The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most homebuyers.
Your participation is requested
Your presence is requested during this inspection. A written report will not substitute for all the possible information that can be conveyed verbally by a shared visual observation of the conditions of the property.
How to Read This Report
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, descriptions, videos and hot links to additional information.
The best way to get the layers of information that are presented in this report is to read your report online (the HTML version), which will allow you to expand your learning about your house. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information. The HTML version of this report also contains streaming videos. Short video clips often contain important information and critical context and sounds that can be difficult to capture in words and still pictures.
For the most reliable viewing experience, I recommend viewing the report on as large a screen as practical, as much detail can be lost on small devices like smart phones. For similar reasons, reports should only be printed in color to retain as much detail as possible and minimize misinterpretation of photographs.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin.
Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section and it may simply say “tested,” or “inspected.”
Observation Labels
All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
- Significantly Deficient:"Significantly deficient" means that in my opinion the condition is unsafe, not functional, and or it is significantly different from normal standards of practice. For all issues that are significantly deficient I strongly recommend having qualified contractors specify steps and costs to remedy the conditions. Note, there are often multiple options that impact the intrusiveness, cost, and schedule for repairs.
- Repair:Repair is used to designate anything that the inspector thinks should be repaired, replaced, or mitigated in some way. In the inspectors opinion these concerns should be addressed. These may have safety and functionality impacts. Impacts may develop or worsen in the future. There are risks associated with items that need repair or maintenance. Items might be worse than they looked at time of inspection as things change and as more information becomes available. The person purchasing the property should decide what to ask the current owner for. Please note, your inspectors opinion of who should repair which items may be offered as a courtesy and should not be considered as part of the inspection or part of the purpose and scope of the inspection.
- Near End of Service Life:We can not predict the future or accurately predict when things will fail. I will mark items as being near the end of service life if, in my opinion, the device is likely to be near the end of it's service life. Factors impacting this educated guess include but are not limited to: The average for how long this type of equipment usually lasts. The current age (best guess). Apparent condition of equipment, conditions onsite, and state of maintenance. I recommend budgeting for all eventual replacements. For all home owners I recommend monitoring components regularly so you can replace items before they fail as appropriate.
- Maintenance:These are items that should be considered part of normal or routine home ownership activities. Items such as servicing the furnace, cleaning the gutters, or changing filters. These items are not required to be reported as part of the standard inspection. There will be similar items that are not included, not noted, and not reported. Please read manuals and product documentation for all components of the home. Please follow all manufacturers recommendations and all local, county, and state rules. Observations in this category are typically outside the scope of a standard inspection and should not be considered complete or material to the inspection.
- Improvement or Upgrade:This category is for observations that are not necessarily defects, but which could be improved for safety, efficiency, or reliability. One reason this may happen is because standards change (both written and informal standards). These conditions may be considered normal or common practice. Common conditions and common practices that are not best practice do have negative impacts. When any work is done I recommend upgrading to current standards where feasible to do so. This category may be used for items that the inspector considers to be cosmetic. Please note, these observations are outside the required standards for home inspection. I provide these comments as a courtesy. These observations should not be considered complete or material to the inspection.
- Note:Refers to aside information and or any comments elaborating on descriptions of systems or limitations to the inspection. This can include general information This the information may not apply directly to the inspected property. This information is not directly part of the property inspection and should not be considered complete. Observations in this category are often outside the scope of a standard inspection and should not be considered complete or material to the inspection.
- Inspectors Notebook:These are notes and technical information that aid in the inspection process. I may leave such information in the report for reference purposes. These notes include technical information. These notes may have information from codes and other sources. Please note, this inspection is NOT a code inspection. It is NOT a compliance inspection. Please consult with the authority having jurisdiction for rules, laws, and local requirements. This report is the inspectors opinion and recommendations. Acting as a home inspector I do not represent the authority having jurisdiction. Acting as a home inspector I have no enforcement authority.
Pest Inspection
All items with the bug logo () are part of a structural pest inspection. If your inspector included a structural pest inspection as a part of the scope of your home inspection, you can distinguish pest inspection items by this logo. You can also go to the pest inspection summary page to see a summary of the items that are part of a pest inspection.
Summary Page
The Summary Page is designed as a bulleted overview of all the observations noted during inspection. This helpful overview is not a substitution for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report as the Summary Page does not include photographs or photo captions.
Moisture Meter Testing
Where moisture meter testing is indicated in this report a Protimiter Survey Master Dual Function was used.
SUMMARY
Significantly Deficient
- S1-2 ◾Structure:
1 - Severely Rotted Girder – West End
Problem: The west end of the girder is severely rotted.
Effect: Significant wood deterioration may affect the structural support of the floor system.
Recommendation: Have a licensed contractor evaluate the west end girder and repair or replace as needed.
2 - Severely Rotted Sill Plate – West Side
Problem: The sill plate on the west side of the house is significantly rotted and deficient.
Effect: Deteriorated sill plates may affect structural support and allow continued deterioration over time.
Recommendation: Have a licensed contractor evaluate the west side sill plate and repair or replace as needed.
Repairs
- GAD-1 ◾Grounds And Drainage:
Negative Slope – Front Walkway
Problem: The front walkway has negative slope directing water between the foundation and the front porch slab.
Effect: Improper drainage may contribute to moisture intrusion and foundation-related concerns over time.
Recommendation: Have a licensed contractor evaluate the front walkway grading and repair as needed to direct water away from the structure.
- ES-1 ◾Exterior Structures:
Loose Soffit – South Rear East Side
Problem: The soffit on the south rear east side of the house is not fully secured or properly seated.
Effect: Loose soffit materials may allow moisture or pests to enter.
Recommendation: Have a licensed contractor evaluate the soffit on the south rear east side and repair as needed.
- ES-4 ◾Exterior Structures:
1 - Loose Siding – West Side
Problem: The bottom row of siding on the west side of the house is loose in the middle section.
Effect: Loose siding may allow moisture intrusion and further deterioration.
Recommendation: Have a licensed contractor evaluate the loose siding on the west side and repair as needed.
2 - Minor Siding Damage – West Side
Problem: Minor chips and damage were observed in the siding on the west side of the house.
Effect: Damaged siding may allow moisture intrusion over time.
Recommendation: Have a licensed contractor evaluate the damaged siding on the west side and repair as needed.
3 - Missing Mortar – Garage Foundation
Problem: Missing mortar was observed on the east front side of the garage exterior foundation.
Effect: Missing mortar may allow moisture intrusion and continued deterioration.
Recommendation: Have a licensed contractor evaluate the garage foundation mortar joints and repair as needed.
- ES-6 ◾Exterior Structures:
Rotted Deck Step Supports
Problem: The step leading up to the deck has rotted support areas on both sides.
Effect: Deteriorated support components may affect stability and worsen over time.
Recommendation: Have a licensed contractor evaluate the deck step supports and repair as needed.
- ES-8 ◾Exterior Structures:
1 - Rear West Bedroom Door Binding / Latching Issue
Problem: The rear west bedroom door drags against the carpet, is difficult to open, and does not latch properly.
Effect: Door does not operate or secure properly during normal use.
Recommendation: Have a licensed contractor evaluate the rear west bedroom door and adjust, shorten, or repair as needed.
2 - Missing Closet Door Floor Guides
Problem: All three bedroom closet doors are missing floor guides.
Effect: Closet doors swing freely in and out during operation.
Recommendation: Have a licensed contractor evaluate the bedroom closet doors and install floor guides as needed.
3 - Missing Door Stops
Problem: Multiple interior and exterior doors are missing door stops.
Effect: Doors may contact adjacent walls or trim and cause damage over time.
Recommendation: Have a licensed contractor evaluate the missing door stops and install as needed.
4 - Inoperable Utility Closet Window
Problem: The utility closet window next to the furnace could not be opened at the time of inspection.
Effect: Proper window operation could not be confirmed.
Recommendation: Have a licensed contractor evaluate the utility closet window next to the furnace and repair as needed.
- G-1 ◾Garages:
1 - Inoperative Garage Door Opener
Problem: The overhead garage door opener was not working at the time of inspection and appeared to have no power.
Effect: Proper operation and safety features of the garage door opener could not be confirmed.
Recommendation: Have a licensed contractor evaluate the overhead garage door opener and repair as needed.
2 - Manual Garage Door Operation Could Not Be Confirmed
Problem: The emergency/safety release could not be disengaged to manually test garage door operation.
Effect: Manual opening and closing of the garage door could not be confirmed.
Recommendation: Have a licensed contractor evaluate the garage door release mechanism and overall operation and repair as needed.
- S1-3 ◾Structure:
1 - Cracking / Displacement – Crawl Space Foundation
Problem: Cracking and displacement were observed in the block and mortar at the southeast corner of the crawl space.
Effect: Open gaps may allow moisture intrusion and continued deterioration over time.
Recommendation: Have a licensed contractor evaluate the crawl space foundation at the southeast corner and repair/seal as needed.
2 - Leaking Copper Sanitary Tee – Crawl Space
Problem: A copper sanitary tee beneath the kitchen sink on the south side of the crawl space has come disconnected and is leaking.
Effect: Ongoing leakage may contribute to elevated moisture conditions and deterioration in the crawl space.
Recommendation: Have a licensed contractor evaluate the copper sanitary tee beneath the kitchen sink and repair as needed.
3 - Leaking Copper Drain Pipe – Crawl Space
Problem: A 1-1/2 inch copper drain pipe on the south end of the crawl space has a hole and is leaking.
Effect: Ongoing leakage may contribute to elevated moisture conditions and deterioration in the crawl space.
Recommendation: Have a licensed contractor evaluate the leaking copper drain pipe in the crawl space and repair as needed.
4 - Shower Leak – Half Bathroom
Problem: The shower in the half bathroom is leaking into the crawl space.
Effect: Ongoing leakage may contribute to moisture-related deterioration beneath the home.
Recommendation: Have a licensed contractor evaluate the half bathroom shower and repair as needed.
5 - Elevated Moisture / Humidity – Crawl Space
Problem: High humidity and elevated moisture levels were observed in the crawl space at the time of inspection.
Effect: Excess moisture may contribute to deterioration, wood rot, and potential microbial growth over time.
Recommendation: Have a licensed contractor evaluate the crawl space moisture conditions and repair or improve conditions as needed.
- S-2 ◾Systems:
1 - Unconfirmed Garage Light Switch Function
Problem: The light switch located to the right in the garage could not be confirmed to control any visible fixture and may operate the exterior flood light above the front of the garage.
Effect: Switch function could not be fully confirmed during the inspection.
Recommendation: Further evaluation is recommended as needed.
2 - Inoperative Dining Room Ceiling Light
Problem: The dining room ceiling light was not working at the time of inspection, possibly due to a bulb issue.
Effect: Proper operation of the fixture could not be confirmed.
Recommendation: Have a licensed contractor evaluate the dining room ceiling light and repair as needed.
3 - Pull Chain Light Would Not Shut Off – Southwest Bedroom Closet
Problem: The pull-chain closet light in the southwest rear bedroom turned on, but the chain would not allow the light to be turned back off.
Effect: Fixture does not operate properly.
Recommendation: Have a licensed contractor evaluate the southwest rear bedroom closet light and repair as needed.
4 - Closet Lights Could Not Be Confirmed – Northeast / Southeast Bedrooms
Problem: The pull-chain closet lights in the northeast and southeast bedrooms could not be confirmed operational because bulbs were missing.
Effect: Proper operation of the fixtures could not be confirmed.
Recommendation: Install bulbs and evaluate further as needed.
5 - Unconfirmed Front Door Light Switch Function
Problem: The far-left light switch next to the front door could not be confirmed to control any visible fixture.
Effect: Switch function could not be fully confirmed during the inspection.
Recommendation: Further evaluation is recommended as needed.
6 - Inoperative Outlet – Southeast Bedroom South Wall
Problem: The outlet closest to the floor on the south wall in the southeast bedroom had no power at the time of inspection.
Effect: Proper outlet operation could not be confirmed.
Recommendation: Have a licensed contractor evaluate the southeast bedroom outlet and repair as needed.
7 - Inoperative Outlet – Southeast Bedroom East Wall
Problem: The outlet closest to the floor on the east wall in the southeast bedroom had no power at the time of inspection.
Effect: Proper outlet operation could not be confirmed.
Recommendation: Have a licensed contractor evaluate the southeast bedroom outlet and repair as needed.
8 - Kitchen Counter Outlets Not GFCI Protected
Problem: The two countertop outlets to the right of the kitchen sink are not GFCI protected.
Effect: Increased shock risk near water sources.
Recommendation: Have a licensed contractor evaluate the kitchen countertop outlets for proper GFCI protection and repair as needed.
9 - Missing Knockout Cover – Electrical Panel
Problem: A knockout opening in the electrical panel is missing a blank cover.
Effect: Openings may expose energized components and allow debris into the panel.
Recommendation: Have a licensed contractor evaluate the electrical panel opening and install a proper cover as needed.
10 - Double-Tapped Neutral – Electrical Panel
Problem: Two neutral wires are terminated under the same terminal screw in the electrical panel.
Effect: Improper terminations may lead to loose connections and electrical safety concerns.
Recommendation: Have a licensed contractor evaluate the neutral wire terminations in the electrical panel and repair as needed.
- S-5 ◾Systems:
1 - Loose Water Spigot – North Front Side
Problem: The water spigot on the north front side of the house is not properly secured.
Effect: Loose fixtures may move and lead to leaks or damage over time.
Recommendation: Have a licensed contractor evaluate the north front water spigot and secure as needed.
2 - Uncapped Gas Line – Laundry Room Dryer
Problem: The gas supply line for the laundry room dryer is not capped while no appliance is connected.
Effect: Uncapped gas lines may present a safety hazard.
Recommendation: Have a licensed contractor evaluate the laundry room gas supply line and properly cap it as needed.
Near End of Service Life
- S-7 ◾Systems:
Water Heater Beyond Typical Service Life
Problem: The water heater is well beyond its typical service life expectancy but was operating at the time of inspection.
Effect: Older units are more prone to reduced efficiency, leakage, and unexpected failure over time.
Recommendation: Have a licensed contractor evaluate the water heater and budget for replacement as part of normal home maintenance.
Maintenance Items
- ES-2 ◾Exterior Structures:
Standing Water in Gutters – Maintenance
Problem: The north front and south rear gutters contain standing water and debris buildup.
Effect: Improper drainage may allow water overflow and contribute to moisture-related issues.
Recommendation: Recommend cleaning the gutters as part of regular maintenance to help ensure proper drainage.
📚FULL REPORT
◾Grounds And Drainage
Surface Drainage
Walkways
Driveways
Patios
Retaining Walls
Crawlspace Vents And Wells
Window Wells
Egress / Basement Wells
Fencing
◾Introduction
Inspection Conditions
Contract Sent: Before Inspection
Contract Signed: Before Inspection
Property Type: Single Family (Detached)
Year of Construction (Estimated): Per Real Estate Listing, 1900
Temperature (Fahrenheit, Estimated): 50-60
Weather: Mild Conditions (☀️Clear)
◾Grounds And Drainage
Surface Drainage
Grading And Surface Drainage: Mostly Positive (Back, Both Sides), Negative slope primarily on the front porch concrete walkway
Vegetation: Normal Conditions
Negative Slope – Front Walkway
Problem: The front walkway has negative slope directing water between the foundation and the front porch slab.
Effect: Improper drainage may contribute to moisture intrusion and foundation-related concerns over time.
Recommendation: Have a licensed contractor evaluate the front walkway grading and repair as needed to direct water away from the structure.
Driveways
Driveways: Normal Conditions (Typical Cracking, Asphalt)
Patios
Patios: None
Retaining Walls
Retaining Walls: None Found
Crawlspace Vents And Wells
Crawlspace Vent Covers: Normal Conditions (Screen And Vent Maintenance Recommended)
Crawlspace Vent Wells: No Vents Below Grade
Window Wells
Window Wells: No Windows Below Grade
Egress / Basement Wells
Egress / Basement Wells: None Found
Retaining Walls: None Found
Fencing
Fencing: Not Inspected (Present)
◾Equipment And Utilities At Exterior
Electrical
Equipment Outside: See The Systems Chapter
Plumbing
Equipment Outside: See The Systems Chapter
Cooling
Equipment Outside: Not Inspected (Not Applicable)
Heating
Heating Equipment Outside: See The Systems Chapter
◾Exterior Structures
🛐Roof Coverings
Methods Used To Inspect Roof Coverings: Walked (Lower Roof, Upper Roof)
Roof Covering Description: Asphalt
Roof Covering Condition: Just one layer of shingles
Roof Drainage Systems: Gutters And Downspouts (Extensions Installed, Splash Blocks Present, Installed)
Flashings, Skylights, And Roof Penetrations: Normal Conditions Noted (Plumbing Vent Visible)
Chimneys And Flues: Normal Conditions Noted (Flue - Metal At Top)
Eaves, Soffits, And Fascias: Normal Conditions (Viewed From Ground)
Loose Soffit – South Rear East Side
Problem: The soffit on the south rear east side of the house is not fully secured or properly seated.
Effect: Loose soffit materials may allow moisture or pests to enter.
Recommendation: Have a licensed contractor evaluate the soffit on the south rear east side and repair as needed.
Standing Water in Gutters – Maintenance
Problem: The north front and south rear gutters contain standing water and debris buildup.
Effect: Improper drainage may allow water overflow and contribute to moisture-related issues.
Recommendation: Recommend cleaning the gutters as part of regular maintenance to help ensure proper drainage.
Wall Coverings
Description Of Exterior Wall Covering: Aluminum / Vinyl Siding
Exterior Wall Covering: Normal Conditions Noted (Maintenance Recommended - Caulk And Sealants), Materials (Vinyl)
Exterior Wall Flashing And Trim: Normal Conditions (Sealant Refresh Recommended)
Foundation Visible At Exterior: Limited View (Normal Conditions)
Penetrations: Normal Conditions (Caulk / Sealant Recommended)
1 - Loose Siding – West Side
Problem: The bottom row of siding on the west side of the house is loose in the middle section.
Effect: Loose siding may allow moisture intrusion and further deterioration.
Recommendation: Have a licensed contractor evaluate the loose siding on the west side and repair as needed.
2 - Minor Siding Damage – West Side
Problem: Minor chips and damage were observed in the siding on the west side of the house.
Effect: Damaged siding may allow moisture intrusion over time.
Recommendation: Have a licensed contractor evaluate the damaged siding on the west side and repair as needed.
3 - Missing Mortar – Garage Foundation
Problem: Missing mortar was observed on the east front side of the garage exterior foundation.
Effect: Missing mortar may allow moisture intrusion and continued deterioration.
Recommendation: Have a licensed contractor evaluate the garage foundation mortar joints and repair as needed.
Decks And Balconies
Attached Decks And Balconies: Normal Conditions (Regular Maintenance Recommended), Decks (1)
Attached Steps And Stairs: Concerns
Porches And Stoops
Attached Porches And Stoops: Normal Conditions Noted, Inspected (1)
Attached Steps And Stairs: Normal Conditions Noted
Stairs
Attached Steps And Stairs: See Other Sections
Doors And Windows
Exterior Doors: Normal Conditions (All Opened Closed And Locked), See Garage Section For Issues Noted
Windows: Normal Conditions Noted, Old Windows
Exterior Door Lighting: All Exterior Door Lighting (Present Not Tested - Timers And Sensors), Present Near Front Door
Doorbell: None Found
Screen And Storm Doors: Not Inspected - Accessories
1 - Rear West Bedroom Door Binding / Latching Issue
Problem: The rear west bedroom door drags against the carpet, is difficult to open, and does not latch properly.
Effect: Door does not operate or secure properly during normal use.
Recommendation: Have a licensed contractor evaluate the rear west bedroom door and adjust, shorten, or repair as needed.
2 - Missing Closet Door Floor Guides
Problem: All three bedroom closet doors are missing floor guides.
Effect: Closet doors swing freely in and out during operation.
Recommendation: Have a licensed contractor evaluate the bedroom closet doors and install floor guides as needed.
3 - Missing Door Stops
Problem: Multiple interior and exterior doors are missing door stops.
Effect: Doors may contact adjacent walls or trim and cause damage over time.
Recommendation: Have a licensed contractor evaluate the missing door stops and install as needed.
4 - Inoperable Utility Closet Window
Problem: The utility closet window next to the furnace could not be opened at the time of inspection.
Effect: Proper window operation could not be confirmed.
Recommendation: Have a licensed contractor evaluate the utility closet window next to the furnace and repair as needed.
Outbuildings
Outbuildings: Not Inspected
◾Garages
Attached Garage
Attached Garages: 1 Inspected
Overhead Doors: 1 Overhead Door, Lock Working
Overhead Door Operations: Issues Noted
Exterior Doors: No Person Sized Exterior Door
Electrical: Outlets Found (6 Or More), Issues Noted In Other Sections
Garage Doors - To Living Space: Listing Tag Present (Fire Separation Not Confirmed)
Heating And Plumbing: Plumbing In Garage
Windows: Same As Home, Opened Closed And Locked
Coverings: Normal Conditions Noted For Garage Finish (Cosmetic Damages Noted)
1 - Inoperative Garage Door Opener
Problem: The overhead garage door opener was not working at the time of inspection and appeared to have no power.
Effect: Proper operation and safety features of the garage door opener could not be confirmed.
Recommendation: Have a licensed contractor evaluate the overhead garage door opener and repair as needed.
2 - Manual Garage Door Operation Could Not Be Confirmed
Problem: The emergency/safety release could not be disengaged to manually test garage door operation.
Effect: Manual opening and closing of the garage door could not be confirmed.
Recommendation: Have a licensed contractor evaluate the garage door release mechanism and overall operation and repair as needed.
Garage (Freestanding)
Detached Garages: None Found
◾Interiors
Rooms
Walls, Ceilings And Floors: Normal Conditions Noted, Carpet (Normal Conditions Noted)
Interior Doors: Normal Conditions Noted, Opened Closed And Latched (Representative Number Tested)
Windows: Opened Closed And Locked (Representative Number)
Electrical: See Electrical Section
Closets: Lighting Noted
Bathrooms
Bathrooms: Inspected (2), All Bathroom Fixtures Working, No Active Leaking
Toilets: Flushed, No Active Leaking Found
Faucets / Sinks: Working, No Active Leaking (All Tested)
Showers / Bathtubs: Working, No Active Leaking (1 Combination Shower And Bathtub, 1 Shower)
Electrical: Outlet Near Water Tested And Reset, See Electrical Section
Bathroom Fans - Mechanical Ventilation: No Fan Installed (Bathrooms With Windows)
Cabinets And Countertops: Normal Conditions Noted
Walls Ceilings And Floors: Normal Conditions Noted
Doors: Opened Closed And Latched
Windows: Normal Conditions Noted
S-Trap Configuration – Half Bathroom
Problem: The half bathroom drain is configured as an S-trap.
Effect: S-traps can allow trap siphoning and potential sewer gas entry under certain conditions.
Recommendation: Consider upgrading the half bathroom drain configuration to a modern properly vented trap assembly as an improvement.
Kitchen
Kitchens: 1
Plumbing: Issues Noted In Other Sections
Disposal: Working
Dishwasher: Present, 1 Function Tested, No Active Leaking
Cabinets And Countertops: Normal Conditions Noted
Electrical: Outlets Near Water Tested And Reset, Issues Noted In Other Sections
Cooktop Exhaust Fan: Does Not Vent To Outside
Cooktop / Oven: 1 Function Tested
Refrigerator: Working (Measured Below 40 F), Freezer Working (Measured Below 0 F), Ice Maker (Dispenser Working, Ice Present), Water Dispenser (Working)
Microwave: Present (Door Working, Light Working, Display Working), Tested (Via Wet Paper Towel)
Walls Ceilings And Floors: Normal Conditions Noted
Doors / Windows: Normal Conditions
Stairs And Railings
Stairs And Railings: See Other Sections
Laundry
Laundry Areas: 1
Plumbing: No Laundry Sink
Washer Connections: Not inspected (None Installed)
Dryer Connections: Gas, Not Tested (No Installed Appliance)
Electrical: Normal Conditions Noted
Exhaust Fan: None Noted
Cabinets / Countertops: None Found
Laundry Chute: None Found
Walls / Floors / Ceilings: Normal Conditions Noted
Doors: Issues Noted In Other Sections
Windows: Issues Noted In Other Sections
◾Structure
🦇Attic Spaces
Attic Access: 1 Attic Space Accessed, Hatch, Accessed From (Garage)
Methods Used To Inspect attic: Walked Accessible Space
Roof Structure Visible: Normal Conditions Noted, Dimensional Lumber
Ceiling Structure: Obstructed View (Insulation)
Mechanical Ventilation / Fans: Obstructed View
Electrical: No Issues Found
Plumbing: Plumbing Vent Visible (Metal, Copper)
Insulation: Blown
Ventilation: Type (Roof Surface Vents, Soffit Vents, Gable Vents)
Coverings: Unfinished
Probed Structural Components: No Issues Noted (Representative number probed)
🗼Below Grade Spaces
Foundation Description: Crawlspace
Methods Used To Inspect Under Floor Spaces: Crawlspace (Crawled), Accessed (All Available Areas)
Structural Components, Foundations, And Framing: Concerns Noted
Probed Structural Components: High Humidity/Moisture Content
Floor Structure: Dirt Floor
Wall Structure: Materials (Block and Mortar)
Ceiling Structure: Dimensional Lumber, Beams (Wood)
Windows In Below Grade Spaces: None Below Grade
1 - Severely Rotted Girder – West End
Problem: The west end of the girder is severely rotted.
Effect: Significant wood deterioration may affect the structural support of the floor system.
Recommendation: Have a licensed contractor evaluate the west end girder and repair or replace as needed.
2 - Severely Rotted Sill Plate – West Side
Problem: The sill plate on the west side of the house is significantly rotted and deficient.
Effect: Deteriorated sill plates may affect structural support and allow continued deterioration over time.
Recommendation: Have a licensed contractor evaluate the west side sill plate and repair or replace as needed.
1 - Cracking / Displacement – Crawl Space Foundation
Problem: Cracking and displacement were observed in the block and mortar at the southeast corner of the crawl space.
Effect: Open gaps may allow moisture intrusion and continued deterioration over time.
Recommendation: Have a licensed contractor evaluate the crawl space foundation at the southeast corner and repair/seal as needed.
2 - Leaking Copper Sanitary Tee – Crawl Space
Problem: A copper sanitary tee beneath the kitchen sink on the south side of the crawl space has come disconnected and is leaking.
Effect: Ongoing leakage may contribute to elevated moisture conditions and deterioration in the crawl space.
Recommendation: Have a licensed contractor evaluate the copper sanitary tee beneath the kitchen sink and repair as needed.
3 - Leaking Copper Drain Pipe – Crawl Space
Problem: A 1-1/2 inch copper drain pipe on the south end of the crawl space has a hole and is leaking.
Effect: Ongoing leakage may contribute to elevated moisture conditions and deterioration in the crawl space.
Recommendation: Have a licensed contractor evaluate the leaking copper drain pipe in the crawl space and repair as needed.
4 - Shower Leak – Half Bathroom
Problem: The shower in the half bathroom is leaking into the crawl space.
Effect: Ongoing leakage may contribute to moisture-related deterioration beneath the home.
Recommendation: Have a licensed contractor evaluate the half bathroom shower and repair as needed.
5 - Elevated Moisture / Humidity – Crawl Space
Problem: High humidity and elevated moisture levels were observed in the crawl space at the time of inspection.
Effect: Excess moisture may contribute to deterioration, wood rot, and potential microbial growth over time.
Recommendation: Have a licensed contractor evaluate the crawl space moisture conditions and repair or improve conditions as needed.
❄️Insulation And Ventilation
Insulation And Vapor Retarders: Not Visible In Finished Areas, Noted In Unfinished Areas (Attic)
Ventilation: Attic Spaces (Ventilation Noted In Accessed Areas), Foundation Areas (Ventilation Noted In Accessed Areas)
Insulation Description: Coverings Prevented Access
Vapor Retarders - Description: Obstructed View (Finished Coverings, Not Visible)
Mechanical Ventilation: See Other Sections (Bathrooms, Kitchens)
Additions
Additions: There did not appear to be any additions.
◾Systems
Fireplaces
Fireplaces: None
🔥Heating
Heating Methods And Distinguishing Characteristics: Forced Air
Installed Heating Equipment: Working (Quick Test)
Energy Sources: Gas (Natural Gas)
Vent Systems, Flues, And Chimneys: PVC, Make Up Air Sources (Vent High And Low)
Manufacturers: Bryant
Year Of Manufacture (Estimated): Less Than 20 Years Old (2014)
Capacity (Estimated): Thousands Of BTU's (70-80)
Filters: Disposable, Location (Above Equipment)
❄️Cooling
Cooling Equipment Distinguishing Characteristics : No Central Cooling System Installed
⚡Electrical
Service (Drop / Lateral, Entrance Conductors, Cables, And Raceways): Overhead
Main Disconnect Locations: At Main Panel
Main Disconnects and Interior Of Service Equipment: One Main Panel Inspected
Service Grounding: Visible Components (Inside Panel)
Overcurrent Protection Devices: Issues Noted
Conductors Visible: Copper
Wiring Methods Noted: NMSC - Called Romex
Service Amperage Ratings (Not Measured): 100 Amps
Service Voltage Ratings (Not Measured): 120 / 240 Split Single Phase
Subpanel Locations: None Found
Subpanel Interior Components: None Found
Ground Fault Circuit Interrupters: GFCI Protection Confirmed (At All Expected Locations)
Lighting Fixtures: Inspected (Most Working Possible Bulb Issues), Issues noted
Switches: Issues noted
Receptacles (Outlets): Normal Conditions Noted (Representative Number Inspected)
Smoke Detectors: Present Not Tested
Carbon Monoxide Detector: I Recommend 2 New Detectors At Move In.
1 - Unconfirmed Garage Light Switch Function
Problem: The light switch located to the right in the garage could not be confirmed to control any visible fixture and may operate the exterior flood light above the front of the garage.
Effect: Switch function could not be fully confirmed during the inspection.
Recommendation: Further evaluation is recommended as needed.
2 - Inoperative Dining Room Ceiling Light
Problem: The dining room ceiling light was not working at the time of inspection, possibly due to a bulb issue.
Effect: Proper operation of the fixture could not be confirmed.
Recommendation: Have a licensed contractor evaluate the dining room ceiling light and repair as needed.
3 - Pull Chain Light Would Not Shut Off – Southwest Bedroom Closet
Problem: The pull-chain closet light in the southwest rear bedroom turned on, but the chain would not allow the light to be turned back off.
Effect: Fixture does not operate properly.
Recommendation: Have a licensed contractor evaluate the southwest rear bedroom closet light and repair as needed.
4 - Closet Lights Could Not Be Confirmed – Northeast / Southeast Bedrooms
Problem: The pull-chain closet lights in the northeast and southeast bedrooms could not be confirmed operational because bulbs were missing.
Effect: Proper operation of the fixtures could not be confirmed.
Recommendation: Install bulbs and evaluate further as needed.
5 - Unconfirmed Front Door Light Switch Function
Problem: The far-left light switch next to the front door could not be confirmed to control any visible fixture.
Effect: Switch function could not be fully confirmed during the inspection.
Recommendation: Further evaluation is recommended as needed.
6 - Inoperative Outlet – Southeast Bedroom South Wall
Problem: The outlet closest to the floor on the south wall in the southeast bedroom had no power at the time of inspection.
Effect: Proper outlet operation could not be confirmed.
Recommendation: Have a licensed contractor evaluate the southeast bedroom outlet and repair as needed.
7 - Inoperative Outlet – Southeast Bedroom East Wall
Problem: The outlet closest to the floor on the east wall in the southeast bedroom had no power at the time of inspection.
Effect: Proper outlet operation could not be confirmed.
Recommendation: Have a licensed contractor evaluate the southeast bedroom outlet and repair as needed.
8 - Kitchen Counter Outlets Not GFCI Protected
Problem: The two countertop outlets to the right of the kitchen sink are not GFCI protected.
Effect: Increased shock risk near water sources.
Recommendation: Have a licensed contractor evaluate the kitchen countertop outlets for proper GFCI protection and repair as needed.
9 - Missing Knockout Cover – Electrical Panel
Problem: A knockout opening in the electrical panel is missing a blank cover.
Effect: Openings may expose energized components and allow debris into the panel.
Recommendation: Have a licensed contractor evaluate the electrical panel opening and install a proper cover as needed.
10 - Double-Tapped Neutral – Electrical Panel
Problem: Two neutral wires are terminated under the same terminal screw in the electrical panel.
Effect: Improper terminations may lead to loose connections and electrical safety concerns.
Recommendation: Have a licensed contractor evaluate the neutral wire terminations in the electrical panel and repair as needed.
Fuse Panel Present (Improvement / Upgrade Recommendation)
Problem: The electrical system utilizes fuse protection rather than modern circuit breakers. Fuse systems are considered outdated by current standards.
Effect: Older fuse systems may limit the ability to incorporate certain modern electrical safety protections and upgrades commonly found in newer systems.
Recommendation: Consider upgrading the electrical system to a modern breaker panel for improved functionality, convenience, and compatibility with current safety features.
🚰Plumbing
Water Main Shutoff Location: Inside (Garage)
Water Main Interior Supply: Working
Water Main Interior Supply Piping Materials: Copper
Check Valve At Plumbing Supply: None Found
Plumbing Distribution: Copper, PEX
Interior Fixtures And Faucets: All Tested, Issues Noted In Other Sections
Drain, Waste, And Vent Piping Materials: Materials (Copper, Galvanized, PVC)
Drain, Waste, And Vent: All Fixtures Tested, Issues noted in other sections
Drainage Sumps, Sump Pumps, And Related Piping: None Found
Floor Drains: No Floor Drain - Pump Noted
Exterior Plumbing: 2 Faucets (Working)
Fuel Main Shutoff Locations: Outside (Back)
Fuel Storage And Fuel Distribution Systems: Black Pipe
1 - Loose Water Spigot – North Front Side
Problem: The water spigot on the north front side of the house is not properly secured.
Effect: Loose fixtures may move and lead to leaks or damage over time.
Recommendation: Have a licensed contractor evaluate the north front water spigot and secure as needed.
2 - Uncapped Gas Line – Laundry Room Dryer
Problem: The gas supply line for the laundry room dryer is not capped while no appliance is connected.
Effect: Uncapped gas lines may present a safety hazard.
Recommendation: Have a licensed contractor evaluate the laundry room gas supply line and properly cap it as needed.
🚿Water Heating
Water Heating Equipment Description: 1 Tank (40 Gal)
Water Heating Energy Sources: Gas (Natural Gas)
Water Heating Equipment: Working
Vent Systems, Flues, And Chimneys: Metal (Single Wall), Make Up Air Sources (Large Room)
Manufacturers: Pioneer
Year Of Manufacture (Estimated): 1988, Past Expected Life
Water Heater Cold Shutoff: Shutoff Present On Cold Line (Not Tested)
Water Heater Beyond Typical Service Life
Problem: The water heater is well beyond its typical service life expectancy but was operating at the time of inspection.
Effect: Older units are more prone to reduced efficiency, leakage, and unexpected failure over time.
Recommendation: Have a licensed contractor evaluate the water heater and budget for replacement as part of normal home maintenance.
◾Additional Information
Inspection Wrap Up
Client Present: Yes (For Some Of Inspection)
Occupancy: Vacant
Stove / Oven Settings: Confirmed Off
Thermostat Settings: Set To Pre-Inspection Settings
Doors Locked: Confirmed By Inspector (Keys Back In Lockbox)
Fireplace Dampers: Not Applicable
Thank You! 📝 Note
Thank you for coming to the inspection. Please contact me if you have questions at any time. It was a pleasure talking to you about the property. Congratulations, I hope that everything goes wonderful in your new home.
Limitations
The report does not address environmental hazards, for example: Lead-based paint, Treated lumber, Carbon monoxide, or Other similar environmental hazards, Cockroaches, Mold, Rodents, Radon, Asbestos, Pesticides, Mercury
The report does not address: Wood Destroying Insects, Wood Destroying Organisms, or Other pest / pest related issues
The report does not address subterranean systems or components (operational or nonoperational), for example: Fuel storage, Fuel delivery, Water supply, Water quality
The Following Limitations Apply Throughout This Report
General Limitations:
- All locations and photos are provided as a courtesy.
- Locations and photos are representative not all inclusive.
- Inside of chimneys and exhausts are not inspected.
- Cosmetic issues are excluded or only provided as a courtesy.
- I can not see underground.
- I can not see behind walls, even with electronic devices.
- I can not predict the future.