The Scope and Purpose of a Home Inspection

Purchasing property involves risk

The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend the inspection.

A home inspection is not an insurance policy

This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.

A home inspection is visual and not destructive

The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing which will limit the scope of the inspection.

This is not an inspection for code compliance

This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.

This is just our opinion

Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.

The scope of this inspection

This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.

Your expectations

The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most homebuyers.

Your participation is requested

Your presence is requested during this inspection. A written report will not substitute for all the possible information that can be conveyed verbally by a shared visual observation of the conditions of the property.

How to Read This Report

Getting the Information to You

This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, descriptions, videos and hot links to additional information.

The best way to get the layers of information that are presented in this report is to read your report online, which will allow you to expand your learning about your house. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information.

This report can also be printed on paper or to a PDF document.

Chapters and Sections

This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin.

Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section and it may simply say “tested,” or “inspected.”

Observation Labels

All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:

  • Repair:
    Repair and maintenance items noted during inspection. Please note that some repair items can be expensive to correct such as re-finishing hardwood floors, but are considered simply repair items due to their cosmetic nature.
  • Recommended Maintenance:
    These are repair items that should be considered "routine home ownership items," such as servicing the furnace, cleaning the gutters or changing the air filters in the furnace.
  • Monitor:
    Items that should be watched to see if correction may be needed in the future.
  • Due Diligence:
    Observation such as a buried oil tank that may require further investigation to determine the severity and / or urgency of repair.
  • Note:
    Refers to aside information and /or any comments elaborating on descriptions of systems in the home or limitations to the home inspection.
  • Description:
    Detailed description of various aspects of the property noted during the inspection.

Summary Page

The Summary Page is designed as a bulleted overview of all the observations noted during inspection. This helpful overview is not a substitution for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report as the Summary Page does not include photographs or photo captions.

Summary

Repairs

  • RCG-2 Roof, Chimney and Gutters:

    The skylights have not been properly secured to the curbs. This could allow water entry and even blow-off during heavy winds. Have this repaired by a qualified contractor to ensure the skylights are well sealed and screwed down.

  • ESDW-2 Exterior Siding, Doors and Windows:

    Localized rot repairs are needed to the exterior window trim on the South side living room and bedroom and as located. Hire a licensed general contractor to further evaluate and repair the exterior window trim system. Repair and replace all damaged and decaying exterior wood as needed. Please note that this condition can indicate additional concealed damage that is not visible to inspection.

  • G4-1 Garage:

    An unprotected opening was found in the garage wall and ceiling finishes. This should be repaired to complete the fire separation between the house and the garage. Large holes should be repaired with the proper sheetrock materials. Small holes and openings should be sealed with mud or high temperature of "fire stop" caulking. Openings with doors should employ listed fire-rated doors.

  • EDFW-2 Electric Distribution and Finish Wiring:

    The loose electric receptacle housing on the South exterior should be secured and sealed. Securing loose receptacles can often be done by just tightening some set screws between the receptacle and the junction box, though sometimes it can get more complex if the box itself is loose. Repair as needed. Replace the damaged GFCI receptacle at the northwest exterior corner near the front entry door.

Recommended Maintenance Items

  • RCG-1 Roof, Chimney and Gutters:

    Moss build-up was noted on the roof. This is bad for the roof covering as it can trap moisture on the roof and can inhibit drainage off the roof. Moss removal is recommended. Products such as Tide are not recommended as the bleach in these products can deteriorate the shingles. Pressure washers should not be used to clean the moss as they can damage the shingles unless the moss has been killed prior to washing. Only low pressure should be used to clean the roof of moss and chemicals should be used to kill the moss prior to removal. One product people use to kill the moss is baking soda. Hire a professional roof cleaning service to clean and service this roof to ensure proper control of roof runoff and proper drainage off the roof.

  • RCG-3 Roof, Chimney and Gutters:

    The gutters are clogged with organic debris and require cleaning to ensure proper control of roof runoff. Clean the gutters and ensure they are unobstructed, leak free and properly sloped to drain. This is routine house maintenance; I would expect the need to clean gutters and downspouts regularly.

  • HCFV-1 Heating, Cooling, Fireplaces and Ventilation:

    Annual servicing is recommended for safe and reliable performance from this hot water heating system. Hire a licensed heating contractor to service and further evaluate the systems.

Monitors

  • P2-1 Plumbing:

    This water heater is likely close to the end of its useful service life. The average life of a water heater is statistically 8-12 years though in practice, they can vary widely between 8-20 years depending on water quality and maintenance schedule such as frequency of flushing the tank and replacing sacrificial anodes. Budget to replace this water heater at any time. Water was hot at the time of inspection.

Due Diligences

  • AP-1 Additional Plumbing:

    An interior fire sprinkler system was noted in this building. Fire suppression systems are beyond the scope of this inspection. Inquire with the seller for any additional information; are there any required or recommended maintenance schedules?

Notes

  • GC-2 General Comments:

    The report has been procured by the seller and is provided for informational and disclosure purposes only. It is not intended to constituent a warranty, either expressed or implied about the condition of the property.

  • DPB3-1 Decks, Porches and Balconies:

    Siding to concrete contact was noted between the porch and the siding. This is a condition conducive to wood destroying organisms as it can trap moisture against the house. This is a common installation that should employ a vapor barrier between the concrete and the wood. No rot or damage was noted at the time of inspection and the area is well protected by a roof. As such, no repair appears needed at this time.

  • ES1-2 Electric Service:

    No permit stickers or paper work related to electrical work were found on the electric panel.

  • ES1-3 Electric Service:

    Please note that the main electric panel here is technically a sub-panel. This was inspected and seems to be wired correctly as a sub-panel.

  • K-2 Kitchen:

    No air gap noted for the dishwasher waste line but they did run a high loop. This is not done to WA state standards, but is generally satisfactory and many jurisdictions in the state allow for simply a "high loop" installation.

  • A-1 Attic:

    Note that this house has a vaulted ceiling configuration - there is no attic space and no access to inspect roof framing, thermal barriers or fans exhaust ductwork in the vaulted parts of the house.

📃 The Complete Inspection Report

General Comments

Building Characteristics, Conditions and Limitations

Style of Home: Town home

Type of Building : Single Family (3-story)

Approximate Square Footage: 1385

Approximate Year of Original Construction: 2007

Attending the Inspection: Listing Agent

Occupancy: Unoccupied, but staged with furniture

Animals Present: No

Weather during the inspection: Clear

Approximate temperature during the inspection: Below 45[F]

Ground/Soil surface conditions: Damp

For the Purposes of This Report, the Front Door Faces: North

(GC-2) Note:

The report has been procured by the seller and is provided for informational and disclosure purposes only. It is not intended to constituent a warranty, either expressed or implied about the condition of the property.

This house was vacant / unoccupied at the time of inspection. Vacant and unoccupied houses present unique challenges for home inspection, especially the piping and wiring systems which have not be subject to regular use prior to the inspection. While these systems can be tested during inspection, this one-time test is different than regular use and it is difficult to know how these systems will respond to regular use after the inspection. For example, septic systems may initially function and then fail under regular daily use. Plumbing traps may operate with no signs of leaks and then let go when being actively used for a few days. Shower pans may only leak when someone is standing in the shower and taking a shower. Seals for plumbing fixtures can dry up and leak when not is use. Sewer lines with roots may allow water flow, but then fail when waste and tissue are flushed; it can take a few days for that to backup. Please understand we are trying our best to look for clues of past or existing problems to paint a realistic best-guess as to the reliability of these systems during inspection.

Grounds

General Grounds Photos


Drainage and Site

Clearance to Grade: Standard

Downspout Discharge: Below grade

Site Description: Flat

Driveways/Walkways/Flatwork

Driveway: Concrete, Asphalt

Walkways: Concrete

Patios: Concrete

Window and Stairwells

None Noted

Grounds, Trees and Vegetation

Trees/Vegetation too near building: No

Retaining Walls

Retaining Wall Material: Block

Exterior Stairs

Exterior Stairs: None noted

Fences

Exterior Fencing: Present

The property has a fencing system in place. Inspection and evaluation of fencing is beyond the scope of a home inspection. If the fencing system is important for your use of this property, I recommended a self-examination to see how it will meet your needs. I may make cursory comments about fencing as a courtesy.

Outbuildings, Trellises, Storage Sheds, Barns

None noted

Roof, Chimney and Gutters

Roof Materials

Method of Roof Inspection: Viewed with binoculars

Roof Style: Gable

Flashings: Present and Visually Standard

Roof flashings are used to keep a roofing system waterproof where the roofing material starts, stops, changes direction or is penetrated. During inspection, we look for standard flashing techniques that could be considered normal or standard in our region. Damaged, incomplete or non-standard flashings can be a sign of an older or less reliable roofing system and may require repair. Any non-standard flashings noted during inspection will be reported on below if found.

Roof Covering Materials: Three-tab composition shingle

Approximate Age of Roof Covering: Unknown

Overlay Roof: No

(RCG-1) Recommended Maintenance:

Moss build-up was noted on the roof. This is bad for the roof covering as it can trap moisture on the roof and can inhibit drainage off the roof. Moss removal is recommended. Products such as Tide are not recommended as the bleach in these products can deteriorate the shingles. Pressure washers should not be used to clean the moss as they can damage the shingles unless the moss has been killed prior to washing. Only low pressure should be used to clean the roof of moss and chemicals should be used to kill the moss prior to removal. One product people use to kill the moss is baking soda. Hire a professional roof cleaning service to clean and service this roof to ensure proper control of roof runoff and proper drainage off the roof.

Chimneys

None noted

Skylights

Insulated curb style

(RCG-2) Repair:

The skylights have not been properly secured to the curbs. This could allow water entry and even blow-off during heavy winds. Have this repaired by a qualified contractor to ensure the skylights are well sealed and screwed down.

Gutters and Downspouts

Gutter and Downspout Materials: Metal

(RCG-3) Recommended Maintenance:

The gutters are clogged with organic debris and require cleaning to ensure proper control of roof runoff. Clean the gutters and ensure they are unobstructed, leak free and properly sloped to drain. This is routine house maintenance; I would expect the need to clean gutters and downspouts regularly.

Exterior Siding, Doors and Windows

Exterior Elevations


Siding and Trim

Trim Material: Wood

Siding Material: Fiber-cement, Cedar shingles

Manufacturers of fiber cement siding have done a poor job helping inspectors and consumers distinguish their products after installation; these products have few if any distinguishing characteristics. This report will site James Hardie manufacturers installation requirements for reference because they are the most common manufacturer of fiber cement siding and the various manufactures seem to share similar installation guidelines. Here is a link to the HZ-10 Best Practices Guide. However, reference of these guidelines in this report does not ensure that the fiber cement siding here is a James Hardie product.

(ESDW-2) Repair:

Localized rot repairs are needed to the exterior window trim on the South side living room and bedroom and as located. Hire a licensed general contractor to further evaluate and repair the exterior window trim system. Repair and replace all damaged and decaying exterior wood as needed. Please note that this condition can indicate additional concealed damage that is not visible to inspection.

Exterior Vent and Exhaust Terminations

Present

Eaves

Open rafters

Exterior Doors

Solid core, Glass panel doors

Exterior Window Frames

Vinyl

Decks, Porches and Balconies

Wood Decks Porches and Balconies

None noted

Structure: Concrete

Ledger Board: Not applicable

Guardrail: None needed

Decking Material: N/A

Posts, Beams and Footings: N/A

Concrete Decks, Stoops, Landings and Porches

Concrete Structure: Present, Concrete to Siding Contact - Not Ideal - Roof Overhang Noted

(DPB3-1) Note:

Siding to concrete contact was noted between the porch and the siding. This is a condition conducive to wood destroying organisms as it can trap moisture against the house. This is a common installation that should employ a vapor barrier between the concrete and the wood. No rot or damage was noted at the time of inspection and the area is well protected by a roof. As such, no repair appears needed at this time.

Water-Resistant Decks and Balconies

Water Proof Surfaces: None Noted

Fuel Storage and Distribution

Oil Storage

None noted

Propane Storage

None noted

Gas Meter

Present

Gas Shutoff Location: East side of structure

Gas Pipe Materials: Steel pipe


Gas, Propane and Oil Piping

Gas Piping Materials Noted: Steel

Garage

Garage General

Garage Type: Attached

(G4-1) Repair:

An unprotected opening was found in the garage wall and ceiling finishes. This should be repaired to complete the fire separation between the house and the garage. Large holes should be repaired with the proper sheetrock materials. Small holes and openings should be sealed with mud or high temperature of "fire stop" caulking. Openings with doors should employ listed fire-rated doors.

Garage Doors and Automatic Openers

Overhead Garage Door Type: Metal

Automatic Garage Opener: Present

Garage Occupant Door: Solid Wood

Garage Floor

Garage Slab: Concrete

Garage Stairs

Garage Stairs: None noted

Electric Service

Electrical System Safety Overview


Electric Service Permits Found

(ES1-2) Note:

No permit stickers or paper work related to electrical work were found on the electric panel.

Electric Service Voltage

Service Voltage: 120/240

Electric Service

Service Entrance: Below Ground

Meter Base Amperage: 100

Electric Service Equipment

Service Entrance (SE) conductor Size: Aluminum, #2, 100 amps

Main Panel Amperage: 100 amps

Electric Service Amperage: 100 amps

Main Electric Panel Location: Garage

Panel Manufacturer: Siemens

(ES1-3) Note:

Please note that the main electric panel here is technically a sub-panel. This was inspected and seems to be wired correctly as a sub-panel.

Electrical Grounding System

Present - Could Not Confirm

During a home or property inspection, every effort is made to inspect the visible components of the electrical system grounding. The grounding system is critical for safely discharging electrical surges, especially in the case of lightning strikes. There is no way in the context of a home inspection to verify the "effectiveness" of the grounding system as much of the system is not visible and there are not practical tests one can perform in the way we can test a furnace or a plumbing fixture. However, there are many things that can lead me to recommend further evaluation of the grounding system by a licensed electrical contractor and they will be documented in the observations below if discovered.

Electrical Bonding System

Bonding Noted on Water Pipes

Bonding connections were noted on the water pipes.

Electric Distribution and Finish Wiring

Branch Wiring

Wire Material: Copper, Multi-strand Aluminum

Wiring Method: Non-metallic sheathed cable


Receptacles and Fixtures

Inspection Method: Representative Testing

A representative number of receptacles and switches were tested during inspection. Any defects found during inspection are noted in this report. Only visible and accessible receptacles and switches were tested during inspection and personal items and furnishings are not moved to access any receptacles or fixtures.

Electric Receptacles: Three wire receptacles

(EDFW-2) Repair:

The loose electric receptacle housing on the South exterior should be secured and sealed. Securing loose receptacles can often be done by just tightening some set screws between the receptacle and the junction box, though sometimes it can get more complex if the box itself is loose. Repair as needed. Replace the damaged GFCI receptacle at the northwest exterior corner near the front entry door.

Smoke and Carbon Monoxide Alarm Systems

CO Alarms: Present

The installation of carbon monoxide alarms is recommended for all homes that have fuel burning appliances such as gas or oil furnaces, gas water heaters, gas ovens and cook-tops, gas fireplaces and wood stoves. In addition, Washington State law (WAC 51-51-0315) now requires UL 2034 approved carbon monoxide alarms in ALL homes and condominiums being sold in Washington State. The location should be: at least one alarm outside of all sleeping areas and one on each floor of the house. Best practices are to have these alarms hardwired with a battery back-up - though requirements are for the installation to meet manufacturer's specifications. Carbon monoxide is a colorless, odorless gas that can cause sickness, nausea and even death. Alarms have a useful service life of roughly 6 years, so changing them more frequently than smoke alarms is recommended.

Smoke Alarms: Present

For reliability, fire marshals recommended updating smoke alarms every 10 years and changing batteries bi-annually. The latest data indicate that we should be using photoelectric technology in our smoke alarms for improved fire detection and to reduce problems with false alarms which can lead to disabling of this important safety system. Unfortunately, the alarms have to be removed to determine if they are photo-electric or ionization types. It is surprisingly complex to accurately test a smoke alarm system and determine the reliability, age, and type of sensor technology used, especially as many homes can have half a dozen or more alarms throughout the house. A complete evaluation of smoke alarms is beyond the scope of this inspection. For optimal fire safety, I recommend taking control of these important safety devices and learning about how to service and maintain your smoke alarm system to keep the building occupants safe. For more information, please read this link. For more information, please read this link.

Heating, Cooling, Fireplaces and Ventilation

Heating System

Energy Source: Natural gas

Heating Method: Water heater hot water system

Manufacturer: Bradford White

Data Plate: Shown Here

This shows the data plate from the hot water tank. 📸

Capacity: Unknown

Age: 2007

Last Service Record: Unknown

(HCFV-1) Recommended Maintenance:

Annual servicing is recommended for safe and reliable performance from this hot water heating system. Hire a licensed heating contractor to service and further evaluate the systems.

Air Filters

Filtration Systems: None

Heating and Cooling Distribution Systems

Heat Source in Each Room: Present

Distribution Method: Radiators

Mechanical Ventilation Systems

Bath Fan Ducting: Ducted to exterior

Kitchen Fan Ducting: Ducted to exterior

Whole House Fans, Ventilation and HRVs: Landry / House Fan Timer

Gas Fireplaces

Fireplace Types: Direct vent gas log fireplace

Gas Shut off Noted: Yes

This shows the gas fireplace was off at the time of the inspection, no testing was performed. It is excluded from this report.

Solid Fuel Fireplaces

Fireplace Types: No wood burning fireplaces or appliances noted

Plumbing

Water Meter

Not Found - Inquire With Seller

Water Service Supply

Pipe Material: Copper

Water Supply: Public water

Water Pressure: 50 PSI

Pressure Reducing Valve: Present

This house has a pressure reducing valve to control the water pressure.

Main Water Shut-off Location: Beside the water heater

Distribution Pipe

Pipe Insulation: Not visible

Supply Pipe Materials: Copper

Functional Flow: Average

Circulation Pump: Present

Waste Pipe and Discharge

Discharge Type: Public Sewer - Seller

Waste and Vent Pipe Materials: ABS plastic

Location of Sewer Cleanout: Garage, Bathroom

This shows the location of the sewer cleanout found during inspection - garage, bathroom. 📸

Water Heater

System Type: Tank

Manufacturer: A.O.Smith

Data Plate: Shown Here

This shows the data plate for this water heater.

Size: 48

Age: 2007

Energy Source: Gas

Straps : Present

Pad: None Needed

Drain Pan: Not Needed

Expansion Tank: Present

Temperature Pressure Relief Value: Present - Not Tested

A temperature and pressure relief valve (TPRV) is required on all water heaters to discharge any excessive pressure within the tank. A discharge pipe should be attached to the valve and directed to a safe location away from body contact. Newer installations must be directed to the building exterior or to an approved indoor drain receptor. Most manufacturers suggest that homeowners test these valves at least once a year by lifting the lever to ensure the valve discharges properly and also recommend inspection of these safety devices every three years. The picture here shows a typical TPRV. They may also be found on the side of the heater on some models. I do not test these valves due to the possibility that they may leak after testing. A leaking or inoperative TPRV should be replaced immediately by a licensed plumber.

Due to inconsistencies between both UPC and IPC Plumbing codes, and water heater manufacturer's instructions, and TPRV manufacturer instructions, it is not actually possible to install the drain from the Water Heater TPRV "properly." There are conflicts with distance of termination to the floor/ground, types of pipes approved, and diameters of pipes approved. Additional confusion is added when jurisdictional inspectors approve installations/materials specifically not allowed by both codes and manufacturers. My recommendations will vary depending on the installation and will be included in the applicable narratives below.

Most codes defer to manufacturer instructions and I favor those recommendations. The yellow tag on the valve states clearly the termination should be 6" above the floor which is more consistent with the UPC code requirements.

(P2-1) Monitor:

This water heater is likely close to the end of its useful service life. The average life of a water heater is statistically 8-12 years though in practice, they can vary widely between 8-20 years depending on water quality and maintenance schedule such as frequency of flushing the tank and replacing sacrificial anodes. Budget to replace this water heater at any time. Water was hot at the time of inspection.

Water Temperature

Water Temperature Measured During Inspection: 118 Degrees F

Exterior Hose Bibs

Operating

Additional Plumbing

Sump Pumps and Drains

Floor Drain: None noted

Sump Pumps: None noted

Fire Suppression

(AP-1) Due Diligence:

An interior fire sprinkler system was noted in this building. Fire suppression systems are beyond the scope of this inspection. Inquire with the seller for any additional information; are there any required or recommended maintenance schedules?

Interior

General Interior Photos

Floors and Floor Materials

Floor Materials: Carpet, Wood, Tile

Floor Settlement: None noted

Walls, Ceilings, Trim, Hallways and Closets

Wall and Ceiling Materials: Drywall

Wall Insulation and Air Bypass

Wall Insulation: Not Visible

Stairs and Railings

Standard

Interior Doors

Interior Doors: Solid and Hollow Core

Windows

Window Glazing: Double pane

Interior Window Frame: Vinyl

Window Styles: Sliding, Single hung

Window Brands Noted: Unknown

Kitchen

General Kitchen Photos

Sinks and Faucets

Tested

Cabinets and Countertops

Countertop Material: Natural Stone

Cabinet Material: Wood

Disposers

Disposer: Operated

Dishwasher

Dishwasher: Operated

Dishwasher Air Gap: Just a high loop

(K-2) Note:

No air gap noted for the dishwasher waste line but they did run a high loop. This is not done to WA state standards, but is generally satisfactory and many jurisdictions in the state allow for simply a "high loop" installation.

Ventilation Method

Fan Ducted to Exterior

Ranges, Ovens and Cooktops

Range/ Oven /Cook-tops: Gas and electric

Refrigerators

Refrigerator: Operating

General Kitchen Condition

Standard

Laundry Facilities

Washer

Not tested

Dryer

Not tested

Laundry Ventilation

Type: Laundry fan

Main Bathroom

General Bathroom Photos


Sinks and Cabinets

Tested

Toilet

Tested

Bathtub / Shower

Tested

Bathroom Ventilation

Type: Bath fan

General Bath Condition

Standard

Attic

Attic Access

No access. Vaulted Ceiling Everywhere

(A-1) Note:

Note that this house has a vaulted ceiling configuration - there is no attic space and no access to inspect roof framing, thermal barriers or fans exhaust ductwork in the vaulted parts of the house.

Roof Framing and Sheathing

Rafters: Not visible

Sheathing: Not visible

Attic Insulation

Insulation Type: Not visible, No access - vaulted ceiling

Approximate Insulation R-Value on Attic Floor: Not visible

Approximate Insulation R-Value on Attic Ceiling: Not visible - vaulted ceiling

Approximate Insulation R-Value on Attic Walls: Not visible

Attic and Roof Cavity Ventilation

Attic Ventilation Method: No access. Vaulted ceiling

Structure and Basement

Foundation

% of Foundation Not Visible: 90%

Evidence of Seismic Protection: Not visible

Building Configuration: Slab on grade

Foundation Description: Poured concrete

Floor, Wall and Ceiling Framing

Wall Framing: Not visible

Wall Sheathing: Not visible

Floor Framing: Not visible

Sub-Floor Material: Not visible

Ceiling Framing: Not visible

Basement

None

Basement Moisture

Not applicable

Rodents, Pests and Wood Destroying Organisms

Rodents

None noted

Other Pests

None noted

Wood Destroying Organisms

Visible Evidence of Active Wood Destroying Insects: None noted

Visible Evidence of Inactive Wood Destroying Insects: None noted

Visible Evidence of Damage from Wood Destroying Insects: None noted

Visible Evidence of Active Wood Decay and Fungi: Present, See WDO Comments in this report

Visible Evidence of Conditions Conducive to Wood Destroying Organisms: Present, See WDO observations in this report

Checking Out Procedure

Check Out List

Oven:Off

Heating and Cooling:Restored to Pre-inspection temperatures

Appliances:Off / finishing cycle