕ Upgrade 🛑 Safety
- P-1 Plumbing:
Improperly sealed water storage tank – The lid on the water storage tank was not properly secured, and visible outdoor contaminants (such as debris or insects) were found inside the container. This condition may pose a risk to water quality. The tank should be thoroughly cleaned, and the lid properly installed or replaced to prevent further contamination.
- BIDS-1 Building Interiors, Doors and Stairs:
STAIR CONDITIONS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the stairs that indicate the need for evaluation, repairs and maintenance by a qualified stair installation contractor. I recommend such work prior to use of the stairs.
HANDRAILS:
- Handrail loose — movement noted under normal use; may detach or shift dangerously
🛑 Safety 🔨Repair 🔍 Due Diligence
- BIDS-2 Building Interiors, Doors and Stairs:
WALLS AND CEILINGS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the ceilings:
WALL/CEILING CONCERNS;
- Mechanical damage present – punctures, scrapes, or dents to wall or ceiling finishes
- Shrinkage or settlement cracks observed – minor cracking consistent with seasonal or material movement
- Evidence of prior repairs – patches, color mismatch, or retexturing visible
- Condensation staining noted – high humidity or poor ventilation likely cause
- Signs of past or active water damage – discoloration, swelling, or bubbling of surface
- Moisture confirmed by meter reading – elevated levels support need for further assessment
I recommend evaluation, repairs and maintenance by a qualified party as desired.
Recommended Improvements
- ED-2 Exteriors and Decks:
BUILDING EXTERIOR:
There were issues documented below in bulleted lists, narratives and/or pictures related to the Building's Exterior. The following concerns should be evaluated and repaired by a qualified party as deemed necessary. Hidden damage in exterior cladding is common and should be anticipated.
EXTERIOR CONDITION:
- Cracked stucco surfaces — minor cracking typical of aging or settlement
MOISTURE PROTECTION:
- Signs of historic water penetration — staining or material degradation visible at wall bases
Building exterior needs widespread cleaning of organic growth
- ED-4 Exteriors and Decks:
WINDOW CONDITIONS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the windows of the home. I recommend further evaluation, repairs and improvements of these conditions by a qualified window installation/repair contractor.
GENERAL CONDITIONS:
- (Some issues are documented below but should be viewed as representative, not exhaustive.)
EXTERIOR WINDOW BLINDS:
- Non-functional — no motor response — failure of electric motor or switch, possibly from breaker
- Difficult to operate — manual shutter mechanism stiff, jammed, or uneven
SECURITY BARS AT GROUND FLOOR:
- 🚩 Manual release mechanisms missing and necessary — windows or doors requiring escape and rescue access must have operable manual release devices; recommend installation by a qualified security bar company prior to using the room as a sleeping area
SCREENS:
- Damaged screens — torn or punctured; recommend repair or replacement
Some of the issues will be documented in the pictures below but should not be construed to be all inclusive but instead more representative.
👁🗨 Monitor 🔍 Due Diligence 🔧 Maintenance 🛑 Safety ➕ Upgrade 🔨Repair 🐞 WDO’s
- RACG-1 Roof, Attics, Chimney and Gutters:
CLAY TILE CONDITIONS
There were issues documented below in bulleted lists, narratives, and/or pictures related to the roof surface that should be evaluated, repaired and maintained by a qualified roofing contractor or other qualified party. The pictures below document some of the concerns related to this roof and should not be construed to mean there are no other conditions that need to be addressed. Hidden damage is common with roofs.
CLAY TILE CONCERNS:
- Organic growth – Moss, algae, or lichen present; can retain moisture and degrade tiles over time.
- Tiles missing and out of position – Gaps or dislodged tiles observed; compromises roof’s protective layer.
- Some tile edges have been sealed – Waterproofing measures have been taken in some localized locations that could indicate previous moisture intrusion .
GENERAL CONDITIONS:
- Evidence of repairs/patching – visible signs of previous repairs
- Misplaced tile should be put into correct position
- Some evidence of tile edge sealing could indicate previous moisture intrusion
- Organic growth should be removed to increase the ability of rain water to flow quickly off the roof in lower pitched areas
- P-2 Plumbing:
GAS TANKLESS WATER HEATER:
There were issues documented below in bulleted lists, narratives, and/or pictures related to the water heater has the conditions discussed below that should be further evaluated and repaired as deemed necessary by a licensed plumber (or in some cases, repairs can be made by other qualified parties):
DRAIN:
- Not a proper place of termination – termination location does not meet best practice or safety guidance
- K-1 Kitchen:
KITCHEN SINKS/COUNTERTOPS/CABINETS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the Kitchen sink, cabinets, and countertops:
FAUCET:
- Leaking at Control Lever – Dripping observed from faucet lever; repairs recommended.
CABINET CONCERNS:
- Mechanical Damage – Cabinet surfaces or hinges are visibly damaged.
- Staining of Cabinets – Water, food, or cleaning agent staining is evident.
I recommend evaluation and repair by a qualified party.
leak
The Full Report
Electric Service
Electric Service Main Panel
Main Panel Photo Bucket
Main Panel Observations
Sub Panel
Sub Panel Observations
Electric Distribution and Finish Wiring
Branch Wiring
Electrical Distribution and Finish Wiring Observations
General Comments
Building Characteristics, Conditions and Limitations
Style of Home: Contemporary (Contemporâneo 🇵🇹)
Type of Building : Detached House (Moradia Independente 🇵🇹)
Approximate Year of Original Construction: Estado Novo Era:, 1998
Reported Area: 391m2
Reported Bedrooms: T4
Reported Bathrooms: 5+
Attending the Inspection: Listing Agent, Buyer's Agent
Personal Belongings Present: No
Occupancy: Unoccupied, for 1.5 years
Animals Present: No
Weather during the inspection: Sunny
Approximate temperature during the inspection: 20°C to 25°C
Last Measurable Rain : more than one month
Ground/Soil surface conditions: Dry
Front Façade Orientation: South (Sul 🇵🇹)
Pre-1999 Structures: Abestos
Homes constructed prior to 2005 in Portugal may contain asbestos in various building materials, including roofing panels, insulation, floor tiles, pipe insulation, and certain textured wall or ceiling coatings. Asbestos is not considered a health risk when intact and undisturbed, but it becomes hazardous if the material is damaged or deteriorates, releasing fibers into the air. Inhalation of asbestos fibers can cause serious health problems, including asbestosis, mesothelioma, and lung cancer. It is strongly recommended not to disturb suspected asbestos-containing materials. If renovations or repairs are planned, especially in older homes, a licensed professional should evaluate the materials and, if necessary, conduct testing and removal in accordance with applicable safety regulations. For safety, materials suspected of containing asbestos should be left intact and encapsulated unless professional removal is required.
Thank you for reviewing this sample report from Ajuda Home Inspection.
We provide independent home inspections across Portugal — including Lisbon, Cascais, Porto, the Algarve, and the Silver Coast. Our detailed reports help buyers, sellers, and renters move forward with confidence.
👉 Learn more, see additional reports, or book an inspection: www.ajudahomeinspection.pt
Grounds
Grounds Information
Clearance to Grade: Standard Clearances
Property Slope: Moderate
Buildings on moderate slopes, can have water related issues that can not be adequately predicted or observed in a Standard Home Inspection. Vigilant monitoring of the sub-surface spaces (and the grading around the building) is recommended. Water intrusions/conditions should be evaluated/repaired by a licensed drainage installation company that utilizes the services of a licensed geo-technical engineer.
Downspout Discharge: Above and below grade
Driveway Composition: Brick
Walkway Composition: Brick, Concrete
Patios: Brick, Tile
Existing Landscape Vegetation : Mediterranean shrubs
Trees/Vegetation near building: No
Landscape Vegetation Information: Neglected vegetation
Fences: Block
Outbuildings, Trellises, Storage Sheds, Barns: Storage shed, Several outbuildings
Grounds Limitations and Exclusions: No recent rains
A Standard Home Inspection does not include evaluation of elements such as playground equipment, site lighting, outbuildings, irrigation systems, barbecues, and sheds. Evaluation of these elements, if present, may be warranted, any comments made or made as a courtesy, whether done verbally or included in the written report.
The following limitations and exclusions were noted:
Grounds Observations
FENCES AROUND THE PROPERTY:
There were issues documented below in bulleted lists, narratives and/or pictures related to the Fences. While fences around the home are generally not inspected except as to how they impact the home, as a courtesy, I still report safety concerns and general conditions when warranted. All fences should be maintained and inspected periodically. . In Portugal, fences located directly on the property boundary are typically considered shared property, and maintenance or replacement costs may be shared between neighbors, unless otherwise stated in formal agreements or property deeds. I make no determination as to ownership or responsibility. Your due diligence is advised. Further evaluation is recommended by a qualified party .
GENERAL FENCE CONCERNS:
- Vegetation overgrowth on fence — may contribute to moisture retention and damage
GATE CONDITONS:
- Locked and not tested — full operational check not performed due to security lock
- Rusting — visible corrosion on metal components like hinges, frames, or latches
- Failing paint / protective coating — peeling, chipping, or worn surface, increasing exposure to weathering
PATIO AND WALKWAY CONDITIONS:
There were numerous conditions documented below in bulleted lists, narratives, and/or pictures related to the Patio. Conditions should be evaluated, maintained and repaired by a qualified party as deemed necessary. In many cases, routine monitoring and basic maintenance will address typical wear and settling found on patios. Condition should be reviewed periodically, especially in areas where sidewalks are subject to heavy use or near vegetation.
WALKWAYS AND PATIO:
- Cracking evident — water infiltration may cause undermining and premature surface failure
- Trip hazards present — defined here as vertical displacement greater than 5 mm
- Displacement — surface offset or shifting noted
- Settlement evident — sunken areas suggest compaction or drainage failure
- Moss-covered — may create slippery conditions and indicates moisture retention
DRAINAGE:
- Ability of patio to drain away water not determined — inspection limitations prevented confirmation of drainage slope
- Ponding should be anticipated — surface configuration likely to retain water during rain events
I recommend evaluation, repairs, and improvements by a qualified party as deemed necessary.
Play structures present but not evaluated – Numerous fixed objects and installations on the property appear to be intended for children’s play or recreational use. These features were not evaluated for safety or compliance with applicable standards as part of this inspection. If they are to be used, especially by children, a full safety assessment by a qualified professional is strongly recommended to help reduce the risk of injury.
PROPERTY STORAGES SHEDS/STRUCTURES:
There were issues documented below in bulleted lists, narratives and/or pictures related to the storage sheds. While structures around the home are generally not inspected except as to how they impact the home, as a courtesy, I still report safety concerns and general conditions when warranted. All storage sheds should be maintained and inspected periodically. Your due diligence is advised. Further evaluation is recommended by a qualified party .
Storage sheds
SHED GENERAL CONDITIONS:
- Roof covering in poor condition — [asphalt / metal / tile] roof shows signs of [age / wear / leaks]
- Visible roof leaks / staining inside
- Damaged or missing trim — [corner boards / eaves / fascia]
- Mechanical damage — impact damage from [lawn equipment / vehicle / tree branches]
- Doors do not open / close properly — [hinge failure / misalignment / swelling from moisture]
- Evidence of rodent or insect activity — [droppings / nesting / chewed material]
- Paint / surface coating deteriorated — exposes material to further weathering
Exteriors and Decks
Info for Exteriors and Decks
Trim Material: Granite
Siding Material: Stucco, Stone cladding
Exterior Doors: Tilt and Turn, Fireproof, Steel Security Door
Exterior of Windows: Thermally Broken Aluminum
Window opening types: Tilt and Turn
Deck, Porches, Balconies: Present, Open Terrace
Guardrail: Metal, Tempered Glass Panels
Decking materials: TILE
Exterior and Deck Observations
DECK:
The balcony structure had some issues and no attempt to document all these issues will be made in this report. The bulleted lists, narratives and/or pictures related to the information below should be seen as more representative as opposed to all inclusive and other concerns should be anticipated. Concerns were noted in relation to:
SURFACE:
- Debris obscuring drainange — not fully inspected — visibility restricted due to leaf buildup, stored items, or vegetation
- 🚩 Mechanical damage to interior — visible cracks and interior damage suspected from patio floor area water leakage
IMMEDIATE REPAIRS SUGGESTED- drains should be cleaned and debris removed to prevent further damage to interior wall
BUILDING EXTERIOR:
There were issues documented below in bulleted lists, narratives and/or pictures related to the Building's Exterior. The following concerns should be evaluated and repaired by a qualified party as deemed necessary. Hidden damage in exterior cladding is common and should be anticipated.
EXTERIOR CONDITION:
- Cracked stucco surfaces — minor cracking typical of aging or settlement
MOISTURE PROTECTION:
- Signs of historic water penetration — staining or material degradation visible at wall bases
Building exterior needs widespread cleaning of organic growth
EXTERIOR TRIM:
There were issues documented below in bulleted lists, narratives and/or pictures related to the trim of the home. There are conditions that should be evaluated and repaired as deemed necessary by a qualified party. Any damaged materials should be replaced and maintained as deemed necessary.
TILE TRIM:
- TILE pulling away or loose — fall hazard and structural detachment risk
- Trim behind or in contact with other surfaces — risk of trapped moisture or damage
MECHANICAL DAMAGE:
- Mechanical damage noted — dents, bends, or deformation observed on trim surfaces
WINDOW CONDITIONS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the windows of the home. I recommend further evaluation, repairs and improvements of these conditions by a qualified window installation/repair contractor.
GENERAL CONDITIONS:
- (Some issues are documented below but should be viewed as representative, not exhaustive.)
EXTERIOR WINDOW BLINDS:
- Non-functional — no motor response — failure of electric motor or switch, possibly from breaker
- Difficult to operate — manual shutter mechanism stiff, jammed, or uneven
SECURITY BARS AT GROUND FLOOR:
- 🚩 Manual release mechanisms missing and necessary — windows or doors requiring escape and rescue access must have operable manual release devices; recommend installation by a qualified security bar company prior to using the room as a sleeping area
SCREENS:
- Damaged screens — torn or punctured; recommend repair or replacement
Some of the issues will be documented in the pictures below but should not be construed to be all inclusive but instead more representative.
👁🗨 Monitor 🔍 Due Diligence 🔧 Maintenance 🛑 Safety ➕ Upgrade 🔨Repair 🐞 WDO’s
Garage
Garage General
Garage Type: Detached
Overhead Door Type: Metal
Automatic Opener: Present
Garage Slab: Concrete
Garage Wall Surface: Finished
Ventilation / Environmental: Ventilation openings present (natural or mechanical)
Thermal & Moisture Performance: Evidence of moisture intrusion (staining, rusting)
Garage Observations
GARAGE GOOD CONDITION NOTED: The following garage-related components were reviewed and found to be functioning as expected at the time of inspection: Garage Floor, Overhead Door, Automatic Opener, and Garage Exterior Door. Materials and mechanical features showed no visible deficiencies, and operation appeared consistent with their intended use. Photos are included for reference and to support future comparisons as the property continues to age and settle.
Roof, Attics, Chimney and Gutters
Roof info
Method of Roof Inspection: Viewed with drone
Roof Style: Hip
Roof Structure: Dimensional Lumber
Roof Covering Materials: Portuguese Roof Tile (Telha Antiga Portuguesa):
Flashings: Roof Designed Without flashing
Overlay Roof: No
Chimney: Masonry
Skylights: Pivoting roof windows
Roof Inspection Limitations / Exclusions: Includes attic spaces
This report provides an opinion of the general condition of the roof system based on a visual inspection of representative areas. The inspector does not offer an opinion or warranty as to whether the roof leaks or is subject to future leakage.
- Water stains on ceilings, walls, and soffits that tested dry at the time of inspection may test elevated for moisture under other conditions or at another time.
- Specific notation of leakage or stains does not preclude additional areas of leakage and/or hidden damage. Monitor attic for any changes; ongoing or questionable situations should be assessed and corrected. Leakage can lead to Mold or Mold-like/Fungal Growth.
- It is common for there to be multiple layers of different kinds of insulation in the attic. It is possible for hidden layers to be discovered especially when the attics could not be inspected. The following limitations were present:
LIMITATIONS TO INSPECTION OF ROOF/STRUCTURES:
- Not walked on
- Dry for some time
- Lichen growth in some areas
Roof, Attic, Chimney and Gutter Observations
ROOF AREA CONDITIONS: There were issues documented below in bulleted lists, narratives, and/or pictures related to the roof area components that should be evaluated and repaired as deemed necessary by a qualified party.
🚩When the attic is not traversed or only partially traversed there will be much that cannot be determined, such as:
ATTIC VENTS:
- Vents are present in some areas — installation not continuous; may lead to uneven ventilation
- Additional vents recommended — existing system may not provide sufficient airflow
ROOF INSULATION:
- Thermal bridging noted – Structural elements not covered by insulation (e.g., concrete beams) create cold spots, increasing energy loss and condensation risk. These are often observable via infrared imaging or visible staining.
- Insulation missing and/or out of place/insufficient as noted with infrared camera – Inconsistent thermal patterns may indicate incomplete insulation or displacement of rigid panels. These findings should be further evaluated, especially in homes subject to energy certification.
PAST/ONGOING MOISTURE IN ATTIC/ROOF SPACE:
- Water stains observed in attic – Stains noted, particularly near the access hatch, tested negative for moisture at the time of inspection. Limited attic access due to low clearances prevented a comprehensive assessment. These stains may be remnants from prior roof leaks, or interior moisture accumulation
- Water stains tested negative for moisture by meter – Stains present but no active moisture detected at the time of inspection; continue to monitor.
PRESENT MOISTURE IN ATTIC/ROOF SPACE:
- Thermal bridging visible or suspected – Cold transfer through concrete or poorly insulated framing may be visible via darkened stains or thermal scanning, especially at transition walls.
PAST MOISTURE IN ATTIC/ROOF SPACE:
- Thermal bridging was observed or suspected – Lightened areas or signs from thermal scans suggested heat transfer through structural elements lacking adequate insulation, particularly around junctions with vertical walls.
MOLD OR WHAT LOOKS LIKE MOLD:
- Localized fungal growth observed – Small patches of black, green, or white discoloration were noted. These may be signs of active mold, often caused by moisture intrusion or condensation. Recommend cleaning by the owner if under 1 m² or evaluation by a qualified remediation professional.
🔧 Maintenance (as needed) 👁🗨 Monitor
ROOF WINDOW CONDITIONS:
There were issues documented below in bulleted lists, narratives, and/or pictures related to the roof windows that should be evaluated as deemed necessary by a qualified party.
FLASHINGS:
- Repair tape applied around skylight - could indicate previous leak, monitor area for future leaks
CLAY TILE CONDITIONS
There were issues documented below in bulleted lists, narratives, and/or pictures related to the roof surface that should be evaluated, repaired and maintained by a qualified roofing contractor or other qualified party. The pictures below document some of the concerns related to this roof and should not be construed to mean there are no other conditions that need to be addressed. Hidden damage is common with roofs.
CLAY TILE CONCERNS:
- Organic growth – Moss, algae, or lichen present; can retain moisture and degrade tiles over time.
- Tiles missing and out of position – Gaps or dislodged tiles observed; compromises roof’s protective layer.
- Some tile edges have been sealed – Waterproofing measures have been taken in some localized locations that could indicate previous moisture intrusion .
GENERAL CONDITIONS:
- Evidence of repairs/patching – visible signs of previous repairs
- Misplaced tile should be put into correct position
- Some evidence of tile edge sealing could indicate previous moisture intrusion
- Organic growth should be removed to increase the ability of rain water to flow quickly off the roof in lower pitched areas
Electric Service
Electric Service Main Panel
Service Power: Three-Phase Service Amperage Options (20.7 kVA (~30A per phase))
Service Entrance: Below Grade
Main Electric Panel Location: Entry
RCD breaker: labeled all
Electrical System Limitations/Exclusions: Panel Information
The following conditions limited inspection of the electrical system:
LIMITATIONS:
- Some breakers were off during inspection
Main Panel Photo Bucket
Primary electrical equipment location is in the front entry room
Main Panel Observations
MAIN PANEL GOOD CONDITION NOTED: The main electrical service components listed below were inspected and found to be in proper working order at the time of inspection: Service to Property, Electrical Service Equipment, and RCD breaker. Equipment appeared well-secured, free of visible defects, and functioning as expected under normal load conditions. As with all critical systems, regular monitoring and timely servicing by a qualified electrician are recommended to maintain long-term safety and performance. Photos are included for reference.
ELECTRICAL SERVICE EQUIPMENT:
There were issues documented below in bulleted lists, narratives and/or pictures related to the electrical service equipment that should be evaluated or repaired as deemed necessary by the licensed electrical contractor.
MULTIPLE LUGS:
- Improper Hot Terminal Connections – Multiple wires connected to a single terminal; though common, using dedicated junction terminals is safer and more compliant
- Loose or Overheated Terminations — loose, corroded, or overheated wires on terminals increase the risk of failure or fire and should be corrected immediately by a licensed electrician
🔨Repair ➕ Upgrade 🛑 Safety
Sub Panel
Sub Panel Location: Garage, Utility room, Bedroom, Throughout property
RCD breaker: labeled bathroom
Electrical System Limitations/Exclusions: Panel Information
Sub Panel Observations
Sub Panel Observations: Multiple subpanels present – Subpanels were installed in nearly every outbuilding on the property. Each panel was inspected and appeared to be in good condition with no visible deficiencies noted. However, the overall electrical configuration and load distribution were not fully traceable during this inspection. If any concerns arise regarding system capacity, grounding, or code compliance, a full evaluation by a licensed electrician is recommended.
Electric Distribution and Finish Wiring
Branch Wiring
Wire Material: Copper
Receptacles Outlets: Some tested
Light fixtures present: Some
It is normal practice in Portugal for lighting fixtures to be removed when a homeowner or tenant moves out of a property. While this is standard it does limit the ability to test lighting circuits during an inspection. Without fixtures in place, functionality and proper wiring cannot be verified. It is recommended that fixtures be installed by a qualified electrician to ensure safe and correct operation.
Lighting Outlets: Some tested
Electrical System Limitations/Exclusions: Miscellaneous information
The following conditions limited inspection of the electrical system:
MISCELLANEOUS INFORMATION:
- Low voltage wiring systems, including timers and sensors, are not part of this inspection.
- Security and alarm systems are not within the scope of this inspection.
- Auxiliary, low voltage, electric or electronic equipment (e.g., TV, doorbell, computer, cable, lightning protection, surge protection, low voltage lighting, intercoms, site lighting, etc.,) is not performed as part of a standard home inspection.
Electrical Distribution and Finish Wiring Observations
LIGHTING OUTLET CONDITIONS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the lighting components in the home including:
FIXTURES:
- Fixtures removed – base or wiring left exposed at previous fixture location
- Non-functional lighting – fixture not operating at one or more locations
- Burned-out bulbs – suspected cause of non-functionality
- Missing bulbs – bulb not installed at fixture
- Missing components – elements such as trim or lenses are absent
SWITCHES:
- Switch covers missing – Missing at several locations or removed for painting; ensure they are reinstalled
While the pictures below document some of these concerns, I recommend all lighting locations be evaluated and maintained as deemed necessary by a licensed electrical contractor.
ELECTRICAL WIRING GOOD CONDITION NOTED:The electrical distribution components and finish wiring listed below were inspected and found to be in good working condition at the time of inspection. ELECTRICAL and AFCI / RCD Devices appeared properly installed, with no visible signs of overheating, damage, or unsafe modification. While routine use and future upgrades may introduce new demands, the current system appears to support typical household loads safely. Photos are included for reference and documentation.
Plumbing
Supply Plumbing
Water Supply: Public water
Meter: Located at, Right corner of property
Main Water Shut-off: Meter
Functional Water Flow: Excellent
Pressure Reducing Valve: None noted
Recirculation Loop: None Noted
Pipe Insulation: Not visible
Exterior Hose Bibs: Operating, Vac Breaker not found
Additional Sinks: Not tested
Water Filters: Present
Supply Plumbing Photo Bucket
Water supply limited – The main water service from the city was turned off at the time of inspection, and water was also shut off at the house. However, the on-site storage tank contained enough water to test an outdoor spigot and verify basic pump operation. A full system test could not be performed, but the pump ran smoothly during limited testing, and no visible or obvious issues were noted in the pump house. Further evaluation is recommended once full water service is restored.
Plumbing Observations
Improperly sealed water storage tank – The lid on the water storage tank was not properly secured, and visible outdoor contaminants (such as debris or insects) were found inside the container. This condition may pose a risk to water quality. The tank should be thoroughly cleaned, and the lid properly installed or replaced to prevent further contamination.
Sprinkler system not tested – The irrigation system was present on the property, but I was unable to operate or test it during the inspection. No evaluation of functionality, coverage, or control systems was performed. Photos are included for reference only. If the system is to be used, testing by the homeowner or a qualified technician is recommended.
Water Heater
System Type: Heat Pump / electric hybrid, Tank-less
Energy Source: Gas, Electricity
Water Heater Photo Bucket
Water heater not fully evaluated – The home’s water supply was off at the time of inspection, so the water heater could not be operated or fully tested. No visible leaks or obvious damage were observed. The garage-mounted unit includes multiple valves and controls that appear more complex than a standard residential setup; the buyer should request an explanation, operating instructions, and any available service records from the seller or installer before use.
Water Heater Observations
GAS TANKLESS WATER HEATER:
There were issues documented below in bulleted lists, narratives, and/or pictures related to the water heater has the conditions discussed below that should be further evaluated and repaired as deemed necessary by a licensed plumber (or in some cases, repairs can be made by other qualified parties):
DRAIN:
- Not a proper place of termination – termination location does not meet best practice or safety guidance
Drainage Plumbing
Drains/Vents
Waste Pipe and Venting: Public Sewer
Floor Drains: Present
Drainage Plumbing Limitations and Exclusions: Present
The following limitations and exclusions related to the plumbing of the home were noted:
DRAINAGE:
- Unable to inspect drainage plumbing without water supplied to house
Fuel Storage and Distribution
General Comments
Fuel type: PLG (propane)
PLG Storage Tank: Above ground tank
PLG tank location: Gargage
Propane shut-off location: At tank
Gas Meter: None noted
Fuel Storage and Distribution Observations
GAS PIPING AND STORAGE TANKS:
There were issues documented below in bulleted lists, narratives, and/or pictures related to the following concerns were noted related to the gas piping and storage tanks on the property. I recommend maintenance as deemed necessary.
- Tanks should be secured and not resting on a stack of tiles.
- Fuel tank compartment being used as storage for combustible materials
- Fuel tank lid is not properly installed
🛑 Safety
Heating, Cooling, Fireplaces and Ventilation
Heating System
Energy Source: Oil
Heating Method: Hydronic boiler
Heating/Cooling Limitations and Exclusions: Not tested
The following limitations and exclusions related to heating and cooling were noted:
HEATING SYSTEM NOT TESTED DUE TO:
- No water to furnace
- Gas shut off
Carbon Monoxide Detectors: None located
Smoke Alarms: None Located
Room directly heated:Kitchen
Living room
Dining
All Bathrooms
All Bedrooms
Building Interiors, Doors and Stairs
Floors, Walls, Ceilings, Trim and Closets
Floor coverings: Tile
Wall/Ceiling Finishes: Drywall, Tile, Plaster
Stairs and Railings: Standard
Interior Observations
STAIR CONDITIONS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the stairs that indicate the need for evaluation, repairs and maintenance by a qualified stair installation contractor. I recommend such work prior to use of the stairs.
HANDRAILS:
- Handrail loose — movement noted under normal use; may detach or shift dangerously
🛑 Safety 🔨Repair 🔍 Due Diligence
WALLS AND CEILINGS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the ceilings:
WALL/CEILING CONCERNS;
- Mechanical damage present – punctures, scrapes, or dents to wall or ceiling finishes
- Shrinkage or settlement cracks observed – minor cracking consistent with seasonal or material movement
- Evidence of prior repairs – patches, color mismatch, or retexturing visible
- Condensation staining noted – high humidity or poor ventilation likely cause
- Signs of past or active water damage – discoloration, swelling, or bubbling of surface
- Moisture confirmed by meter reading – elevated levels support need for further assessment
I recommend evaluation, repairs and maintenance by a qualified party as desired.
Kitchen
Kitchen Info
Floor/Wall/Ceilings Coverings: Tile
Countertop Material: Stone
Cabinet Material: Plastic laminate
Ventilation method: Fan Ducted to Exterior
Dishwasher: Not Operated
Microwave: Functioned
Ovens: Functioned
Kitchen Limitations/Exclusions: General Information
Evidence of past leaks under kitchen sinks is common. While I endeavor to verify current leaks at the time of inspection sometimes leaks are incidental or due to specific uses not duplicated at the time of inspection. Monitoring of moisture conditions under sinks should be a normal part of routine home maintenance.
Appliances are not moved during the inspection.
Inspection of appliances, if done, should be considered "casual" and should in no way be construed to mean function is adequate. Any testing done is more related to whether they turn on/off or not, not how well they function or do not function. Any information provided is merely a courtesy, as our Standards of Practice do not require inspection of built-in or portable appliances.
KITCHEN LIMITATIONS:
- Water Shut off
Kitchen Observations
KITCHEN SINKS/COUNTERTOPS/CABINETS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the Kitchen sink, cabinets, and countertops:
FAUCET:
- Leaking at Control Lever – Dripping observed from faucet lever; repairs recommended.
CABINET CONCERNS:
- Mechanical Damage – Cabinet surfaces or hinges are visibly damaged.
- Staining of Cabinets – Water, food, or cleaning agent staining is evident.
I recommend evaluation and repair by a qualified party.
leak
Laundry Facilities
Laundry Info
Washer: Not tested
Laundry Sink: Not tested
Laundry Ventilation: Fan
Laundry Observations
FLOORS/WALLS/CEILINGS/CLOSETS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the walls:
WALL CONCERNS:
- Mechanical damage present – punctures, scrapes, or dents to wall or ceiling finishes
- Condensation staining noted – high humidity or poor ventilation likely cause
I recommend evaluation by a qualified party as desired.
Bathrooms
Bathroom info
Sinks & Cabinets: Not tested
Toilet: Not tested
Bathtub: Not tested
Shower: Not tested
Bathroom Ventilation: Passive Vent
Bathroom Limitations/Exclusions: General Bathroom Information
The following limitations and information were present related to the bathroom:
BATHROOM LIMITATIONS:
- Water Supply shut off / winterized
Bathroom Observations
BATHROOM SINKS/COUNTERTOPS/CABINETS:
There were issues documented below in bulleted lists, narratives and/or pictures related to the sink. Water was off, photos provided as a reference
I recommend evaluation and improvements by a licensed plumber.
- Bathroom handle was stiff to operate and has evidence of ongoing leak
- sink has some corrosion from possible leak
Indoor Climate
Climate Info
This indoor air quality (IAQ) assessment aims to provide insight into the presence of airborne substances that may influence the health, safety, and comfort of building occupants. PM2.5 refers to fine particulate matter smaller than 2.5 microns, which can penetrate deep into the lungs and is often produced by combustion sources like cooking, smoking, or outdoor pollution. PM10 includes larger particles such as dust, pollen, and mold fragments that may cause irritation or trigger allergies. Formaldehyde (HCHO) is a volatile organic compound commonly released from pressed wood products, furniture, and construction materials; it is a known respiratory irritant and potential carcinogen. Total Volatile Organic Compounds (TVOCs) represent a group of chemical pollutants emitted from products like paints, cleaning agents, and air fresheners, some of which may cause headaches, dizziness, or longer-term effects with chronic exposure.
Carbon monoxide (CO) is a colorless, odorless gas produced by incomplete combustion—typically from stoves, heaters, or vehicles—and can be dangerous even at low concentrations. Carbon dioxide (CO₂), while not directly harmful in typical residential concentrations, is a key indicator of indoor ventilation quality; elevated levels suggest insufficient fresh air exchange. Radon is a radioactive gas that seeps from soil and rock into basements and lower levels of buildings; long-term exposure is a leading cause of lung cancer in non-smokers. Together, these measurements form a broad picture of the air’s chemical and particulate composition, offering an early indication of potential environmental concerns.
This indoor air quality assessment is intended as a preliminary screening based on instantaneous, localized measurements taken with portable instrumentation. While care has been taken to ensure accuracy, results may vary depending on environmental conditions at the time of inspection, including ventilation, temperature, occupancy, and recent activity. The data collected does not substitute for long-term monitoring, laboratory-grade testing, or specialized evaluations for medical or regulatory compliance. This report does not constitute a health diagnosis nor a certification of air safety. Where elevated readings are observed, further investigation or consultation with an indoor environmental professional is recommended. No guarantee is made regarding ongoing conditions after the time of inspection.
To help control indoor humidity and minimize the buildup of condensation or surface mold, it is important that occupants follow routine cleaning and moisture management practices. This includes:
- Keeping surfaces dry, particularly around windows, bathroom walls, tile grout, kitchen splash zones, and other high-humidity areas.
- Wiping down condensation-prone surfaces with a soft cloth and a non-chlorine mold-resistant cleaner — such as hydrogen peroxide or vinegar-based solutions — to remove light surface mold without damaging finishes.
- Avoiding drying clothes indoors without active ventilation or a dehumidifier, especially in rooms with limited airflow.
- Regularly cleaning extractor fans in bathrooms, kitchens, and laundry areas to ensure optimal airflow and vapor removal.
- Checking for minor leaks under sinks, behind washing machines, and around window frames, which may go unnoticed but contribute to chronic dampness.
Routine surface cleaning helps reduce both visible mold and microscopic organic debris that mold can feed on in humid environments. This practice, combined with improved airflow, can significantly reduce the risk of persistent indoor moisture problems and improve overall indoor air quality.
Indoor climate concerns, such as condensation, humidity, and ventilation, are often influenced by seasonal changes and occupant behavior. While I make observations using tools such as thermal imaging and moisture meters, this is not a comprehensive environmental or air quality analysis. Some conditions—such as intermittent condensation or periods of poor airflow—may not be present or detectable at the time of inspection. Factors like the use of shutters, heating equipment, exhaust fans, or window ventilation routines can significantly affect interior conditions.
No long-term monitoring of humidity, ventilation performance, or airflow patterns is performed. Moisture meters are used in select accessible areas only. This inspection does not include laboratory air sampling, mold testing, or HVAC airflow measurements.
INDOOR CLIMATE LIMITATIONS:
- Single-day inspection – Conditions represent only the moment of the inspection and may not reflect long-term or seasonal trends.
- No continuous environmental monitoring – Temperature, relative humidity, or dew point values were not tracked over time.
- No invasive inspection – Ceilings, walls, and floors were not opened or probed beyond accessible surfaces.
- No air sampling performed – No lab-based mold or air quality testing was conducted as part of this inspection.
- Weather may influence findings – Rain, temperature, and sunlight conditions may impact surface readings and interior comfort during the inspection.
Environmental Observations
INDOOR AIR QUALITY:
Air circulation observed in good condition – During the air quality sampling, airflow appeared adequate and no concerns were noted. Cross-ventilation was functioning effectively at the time of inspection. To help maintain healthy indoor air quality, regular cross-ventilation is encouraged, along with efforts to reduce interior moisture generation through proper use of kitchen and bathroom exhaust fans or dehumidifiers as needed.
INTERIOR MOISTURE:
Moisture-related conditions were evaluated using thermal imaging, non-invasive moisture meter readings, and visual inspection. Depending on environmental conditions and observed building features, signs of potential or active moisture intrusion were identified. These issues may be seasonal in nature or ongoing and are influenced by both environmental humidity and building design or maintenance. Where elevated readings, staining, or mold-like material is present, or if conditions suggest hidden or structural moisture, further evaluation by a qualified moisture remediation contractor to determine the source and appropriate corrective measures when wet weather returns
0% moisture content is an ideal level for interiors, 1-2% is typically what is seen. Moisture content levels as low as 6% can create paint failure issues and wide spread internal wall damage should be expected when moisture content exceeds 20%.
OBSERVED MOISTURE:
- Moderate moisture accumulation was detected -
- Evidence suggests a developing or repeat moisture issue needing ventilation, insulation, or heating improvements.
- • Readings ranged from 16% to 20% in localized areas
- • Slight paint bubbling, uneven wall sheen, or minor texture distortion observed
Affected areas previously discussed in this report showed signs of exterior moisture penetration.
Foundation
Foundation Info
Foundation Material: Poured concrete
Method of Inspection: No access
Basement: None
% of Foundation Not Visible: 100%
Basement Observations
Foundation not directly visible – The foundation was fully covered by stucco finishes and surrounding landscaping, preventing direct inspection. However, no excessive signs of structural settlement—such as cracks, sloping, or misalignment—were observed in the walls, floors, or ceilings above. Observations are limited to visible conditions and do not confirm the condition of concealed structural elements.