This time sensitive document was prepared for the client listed on the Cover Page of this report. Any reproduction, use, or resale of this document by individuals other than who is listed on the report cover page, or their assigns, is not supported by the inspector and company.
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this RV home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified RV technician. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase.
Acceptable (A) = A visually observed item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Fair (F)= The item or its components is not in need of immediate repair but wear and tear exists and the item is not in optimum condition. Some opinions may elect to repair or replace this item now while others may wait.
Poor (P) = The item, component or unit is not functioning as intended and replacement is recommended, or needs further inspection by a qualified RV technician.
Not Inspected (NI)= The item, unit or component was not inspected, and no representations were made as to whether or not it was functioning as intended and a statement for the reason for not inspecting may be made.
Not Present (NP) = This item, component or unit is not in this RV.
NRVIA Standards of Practice
Purpose, Scope and General Statements
1 – The purpose of the Standards of Practice is to establish a uniform standard for the companies RV Inspector to inspect and report in an objective manner the conditions of a Recreational Vehicle and its components.
2 – The Standards describe the components, and systems included in an RV Inspection.
3 – The Standards apply to motorized and towable types of RVs as defined by the RV Industry.
4 – The Standards apply to a visual inspection of those areas, components and systems that are readily accessible to determine at the time of inspection that they are performing their intended function without regard to life expectancy.
5 – The purpose of the RV inspection is to identify visible and operational defects as permitted by the current conditions that in the judgment of the RV Inspector will adversely affect the function or integrity of the items, components and systems of the Recreational Vehicle.
6 – RV Inspections performed under the Standards of Practice are basically visual and rely upon the opinion, judgment, education and experience of the RV Inspector and are not intended to be technically exhaustive.
7 – RV Inspections shall be performed in a time period sufficient to allow compliance with the provisions of the NRVIA Standards of Practice.
8 – RV Inspections performed under the Standards shall not be construed as being a compliance inspection of any code, governmental regulation or manufacturer’s installation instructions or procedures. In the event a law, statute or ordinance prohibits a procedure recommended in the Standards, the RV Inspector is relieved of the obligation to adhere to the prohibited part of the Standards.
9 – RV Inspections performed under the Standards are not an expressed, implied warranty or guarantee of adequacy, performance or useful life of any RV, any of its components or systems.
10 – Only those items specifically listed on the RV Inspection Report will be included in the RV Inspectors evaluation.
11 – The RV Inspector shall report any system or component included in the Standards of Practice which were present at the time of the RV Inspection but were NOT inspected and provide the reason they were not inspected.
General Limitations and Exclusions
1 – RV Inspections performed under the companies Standards of Practice exclude any items concealed or not readily accessible to the RV Inspector. The RV Inspector is not required to move furniture, personal or stored items. Lifting floor covering, accessing interior walls and ceilings in which could damage or destroy the components or systems being evaluated is not part of the RV Inspection.
2 – The determination of the presence of damage caused by insects or water is only to be evaluated by observation with an opinion being rendered by RV Inspector that is to make the client aware of the issue.
3 – Excluded from the Standards of Practice is the determination of indoor air quality of the RV and it’s consequence of physical damage, toxicity, odors, waste products and noxiousness.
4 – The RV Inspection and report are opinions only that are based upon the visual observation of the existing conditions of the RV at the time of the RV Inspection. The report is not intended to be or construed as a guarantee, warranty or any form of insurance. The RV Inspector will not be responsible for any repairs or replacement with regard to the RV or its contents.
5 – The RV Inspector is not required to enter any premises that visibly show a threat to the safety of the RV Inspector or others nor inspect any area or component that poses a danger to the RV Inspector or others.
6 – The NRVIA Certified RV Inspector will inspect and report on the RV items listed in this report and their condition during the RV Inspection. Any additional items of inspection will be dependent upon any agreements that are made between the client and the RV Inspector.
How to Read This Report
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, descriptions, videos and hot links to additional information.
The best way to get the layers of information that are presented in this report is to read your report online, which will allow you to expand your learning about your RV. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with a link to additional information.
This report can also be printed on paper or to a PDF document.
Chapters and Sections
This report is divided into chapters that parcel the RV into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the RV. You can navigate between chapters with the click of a button on the left side margin.
Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the RV was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section and it may simply say “tested,” or “inspected.”
Observation Labels
All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
- Life Safety Issue:The following items indicate that the condition is a LIFE SAFETY ISSUE. It could cause accident or harm. It is recommended that a qualified RV technician or appropriate service person investigate further and correct as needed.
- Major Issue:The following items indicate that the condition is a MAJOR ISSUE. It impacts longevity of the vehicle, can be a possible costly repair and/or warrants immediate repair. It is recommended that a qualified RV technician or appropriate service person investigate further and correct as needed.
- Minor Issue:The following items indicate that the condition is a MINOR ISSUE. It does not impact the operation or use of the vehicle and can possibly be repaired later. It is recommended that a qualified RV technician or appropriate service person investigate further and correct as needed.
- Notice / Comment:Refers to aside information and /or any comments elaborating on descriptions of systems in the RV or limitations to the RV inspection.
- Description:Detailed description of various aspects of the coach noted during the inspection.
Summary Page
The Summary Page is designed as a bulleted overview of all the observations noted during inspection. This helpful overview is not a substitution for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report as the Summary Page does not include photographs or photo captions.
Summary
Life Safety Issues
- ES1VA1VD-4 Electrical System 120 Volt AC and 12 Volt DC:
The inspector observed that the battery covers are not attached and therefore venting as required by NFPA is not satisfied. It is recommended that this be service by qualified RV technician.
- PTLC-1 Propane Tank, Lines and Connections:
The inspector observed that the streetside LP tank has a 2003 date code. Propane cylinders must be requalified or replaced every 5 or10 years depending on the cylinder type, condition, and previous requalification method. (Ref. 49 CFR § 180.205(d) and 180.209(e).) Recommend that this be replaced with a newer tank.
- PTLC-9 Propane Tank, Lines and Connections:
The inspector recommends installing a larger Fire Extinguisher, 10 B:C is recommended.
Major Issues
- RE-2 Roof Exterior:
The inspector observed a number of areas along the front cap joint where the sealant is deteriorating, cracking & separating. It is recommended that the front cap sealant be repaired by a qualified RV technician to prevent future water intrusion.
- RE-3 Roof Exterior:
The rear cap roof joint, on both the curbside and streetside corners, have cracked sealant. It is recommended that
these areas be repaired by a qualified RV technician to prevent future water intrusion.
Minor Issues
- ES-2 Exterior Sidewalls:
The inspector observed a crack in the streetside wheel fairing. It is recommended that this be serviced by a qualified RV technician.
- S-1 Slideouts:
Inspector observed gaps in sealant of the lower front T-Molding on the curbside front slideout. It is recommended that this
be serviced by a qualified RV technician.
- S-2 Slideouts:
Inspector observed gaps in sealant of the lower front T-Molding on the center streetside slideout. It is recommended that this be serviced by a qualified RV technician.
- AAC-1 Appliances: Air Conditioners:
The inspector observed a low Delta-T reading on the AC. It is recommended that this be serviced by a qualified RV technician.
Notice / Comment
- WS-1 Water Systems :
The coach was winterized. The inspector was not able to test the water systems which includes the hot water heater.
- WS-2 Water Systems :
A water pressure regulator was not present in the coach. High water pressure can burst your RV's pipes, cause leaks, and loosen connections within the plumbing system. It is recommended that a water pressure regulator be purchased before using the coach.
- PTLC-3 Propane Tank, Lines and Connections:
The propane system passed the leak test.
- AAC-2 Appliances: Air Conditioners:
The inspector observed that the air conditioner filters were dirty. It is recommended that they be cleaned to improve the efficiency of the units.
The Full Report
Roof Exterior
Roof
Vents
Air Conditioner Front
Air Conditioner Center
Air Conditioner Rear
Antennas
Other Roof Equipment
Tires and Wheels
NOTE
Curbside Front-Tire/Wheel
Curbside Center-Tire/Wheel
Curbside Rear-Tire/Wheel
Streetside Rear-Tire/Wheel
Streetside Center-Tire/Wheel
Streetside Front-Tire/Wheel
Spare-Tire/Wheel
Electrical System 120 Volt AC and 12 Volt DC
Hot Skin Tests
Power Cord
Electrical Panel & Fuses
AC Outlets & GCFI
Power Converter
Generator
Inverter
Surge Protector
Solar Battery Management System (BMS)
12 Volt DC House Battery
Propane Tank, Lines and Connections
NOTES
DOT Tanks
LP Leak / Drop Test
CO Detector
Combination LP /CO Detector
Smoke Detector
Garage Smoke Detector
Fire Extinguisher
Fire Extinguisher - Garage
Appliances: Other
Water Heater
Furnace
Washer / Dryer
In-House Vacuum System
Electric Fireplace
Ceiling Fan
Appliances: Air Conditioners
NOTE:
Air Conditioners - Front
Air Conditioners - Center
Air Conditioners - Rear/Garage
General Info
Type of Inspection: Buyer: Pre-Purchase RV Inspection
Style of RV: Travel Trailer - Toy Hauler
RV Status: Vacant: Private Seller
Client Present: No
Vehicle Information
VIN Information
VIN Number: Photo Included, 573FM4539J12#####
VIN Location: Door Panel
VIN Number / VIN Data Plate Photo:
RVIA / Canadian Seal
RVIA / Canadian Seal Number: Located by Entrance Door, SC487####
RVIA / Canadian Seal Photo:
Manufacture Information
Brand of RV: Manufacturer's Brand Name, Momentum
Model: RV Designation, 399TH
Manufacturer Name / Location: Grand Design / Middlebury, IN
Gross Vehicle Weight Rating (GVWR): From Data Plate, 20,000 lbs
State License Plate
State Inspection Sticker Current: Not Required
State License Plate Current: Yes, MN / RW5####
State License Plate Photo:
Roof Exterior
Roof
Roof Type: Rubber (TPO)
Areas of Possible Water Intrusion: Yes
Roof Condition:Acceptable
Front Cap, Joints and Seals:Fair
Awning Rail Trim (Curbside):Acceptable
Rear Cap, Joints and Seals:Fair
Trim Rail (Streetside):Acceptable
Roof Ladder Type: Mounted
Ladder - Roof Access:Acceptable
The inspector observed a number of areas along the front cap joint where the sealant is deteriorating, cracking & separating. It is recommended that the front cap sealant be repaired by a qualified RV technician to prevent future water intrusion.
The rear cap roof joint, on both the curbside and streetside corners, have cracked sealant. It is recommended that
these areas be repaired by a qualified RV technician to prevent future water intrusion.
Vents
Vents - Manual Crank (14 x 14):Not Present
Vents Powered (14x14):Acceptable
Exterior Vent Covers:Acceptable
Plumbing Vent Covers:Acceptable
Refrigerator Roof Vent:Not Present
Skylights:Acceptable
Air Conditioner Front
AC Shroud:Acceptable
AC Exterior Coils:Acceptable
Air Conditioner Center
AC Shroud:Acceptable
AC Exterior Coils:Acceptable
Air Conditioner Rear
AC Shroud:Acceptable
AC Exterior Coils:Acceptable
Antennas
TV Antenna - Moves Up and Down: Yes
TV Antenna - Cleaned and Maintained: Yes
Antenna Power Booster Operates: Yes
TV Antenna Exterior Roof Unit:Acceptable
TV Antenna Interior Handle and Crank:Not Present
Satellite Antenna:Not Present
Radio Antenna:Not Present
Other Roof Equipment
Number of Solar Panels: None
Solar Panels:Not Present
Exterior Sidewalls
Front Cap / Wall
Exterior Wall Surface Type: Paint with Decals
Any Damage or Discoloration or Delamination: No
Sidewall Condition:Acceptable
Paint and Decals:Acceptable
Windows: None
Windows:Not Present
Cargo Door: Doors with Keyed Lock
Cargo/Access Doors:Acceptable
Front Wall Photo:
Curbside - Sidewall
Exterior Wall Surface Type: Paint with Decals
Any Damage or Discoloration or Delamination: No
Sidewall Condition:Acceptable
Paint and Decals:Acceptable
Windows: Glass with No Frame
Windows:Acceptable
Cargo Door: Doors with Keyed Slam Latch
Cargo/Access Doors:Acceptable
Rear Cap / Wall
Exterior Wall Surface Type: Paint with Decals
Any Damage or Discoloration or Delamination: No
Sidewall Condition:Acceptable
Paint and Decals:Acceptable
Windows: None
Windows:Not Present
Cargo Door: None
Cargo/Access Doors:Not Present
Streetside Sidewall
Exterior Wall Surface Type: Paint with Decals
Any Damage or Discoloration or Delamination: Yes
Sidewall Condition:Fair
Windows: Glass with No Frame
Windows:Acceptable
Cargo Door: Doors with Keyed Lock, Doors with Keyed Slam Latch
The inspector observed a crack in the streetside wheel fairing. It is recommended that this be serviced by a qualified RV technician.
Entrance Doors
Front Entrance Door
Type of Entrance Door: Fiberglass
Keyless Entry Door Lock System: Yes
Keyless Entry Door Lock Functional: Yes
Keyed Door Lock / Deadbolt: Yes
Keyed Door Lock / Deadbolt Functional: Yes
Type of Step System: Manual
Number of Steps: Four
Grab Bar Type: D-Ring Handle
Door Condition:Acceptable
Rear Entrance Door
Type of Entrance Door: Fiberglass
Keyless Entry Door Lock System: No
Keyless Entry Door Lock Functional: Not Present
Keyed Door Lock / Deadbolt: Yes
Keyed Door Lock / Deadbolt Functional: Yes
Type of Step System: Manual
Number of Steps: Four
Grab Bar Type: Grab Handle
Door Condition:Acceptable
Awnings
Front Curbside Awning
Awning Material: Vinyl
Operational Type: Electric
Frame and Latching Mechanism:Acceptable
Fabric Condition:Acceptable
Awning Operation:Acceptable
Rear Curbside Awning
Awning Material: Vinyl
Operational Type: Electric
Awning Light: Light At Awning Roller
Frame and Latching Mechanism:Acceptable
Fabric Condition:Acceptable
Awning Operation:Acceptable
Door Awning:
Rear Garage Awning
Awning Material: Vinyl
Operational Type: Electric
Awning Light: On Wall
Frame and Latching Mechanism:Acceptable
Fabric Condition:Acceptable
Awning Operation:Acceptable
Garage Awning:
Slideouts
Curbside Center Slideout
Slideout Roof Type: (TPO) Rubber
Slideout Drive System: Electric Motor w/Gear and Rack System
Slideout Roof:Acceptable
Slideout T-Molding Trim:Fair
Seals, Sweeps and Gaskets:Acceptable
Slide Rail Gear Rack System:Acceptable
Wiring Harness under Slideout:Acceptable
12 Volt DC Control and Switches:Acceptable
Slideout Operation:Acceptable
Slideout Awning Topper Operation:Not Present
Slideout Awning Topper Frame & Latching Mechanism:Not Inspected
Slideout Awning Topper Fabric:Not Present
Inspector observed gaps in sealant of the lower front T-Molding on the curbside front slideout. It is recommended that this
be serviced by a qualified RV technician.
Streetside Rear Slideout
Slideout Roof Type: (TPO) Rubber
Slideout Drive System: Electric Motor w/Gear and Rack System
Slideout Roof:Acceptable
Inspector observed gaps in sealant of the lower front T-Molding on the center streetside slideout. It is recommended that this be serviced by a qualified RV technician.
Streetside Front Slideout
Slideout Roof Type: (TPO) Rubber
Slideout Drive System: Lippert Schwintek w/In-wall Electric Motor
Slideout Roof:Acceptable
Slideout T-Molding Trim:Acceptable
Seals, Sweeps and Gaskets:Acceptable
Slide Rail Gear Rack System:Acceptable
Wiring Harness under Slideout:Not Present
12 Volt DC Control and Switches:Acceptable
Slideout Operation:Acceptable
Slideout Awning Topper Operation:Not Present
Slideout Awning Topper Frame & Latching Mechanism:Not Present
Slideout Awning Topper Fabric:Not Present
Tires and Wheels
NOTE
-The National Transportation Safety Board (NTSB) and some tire manufacturers are recommending that all tires older than six years should be replaced, regardless of their condition.
Curbside Front-Tire/Wheel
Tread Depth: 10/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Visually Verified, 4917
Load Capacity: Single Tire Rating, 4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 89.9
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Tire Condition:Acceptable
Tire Tread Condition:Acceptable
Curbside Center-Tire/Wheel
Tread Depth: 10/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Visually Verified, 4917
Load Capacity: Single Tire Rating, 4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 85.2
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Tire Condition:Acceptable
Tire Tread Condition:Acceptable
Curbside Rear-Tire/Wheel
Tread Depth: 8/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Visually Verified, 4917
Load Capacity: Single Tire Rating, 4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 92.2
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Tire Condition:Acceptable
Tire Tread Condition:Acceptable
Streetside Rear-Tire/Wheel
Tread Depth: 8/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Visually Verified, 4917
Load Capacity: Single Tire Rating, 4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 94.7
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Tire Condition:Acceptable
Tire Tread Condition:Acceptable
Streetside Center-Tire/Wheel
Tread Depth: 10/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Visually Verified, 4917
Load Capacity: Single Tire Rating, 4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 93.2
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Tire Condition:Acceptable
Tire Tread Condition:Acceptable
Streetside Front-Tire/Wheel
Tread Depth: 10/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Unable to Visually Verify
Load Capacity: Single Tire Rating, 4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 91.5
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Tire Condition:Acceptable
Tire Tread Condition:Acceptable
Spare-Tire/Wheel
Tread Depth: 10/32 inch
Tire Brand: Westlake
Tire Size: ST235/80R16
DOT Date: Visually Verified, 4917
Load Capacity: Single Tire Rating, 4,080 lbs4,080 lbs
Load Range: G
Maximum Air Pressure: 110 PSI
Current Air Pressure in Tire: Tire Gauge Reading (psi), 87.0
Spare Tire Rack Type: Drop Down Cable
Spare Tire Jack and Tools: No
Valve Extensions Installed: No
Tire Pressure Monitors Installed: No
Spare Tire Assembly:
TT-Running Gear
Running Gear
Axle Type: Leaf Springs with Shackles
Number of Axles: Three
Axle - Did Inspector Check for Visible Signs of Rust?: Yes
Axle - Did Inspector Check for Visible Signs of Bent or Damaged Components?: Was damage present?, No
Axle - Did Inspector Check for Visible Signs of Oil Stains?: Yes, Was any present?, No
Brake Type: Electric
U-Bolts and Nuts Have been Evaluated: Yes
Leaf Springs Have been Evaluated: Yes
Hangers Have been Evaluated: Yes
Shackles Have been Evaluated: Yes
Spring Equalizers Have been Evaluated: Yes
Shock Absorbers Have been Evaluated: Not Present
Suspension Bolts with or without Zerk Fittings Have been Evaluated: Yes
Frame - Did Inspector Check for Visible Signs of Rust?: Yes, Was any present?, No
Frame - Did Inspector Check for Visible Signs of Bent or Damaged Components?: Yes, Was any present?, No
Frame - Did Inspector Check for any Visible Signs of Oil Stains?: Yes, Was any Present?, No
Running Gear - Condition:Acceptable
Frame - Condition:Acceptable
TT- Hitch & Leveling System
7-Pin & Breakaway
5th Wheel - Front Landing Gear: Hydraulic, Electric
5th Wheel - Rear Stabilizing System: Hydraulic, Electric
5th Wheel Landing Gear - Condition:Acceptable
5th Wheel - Pin Box: Fixed Pin Swiveling
5th Wheel - Condition: Acceptable
5th Wheel - Goose Neck Adapter: No
Leveling System Type: Electric, Hydraulic
Leveling System Manufacturer: Lippert
Leveling - Inspect for Visible Signs of Damage: Yes
Leveling - Ensure Jacks Extend and Retract Fully: Yes
Leveling - Inspect for Leaks or Mechanical Issues: Yes
Leveling System Condition:Acceptable
12 Volt DC Chassis Lights
NOTE
-The inspector has verified the items in this section are functional.
Lights
Front Clearance Lights:Acceptable
Rear Clearance Lights:Acceptable
Streetside - Marker Lights:Acceptable
Curbside - Marker Lights:Acceptable
Left Turn and Brake Light:Acceptable
Right Turn and Brake Light:Acceptable
Backup Lights:Not Present
License Plate Light:Acceptable
Utility Lights:Acceptable
Compartment Lights:Acceptable
Hitch Lights:Not Present
Porch Lights:Acceptable
Security Lights:Not Present
Waste Dump Lights:Not Present
12VDC at Trailer Connector:No
Electrical System 120 Volt AC and 12 Volt DC
Hot Skin Tests
Hot Skin Test - Was any Frame and Running Gear Voltage Recorded:No
Hot Skin Test - Was any Exterior Surface Voltage Recorded:No
Hot Skin Test - Was any Exterior Wall Surface Voltage Recorded:No
Hot Skin Test - Was any Door Handles and Frames Voltage Recorded:No
Hot Skin Test - Was any Window Frames and Trim Voltage Recorded:No
Hot Skin Test - Was any Other Voltage Recorded:No
No unsafe voltage over five volts was recorded.
Power Cord
Power Source: 50 Amp / 240 Volts AC
Power Cord Condition:Acceptable
Electrical Panel & Fuses
Inside Electrical Panel Box Condition: Acceptable
12 Volt DC Fuse Panel Box Condition: Acceptable
Fuses Condition: All Operational
Fuse Connections Condition: Good Connection
Wires and Terminals Tight: Solid Connection
Electrical Panel Box - Signs of Repair or Service:No
Electrical Panel Box - Circuit Breakers in Place:Yes
Electrical Panel Box - Wiring Secure:Yes
Electrical Panel Box - All White, Black and Ground Wires Kept Separate:Yes
Fuse Panel Box Inspected:Yes
120-Volt Electrical System:
AC Outlets & GCFI
GCFI Reset Location: Bathroom
GCFI / Polarity / Voltage Test - Kitchen Receptacles:Yes
GCFI / Polarity / Voltage Test - Bath and Toilet Area Receptacles:Yes
GCFI / Polarity / Voltage - All Exterior Receptacles:Yes
GCFI / Polarity / Voltage Test - Receptacles Storage Bay Areas:Not Present
Polarity / Voltage Test Bedroom Receptacles:Yes
Polarity / Voltage Test - Dining Area Receptacles:Not Present
Polarity / Voltage Test - Living Room Receptacles:Yes
Polarity / Voltage Test - Behind Refrigerator:Yes
Polarity / Voltage Test - Receptacles Behind all Electronics and Appliances:Yes
Voltage Test - USB / 12-Volt Power Ports:Not Present
Power Converter
Power Converter - AC On (DC Voltage with Shore Power On): Operational Test, 13.18
Power Converter - AC Off (DC Voltage with Shore Power Off: Operational Test, 12.18
Power Converter - Verified: Acceptable
Power Converter - Did DC Voltage Drop at Least 1/2 Volts:Yes
Generator
Generator - Brand: Onan
Generator - Model # / Serial #: From Manufacturer's Label, 5.5HGJAB-6755L / A180296486
Generator - Hours of Operation: From Interior Control Panel, 13
Generator - Radiator Reservoir and Hoses Condition:Air Cooled
Generator - Transfer Switch:Acceptable
Generator - Voltage Output: Voltage Measured Under Load, 118.4
Generator - Frequency Output: Frequency Measured Under Load, 60
Generator - Fuel Level Greater than 1/4 Tank:Yes
Generator - Starts and Runs:Yes
Generator - Tested Under Load:Yes
Generator - Radiator:Not Present
Generator - Coolant Analysis Performed:No
Generator - Oil Analysis Performed:No
Generator - Automated Transfer Switch:Yes
Inverter
Inverter - Inspected Cables, Wiring and Fuses:Not Present
Surge Protector
Surge Protector - Brand: SurgeGuard
Surge Guard - Model # / Serial #: 44270
Surge Protector - General Condition: Acceptable
Surge Protector - Cables, Wiring and Fuses:Yes
Surge Protector:
Solar Battery Management System (BMS)
Solar Battery Management System (BMS) - Operational:Not Present
12 Volt DC House Battery
12 Volt DC House Battery - Location: Front Cargo Bay
12 Volt DC House Battery - Box Condition: Fair
12 Volt DC House Battery - Cables and Terminals Condition: Acceptable
12 Volt DC House Battery - Vented and Secure: No
12 Volt DC House Battery(s) - Operational:Yes
12 Volt DC House Battery(s) - Matched for Size and Age:Yes
12 Volt DC House Battery(s) - Positive and Negative Cables Matched for Load:Yes
12 Volt DC House Battery(s) - Have They Been Maintained:Yes
The inspector observed that the battery covers are not attached and therefore venting as required by NFPA is not satisfied. It is recommended that this be service by qualified RV technician.
Water Systems
Notes
-Due to the inability to determine the age and quality of the water in the fresh water tank, the tank should be drained and sanitized before refilling for use.
-Due to the types of materials and waste used in the tanks and depending on previous maintenance, fresh and waste monitor sensor probes may perform inaccurately between applications due to build up.
The coach was winterized. The inspector was not able to test the water systems which includes the hot water heater.
City Water
City Water - Food Grade Hose Available for Test:Yes
City Water - Pressure Regulator Available:No
City Water - Connections Operate:Not Inspected
City Water - System Holds Pressure:Not Inspected
City Water System Condition:Not Inspected
City Water Connection Condition:Acceptable
A water pressure regulator was not present in the coach. High water pressure can burst your RV's pipes, cause leaks, and loosen connections within the plumbing system. It is recommended that a water pressure regulator be purchased before using the coach.
On-Board Water System
On-Board Water System - Tested Fresh Water Fill: Not Inspected
On-Board Water System - Pressure System Works: Not Inspected
On-Board Water System - Pump Creates and Holds Pressure: Not Inspected
On-Board Water System: Tank, Water Pump and Fixtures for Tank Fill Condition:Not Inspected
Operation and Condition of Outside Shower:Not Inspected
Operation and Condition of Kitchen Faucet:AcceptableFairPoorNot InspectedNot Present
Operation and Condition of Bathroom Faucet:Not Inspected
Operation and Condition of Shower:Not Inspected
Operation and Condition of Toilet:Not Inspected
Black Water Tank
Black Water Tank - Valve Operates: Yes
Black Water Tank - Valve Type: Cable Pull
Black Water Tank - Tank or Valve or Line Leaks: No
Black Water Tank - Drain Cap in Place: Yes
Black Water Tank Drain Cap Holds Waste Water Back: Yes
Black Water Tank Condition:Acceptable
Gray Water Tank
Gray Water Tank - Valve Operates: Yes
Gray Water Tank - Valve Type: Cable Pull
Gray Water Tank - Tank or Valve or Line Leaks: No
Gray Water Tank - Drain Cap in Place: Yes
Gray Water Tank - Drain Cap Holds Gray Water Back: Yes
Gray Water Tank Condition:Acceptable
Waste Water Sewer / Hose Fittings:Acceptable
Monitor System
Battery Monitor Reading: Unable to Determine
LP Monitor Reading: Not Present
NOTE: The Following Readings Should be AFTER Emptying Tanks if Possible: Results of the Test
Fresh Water Tank Reading: Digital Reading, 0%
Black Water Tank #1 Reading: Digital Reading, 33%
Black Water Tank #2 Reading: Digital Reading, 0%
Gray Water Tank #1 Reading: Digital Reading, 0%
Battery / Waste / Water Monitor Panel Condition:Fair
Monitor Display:
Propane Tank, Lines and Connections
NOTES
-LP Detectors have an estimated service life of 5 years after which time it is recommended they be replaced.
-CO Detectors have an estimated service life of 5 to 7 years after which time it is recommended they be replaced.
-Smoke Detectors have an estimated service life of 5 to 10 years after which time it is recommended they be replaced.
DOT Tanks
DOT - Cylinder Arrangement: Dual Split System
DOT - Hoses and Regulators: Acceptable
DOT #1 - Cylinder Size: 30 LBS
DOT #1 - Date of Manufacture: 2017, 11
DOT Tank #1 - Rust or Damage Condition: Acceptable
DOT #2 - Cylinder Size: 30 LBS
DOT #2 - Date of Manufacture: 2003, 04
DOT Tank #2 - Rust or Damage Condition: Acceptable
DOT - Regulator Type: Dual Input - Auto Change Over
DOT - Regulator Vents Downward: Yes
DOT Tank(s) Condition:Poor
External Propane Port:Acceptable
The inspector observed that the streetside LP tank has a 2003 date code. Propane cylinders must be requalified or replaced every 5 or10 years depending on the cylinder type, condition, and previous requalification method. (Ref. 49 CFR § 180.205(d) and 180.209(e).) Recommend that this be replaced with a newer tank.
DOT Tank:
LP Leak / Drop Test
LP Leak / Drop Test -: Pass
LP Leak / Drop Test - Did Pressure Drop During Leak Test: No
LP Leak / Drop Test - Begin Time: 1:08
LP Leak / Drop Test - Completed Time: 1:12
LP Leak System Test:Acceptable
The propane system passed the leak test.
CO Detector
CO Detector Test Result: Pass
CO Detector Brand / Model: BRK / CO250RVA
CO Detector Date: Five Years Old, 2017 Nov 24
CO Detector UL 2034 or CSA 6.19: Yes
CO Detector Alarm During Test: Yes, by Pushing the Button
CO Detector Condition:Acceptable
The carbon monoxide (C0) detector located near the bedroom ceiling passed the push button test.
Combination LP /CO Detector
Combination LP / CO Detector Test Result: Pass
Combination LP / CO Detector Brand / Model: MTI Industries
Combination LP / CO Detector Date: Four Years Old, JAN 17 2018
Combination LP / CO Detector UL 1484, UL 2034 or CSA 6.19: Yes
Combination LP / CO Detector Test Method: Tested by Pushing Button and Spraying LP
Combination LP / CO Detector Alarm During Test: Yes
Combination LP / CO Detector Condition:Acceptable
The LP/ CO detector located near the galley floor passed the push button test.
Smoke Detector
Smoke Detector Test Result: Pass
Smoke Detector Brand / Model: BRK / FG250RV
Smoke Detector Date: Four Years Old, 2017 DEC 12
Smoke Alarm UL 217: Yes
Smoke Detector Alarm During Test: Yes, by Pushing the Button
Smoke Detector Condition:Acceptable
The smoke detector located near the bathroom ceiling passed the push button test.
Garage Smoke Detector
Smoke Detector Test Result: Pass
Smoke Detector Brand / Model: BRK / FG250RV
Smoke Detector Date: Four Years Old, 2017 Dec 17
Smoke Alarm UL 217: Yes
Smoke Detector Alarm During Test: Yes, by Pushing the Button
Smoke Detector Condition:Acceptable
The smoke detector located near the Garage ceiling passed the push button test.
Fire Extinguisher
Fire Extinguisher - Size: 5 B:C
Fire Extinguisher - Brand: First Alert
Fire Extinguisher - Secure in Bracket: Yes
Fire Extinguisher - Mounted within 24 Inches of Entrance Door: Yes
Fire Extinguisher - Gauge Indicates Charged State: Yes
Fire Extinguisher Condition:Poor
The inspector recommends installing a larger Fire Extinguisher, 10 B:C is recommended.
Fire Extinguisher:
Fire Extinguisher - Garage
Fire Extinguisher - Size: Toy Hauler 10 B:C
Fire Extinguisher - Secure in Bracket: Yes
Fire Extinguisher - Gauge Indicates Charged State: Yes
Fire Extinguisher Condition:Acceptable
Appliances: Kitchen
NOTE:
-Refrigerator needs to be on for a minimum of 12 to 24 hours to be at full cooling condition. This inspection may not reveal a problem if during the inspection the refrigerator was not on for the minimum recommended time.
Refrigerator
Refrigerator - Brand: NORCOLD
Refrigerator - Model #/ Serial #: 2118SST / 28089028
Refrigerator - Cooling Source(s): 120 Volts AC, Propane
Refrigerator - Operates on all Available Sources: Yes
Refrigerator - Type: RV Helium / Hydrogen Absorption
Refrigerator - Control Panel Location: Between Doors
Refrigerator - Door Latch Secure: Yes
Refrigerator - Freezer Current Temperature: Degrees F, 6.7
Refrigerator - Odor Detectable in Freezer: No
Refrigerator - Current Refrigerator Temperature: Degrees F, 29.5
Refrigerator - Has Unit been Running 12 + Hours: No
Refrigerator - Odor Detectable in Refrigerator: No
Refrigerator - Does Inside Light Work: Yes
Refrigerator - Thermostat Sensor Control Mounted on Fins: Yes
Refrigerator - Thermostat Sensor Type: Adjustable
Refrigerator - Recall Installed (Back of Refrigerator): Not Required
Refrigerator - Control Board:Acceptable
Refrigerator - Front Side Door Panels:Acceptable
Refrigerator - Front Side Door Frame:Acceptable
Refrigerator - Inside Freezer Walls:Acceptable
Refrigerator - Ice Maker:Not Present
Refrigerator - Freezer Shelves / Door Racks:Acceptable
Refrigerator - Inside Walls:Acceptable
Refrigerator - Shelves / Door Racks:Acceptable
Refrigerator - Crisper Trays and Drawers:Acceptable
Refrigerator - Backside Cooling Coils / Proper Venting:Acceptable
Cooktop / Oven
Cooktop - Brand: Furrion
Cooktop - Model # / Serial #: FSRE21SS / 1711900167-082017-0019
Cooktop - All Burners Operate: Yes
Cooktop - Rubber Grommets for Stovetop Grate: Yes
Cooktop - Burner Ignition Source: Auto - Piezo Ignition
Cooktop - All Burners Light: Yes
Cooktop - Condition:Acceptable
Cooktop - Condition of Knobs / Controls:Acceptable
Cooktop - Burner Grate / Cover Condition:Acceptable
Cooktop - Color of Burner Flame:AcceptableFair
Oven - Combined With Cooktop: Yes
Oven - Burner Ignition Source: Auto - Piezo Ignition
Oven - Burner Lights: Yes
Oven - Condition:Acceptable
Oven - Racks Condition:Acceptable
Oven - Color of Burner Flame:Acceptable
Microwave
Microwave - Brand: FURRION
Microwave - Model # / Serial #: FMCM15-SS / 1711900817-092017-00035
Microwave - Type: Microwave / Convection
Microwave - Convection Mode - Fan Blower Comes On: Yes
Microwave - Temperature of Water after 60 Seconds: Degrees F, 92
Microwave Condition:Acceptable
Cooktop Exhaust Vent - Part of Microwave: Yes
Cooktop Exhaust Vent - Venting: Vents to Exterior
Cooktop Exhaust Vent Condition:Acceptable
Cooktop Exhaust Vent - Fan Speeds Condition:Acceptable
Dishwasher
Dishwasher - Operational: Not Present
Appliances: Other
Water Heater
Water Heater - Brand: Suburban
Water Heater - Model # / Serial #: SW12DEL / 17510747D
Water Heater - Type: Tank Type
Water Heater - Heat Source(s): Electric, Gas
Water Heater - Operates on all Sources: Not Inspected
Water Heater - Type of Ignition: Direct Spark (DSI)
Water Heater - Leaks at Pressure Relief Valve: No
Water Heater - Proper Drain Plug Installed: No
Water Heater - Dauber Screens Installed: No
Water Heater - Condition of Burner Assembly Area:Acceptable
Water Heater - Rubber Grommet Around Gas Line Sealed:Acceptable
Furnace
Furnace - Brand: Suburban
Furnace - Operates: Yes
Furnace - Floor Vents Blocked or Covered: No
Furnace - Warm Air Discharge Out of Vents - Proper Return Air Flow: Yes
Furnace - Dauber Screens Installed: No
Furnace Air Intake / Exhaust Area Condition:Acceptable
Washer / Dryer
Washer - Operational: Not Present
Dryer - Operational: Not Present
Washer / Dryer - Condition:Not Present
In-House Vacuum System
In-House Vacuum System - Brand: INTERVAC
In-House Vacuum System - Model # / Serial #: CS-RM, Serial number not visible
In-House Vacuum System - Operational: Yes
In-House Vacuum System - Condition of Unit / Accessories / Bag:Acceptable
Electric Fireplace
Electric Fireplace - Brand: Titan Flame
Electric Fireplace - Results of Operation: All Features Work
Electric Fireplace Condition:Acceptable
Ceiling Fan
Ceiling Fan - Condition Motor and Blades:Not Present
Appliances: Air Conditioners
NOTE:
-The Delta-T average acceptable performance range is 14 to 22 degrees (8 to 12 degrees C). In high humidity areas the range ma be lower, 12 to 16 degrees F (7 to 9 degrees C) and in desert areas it may be higher 23 to 26 degrees F (13 to 15 degrees C).
Air Conditioners - Front
Air Conditioner - Brand: Coleman
Air Conditioner - Model # / Serial #: 48254C869 / 180114619
Air Conditioner - Thermostatic Controls: Dual with Furnace
Air Conditioner - Options: AC Only
Air Conditioner - Delta-T: Degrees F, 60.1-36.0=24.1
Air Conditioner Condition:Acceptable
Air Conditioner - Filter Condition:Acceptable
Airconditioner - Exhaust Condition:Acceptable
Air Conditioners - Center
Air Conditioner - Brand: Coleman
Air Conditioner - Model # / Serial #: 48254C869 / 180114618
Air Conditioner - Thermostatic Controls: Dual with Furnace
Air Conditioner - Options: AC Only
Air Conditioner - Delta-T: Degrees F, 58.3-48.7=19.3
Air Conditioner Condition:Fair
Air Conditioner - Filter Condition:Acceptable
Airconditioner - Exhaust Condition:Acceptable
The inspector observed a low Delta-T reading on the AC. It is recommended that this be serviced by a qualified RV technician.
Air Conditioners - Rear/Garage
Air Conditioner - Brand: Coleman
Air Conditioner - Model # / Serial #: 48253C969 / 180112903
Air Conditioner - Thermostatic Controls: Dual with Furnace
Air Conditioner - Options: AC Only
Air Conditioner - Delta-T: Degrees F, 58.1-35.8=22.3
Air Conditioner Condition:Acceptable
Air Conditioner - Filter Condition:Fair
Airconditioner - Exhaust Condition:Acceptable
The inspector observed that the air conditioner filters were dirty. It is recommended that they be cleaned to improve the efficiency of the units.
Interior
NOTE:
-The inspector has verified the items in this section.
Photos & RV Manuals
RV Manuals Present:Yes
Evidence of Animals:No
Odor Detected in RV:No
Ceiling
Ceiling Inspected:Yes
Ceiling - Panels Loose:No
Ceiling - Discoloration or Stains:No
Ceiling - Trim Work Missing or Damaged:No
Ceiling - Condition:Acceptable
Ceiling Vents and Skylights - Thermostatic Controls and Switches Work:Yes
Ceiling Vents - All 12 Volt DC Fans Operate:Yes
Ceiling Vents - All 120 Volt AC Fans Operate:Not Present
Ceiling Vents and Skylights - Stains Around Roof Vents and Skylights:No
Ceiling Vents and Skylights - Condition:Acceptable
Ceiling Vents and Skylights - Trim Ring Around Vents and Skylights:Acceptable
Lights
Lights and Light Fixtures - Do all Lights Function:Yes
Lights and Light Fixtures - Wall Mounted Light Fixtures:Not Inspected
Lights and Light Fixtures - Rope Lights:Not Present
Lights and Light Fixtures - Spot Lights:Yes
Lights and Light Fixtures - Floor Lights:Not Present
Lights and Light Fixtures - Entry Lights inside RV:Yes
Lights and Light Fixtures - Missing or Broken Lenses:No
Lights and Light Fixtures - Missing Shades or Broken Covers:No
Lights and Light Fixtures - Condition:Acceptable
Walls
Walls Inspected:Yes
Walls - Panels Loose:No
Walls - Water Damage Wall Panels:No
Walls - Panels Discolored or Stained:No
Walls - Soft Spots on Walls:No
Walls - Trim Work on Walls:No
Walls - Damage Repairs Performed:No
Walls - Holes or Wall Repairs:No
Walls - Condition:Acceptable
Walls - Interior Doors Condition:Acceptable
Closets
Closets / Pantries Inspected:Yes
Closets and Pantries - Door Damage / Scratches:No
Closets and Pantries - Wood Rot or Broken:No
Closets and Pantries - Condition:Acceptable
Windows, Blinds and Shades
Windows - All Windows Operational:Yes
Windows - Emergency Exit Windows Installed:Yes
Windows - Emergency Exit Windows Operational:Yes
Blinds and Shades - Installed:Yes
Blinds and Shades - Operational:Yes
Windows - Condition:Acceptable
Blinds and Shades - Condition:Acceptable
Flooring
Flooring - Sheet Vinyl:Yes
Flooring - Carpet:No
Flooring - Ceramic Tile:Not Present
Flooring - Tile - Other:Not Present
Flooring - Floor Panels Loose:No
Flooring - Floor Covering Discolored or Stained:No
Flooring - Water Damage:No
Flooring - Carpet Worn:Not Present
Flooring - Sheet Vinyl Stained:No
Flooring - Soft Spots in Floor:No
Flooring - Previous Repairs Performed:No
Flooring - Condition:Acceptable
Kitchen Sink
Kitchen Sink - Style: Double Bowl
Kitchen Sink - Type: Stainless
Kitchen Counter Top Damage:No
Kitchen Sink - Faucet Working:Not Inspected
Kitchen Sink - Faucet Leaks at Stem:Not Inspected
Kitchen Sink - Water Damage Under Sink:Not Inspected
Kitchen Sink - P-Trap Holds Water:Not Inspected
Kitchen Sink - Hot and Cold Water Available:Not Inspected
Kitchen Sink - Condition:Acceptable
Toilet
Toilet - Type: Gravity Flush
Toilet - Water Leaks:No
Toilet - Indication of Previous Damage or Repair:No
Toilet - Bowl Holds:Yes
Toilet - Mounting Problems:No
Operation and Condition of Toilet:Acceptable
Toilet - Garage
Toilet - Type: Gravity Flush
Toilet - Water Leaks:No
Toilet - Indication of Previous Damage or Repair:No
Toilet - Bowl Holds:Yes
Toilet - Mounting Problems:No
Operation and Condition of Toilet:Acceptable
Shower
Shower / Tub - Style: Shower Stall
Shower / Tub - Stains in Stall / Tub:No
Shower / Tub - Water Damage or Leaks:No
Shower / Tub - Glass Doors:Yes
Shower / Tub - Condition:Acceptable
Shower / Tub - Door and Frame and Seals Condition:Acceptable
Operation and Condition of Shower:Not Inspected
Bathroom Sink
Bathroom Sink - Style: Single Bowl
Bathroom Sink - Type: Corian
Bathroom Sink - Faucet Working:Not Inspected
Bathroom Sink - Faucet leaks at Stem:No
Bathroom Sink - Water Damage Under Sink:No
Bathroom Sink - P-Trap Holds Water:Not Inspected
Bathroom Sink - Holds Water:Not Inspected
Bathroom Sink - Hot and Cold Water Available:Not Inspected
Bathroom Sink - Condition:Acceptable
Bathroom Sink - Garage
Bathroom Sink - Style: Single Bowl
Bathroom Sink - Faucet Working:Not Inspected
Bathroom Sink - Faucet leaks at Stem:No
Bathroom Sink - Water Damage Under Sink:No
Bathroom Sink - Holds Water:Not Inspected
Bathroom Sink - Hot and Cold Water Available:Not Inspected
Bathroom Sink - Condition:Acceptable
Furniture
Chairs
Chairs Inspected: Not Present
Chairs - Condition:Not Present
Sofa
Sofa(s) Inspected: Yes
Sofa - Fabric Tears or Separation: No
Sofa - Fabric Discolored or Stains : No
Sofa - Signs of Excess Wear: No
Sofa - Water Damage: No
Sofa - Condition:Acceptable
Dinette / Table / Chairs
Dinette / Table / Chairs - Inspected: Yes
Dinette / Table / Chairs - Fabric Tears or Separation: No
Dinette / Table / Chairs - Fabric Discolored or Stains: No
Dinette / Table / Chairs - Sign of Excess Wear: No
Dinette / Table / Chairs - Water Damage: No
Dinette / Table / Chairs - Previous Repairs: No
Dinette / Table / Chairs - Condition:Acceptable
Beds
Beds Inspected: Yes
Beds - Fabric Tears or Seperation: No
Beds - Fabric Discolored or Stains: No
Beds - Signs of Excess Wear: No
Beds - Pillow Top Mattress: No
Beds - Bed Covers: Not Present
Beds - Covers Match Decor: Not Present
Beds - Condition:Acceptable
Cabinets
Cabinets / Dressers Inspected: Yes
Cabinets / Dressers - Types of Hinges: Hidden
Cabinets / Dressers - Door Damage or Scratches: No
Cabinets / Dressers - Counter Top Damage or Scratches: No
Cabinets / Dresser - Wood Rot or Broken: No
Cabinets / Dressers - Drawer Damage or Scatches: No
Cabinets / Dressers - Condition:Acceptable
Safe
Safe Inspected: Not Present
Safe - Condition:Not Present
Electronics
TV - Living Room
Unit - Brand: TLC
Unit - Model # / Serial #: / 1705GTC001443A00309
Antenna Power Booster Operates: Yes
TV Picks Up Local Channels: Yes
Unit Works Properly:Yes
Unit Cleaned and Maintained:Yes
Unit Properly Mounted and Secured:Yes
TV - Living Room:
TV - Bedroom
Unit - Brand: TLC
Antenna Power Booster Operates: Yes
TV Picks Up Local Channels: Yes
Remotes Operational: Yes
Unit Works Properly:Yes
Unit Cleaned and Maintained:Yes
Unit Properly Mounted and Secured:Yes
TV - Garage
Unit - Brand: TLC
Antenna Power Booster Operates: Yes
TV Picks Up Local Channels: Yes
Remotes Operational: Yes
Unit Works Properly:Yes
Unit Cleaned and Maintained:Yes
Unit Properly Mounted and Secured:Yes
TV - Exterior
Unit - Brand: TLC
Unit Works Properly:Yes
Unit Cleaned and Maintained:Yes
Unit Properly Mounted and Secured:Yes
DVD Player / Radio / Stereo
Unit - Brand: Jensen
Unit Works Properly:Yes
Unit Cleaned and Maintained:Yes
Unit Properly Mounted and Secured:Yes
Toy Hauler Section
Overview
The following inspection items of the toy hauler garage can be found in the indicated chapters and sections;
- Fire Extinguisher Propane Tank...., Fire Extinguisher - Garage
- Air Conditioner Appliances: Air Conditioner, Air Conditioner - Garage
- Toilet Interior, Toilet - Garage
- Bathroom Sink Interior, Bathroom Sink - Garage
Ramp Door
Ramp Door Operation: Operates as intended
Ramp Door Mechanism: Manual
Ramp Door - Condition:Acceptable
Ramp Door Photos:
Interior
Flooring Material: Laminate
Flooring - Condition:Acceptable
Cargo Hooks - Condition:Acceptable
Walls - Condition:Acceptable
Windows - Condition:Acceptable
Windows - All Operational:Yes
Windows - Emergency Exit Installed and Operational:Yes
Cabinets / Dressers - Condition:Acceptable
Cabinets / Dressers / Drawers - Inspected:Yes
Cabinets / Dressers / Drawers - Damage or Scratchesss, Wood Rot, Water Damage:Yes
Beds
Beds - Condition: Acceptable
Bed Lift Type: Electric
Seating Converts into Beds: Yes
Number of Beds: Two
Beds - Fabric Tears or Separation, Discolored or Stains Excessive Wear, Water Damage:No
Life Safety
Danger Label: Yes
Gas Station Static Strap Available: Yes
Report Attachments
PDFs
ATTENTION: This inspection report is incomplete without reading the information included herein at these links/attachments. Note If you received a printed version of this page and did not receive a copy of the report through the internet please contact your inspector for a printed copy of the attachments.