Reinspection Report
How to Read This Report
See the video link above. For the best experience, read this report online in its HTML format on a desktop computer as mobile can be tougher to digest this much information. This will allow you to easily expand sections, click blue links for additional information, and view embedded videos that provide important context beyond text and photos. Share the report by copying the web link from your browser, or print/save as a PDF using the buttons at the top, though printed copies greatly limit information. You can also create a custom Request List to generate a PDF of selected items to avoid sharing the entire report if needed.
This report is organized by chapters and sections, with general information in black text and any deficiencies or observations highlighted in colored boxes. Sections without observations were inspected and found to be in satisfactory/serviceable condition at the time of inspection.
The Scope of a Reinspection
A reinspection is not a guarantee or warranty for the work performed. This was a visual inspection to determine if agreed repairs or modifications appeared visibly complete at the time of this reinspection. This report is a copy of the original inspection and any Items that were asked to be reinspected have been identified as either Complete, Partly Complete, or Incomplete and may also include reinspection notes, new media, and possibly other observations that you would want to be aware of that may have changed since the original inspection.
Purchasing a Property Involves Risk
Buying a property involves risk and these inspections aim to reduce those risks by providing a professional opinion on its overall condition. However, it's crucial to understand the limitations of these inspections.
Limitations
Home inspections are not warranties, guarantees, or insurance policies. They are limited visual inspections and cannot eliminate all risks inherent in property purchases. Inspections are non-destructive, meaning they involve visually examining accessible areas without dismantling or damaging the structure. Concealed areas and systems that cannot be tested without risk of damage are not covered.
This is Not for Code Compliance
This inspection did not assess code compliance. Building codes constantly evolve, and all buildings fall out of code compliance shortly after they are built, as the codes continually change. There are generally no requirements to bring older homes into compliance unless renovations are being done and permits are needed for the work.
This is Just Our Opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are opinions of the professional inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome and encouraged to seek opinions from other professionals.
Observation Labels
All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
Summary
Reinspection Items
- GI-4 General Information - Building Characteristics, Conditions and Limitations:
Reinspection Disclaimer and Documents
This was a limited re-inspection of only the specific building components or conditions listed below. It was not a full building inspection under ASHI Standards of Practice. No other items were evaluated. Only items that were accessible and visible at the time of this re-inspection were reviewed. Conditions may have changed since the original inspection, and any areas not re-inspected remain outside the scope of this visit.
Verification of repairs is often limited. Many repair details may be concealed behind finishes, coverings, or assemblies (such as wall materials, roofing layers, or flashings), making it difficult or impossible to confirm the quality or completeness of the work. In these cases, we rely on the visible portions of the repair and recommend obtaining repair documentation, invoices, and warranties from the qualified contractor who performed the work. No warranty, guarantee, or certification of repair quality is provided.
- Attached PDF/Media outlines what was inspected during this re-inspection.
Incomplete Items
- A-4 Attic - Roof Framing and Sheathing:
Staining/Mold-Like Substances Noted - Attic Ventilation Poor
Localized discoloration and mold-like substances were noted on portions of the attic roof sheathing or framing. This appeared older and inactive at the time of inspection, and the materials tested dry; however, the attic ventilation was poor. This type of staining is commonly associated with seasonal condensation from elevated attic humidity, especially during colder weather conditions. Ventilated attic spaces are generally considered exterior spaces or unconditioned environments, and mold-like substances in these areas are often isolated from the indoor living environment, which can make remediation subjective. No visible evidence suggested active moisture intrusion at the time of inspection, though seasonal conditions may still allow condensation to occur in the winter and contribute to continued staining, deterioration or mold growth over time.
Recommendation: Have a qualified contractor increase attic ventilation (see ventilation section) and monitor for worsening. If additional evaluation or testing for mold-like substances is desired, a licensed mold remediation specialist may be consulted. Small areas of mold can be easily cleaned with hydrogen peroxide.
Reinspected 6/1/2099: the mold like substance in the Attic still looked exactly like it did at the original inspection and it is not appear that anything has been done with this.
- EDF-4 Electric Distribution & Fixtures - Receptacles & GFCI's:
GFCI Was Tripped And Would Not Reset
GFCI receptacles were found in the tripped position and would not reset. It is possible that because GFCI's will not reset without power, that they were wired in series with another hidden or unlocated GFCI that was tripped. The other possibility is that these are defective. Have these GFCI receptacles reviewed by a qualified electrician for safety.
Locations of affected GFCI's include:
- Exterior Back
Reinspected 6/1/2099: the old receptacle was still inoperative and has not been repaired.
- EDF-8 Electric Distribution & Fixtures - Smoke and Carbon Monoxide Alarm Systems:
No Carbon Monoxide (CO) Alarms Observed
The installation of carbon monoxide alarms is recommended for all homes that have fuel burning appliances and/or an attached garage. No functioning installed alarms were observed in the dwelling during the inspection. In addition, Colorado State law (House Bill 09-1091) now requires approved carbon monoxide alarms in ALL homes being sold, when interior renovations that require a permit are made and/or when fuel burning appliances are replaced. The location should be: at least one alarm outside of all sleeping areas, within 15 feet, and one on each floor of the home. It is also recommended they be installed in rooms with fireplaces, wood stoves, gas heaters, or any fuel burning appliance. Best practice is to have these alarms hardwired with a battery back-up - though requirements are for the installation to meet the manufacturer's specifications. Carbon monoxide is a colorless, odorless gas that can cause sickness, nausea, and even death. Alarms have a useful service life of roughly 6-10 years, so changing them more frequently than smoke alarms is recommended.
Reinspected 6/1/2099: no carbon monoxide alarms were found inside the building
Partly Completed Items
- RCG-3 Roof, Chimney and Gutters - Flashings and Penetrations:
Roof Edge Flashing Missing
Edge flashing was not present at all locations which may not have been required when the roof was installed. Its job is to prevent water from running down the fascia and behind the gutters (if present). Installing edge flashing at all locations will help extend the life of the fascia and roof sheathing at the edges.
Recommendation: This should be added by the roofing company when the new roof is installed.
- Soffit and fascia damage was noted as a result of this and should be repaired by a qualified contractor.
Reinspected 6/1/2099: the front fascia board has been replaced, but it is not been caulked or painted and the gutter was still laying on the ground.
Completed Items
- EDF-5 Electric Distribution & Fixtures - Receptacles & GFCI's:
Inoperative Receptacles Noted
Inoperative electric receptacles were noted. These may be on a switched or GFCI protected circuit, but no switch or tripped GFCI was found during the inspection.
Recommendation: Have inoperative electric receptacles further evaluated and repaired by a licensed electrician as needed.
Locations noted include:
- Dryer receptacle did not have power yet the breaker was on.
Reinspected 6/1/2099: repairs appear to be complete and the dryer receptacle had power and appear to be correctly wired
- EDF-9 Electric Distribution & Fixtures - Smoke and Carbon Monoxide Alarm Systems:
Smoke Alarm Repairs are Needed
Repairs or updates are needed for the smoke alarms. Modern standards require them inside each bedroom and on every level of the home, including the basement. On levels without bedrooms, install alarms in the living room (or den or family room) or near the stairway to the upper level, or in both locations. They should be on the ceiling at least 4 inches from the wall but may be on wall, no lower than 12 inches from the ceiling. Smoke alarms should be replaced every 10 years per the manufacturers instructions.
Specific observations noted include:
- Alarms were not present in all of the bedrooms.
Recommendation: Have a qualified person repair the smoke alarms so they conform to modern standards for safety.
Reinspected 6/1/2099: a new smoke alarm has been added to the bedroom and this repair has been completed
- P-5 Plumbing - Distribution Piping:
Leaking Supply Piping Observed
An active leak was noted at the supply piping. Have this further evaluated and repaired by a licensed plumber to ensure reliable performance.
- This was a small drip, but repairs should be mad as soon as possible
Reinspected 6/1/2099: a new fitting has been added in addition to a new water shut-off valve and pressure reducing valve. This repair was completed
- HCF-9 Heating, Cooling, & Fireplaces/Stoves - Heat and Cooling Distribution System(s):
Deteriorated Evaporative Cooler Ductwork
Sections of the evaporative cooler ductwork were deteriorated. Evaporative coolers introduce humid air into the duct system during operation, and over time this commonly causes corrosion, rusting, or deterioration of galvanized sheet metal ducting. Deteriorated ductwork may reduce airflow performance and can eventually allow air leakage or failure of the duct system.
Recommendation: Have the affected ductwork further evaluated and repaired or replaced as needed by a qualified HVAC contractor.
Reinspected 6/1/2099: the holes in the duct work have been fixed and a new flex duct has been added to the drop. This repair was completed
- MV-1 Mechanical Ventilation - Mechanical Ventilation Systems:
Attic Termination - Relocated to Exterior
One of the duct(s) for the bathroom exhaust fan(s) terminated in the attic . Ultimately, it is best to vent these to the exterior to prevent mold growth and moisture damage. A qualified professional should review and repair as advised.
- This was likely contributing to the condensation issues noted in the attic.
Reinspected 6/1/2099: the bath fan has been vented to the exterior. This repair has been completed
- K-1 Kitchen - Sink(s):
Leaking Drain
The drain plumbing was leaking and requires immediate repair to prevent damage to the cabinet. This only leaks when the faucet is used. Hire a qualified plumber to repair.
Reinspected 6/1/2099: the kitchen sink did not leak anymore when tested. This repair was completed
Major Concerns
- RCG-2 Roof, Chimney and Gutters - Roof Covering(s):
Roof Replacement Recommended
The roof was done in a three tab composition shingle. The roof looks to be old and close to the end of its reliable service life. Roof replacement is recommended to ensure reliable roof performance. If this is a real estate transaction, the insurability of the roof should be verified.
Examples of observations noted include:
- missing shingles
- severely degraded shingles
Recommendation: Hire a qualified roofing contractor to further evaluate and replace this roof.
- If a second layer of shingles is added overtop, the first layer must be in good condition with no missing or damaged shingles as this acts as the underlayment for the new layer. Also, you should expect reduced shingle life with with two layers.
- FSD-2 Fuel Storage and Distribution - Fuel Piping:
Natural Gas Odor Noted at Time of Inspection
A natural gas odor was detected at the time of inspection. The presence of a gas odor is not a normal condition and may indicate a leak or failure within the fuel gas system, which can present a fire or explosion hazard.
- The source of the odor could not be pinpointed.
Recommendation: Contact the natural gas utility provider for immediate evaluation. The utility can determine whether the issue is related to the service equipment or piping and advise on any necessary corrective action.
Repairs
- G1-2 Grounds - Grading and Drainage:
Siding to Soil Contact Noted
Eliminate siding / soil contact at all areas to reduce the chances for deterioration and pest damage and repair any concealed damage as needed. Generally, a 6-inch clearance between soils and siding is recommended. This is often not realistic on older homes, but repairs should be made to achieve as much clearance as possible, and all direct soil contact should be eliminated. Maintaining this clearance is important not only to protect the siding, but also to help safeguard the underlying wall framing from moisture intrusion, rot, and wood-destroying pests. When creating this clearance, current standards recommend the grading adjacent to the building should be positively sloped at a 5% grade within 10 feet of the building.
See media for examples of locations:
- A-6 Attic - Attic Cavity Ventilation:
Non-Standard Roof Cavity Venting
The attic and roof cavity ventilation area looked to be inadequate. The goal of attic cavity ventilation is to keep it as close to ambient air temperature as possible. Adequate ventilation helps lower attic temperatures in the summer reducing cooling costs, prevents the build-up of moisture and condensation in the winter, and help extend the life of the roof system. As this building is made tighter, better insulated, and air-sealed for energy efficiency it is important to improve roof cavity ventilation as well.
- Not enough upper/exhaust ventilation was noted in this roof cavity section.
- No lower/intake soffit ventilation was noted in this roof cavity section.
- The mold-like substance noted on the roof framing/sheathing was likely a result of this poor ventilation causing condensation in the winter.
Recommendation: Consult with a qualified general contractor about adding roof ventilation as recommended.
For more information, please check out this crash course on attic cavity ventilation by Clicking Here
- EDF-1 Electric Distribution & Fixtures - Branch Wiring:
Open Electrical Splices
The open electrical splices should be further evaluated and repaired by a licensed electrical contractor. All wiring splices should be contained inside listed junction boxes. Open or "running" splices are a sign of amateur or incomplete electrical work and could indicate a need for additional repairs that are latent or concealed. Have this further evaluated and repaired as recommended by a licensed electrical contractor.
Locations noted include:
- Attic
- P-6 Plumbing - Exterior Hose Bibs:
Frost-Free Hose Bib Not Sloped to Drain
Hose bib(s) were not installed in a manner that will allow them to drain when shut off. These should be installed with a proper slope to prevent freezing during cold weather. Have a licensed plumber review and advise.
- HCF-8 Heating, Cooling, & Fireplaces/Stoves - Air Filter(s):
Missing Air Filter
Filter(s) is/are missing at the furnace. Suggest installing filters for improved indoor air quality and to keep the blower fan and duct system clean.
- CS-5 Crawl Space - Ventilation and Vapor Barrier:
Inadequate Crawl Space Ventilation - No Vapor Barrier
Crawlspace did not appear to be adequately ventilated for not having a vapor barrier laid over the soil. Proper ventilation prevents moisture buildup leading to mold growth. When no class 1 vapor barrier or radon mitigation system is present, adequate ventilation should be installed at 1sqft of opening to 150sqft of under floor space. If a class 1 vapor barrier is to be installed, that ratio can be reduced to 1sqft of opening to 1500sqft of under floor area. Mechanical exhaust fans on humidistats can also prevent the buildup of moisture with even less screened area. Full crawlspace encapsulation or a radon mitigation system would allow the wall venting to be removed and sealed up as moisture would no longer be an issue.
- No moisture issues were noted.
- Adding a sealed crawlspace liner over the soil and adding an exhaust fan on a humidistat (set to about 40%) would be the ideal repair here.
Recommendation: Suggest a building contractor specializing in crawlspace moisture control further evaluate.
A good read on the building science of crawlspaces can be found here: https://buildingscience.com/documents/insights/bsi-009-new-light-in-crawlspaces
- CS-6 Crawl Space - Moisture:
Damp Crawl Space
The crawlspace soil was excessively damp which was contributing to an elevated humidity level of approximately 60%. When the soil is too wet, it elevates humidity levels and can create moisture related issues such mold, deterioration, and an inviting habitat for wood destroying organisms. If any of these were present, they will be noted in the report. Humidity levels should be kept below 50% at all times to prevent these problems. A professional contractor specializing in basement/crawlspace moisture should identify the source of the water and mitigate the problem. Items such as vapor barriers, french drains/improved lot grading, gutter/downspout discharge improvements, sump pumps, and/or powered ventilation may need to be modified or installed to fully remedy the problem, protect the building, and ensure a clean dry crawlspace.
A good read on the building science of crawlspaces can be found here: https://buildingscience.com/documents/insights/bsi-009-new-light-in-crawlspaces
Due Diligence Items
- RCG-4 Roof, Chimney and Gutters - Flashings and Penetrations:
Appliance Exhaust Vent - Too Close to Wall or Roof
The exhaust B-vent was located too close to a nearby wall or roof. This can inhibit proper drafting and even present some safety issues or durability issues for the building's exterior. This vent should be
- 8-feet from an adjacent wall or 2-feet above the wall.
- 2-feet above anything within 10-feet.
- At least 8-feet from an operable window.
Recommendation: Have this further investigated and repaired as recommended by a qualified heating or plumbing contractor. This appears to have been like this for a long time and no issues were observed. While it still is technically not correct, corrections may not be necessary and a relocation could likely wait to be performed in the context of other repairs or upgrades.
- SS-3 Sewer Scope - Scope Findings:
Sewer Main Tap Not Inspected Due To Friction
The tap at the city sewer line or septic tank was not inspected because there was too much friction between the camera push rod and the pipe. The push rod will buckle and not advance the camera if a high amount of friction from too many turns, debris, or scale on the pipe is present. Suggest review by a licensed plumbing contractor or drain cleaning professional for a proper assessment of the tap. Other recommendations and or repairs may be necessary after the assessment.
- HCF-4 Heating, Cooling, & Fireplaces/Stoves - Heating System:
Appliance Fuel or Pilot Was Off - Not Operated
Fuel or pilot was off to this gas furnace at the time of inspection which rendered the unit inoperative, making this inspection a limited visual inspection only. These are not turned back on for safety reasons without written permission which was not obtained. Suggest verifying correct operation with the owner and/or having a HVAC contractor review it for possible maintenance and repairs as advised.
- I-1 Interior - Walls, Ceilings, Trim, and Closets:
Popcorn Ceilings May Contain Asbestos
The ceiling in some rooms contains popcorn texture. This product may contain asbestos as many of these products contained asbestos prior to 1978. After 1978, remaining stocks of material containing asbestos were sold and as the product was slowly phased out. Asbestos testing is beyond the scope of this inspection. The health risks posed by this substance are minimal unless the texture becomes friable or air borne. If you wish to remove the popcorn texture or have remodel plans that could involve cutting or removing this sheetrock, asbestos testing is recommended. Consult with an environmental lab for more information on asbestos testing. One safe option is always to drywall/sheetrock over this texture if you wish to have a different ceiling finish.
Future Projects/Repairs
- G1-3 Grounds - Grading and Drainage:
Poor Site Grading
The grade of the yard sloped toward the building. Standards recommend at least a quarter-inch / foot slope away from the building for 10ft if possible to prevent water from draining toward the building. Over time, negative grading, as this is often called, can lead to moisture and even structural problems with the building, especially when roof drainage discharges to this area. Have this repaired as feasible by a qualified contractor. Often, a swale can be used to create a low point away from the house into which water can be diverted safely away from and around the building.
See media for details and locations:
Recommended Maintenance
- E-1 Exterior - Siding and Trim:
Hardboard/Masonite - Localized Painting Needed
The hardboard/Masonite siding and trim on this building was in need of some localized painting, caulking, and repairs. This should be done soon as the paint is its only protection against deterioration and swelling from water absorption. This engineered wood material does not have a durable track record, requires routine caulking and painting, and when exposed, easily absorbs water causing swelling at the cut edges, at the top where water rests, and the bottoms where water droplets linger. A full, professional paint job would be ideal, but localized painting will put the need for a full paint job off for a few years.
- Small sections may need to be replaced as they may have deteriorated too much to hold new paint well.
Recommendation: Have a professional painting/building contractor implement localized painting as needed.
- RCG-5 Roof, Chimney and Gutters - Gutters and Downspouts:
Gutter Cleaning Recommended
The gutters had excess debris in them and should be cleaned to ensure proper control of roof runoff. Ensure they are unobstructed, leak-free and properly sloped to drain as part of routine maintenance. Ensure the downspouts are clear as well as these can be clogged causing the gutters to fill which may cause damage to them or the building.
Improve Or Upgrade Items
- ES-8 Electric Service - Sub Panel:
AFCI Protection was Inconsistent with Modern Standards
AFCI (Arc Fault Circuit Interrupter) breakers, which were introduced around 2002, are designed to detect dangerous electrical arcing caused by damaged, loose, or aging wiring that standard breakers can not sense. These arcing conditions can generate high heat without drawing enough current to trip a conventional breaker, which increases fire risk🔥. Modern electrical safety standards now call for AFCI protection on most residential circuits, so it is common for older homes to fall short of these standards. While upgrades are not required for existing homes, improving AFCI protection is considered a meaningful safety improvement, especially when other electrical work is being performed.
- EDF-6 Electric Distribution & Fixtures - Receptacles & GFCI's:
GFCI Protection Improvements Recommended
Since the 1970s, requirements for GFCI (Ground Fault Circuit Interruption) protection have changed, and locations requiring GFCI protection seem to get added with every code cycle. It is common for older residential buildings to have some or even many electric receptacles that do not meet modern safety standards. GFCIs have proven successful at reducing electrocutions, and it seems likely that someday, every circuit, receptacle, and appliance in the building will require GFCI protection. The first chart below shows how successful GFCIs have been at reducing risks from electrocution. The second illustration shows where GFCI protection is required as of the 2020 NEC. In terms of safety, its recommended to bring GFCI protection up to modern safety standards.
GFCI protection was inconsistent with modern minimum standards for safety in the following locations:
- Laundry Area
- Kitchen
- WH-5 Water Heater - Unit Components:
No Drain Pan for Water Heater
No drain pan has been installed below the water heater here. A drain pan is recommended under water heaters that are located in finished spaces or where a leak could damage finishes. Where a pan does not already exist, the tricky part is providing a drain to the outside or plumbing system. A pan without a drain is often of limited benefit / protection. For improved protection from accidental water heater leaks, and where a drain is difficult to install, consider a pan with a moisture alarm.
- CS-3 Crawl Space - Foundation/Floor Insulation:
Improper Vapor Barrier Orientation at Crawl Space Floor Insulation
Fiberglass insulation was observed installed in the floor system above the crawl space with the vapor retarder facing the crawl space (cold side). Vapor retarders are intended to face the warm-in-winter side of the assembly; when installed on the cold side, they can trap moisture against the insulation and framing. This condition can reduce insulation performance and contribute to moisture accumulation, mold growth, and long-term deterioration of the floor structure.
Recommendation: Consider consulting a qualified building professional to evaluate improvements to the crawl space insulation and moisture control strategy, which may include removing or correcting the vapor retarder and considering alternative approaches consistent with modern building-science practices.
Minor Repairs
- G1-4 Grounds - Grading and Drainage:
Downspout Repairs Recommended
Downspout was missing and should be repaired by a qualified person. These should be in good condition, properly secured, and long enough (typically 3-5 ft) to ensure proper drainage away from the foundation. Water that pools around foundations and flatwork can lead to water intrusion, settlement, heaving, cracks, and other issues over time. Fortunately, these issues can be easily avoided when the drainage system is properly designed and in good working order.
See media for details and locations:
- P-7 Plumbing - Exterior Hose Bibs:
Handle Repair Needed
Replace or repair the damaged handle to the hose bib.
See media for locations and details:
- WH-1 Water Heater - Hot Water Temperature:
Water Too Hot
The water temperature was too hot and should be adjusted between 115 and 130 degrees F for safety as scalding times exponentially decrease with higher water temperatures. Children and elderly people with "thin" skin are much more susceptible to 2nd and 3rd degree burns from excessively hot water (see chart).
Items for Monitoring
- G1-5 Grounds - Grading and Drainage:
Underground Drains Noted
Underground downspout drainage system was observed. These are not within the scope of a general inspection and a functional water flow test was not performed. Suggest these be scoped with a camera to determine the condition or a functional water flow test be performed to ensure they flow well and do not back up under heavy rain. Underground drains that back up or leak can concentrate the water against/near the building and will increase the likelihood of water related issues such as foundation and slab movement, water intrusion, and deterioration of building materials. Monitoring these under heavy rains should be made part of your annual routine maintenance to prevent issues.
- E-2 Exterior - Eaves:
Minimal or No Eaves Noted.
This building was designed with no or very minimal eaves/overhangs. The eaves act like an umbrella for the building, by keeping most of the rainwater off of the siding, windows, and doors. Ensuring gutters are present at all drip edges and keeping them clean and draining well is important for a building with this design. Keep an eye out for gutter leaks as they can run down the siding and over time cause water damage. Suggest more routine monitoring of the exterior and expect the need for more vigilant maintenance for exposed sections of the building.
- SS-4 Sewer Scope - Scope Findings:
Minor Sag/Belly
The sag(s) seen during the sewer scope inspection were MINOR and were located approximately 85 feet from the access point. Minor sags may cause a buildup of debris but not usually enough to cause a negative effect on the sewer. A sag is considered minor if the water fills less than 25 percent of the pipe diameter. Corrective action for a minor sag is generally not required. Please note, that when the camera goes underwater, it makes visual inspection of the pipe at these areas difficult or impossible.
Recommendation: Re-scoping within the next one to three years is advisable to detect any worsening of the sag and accumulation of debris.
- HCF-5 Heating, Cooling, & Fireplaces/Stoves - Heating System:
Older Gas Forced Air Furnace
The gas forced air furnace may be close to the end of its useful design life based on the average life span of these units being 15-25 years. While some can and do last longer, funds should be reserved to replace this furnace at any time. The risk of running a gas forced air furnace past its useful design life is that the furnace could continue to operate with a cracked heat exchanger. This is a safety hazard that may allow products of combustion to enter the supply air to the home. Furnace heat exchangers are not visible to inspection without expensive diagnostics, so it is difficult to know when the furnace could be posing a safety hazard to the occupants. Older furnaces like this are also less reliable and subject to the need for constant repairs. It can be more cost effective to simply replace these furnaces on a 20 years schedule. Suggest having this furnace serviced by a HVAC professional annually until replaced.
Efficiency Items
- E-3 Exterior - Exterior Doors:
Lost Seals in Door Glazing
One of the insulated glass units (IGUs) in the exterior door glazing had failed seals. Failed insulated glass units commonly show condensation, fogging, residue, or corrosion between the panes of glass, which cannot be cleaned from the interior or exterior surfaces. This condition primarily affects the appearance and energy efficiency of the glazing. Replacement of the affected glass units by a qualified glass contractor may be desired to improve clarity and thermal performance. Please note that failed seals can sometimes be difficult to identify, as condensation between panes may vary depending on temperature, humidity, and seasonal conditions.
See media for locations:
- A-3 Attic - Access & Type:
Insulate and Air-Seal Attic Access
Recommend the attic access hatch pictured here have insulation and weather stripping installed to prevent heating and cooling losses to the attic since it was located within the building envelope.
- Glued, rigid foam board is recommended for these as fiberglass batts tend to fall off or not be reinstalled correctly.
Home Owners Association Items
- G1-6 Grounds - Irrigation:
Irrigation System Noted - HOA Responsibility?
An exterior irrigation system was noted. Sprinkler and irrigation systems are beyond the scope of this inspection, but based on our experience, this one is likely maintained and managed by the HOA (Home Owners Association). Suggest inquiring with the association for further information about responsibilities.
Limitations
- CS-4 Crawl Space - Foundation/Floor Insulation:
Floor Insulation Limits View of Components
The floor framing system was insulated which makes inspecting it difficult and hinders the detection of defects without out removal of the insulation. This is considered a limited review of this area as inspectors do not remove or damage insulation during a general home inspection.
✅Complete Report
Grounds
Elevation Photos
Grading and Drainage
Driveways/Walkways/Flatwork
Fencing
Trees and Vegetation
Irrigation
Exterior Stairs and Guardrails
Attic
Access & Type
Roof Framing and Sheathing
Fire Separation and Blocking
Attic Insulation
Attic Cavity Ventilation
Electric Service
Service Entrance
Main Electrical Panel
Electrical Grounding System
Electrical Bonding System
Sub Panel
Electric Distribution & Fixtures
Branch Wiring
Receptacles & GFCI's
Lighting
Ceiling Fans
Smoke and Carbon Monoxide Alarm Systems
Low Voltage Wiring
Plumbing
Water Supply
Distribution Piping
Drain Waste & Vent
Exterior Hose Bibs
Floor Drains, Sump & Ejector Pumps
Heating, Cooling, & Fireplaces/Stoves
Heating System
Evaporative Cooler
Exhaust Vents/Flues
Air Filter(s)
Heat and Cooling Distribution System(s)
General Information
Building Characteristics, Conditions and Limitations
Type of Inspection: Re-inspection
Primary Building Type: Townhome
Townhouse Inspection: This inspection consists predominantly of an interior viewing of the inspected unit and a partial visual inspection of other areas of the perimeter of the structure - the roof, the grounds and the common areas that are available and open for observation. Only this unit was open to inspection, so there was no attention given to any adjacent units or other units in the structure. Regarding zero lot line townhouse construction, responsibilities for maintenance and repairs falls substantially on the individual owner, although there are sections of the structure that will need cooperative efforts for repair, such as roofs, common exterior walls, common exterior grounds etc. For specific responsibilities though, gaining information from the condominium association's agreement is recommended to determine the actual responsibilities of the new occupant and how it may be shared with the group. It is highly recommended that the association’s building records and minutes be examined to determine whether there have been issues in the past at other units that might indicate a more substantial issue than what might be observed at the inspected unit, or that might require a general assessment.
Occasionally, repairs that are planned to be undertaken at a building complex can require a substantial outlay of funds that may not be covered in the available monetary accounts of the building association. This might involve an assessment to each individual occupant. I would recommend gaining any information possible from the association regarding any planned repairs and the availability of funds to cover these situations, so as not to be surprised by a planned or special assessment.
Building Foundation Type(s): Crawlspace (Traditional Stem Wall)
Additional Buildings Inspected: None
Approximate Square Footage: 867
Approximate Year of Original Construction: 1983
Unless the wiring in the building has been fully updated, this building likely has wiring that predates the late 1980's. Branch circuit wiring installed in buildings built prior to the late 1980's is typically rated for a maximum temperature of only 60 degrees Celsius. This includes non-metallic sheathed (Romex) wiring, and both BX and AC metal-clad flexible wiring. Knob and tube wiring, typically installed in homes built prior to 1950, may be rated for even lower maximum temperatures. Newer electric fixtures including lighting and fans typically require wiring rated for 90 degrees Celsius. Connecting newer fixtures to older, 60-degree-rated wiring is a potential fire hazard. Repairs for such conditions may involve replacing the last few feet of wiring to newer fixtures with new 90-degree-rated wire, and installing a junction box to join the old and new wiring. It is beyond the scope of this inspection to determine if any such incompatible components are installed. Based on the age of this building, be aware that such components may be present.
Additional Services Performed with Inspection: None
Occupancy: Unoccupied
Building was vacant / unoccupied at the time of inspection. Vacant and unoccupied buildings present unique challenges, especially the piping and wiring systems which have not be subject to regular use prior to the inspection. While these systems can be tested, this one-time test is different than regular use and it is difficult to know how these systems will respond to regular use after the inspection. For example, septic systems may initially function and then fail under regular daily use. Plumbing traps may operate with no signs of leaks and then let go when being actively used for a few days. Shower pans may only leak when someone is standing in the shower and taking a shower. Seals for plumbing fixtures can dry up and leak when not is use. Sewer lines with roots may allow water flow, but then fail when waste and tissue are flushed; it can take a few days for that to backup. Please understand we tried our best to look for clues of past or existing problems to paint a realistic picture of the reliability of these systems during this inspection.
Animals Present: No
Access to the Property Was Granted By: Client's Agent
Attending the Inspection: Client's Agent
Approximate temperature during the inspection: 80F to 100F
Weather during the inspection: Clear, Dry
Ground/Soil surface conditions: Dry
Rain or Snow in Last 3 Days: No
For the Purposes of This Report, the Front Door Faces: East
Approximate Start and End Times: 5:00pm, 6:00pm
Reinspection Disclaimer and Documents
This was a limited re-inspection of only the specific building components or conditions listed below. It was not a full building inspection under ASHI Standards of Practice. No other items were evaluated. Only items that were accessible and visible at the time of this re-inspection were reviewed. Conditions may have changed since the original inspection, and any areas not re-inspected remain outside the scope of this visit.
Verification of repairs is often limited. Many repair details may be concealed behind finishes, coverings, or assemblies (such as wall materials, roofing layers, or flashings), making it difficult or impossible to confirm the quality or completeness of the work. In these cases, we rely on the visible portions of the repair and recommend obtaining repair documentation, invoices, and warranties from the qualified contractor who performed the work. No warranty, guarantee, or certification of repair quality is provided.
- Attached PDF/Media outlines what was inspected during this re-inspection.
Old Buildings May Contain Lead and Asbestos
In 1978, federal laws were passed to prohibit use of lead and asbestos in building materials. Manufacturers of building materials were allowed to sell existing stocks of materials that were manufactured with lead and asbestos, so even buildings constructed as late as the mid-1980's could possibly contain lead or asbestos. Identification and testing for lead and asbestos and other environmental testing is beyond the scope of this inspection. If you wish to seek additional information, please visit https://www.epa.gov/ or contact an environmental lab or industrial hygienist.
Grounds
Grading and Drainage
Site Drainage: Negative Slope (Noted - Repair)
Building Clearance to Grade: Siding Too Close to Soils - Repair
Downspout Discharge: Below grade, Downspout Repairs Recommended
Siding to Soil Contact Noted
Eliminate siding / soil contact at all areas to reduce the chances for deterioration and pest damage and repair any concealed damage as needed. Generally, a 6-inch clearance between soils and siding is recommended. This is often not realistic on older homes, but repairs should be made to achieve as much clearance as possible, and all direct soil contact should be eliminated. Maintaining this clearance is important not only to protect the siding, but also to help safeguard the underlying wall framing from moisture intrusion, rot, and wood-destroying pests. When creating this clearance, current standards recommend the grading adjacent to the building should be positively sloped at a 5% grade within 10 feet of the building.
See media for examples of locations:
Poor Site Grading
The grade of the yard sloped toward the building. Standards recommend at least a quarter-inch / foot slope away from the building for 10ft if possible to prevent water from draining toward the building. Over time, negative grading, as this is often called, can lead to moisture and even structural problems with the building, especially when roof drainage discharges to this area. Have this repaired as feasible by a qualified contractor. Often, a swale can be used to create a low point away from the house into which water can be diverted safely away from and around the building.
See media for details and locations:
Downspout Repairs Recommended
Downspout was missing and should be repaired by a qualified person. These should be in good condition, properly secured, and long enough (typically 3-5 ft) to ensure proper drainage away from the foundation. Water that pools around foundations and flatwork can lead to water intrusion, settlement, heaving, cracks, and other issues over time. Fortunately, these issues can be easily avoided when the drainage system is properly designed and in good working order.
See media for details and locations:
Underground Drains Noted
Underground downspout drainage system was observed. These are not within the scope of a general inspection and a functional water flow test was not performed. Suggest these be scoped with a camera to determine the condition or a functional water flow test be performed to ensure they flow well and do not back up under heavy rain. Underground drains that back up or leak can concentrate the water against/near the building and will increase the likelihood of water related issues such as foundation and slab movement, water intrusion, and deterioration of building materials. Monitoring these under heavy rains should be made part of your annual routine maintenance to prevent issues.
Driveways/Walkways/Flatwork
Driveway Material(s): Concrete
Walkway Material(s): Concrete
Patio Material(s): Concrete
Fencing
Present - No significant Issues
Trees and Vegetation
Trees & Vegetation: OK - No Issues Observed
Irrigation
Irrigation System: Present - Likely HOA's Responsibility
Irrigation System Noted - HOA Responsibility?
An exterior irrigation system was noted. Sprinkler and irrigation systems are beyond the scope of this inspection, but based on our experience, this one is likely maintained and managed by the HOA (Home Owners Association). Suggest inquiring with the association for further information about responsibilities.
Exterior Stairs and Guardrails
None Noted
Exterior
Siding and Trim
Trim Material: Wood
Siding Material: Wood
Hardboard/Masonite - Localized Painting Needed
The hardboard/Masonite siding and trim on this building was in need of some localized painting, caulking, and repairs. This should be done soon as the paint is its only protection against deterioration and swelling from water absorption. This engineered wood material does not have a durable track record, requires routine caulking and painting, and when exposed, easily absorbs water causing swelling at the cut edges, at the top where water rests, and the bottoms where water droplets linger. A full, professional paint job would be ideal, but localized painting will put the need for a full paint job off for a few years.
- Small sections may need to be replaced as they may have deteriorated too much to hold new paint well.
Recommendation: Have a professional painting/building contractor implement localized painting as needed.
Eaves
Minimal or No Eaves Noted.
This building was designed with no or very minimal eaves/overhangs. The eaves act like an umbrella for the building, by keeping most of the rainwater off of the siding, windows, and doors. Ensuring gutters are present at all drip edges and keeping them clean and draining well is important for a building with this design. Keep an eye out for gutter leaks as they can run down the siding and over time cause water damage. Suggest more routine monitoring of the exterior and expect the need for more vigilant maintenance for exposed sections of the building.
Exterior Doors
Style(s): Sliding glass, Glass panel doors
Lost Seals in Door Glazing
One of the insulated glass units (IGUs) in the exterior door glazing had failed seals. Failed insulated glass units commonly show condensation, fogging, residue, or corrosion between the panes of glass, which cannot be cleaned from the interior or exterior surfaces. This condition primarily affects the appearance and energy efficiency of the glazing. Replacement of the affected glass units by a qualified glass contractor may be desired to improve clarity and thermal performance. Please note that failed seals can sometimes be difficult to identify, as condensation between panes may vary depending on temperature, humidity, and seasonal conditions.
See media for locations:
Window Frames
Frame Material(s): Vinyl
Wall Vent/Exhaust Terminations
Condition: Inspected - OK
Roof, Chimney and Gutters
Roof Covering(s)
Condition: Repairs Recommended
Method of Inspection: Walked on roof
Style(s): Gable
Valleys: None
Covering Material(s): Three-tab composition shingle (Buyer)
Overlayed Roof Covering: No
Shingle Fastening Accessible For Inspection : No
Please note that when inspecting composition roof installations, we attempt and look under shingles to see how they have been fastened. Proper fastening is critical for successful roof performance. Often the shingles are bonding so well, they cannot be lifted to inspect the fastening. In this case, the shingles could not be lifted to see the fastening pattern because they were bonded well and prying them apart may cause damage. While this limits the visual inspection, this is a good sign, as loose, un-bonded shingles can be easily damaged by wind and would be written up as a defect.
Roof Replacement Recommended
The roof was done in a three tab composition shingle. The roof looks to be old and close to the end of its reliable service life. Roof replacement is recommended to ensure reliable roof performance. If this is a real estate transaction, the insurability of the roof should be verified.
Examples of observations noted include:
- missing shingles
- severely degraded shingles
Recommendation: Hire a qualified roofing contractor to further evaluate and replace this roof.
- If a second layer of shingles is added overtop, the first layer must be in good condition with no missing or damaged shingles as this acts as the underlayment for the new layer. Also, you should expect reduced shingle life with with two layers.
Flashings and Penetrations
Condition: Repairs Recommended
Roof Edge Flashing Missing
Edge flashing was not present at all locations which may not have been required when the roof was installed. Its job is to prevent water from running down the fascia and behind the gutters (if present). Installing edge flashing at all locations will help extend the life of the fascia and roof sheathing at the edges.
Recommendation: This should be added by the roofing company when the new roof is installed.
- Soffit and fascia damage was noted as a result of this and should be repaired by a qualified contractor.
Reinspected 6/1/2099: the front fascia board has been replaced, but it is not been caulked or painted and the gutter was still laying on the ground.
Appliance Exhaust Vent - Too Close to Wall or Roof
The exhaust B-vent was located too close to a nearby wall or roof. This can inhibit proper drafting and even present some safety issues or durability issues for the building's exterior. This vent should be
- 8-feet from an adjacent wall or 2-feet above the wall.
- 2-feet above anything within 10-feet.
- At least 8-feet from an operable window.
Recommendation: Have this further investigated and repaired as recommended by a qualified heating or plumbing contractor. This appears to have been like this for a long time and no issues were observed. While it still is technically not correct, corrections may not be necessary and a relocation could likely wait to be performed in the context of other repairs or upgrades.
Gutters and Downspouts
Gutter and Downspout Material(s): Aluminum
Gutter Cleaning Recommended
The gutters had excess debris in them and should be cleaned to ensure proper control of roof runoff. Ensure they are unobstructed, leak-free and properly sloped to drain as part of routine maintenance. Ensure the downspouts are clear as well as these can be clogged causing the gutters to fill which may cause damage to them or the building.
Skylights
Type(s): None noted
Attic
Access & Type
Access Location(s): Hallway
Inspection Methods: Entered and Visually Surveyed
Every reasonable effort was made to visually inspect the entire attic space(s); however, portions of the space could not be safely traversed. There was no ramp, catwalk, or other safe walking surface, and crawling/walking in the V of trusses or on top of framing risks damaging insulation, air and thermal barriers, wiring, and ceiling finishes and is not considered a safe or appropriate method of attic access. As a result, portions of the attic could not be seen or were observed from a distance using artificial lighting limiting the inspection of some areas.
Insulate and Air-Seal Attic Access
Recommend the attic access hatch pictured here have insulation and weather stripping installed to prevent heating and cooling losses to the attic since it was located within the building envelope.
- Glued, rigid foam board is recommended for these as fiberglass batts tend to fall off or not be reinstalled correctly.
Roof Framing and Sheathing
Framing Material: Trusses
Sheathing Material: Plywood
Staining/Mold-Like Substances Noted - Attic Ventilation Poor
Localized discoloration and mold-like substances were noted on portions of the attic roof sheathing or framing. This appeared older and inactive at the time of inspection, and the materials tested dry; however, the attic ventilation was poor. This type of staining is commonly associated with seasonal condensation from elevated attic humidity, especially during colder weather conditions. Ventilated attic spaces are generally considered exterior spaces or unconditioned environments, and mold-like substances in these areas are often isolated from the indoor living environment, which can make remediation subjective. No visible evidence suggested active moisture intrusion at the time of inspection, though seasonal conditions may still allow condensation to occur in the winter and contribute to continued staining, deterioration or mold growth over time.
Recommendation: Have a qualified contractor increase attic ventilation (see ventilation section) and monitor for worsening. If additional evaluation or testing for mold-like substances is desired, a licensed mold remediation specialist may be consulted. Small areas of mold can be easily cleaned with hydrogen peroxide.
Reinspected 6/1/2099: the mold like substance in the Attic still looked exactly like it did at the original inspection and it is not appear that anything has been done with this.
Fire Separation and Blocking
Standard
Attic Insulation
Insulation Type: Blown in Fiberglass
Attic Floor - Approximate R-Value: 21
Attic Cavity Ventilation
Condition: Repairs Recommended
Attic Cavity Ventilation Method: Turbine vents
Unconditioned Attic Cavity Ventilation Note
Attic/roof cavity ventilation is a frequently misunderstood element of building construction and its primary job is moisture reduction. All unconditioned attic cavities are required to have ventilation. The general default standard is 1 to 150 of the attic area and ideally, this comes from at least 60% lower roof cavity ventilation and 40% upper, but this is an over-simplification of the subject. As a good guiding principle the most important elements for healthy attic spaces, which are traditionally insulated and ventilated are:
- Make sure the ceiling between the living space and the attic is airtight
- Ventilate consistently across the whole lower part of the roof cavity with low, intake soffit venting
- Upper roof cavity venting is less important and if over-installed can exacerbate air migration into the attic from the living space by creating negative pressure in the attic.
- Avoid power ventilators when possible which can depressurize the attic and exacerbate air migration from the house into the attic.
For more information, please check out this crash course on attic cavity ventilation by Clicking Here
Non-Standard Roof Cavity Venting
The attic and roof cavity ventilation area looked to be inadequate. The goal of attic cavity ventilation is to keep it as close to ambient air temperature as possible. Adequate ventilation helps lower attic temperatures in the summer reducing cooling costs, prevents the build-up of moisture and condensation in the winter, and help extend the life of the roof system. As this building is made tighter, better insulated, and air-sealed for energy efficiency it is important to improve roof cavity ventilation as well.
- Not enough upper/exhaust ventilation was noted in this roof cavity section.
- No lower/intake soffit ventilation was noted in this roof cavity section.
- The mold-like substance noted on the roof framing/sheathing was likely a result of this poor ventilation causing condensation in the winter.
Recommendation: Consult with a qualified general contractor about adding roof ventilation as recommended.
For more information, please check out this crash course on attic cavity ventilation by Clicking Here
Electric Service
Service Entrance
Main Electrical Panel
Main Electric Panel Location : Exterior - West Side
Service Entrance (SE) conductor Size: Aluminum, #2, 100 amps
Main Panel Listed Max Amperage Capacity: Listing not visible
Main Panel Breaker Total Amperage Rating: 100 amps
Main Panel Manufacturer: Bryant
Surge Protection: Not Present
Overcurrent Protection Devices: Breakers
AFCI Breakers: Not Present
GFCI Breakers: Not Present
No Surge Protection Noted
No surge protection was noted at the electrical equipment today. The 2020 edition of the National Electric Code requires type I or type 2 surge protection on new or renovated homes. This code change reflects the growing complexity of electric appliances in our houses and the growing risk of damage to electrical equipment due to internal or external electrical surges. This short video explains more about electrical surges and surge protection. Recommend upgrading and adding surge protection for improved protection of the electrical appliances/devices in this building. Suggest doing this in the context of other electrical repairs or upgrades.
Electrical Grounding System
Present - Could Not Confirm
During a property inspection, every effort is made to inspect the visible components of the electrical system grounding. The grounding system is critical for safely discharging electrical surges, especially in the case of lightning strikes. However, there is no way in the context of a property inspection to verify the "effectiveness" of the grounding system as much of the system is not visible, and there are no practical tests one can perform in the way we can test a furnace or a plumbing fixture. However, if any defects were found, they will be documented in the observations of this report.
Electrical Bonding System
Bonding Noted on Water Pipes, Could Not Confirm
Attempts were made to visually inspect the electrical system bonding. However, there is no way in the context of a property inspection to verify the "effectiveness" of system bonding. All metallic systems in the building are required to be "bonded" (connected) to the the building's electrical grounding system. Bonding creates a pathway to shunt static charges (that would otherwise build up on the system) to earth, and to provide a pathway to trip a breaker in the event that these bonded metallic components became energized. If any issues were observed, they will be documented as repair items in the observations below.
Sub Panel
Sub Panel Location: Exterior (Exterior - West Side)
Sub Panel Voltage: 120/240 volt
Feeder Conductor Size: Aluminum, #2, 100 amps
Sub Panel Listed Max Amperage Capacity: 125 amps
Sub Panel Breaker Amperage Rating: 100 amps
Sub Panel Manufacturer: General Electric
AFCI Breakers: Not Present, Inconsistent with Modern Standards
GFCI Breakers: Not Present
AFCI Protection was Inconsistent with Modern Standards
AFCI (Arc Fault Circuit Interrupter) breakers, which were introduced around 2002, are designed to detect dangerous electrical arcing caused by damaged, loose, or aging wiring that standard breakers can not sense. These arcing conditions can generate high heat without drawing enough current to trip a conventional breaker, which increases fire risk🔥. Modern electrical safety standards now call for AFCI protection on most residential circuits, so it is common for older homes to fall short of these standards. While upgrades are not required for existing homes, improving AFCI protection is considered a meaningful safety improvement, especially when other electrical work is being performed.
Electric Distribution & Fixtures
Branch Wiring
Wire Material: Copper
Wiring Method: Non-Metallic Sheathed Cable
Open Electrical Splices
The open electrical splices should be further evaluated and repaired by a licensed electrical contractor. All wiring splices should be contained inside listed junction boxes. Open or "running" splices are a sign of amateur or incomplete electrical work and could indicate a need for additional repairs that are latent or concealed. Have this further evaluated and repaired as recommended by a licensed electrical contractor.
Locations noted include:
- Attic
Receptacles & GFCI's
Electric Receptacles: Three wire receptacles
Receptacle Inspection Method: Tested All Accessible
During inspection an effort was made to test and inspect all accessible electric receptacles and switches. In general, the scope of testing is directly related to access; where personal belonging and furniture obstruct access to receptacles and fixtures, fewer of them can be reasonably tested during inspection. All defects found during the inspection today will be listed in this report. Inspection/testing of the electrical system can be challenging. It should be anticipated that not all defects will be discovered and that some issues found may actually not be defects at all. Tools used to verify proper wiring and function can vary wildly in reliability/consistency. The kinds of tools that could be used to confidently analyze the system and its function cannot typically be done in the context of a standard Home Inspection. Issues identified, will be further discussed with recommendations in the electrical section below.
GFCI Testing Method: All Accessible GFCI's Tested
All readily accessible Ground Fault Circuit Interrupter (GFCI) receptacles (the ones with the “Test” and “Reset” buttons) were tested during the inspection. Standard-looking receptacles located in areas where modern standards recommend or require GFCI protection, including bathrooms, kitchens, garages, basements, laundry areas, exterior locations, crawl spaces, and near sinks, were also tested for GFCI protection using a plug-in ground fault tester. Any deficiencies observed with GFCI protection will be noted elsewhere in this report.
GFCI devices are important safety components designed to reduce the risk of severe electrical shock and electrocution by quickly shutting power off during a fault condition. Occasionally, a GFCI device may fail during testing and require replacement before power can be restored. Manufacturers generally recommend homeowners test GFCI devices monthly using the built-in “Test” and “Reset” buttons.
The video below provides additional information about GFCI protection and homeowner testing procedures.
GFCI Was Tripped And Would Not Reset
GFCI receptacles were found in the tripped position and would not reset. It is possible that because GFCI's will not reset without power, that they were wired in series with another hidden or unlocated GFCI that was tripped. The other possibility is that these are defective. Have these GFCI receptacles reviewed by a qualified electrician for safety.
Locations of affected GFCI's include:
- Exterior Back
Reinspected 6/1/2099: the old receptacle was still inoperative and has not been repaired.
Inoperative Receptacles Noted
Inoperative electric receptacles were noted. These may be on a switched or GFCI protected circuit, but no switch or tripped GFCI was found during the inspection.
Recommendation: Have inoperative electric receptacles further evaluated and repaired by a licensed electrician as needed.
Locations noted include:
- Dryer receptacle did not have power yet the breaker was on.
Reinspected 6/1/2099: repairs appear to be complete and the dryer receptacle had power and appear to be correctly wired
GFCI Protection Improvements Recommended
Since the 1970s, requirements for GFCI (Ground Fault Circuit Interruption) protection have changed, and locations requiring GFCI protection seem to get added with every code cycle. It is common for older residential buildings to have some or even many electric receptacles that do not meet modern safety standards. GFCIs have proven successful at reducing electrocutions, and it seems likely that someday, every circuit, receptacle, and appliance in the building will require GFCI protection. The first chart below shows how successful GFCIs have been at reducing risks from electrocution. The second illustration shows where GFCI protection is required as of the 2020 NEC. In terms of safety, its recommended to bring GFCI protection up to modern safety standards.
GFCI protection was inconsistent with modern minimum standards for safety in the following locations:
- Laundry Area
- Kitchen
Lighting
Tested - OK
Ceiling Fans
Present and Tested
The ceiling fans were tested and operating during the inspection. The ceiling fan mounting was not inspected as this is typically inaccessible to inspect. It is important the ceiling fans get well-mounted to the ceiling with proper fan fixture boxes.
Smoke and Carbon Monoxide Alarm Systems
CO Alarms: None Noted
Smoke Alarm Locations: On Main Floor
Smoke Alarms: Repairs are Needed
No Carbon Monoxide (CO) Alarms Observed
The installation of carbon monoxide alarms is recommended for all homes that have fuel burning appliances and/or an attached garage. No functioning installed alarms were observed in the dwelling during the inspection. In addition, Colorado State law (House Bill 09-1091) now requires approved carbon monoxide alarms in ALL homes being sold, when interior renovations that require a permit are made and/or when fuel burning appliances are replaced. The location should be: at least one alarm outside of all sleeping areas, within 15 feet, and one on each floor of the home. It is also recommended they be installed in rooms with fireplaces, wood stoves, gas heaters, or any fuel burning appliance. Best practice is to have these alarms hardwired with a battery back-up - though requirements are for the installation to meet the manufacturer's specifications. Carbon monoxide is a colorless, odorless gas that can cause sickness, nausea, and even death. Alarms have a useful service life of roughly 6-10 years, so changing them more frequently than smoke alarms is recommended.
Reinspected 6/1/2099: no carbon monoxide alarms were found inside the building
Smoke Alarm Repairs are Needed
Repairs or updates are needed for the smoke alarms. Modern standards require them inside each bedroom and on every level of the home, including the basement. On levels without bedrooms, install alarms in the living room (or den or family room) or near the stairway to the upper level, or in both locations. They should be on the ceiling at least 4 inches from the wall but may be on wall, no lower than 12 inches from the ceiling. Smoke alarms should be replaced every 10 years per the manufacturers instructions.
Specific observations noted include:
- Alarms were not present in all of the bedrooms.
Recommendation: Have a qualified person repair the smoke alarms so they conform to modern standards for safety.
Reinspected 6/1/2099: a new smoke alarm has been added to the bedroom and this repair has been completed
Low Voltage Wiring
Doorbell: Present - OK
Alarm or Surveillance System: Not Present
Smart/Connected Devices: None Noted
Plumbing
Water Supply
Water Pressure: 75 PSI
This shows the water pressure tested during the inspection. Generally, "normal water pressure" should be between 30-80 PSI, though pressures near or below 30 can result in poor functional flow to fixtures. Water pressures in excess of 80 PSI risk damaging supply piping components and should be controlled with a pressure-reducing valve.
Pressure Reducing Valve: Present
This building was properly equipped with a pressure-reducing valve to lower the utility water pressure (typically >100psi) to a safe level of 40-80 psi. These are usually adjustable if the need arises however, they are a maintenance item that can fail at any time which may cause high water pressure, or water flow issues.
Water Supply Source: Public water
Buried Water Supply Pipe Material: PVC
Main Water Shut-off Location: Noted In Media
The main water shut off for the building was located in the media below.
Water Treatment/Conditioners: Not Present
Distribution Piping
Supply Pipe Materials: Copper
Copper water supply pipes were installed. Copper pipes installed prior to the late 1980's may be joined with solder that contains lead, which is a known health hazard especially for children. Laws were passed in 1985 prohibiting the use of lead in solder, but prior to that solder normally contained approximately 50% lead. Note that testing for toxic materials such as lead, is beyond the scope of this inspection. Consider having a qualified lab test for lead, and if necessary take steps to reduce or remove lead from the water supply. Various solutions include:
- Flush water taps or faucets. Do not drink water that has been sitting in the plumbing lines for more than 6 hours
- Install appropriate filters at points of use
- Use only cold water for cooking and drinking, as hot water dissolves lead more quickly than cold water
- Treat well water to make it less corrosive
- Have a qualified plumber replace supply pipes and/or plumbing components as necessary
Functional Flow: Average
Leaking Supply Piping Observed
An active leak was noted at the supply piping. Have this further evaluated and repaired by a licensed plumber to ensure reliable performance.
- This was a small drip, but repairs should be mad as soon as possible
Reinspected 6/1/2099: a new fitting has been added in addition to a new water shut-off valve and pressure reducing valve. This repair was completed
Drain Waste & Vent
Discharge Type: Public Sewer
Waste and Vent Pipe Materials: ABS, PVC
Location of Sewer Cleanout: See Sewer Scope Chapter
Exterior Hose Bibs
Condition: Handle (Damaged), Not Sloped To Drain
Floor Drains, Sump & Ejector Pumps
Floor Drains: None noted
Sump Pumps: None noted
Sewage Ejector Pumps: None Noted
Water Heater
Hot Water Temperature
Water Temperature: 157
Water Too Hot
The water temperature was too hot and should be adjusted between 115 and 130 degrees F for safety as scalding times exponentially decrease with higher water temperatures. Children and elderly people with "thin" skin are much more susceptible to 2nd and 3rd degree burns from excessively hot water (see chart).
General Information
Condition: Operated Correctly
System Type: Conventional Storage Tank
Tanked Water Heater Maintenance Awareness
Storage-type (tanked) water heaters require periodic maintenance to perform as intended over their service life, though many homeowners are unaware that maintenance is recommended. Manufacturer guidance and general industry practices commonly include periodic flushing to reduce sediment accumulation and inspection of internal components such as heating elements or burners and the sacrificial anode rod, if equipped. If maintenance records or other evidence of recent servicing cannot be verified, having the water heater serviced may be appropriate to establish a known maintenance baseline and help maximize performance and remaining service life.
Manufacturer: Bradford-White
Capacity: 40 Gallons
Age: Bradford White (Y = 2022)
Energy Source: Gas
Unit Components
Expansion Tank: Inspected - OK
TPR (Temperature and Pressure Relief) Valve & Piping: Present - Not Tested
Circulation Pump: None Noted
Drain Pan: None Noted - Recommended
Condensate Drain System: Not Applicable
Venting System: Inspected - OK
No Drain Pan for Water Heater
No drain pan has been installed below the water heater here. A drain pan is recommended under water heaters that are located in finished spaces or where a leak could damage finishes. Where a pan does not already exist, the tricky part is providing a drain to the outside or plumbing system. A pan without a drain is often of limited benefit / protection. For improved protection from accidental water heater leaks, and where a drain is difficult to install, consider a pan with a moisture alarm.
Sewer Scope
Sewer Type & Access
Scope Findings
Pipe Materials: PVC, SDR, ABS
Anomalous Findings: Minor Issues Noted - Recommend Rescoping in 1-3 Years
Limitations: Tap Not Inspected (Too Much Friction)
Bellies/Sags: Minor
Sewer Main Tap Not Inspected Due To Friction
The tap at the city sewer line or septic tank was not inspected because there was too much friction between the camera push rod and the pipe. The push rod will buckle and not advance the camera if a high amount of friction from too many turns, debris, or scale on the pipe is present. Suggest review by a licensed plumbing contractor or drain cleaning professional for a proper assessment of the tap. Other recommendations and or repairs may be necessary after the assessment.
Minor Sag/Belly
The sag(s) seen during the sewer scope inspection were MINOR and were located approximately 85 feet from the access point. Minor sags may cause a buildup of debris but not usually enough to cause a negative effect on the sewer. A sag is considered minor if the water fills less than 25 percent of the pipe diameter. Corrective action for a minor sag is generally not required. Please note, that when the camera goes underwater, it makes visual inspection of the pipe at these areas difficult or impossible.
Recommendation: Re-scoping within the next one to three years is advisable to detect any worsening of the sag and accumulation of debris.
Fuel Storage and Distribution
Gas Meter
Fuel Piping
Gas Piping Materials Noted: Steel
Gas/Fuel Odors Noted: Yes - Natural Gas
Natural Gas Odor Noted at Time of Inspection
A natural gas odor was detected at the time of inspection. The presence of a gas odor is not a normal condition and may indicate a leak or failure within the fuel gas system, which can present a fire or explosion hazard.
- The source of the odor could not be pinpointed.
Recommendation: Contact the natural gas utility provider for immediate evaluation. The utility can determine whether the issue is related to the service equipment or piping and advise on any necessary corrective action.
Heating, Cooling, & Fireplaces/Stoves
Heating System
Condition: Fuel/Pilot Was Off (Not Operated)
Type: Gas forced air furnace
Gas forced air furnace observed. A critical component to all combustion heating equipment is the heat exchanger. This is the welded metal assembly inside the furnace that contains the products of combustion so that moisture, carbon monoxide and other products of combustion do not mix with interior air and get safely vented to the exterior. Heat exchangers on modern furnaces have an average life expectancy of 15-25 years. Unfortunately, heat exchangers are concealed inside the heating equipment; they are not visible and specifically excluded from a home inspection. Cracks in heat exchangers may be concealed and can pose a potential safety hazard making annual inspections of the system by a professional HVAC contractor a smart idea.
Energy Source: Gas
Manufacturer: Premier furnace company
Age: 1983
Temperature Difference Measurements: Not Tested - Unit was Inoperative
Number of Thermostats/Zones: 1
Condensate Drain System: Not Applicable
Appliance Fuel or Pilot Was Off - Not Operated
Fuel or pilot was off to this gas furnace at the time of inspection which rendered the unit inoperative, making this inspection a limited visual inspection only. These are not turned back on for safety reasons without written permission which was not obtained. Suggest verifying correct operation with the owner and/or having a HVAC contractor review it for possible maintenance and repairs as advised.
Older Gas Forced Air Furnace
The gas forced air furnace may be close to the end of its useful design life based on the average life span of these units being 15-25 years. While some can and do last longer, funds should be reserved to replace this furnace at any time. The risk of running a gas forced air furnace past its useful design life is that the furnace could continue to operate with a cracked heat exchanger. This is a safety hazard that may allow products of combustion to enter the supply air to the home. Furnace heat exchangers are not visible to inspection without expensive diagnostics, so it is difficult to know when the furnace could be posing a safety hazard to the occupants. Older furnaces like this are also less reliable and subject to the need for constant repairs. It can be more cost effective to simply replace these furnaces on a 20 years schedule. Suggest having this furnace serviced by a HVAC professional annually until replaced.
Evaporative Cooler
Location: Roof Mounted
Service Area: Entire Living Area
Condition: Operated - OK
The evaporative cooler was operated to check the operation of the fan, motor, water pump, and water supply and drain system, all of which appeared to be in good condition and operated correctly.
Thermostat / Control Knob: Tested
Manufacturer: Champion Cooler
Data Plate: Data Plate Image
Water Supply Line: Ran Outside Building
Exhaust Vents/Flues
Condition: Inspected - OK
Air Filter(s)
Filter Location(s): At the Air Handler
Number of Filters: 1
Filter Size(s): 12x20x1
Filtration Type and Condition: Missing
Heat and Cooling Distribution System(s)
Heat Source in Each Room: Present
Distribution Method: Forced Air / Ducts
Deteriorated Evaporative Cooler Ductwork
Sections of the evaporative cooler ductwork were deteriorated. Evaporative coolers introduce humid air into the duct system during operation, and over time this commonly causes corrosion, rusting, or deterioration of galvanized sheet metal ducting. Deteriorated ductwork may reduce airflow performance and can eventually allow air leakage or failure of the duct system.
Recommendation: Have the affected ductwork further evaluated and repaired or replaced as needed by a qualified HVAC contractor.
Reinspected 6/1/2099: the holes in the duct work have been fixed and a new flex duct has been added to the drop. This repair was completed
Mechanical Ventilation
Mechanical Ventilation Systems
Whole Building Fans and HRV/ERV(s): No Whole Building Mechanical Ventilation Noted
Bath Fan Ducting: Attic (Termination - Relocate)
Kitchen Fan Ducting: None noted
Dryer Ducting: Ducted to Exterior
Attic Termination - Relocated to Exterior
One of the duct(s) for the bathroom exhaust fan(s) terminated in the attic . Ultimately, it is best to vent these to the exterior to prevent mold growth and moisture damage. A qualified professional should review and repair as advised.
- This was likely contributing to the condensation issues noted in the attic.
Reinspected 6/1/2099: the bath fan has been vented to the exterior. This repair has been completed
Laundry Facilities
Dryer Connection(s)
Energy Source: 240V Electric
Transition Duct: Not Present
Dryer Make up Air: Appears Adequate
Washing Machine Connections
Condition: Visually Inspected - OK
Kitchen
Cabinet and Countertop(s)
Countertop Material(s): Laminate
Cabinet Material(s): Wood & Engineered Wood
Sink(s)
Condition: Repairs Recommended
Leaking Drain
The drain plumbing was leaking and requires immediate repair to prevent damage to the cabinet. This only leaks when the faucet is used. Hire a qualified plumber to repair.
Reinspected 6/1/2099: the kitchen sink did not leak anymore when tested. This repair was completed
Food Waste Disposer(s)
Disposer(s): Operated
Video(s) demonstrate the food waste disposer(s) operating.
Dishwasher
Dishwasher: Operated (Tested Note)
Dishwasher Air Gaps and Johnson Tees: Just a high loop
High Loop Noted
No air gap was noted for the dishwasher waste line, but they did run a high loop. This is contrary to typical standards but is generally satisfactory, and many jurisdictions in the state allow for simply a "high loop" installation.
Range, Oven and Cooktop(s)
Power Source(s): 240V Electric
Condition: Operated with IR
Ventilation
Ductless Fan - Electric Cooktop
Ductless Kitchen Cooktop Fan Noted
A ductless fan was noted for the electric cooktop/oven which recirculates air into the living space. Installation of a fan that ducts to the exterior is recommended to remove moist air and odors to the exterior.
Installed Microwave(s)
Tested - OK
Microwave Tested OK
The video below shows the operation of the built-in microwave. It was tested as a courtesy using neon capsules which react when microwaves are present.
Interior
Floor Coverings
Floor Material(s): Laminate
Walls, Ceilings, Trim, and Closets
Wall and Ceiling Material(s): Drywall, Popcorn Ceiling Texture
Cracks & Blemishes: None Noted
Wall Insulation: Unknown/Not Visible
Popcorn Ceilings May Contain Asbestos
The ceiling in some rooms contains popcorn texture. This product may contain asbestos as many of these products contained asbestos prior to 1978. After 1978, remaining stocks of material containing asbestos were sold and as the product was slowly phased out. Asbestos testing is beyond the scope of this inspection. The health risks posed by this substance are minimal unless the texture becomes friable or air borne. If you wish to remove the popcorn texture or have remodel plans that could involve cutting or removing this sheetrock, asbestos testing is recommended. Consult with an environmental lab for more information on asbestos testing. One safe option is always to drywall/sheetrock over this texture if you wish to have a different ceiling finish.
Doors
Door Material and Style(s): Hollow Core, Bi-Fold
Windows
Window Frame Material(s): Vinyl
Window Glazing(s): Double pane
Safety Glazing: Present Where Required
Escape and Rescue Openings
Escape and Rescue: Present - Meets Current Standards
IRC 2021 R310 - Escape and Rescue Openings
The following passage is from the 2021 International Residential Code and is meant as a reference for you. While older homes are not required to meet current code, escape and rescue openings are an important means of life safety in emergencies. They allow people to get out of home and first responders to get in. It states.....
"Basements, habitable attics, and every sleeping room shall have not less than one operable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, an emergency escape and rescue opening shall be required in each sleeping room. Emergency escape and rescue openings shall open directly into a public way, or to a yard or court having a minimum width of 36 inches that opens to a public way."
Bathroom -
General
Testing Procedure Note
Bathroom Testing Procedures
During inspection today all plumbing fixtures in the bathrooms were operated. A moisture meter was ran around toilets and tile shower enclosures to check for concealed leaks and sounded for loose tile and finishes in shower and tub enclosures. However, bathtub overflow drains are not tested as this risks damaging finishes around the tub. Monitor tubs while filling and avoid pushing water into the overflow. Even well-installed overflow drains can leak, as the gaskets that seal the overflow will dry out over time and may no longer provide a watertight seal. Monitor plumbing after moving into a new home as testing during inspection presents less stress on plumbing than daily use. Please note that vacant homes present additional risk as it can be difficult to distinguish how the plumbing system will respond to daily use. Any defects uncovered during inspection are listed in this report.
Sink(s)
Condition: Tested - OK
Cabinet and Countertop(s)
Countertop Material(s): Porcelain
Cabinet Material(s): Wood & Engineered Wood
Toilet
Condition: Tested - OK, Caulking (Not Caulked To Floor)
Toilet Not Caulked to Floor
The toilet was not caulked to the floor. Caulking the toilet to the floor is recommended and even required though opinions on this can vary. This prevents unpleasant "bathroom liquids" from flowing to an area that cannot be cleaned, and it also helps to secure these fixtures to walls and floors to prevent leaks that may occur from movement. Generally, most contractors prefer caulking the toilet to the floor, but leaving a gap on the back of the toilet that remains un-caulked so if the toilet leaks, water has an escape route. Repair as recommended by a qualified plumber.
Bathtub / Shower
Condition: Inspected - OK
Shower Surround Type: Acrylic/Fiberglass
Tub Type: Acrylic/Fiberglass
Ventilation
Type & Condition: Bath Fan (Operated OK)
Pests
No Significant Pest Issues Noted
Crawl Space
Access
Crawl Space Access Location: Exterior (South Side)
Method of Inspection: Fully Crawled or Walked
During inspection of the crawl space, every effort was made to inspect the entire space. Visual inspection of crawl spaces is difficult and limited as access is often restricted by pipes, ducts and sub-floor insulation as well as limited clearances.
Foundation/Floor Insulation
Insulation Type & Location: Fiberglass Batts, Floor System (Insulated with Vapor Barrier On Cold Side)
Approximate R-Value: R-11, Inconsistent
Improper Vapor Barrier Orientation at Crawl Space Floor Insulation
Fiberglass insulation was observed installed in the floor system above the crawl space with the vapor retarder facing the crawl space (cold side). Vapor retarders are intended to face the warm-in-winter side of the assembly; when installed on the cold side, they can trap moisture against the insulation and framing. This condition can reduce insulation performance and contribute to moisture accumulation, mold growth, and long-term deterioration of the floor structure.
Recommendation: Consider consulting a qualified building professional to evaluate improvements to the crawl space insulation and moisture control strategy, which may include removing or correcting the vapor retarder and considering alternative approaches consistent with modern building-science practices.
Floor Insulation Limits View of Components
The floor framing system was insulated which makes inspecting it difficult and hinders the detection of defects without out removal of the insulation. This is considered a limited review of this area as inspectors do not remove or damage insulation during a general home inspection.
Ventilation and Vapor Barrier
Ventilation Method: Inadequate Ventilation without Vapor Barrier
Vapor Barrier: None Present
Inadequate Crawl Space Ventilation - No Vapor Barrier
Crawlspace did not appear to be adequately ventilated for not having a vapor barrier laid over the soil. Proper ventilation prevents moisture buildup leading to mold growth. When no class 1 vapor barrier or radon mitigation system is present, adequate ventilation should be installed at 1sqft of opening to 150sqft of under floor space. If a class 1 vapor barrier is to be installed, that ratio can be reduced to 1sqft of opening to 1500sqft of under floor area. Mechanical exhaust fans on humidistats can also prevent the buildup of moisture with even less screened area. Full crawlspace encapsulation or a radon mitigation system would allow the wall venting to be removed and sealed up as moisture would no longer be an issue.
- No moisture issues were noted.
- Adding a sealed crawlspace liner over the soil and adding an exhaust fan on a humidistat (set to about 40%) would be the ideal repair here.
Recommendation: Suggest a building contractor specializing in crawlspace moisture control further evaluate.
A good read on the building science of crawlspaces can be found here: https://buildingscience.com/documents/insights/bsi-009-new-light-in-crawlspaces
Moisture
Approximate Relative Humidity: 60%
Condition: See Plumbing Chapter, Damp Crawl - Wet Soil & Elevated Humidity
Mold / Deterioration: No visible mold or building material deterioration noted
Damp Crawl Space
The crawlspace soil was excessively damp which was contributing to an elevated humidity level of approximately 60%. When the soil is too wet, it elevates humidity levels and can create moisture related issues such mold, deterioration, and an inviting habitat for wood destroying organisms. If any of these were present, they will be noted in the report. Humidity levels should be kept below 50% at all times to prevent these problems. A professional contractor specializing in basement/crawlspace moisture should identify the source of the water and mitigate the problem. Items such as vapor barriers, french drains/improved lot grading, gutter/downspout discharge improvements, sump pumps, and/or powered ventilation may need to be modified or installed to fully remedy the problem, protect the building, and ensure a clean dry crawlspace.
A good read on the building science of crawlspaces can be found here: https://buildingscience.com/documents/insights/bsi-009-new-light-in-crawlspaces
Structural Systems
Foundation
Condition: Inspected - OK
Evidence of Significant Renovations or Additions: No
Approximate Percentage of Foundation Visible: 100%
Primary Foundation Type: Crawl Space (Poured Concrete Footers, Poured Concrete Stem Walls)
Primary Foundation Location: Under Entire Building
Columns Posts & Beams
Condition: Inspected - OK
Floors Walls & Ceilings - Structural
Floor Structure Material(s): Wood Beams/Girders, 2x10 Wood Joists
Sub-Floor Material(s): Plywood
Sloping Floors: No Significant Slopes Noted w/o Tools
Wall Framing Material(s): Not Visible/Unknown
Wall Sheathing Material(s): Not Visible/Unknown
Ceiling Framing Material(s): Bottom Cord of Truss
Structural Cracking: None Noted
Trim or Cabinet Separation: None Noted
Check Out Procedure
Check Out List
Oven: Off
Dishwasher: Off / Finishing Cycle
Heating and Cooling: Restored to Pre-inspection Settings
Lights: Agent Turned Lights Off
Exterior Doors: Locked By Agent
Service Providers
Below is a list of local contractors we have come up with to help you with any repairs or consultation you may need. We have no affiliation or financial interest with these contractors and have put this list together from our own experiences and from people we work with. We make no guarantee on their ability to do the work, or the quality of the work itself. If any of these contractors performs exceptionally well or very poorly, we would appreciate you letting us know.
Appliance Repair: Genesis Appliance : 970-361-0733
Crawl Space Moisture Control: Square One Radon : Rob Hartop: 970-712-4570
Electrician: Unified Service Solutions: Justin Sack: 970-640-1311
Dave Fisher Electric: 970-242-4012
Excavation: Brian's Backhoe Service : 970-245-0268
Elevated Rents: Adam Quain: 970-417-2366
Environmental Testing
Asbestos: Grand River Environmental : 970-424-4749
Mesa Environmental (Asbestos Testing) : John Witkamp: 970-201-7070
Meth: Grand River Environmental : 970-424-4749
Lead Paint: Grand River Environmental : 970-424-4749
Environmental Engineering Consultants: Stacy Skinner: 970-433-2004
Radiation (Mill Tailings): Environmental Engineering Consultants: Stacy Skinner: 970-433-2004
Phase 1 Environmental Site Assessments: Grand River Environmental : 970-424-4749
Environmental Remediation, Abatement, Mitigation:
Radon: Square One Radon : Rob Hartop: 970-712-4570
Click here for NRPP approved radon mitigation professionals
Asbestos: Regional Asbestos: 970-242-0016
Lead Paint: Environmental Engineering Consultants: Stacy Skinner: 970-433-2004
Radiation (Mill Tailings): Environmental Engineering Consultants: Stacy Skinner: 970-433-2004
Mold: Environmental Engineering Consultants: Stacy Skinner: 970-433-2004
Foundation Repair: DWT & Assoc: Dale Thome: 970-261-1517
Mays Construction Specialties Inc.: 970-245-0834
Groundworks: 844-252-4383
Aspen Foundation Repairs LLC : 970-446-5453
Garage Door Installation and Repair: Monument Garage Door: Ryan Reimer: 970-201-5840
Mesa Door Systems: Walt McGinley: 970-234-2123
Gutters: Installation, Repair, & Cleaning: Top Tier Seamless Gutters: Chad Gardner: 406-860-1958
HVAC: Local Plumbing and Heating: Cory Smith: 970-644-1194
Junk Removal: Square U Away : 970-444-5865
Landscaping, Grading, and Drainage: PTL Landscaping : 970-985-9442
Masonry: L E Dangler Masonry Contractor: 970-523-4550
Mobile/Manufactured Home Leveling & Foundation Repairs: DWT & Assoc: Dale Thome: 970-261-1517
Plumbing: Local Plumbing and Heating: Cory Smith: 970-644-1194
True Plumbing: Stephan Hedemark: 970-946-7922
Pool Cleaning, Maintenance, & Inspections: Rocky Mountain Aquatics: Patrick Kitson: 970-424-7366
Roof Restoration (Asphalt Composition Shingles) with Minor Repairs: Roof Maxx of Grand Junction: Nate Anderson: 970-846-8010
Roof Service(Residential): JP's Roofing: Jake Palmer: 970-683-0962
Bro's Roofing: 970-651-7947
Olivera Roofing: 970-208-7149
Roof Service (Commercial): Full Curl Roofing Co: Jake wood: 970-985-1350
Bro's Roofing: 970-651-7947
Sewer/Septic
Septic System Inspections: Scope It Out: Chris Heineman: 970-210-2471
Sewer Line Repairs: Rocky Mountain Sewer Pros: 970-307-4667
Sewer Line Inspections (Reversed - From Main into the Building) : Sightline Solutions: 970-623-2652
(When no accessible cleanout is found near building or sewer main was too far from cleanout and could not be inspected during our scope)
Structural/Civil Engineer: SGM: 970-930-8228
Termite & Pest Control: Chrome Pest Control: 970-300-3307
Additional Resources
Home Repair Manual & Seasonal Maintenance Checklist
Below are helpful links that will educate you on your property and its systems. Taking the time to learn about your home may save you time and money in the future! As always, please do not hesitate to contact us if you have any questions!