Electrician
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a house by providing a professional opinion about its condition. A home inspection is a limited visual inspection and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend that you attend at least part of the inspection.
A home inspection is not an insurance policy
This report does not substitute for or serve as a warranty or guarantee of any kind. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. Our procedures involve non-invasive investigation and non-destructive testing which limits the scope of the inspection. Where moisture meter testing is indicated in this report a Protimeter Surveymaster was used.
This is not an inspection for code compliance
This inspection and report are not intended for city / local code compliance. During the construction process structures are inspected for code compliance by municipal inspectors. Framing is open at this time and conditions can be fully viewed. Framing is not open during inspections of finished homes, and this limits the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all of the varying disciplines. Municipalities can choose to adopt and phase in sections of the codes on their own timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive. We follow the InterNACHI Standards of Practice and are generally looking for functionality (are things working) and safety issues.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate with the house you are proposing to buy or sell. To this end we assist with discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect with a building. Such inspections are available but they are generally cost-prohibitive to most homebuyers.
General Disclaimers
The approximate square footage listed in the report is listed as a courtesy and is based off of public records and disclosure. An evaluation of square footage of the buildings and property lines is beyond the scope of this inspection.
The number of bedrooms identified is pulled from the MLS listing or public records. Any observed non-conforming bedrooms will be identified in this report.
A thermal imaging camera was used to check walls and ceilings for thermal anomalies and also to check specific appliances for verification of proper function. All thermal images will be pared with a normal picture of the same frame. Thermal imaging cameras use the infrared light spectrum to build a picture of the house. Experienced thermogrophers look for clues in these thermal images that could lead us to otherwise concealed water leaks or missing air or thermal barriers. In older homes, incomplete air and thermal barriers are so common, we will only report on items that look significantly deficient and are worthy of correction. This service is included with our home inspection; it is limited and is not a complete thermal mapping of the house. Note that weather conditions (e.g. whether it has rained in the days/weeks leading up to the inspection) can significant affect the effectiveness of thermal image testing.
When testing appliances, any operational defects noted will be listed in this report. However, just because an appliance turns on and runs, it does not necessarily mean it was working effectively. I was testing for basic function of appliances; testing every feature, option, and the overall effectiveness of the appliance is not feasible during an inspection.
Mold, mold testing, and indoor air quality are beyond the scope of this inspection. That being said, any suspected mold or conducive conditions for mold that we observed will be reported on. If mold or indoor air quality is a particular concern, we recommend an additional evaluation and further inspections by a specialist.
Radon level testing is not included as part of this inspection. While radon is a concern in many areas of the United States, according to the EPA, the Seattle area has low risk for radon levels (see EPA map.) If radon levels are of specific concern, we recommend contacting a company that provides this service. Note that it takes 48+ hours to accurately measure radon levels.
Your participation is requested
Your presence is requested during this inspection. A written report will not substitute for all the possible information that can be conveyed verbally by a shared visual observation of the conditions of the property.
How to Read This Report
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get critical information for important decision making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, descriptions, videos and hot links to additional information. This report can also be printed on paper or to a PDF document, but the best way to get the layers of information that are presented in this report is to read your report online, which will allow you to expand your learning about the inspected property.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left side margin.
Most sections will contain some descriptive information done in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there may be no narrative observation comments in that section and it may simply say “tested,” or “inspected.”
Observation Labels
All narrative observations are colored, numbered and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
- Procedure:Description of the procedure I follow while inspecting various components of a house.
- Note:Refers to aside information and/or any comments elaborating on descriptions of systems in the home or limitations to the home inspection. These also include contextual photos of the house and pictures of various components of the house while operating.
- Tier 1 - Major Concern:These represent priority items like major safety issues, active issues causing damage to the house, or items of significant expense that are looming in the near future.
- Tier 2 - Repair:These are lower priority deficiencies that may not need immediate attention, but should be addressed in the near/medium term future. These are usually deferred maintenance items, occupant safety concerns, or sub-par construction/installation problems.
- Tier 3 - Improve:These are things that are working but could be better. These are minor nuisance type concerns, or things related to safety, efficiency, or reliability issues. Often these are improvements that may not have been necessary--or even have existed--when the property being inspected was constructed (e.g. changes in building standards over time.)
- Future Project:A repair that may be deferred for some time but should be on the radar for repair or replacement in the future.
- Due Diligence:Observations that may require further investigation and/or clarification that could not be provided during the home inspection.
- Monitor:Items that should be watched to see if correction may be needed in the future.
- Recommended Maintenance:These are items that should be considered "routine home ownership," such as servicing the furnace, cleaning the gutters or changing the air filters in the furnace. Generally a house costs ~1% of the purchase price per year to maintain.
- Homeowner Info:These are pieces of "good to know" information about the house. For example, the location of the main water shut-off valve, gas shut-off valve(s), etc.
Summary Page
The Summary Page is designed as a quick-to-read bulleted overview of all the deficiencies noted during inspection. This overview is not a substitution for reading the entire inspection report.
Electrician
Tier 1 - Major Concerns
- E-6 Electrical:
This home appeared to employ some knob and tube wiring. This is an old soldered style of wiring that would not meet today's standards. Some insurance companies will not insure homes with this type of wiring. Many homes of this age in this area still employ at least a few knob and tube circuits, so finding some active knob and tube is not a surprise.
I recommend consulting with a licensed electrician about ways to improve this system and take pressure off existing knob and tube. Installation of additional circuits and of arc fault protected breakers can help make the system safer and more reliable. Complete removal and replacement of all knob and tube is recommended but considerably more expensive and not always necessary.
Contractor:Electrician - E-16 Electrical:
The cover was not properly installed when I arrived. I tried to put it back on in a safer way, but there was only a single screw, and the cover just did not fit the box well, so it still had gaps. Access to the inside of the panel is a significant shock/electrocution concern. Recommend repair by a qualified electrician.
Contractor:Electrician - E-17 Electrical:
One of the breakers had an undersized wire, see photos. It was a 30 amp breaker with a 12 gauge wire; 12 gauge wires are for 20 amp circuits max. This created a situation where the wire will melt before the breaker will trip, which is a significant fire hazard concern. Recommend repair by a qualified electrician.
Contractor:Electrician - E-18 Electrical:
The panel had missing breaker(s) where protective cover(s) were not installed. This allows access to the inside of the panel without removing the front cover and is an electrocution hazard. Recommend installing breaker covers as a DIY repair. They are plastic pieces with clips on them, and are sold at any Home Depot type store.
Contractor:Electrician
Tier 2 - Repairs
- E-7 Electrical:
Improperly performed wire termination(s) was observed, see photo(s.) Terminations should be done in a covered junction box to protect the wires and reduce the risk of electrical fires. Recommend repair by a qualified electrician.
Contractor:Electrician - E-8 Electrical:
Improperly performed wire splice(s) was observed, see photo(s.) Splices should be done in a covered junction box to protect the wires and reduce the risk of electrical fires. Recommend repair by a qualified electrician.
Contractor:Electrician - E-9 Electrical:
There was an open junction box in the back entry way. This allowed easy access to wire splices, which should protected to keep them from coming loose. Normally, a box like this just has a door that can be closed. However, a wire was running out of the box (improperly) so the door could not be closed. Recommend repair by a qualified electrician.
Contractor:Electrician - E-19 Electrical:
Breaker(s) from a different brand from the panel manufacturer were present in the panel (Cutler-Hammer, GE, and Siemens brand breakers in a Bryant brand panel.) Most panel manufacturers require their same brand breakers to ensure a proper fit. Mismatched breakers can sometimes result in loose connections, which is an electrical fire hazard. Some brands are tested and claim to be cross compatible, though there is a debate about whether this is true or not (see this article.) Recommend evaluation and possible repair by a qualified electrician.
Contractor:Electrician - E-20 Electrical:
One of the wires did not have a plastic/rubber bushing where it entered the panel, see photo. The bushings are to prevent the wires from rubbing on sharp metal edges, which could damage them. Recommend repair by a qualified electrician.
Contractor:Electrician - E-28 Electrical:
Outlet(s) was not functioning, see photo(s.) Recommend repair by a qualified electrician.
Contractor:Electrician - E-29 Electrical:
Open grounds were observed in the house. This is a common condition in older buildings (prior to 1962) where three prong receptacles have been installed on an older two wire system. This creates a shock and fire hazard as it is false advertising; appliances that rely on an equipment ground to discharge a fault can be inadvertently plugged into ungrounded circuits. Proper repair can include:
- Running an equipment grounding conductor or a new three-wire circuit
- Filling the third prong of the receptacle
- Restoring a two-prong receptacle
- Installing GFCI protection for this circuit (if GFCI protection is used, the outlets on this circuit should be labeled so it is clear they are protected.)
Recommend repair by a qualified electrician.
Because many of the outlets in the house had open grounds, and it's possible I missed testing some, I recommend purchasing a simple outlet tester (often less than $10, like this one) to verify that electrical equipment that requires a ground is actually plugged into a grounded outlet.
Photographs of a tester are of the condition present in outlet from the previous photo.
Contractor:Electrician - E-30 Electrical:
Reverse polarity was noted at an electrical receptacle. This is when the hot and the neutral wires have been connected to the wrong terminals in the outlet, which creates a shock hazard. Recommend repair by a qualified electrician.
Photographs of a tester are of the condition present in outlet from the previous photo.
Contractor:Electrician - E-31 Electrical:
No 3-way switch was installed at the basement stair case. 3-way switches (controlled by two switches) should be installed at stairways so lights can be operated from the top and bottom. This helps prevent fall hazards on poorly lit staircases. Recommend installation of a 3-way switch by a qualified electrician.
Note: I think there was a 3-way switch for the stairs to the second level, but the light over the stairs did not have a bulb, so I could not be sure.
Contractor:Electrician - E-36 Electrical:
GFCI protection did not appear to be present in the kitchen and bathroom. This is a shock hazard for occupants. Recommend installation of GFCI protection by a qualified electrician.
Contractor:Electrician
Tier 3 - Improvements
- E-10 Electrical:
Wire(s) was not protected. Modern building standards recommend that electrical wire be installed in a guarded way, either through studs or in conduit, to help prevent damage to the wire. Recommend repair by a qualified electrician.
Contractor:Electrician - E-21 Electrical:
Arc Fault Circuit Interrupter (AFCI) breakers were not observed on all the recommended circuits in the panel. Modern building standards require most living spaces be protected by AFCI breakers which are a fire prevention device. The current version of the National Electric Code states: "All 120-volt, single phase, 15- and 20-ampere branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms or areas shall be protected." Recommend having a qualified electrician install AFCI breakers where required as a safety improvement.
Contractor:Electrician - E-22 Electrical:
No surge protection device was noted, which started being recommended by modern building standards in 2020. Recommend installation of a surge protector by a qualified electrician.
Contractor:Electrician - E-23 Electrical:
Panel was missing a complete legend displaying which breakers control which circuits. Recommend the homeowner or an electrician creates one.
Contractor:DIY (do it yourself)Electrician - E-24 Electrical:
Modern building standards state that power to the entire structure should be able to be cut with six or less breakers. In a split bus panel like this, that means the top have (highlighted) should have six breakers or less. This panel had more than that. Recommend repair by a qualified electrician.
Contractor:Electrician - E-33 Electrical:
I did not find any exterior receptacles during the inspection. Modern building standards require one in the front and one in the back of the house. Recommend installation of exterior outlets by a qualified electrician.
Contractor:Electrician - E-34 Electrical:
Ungrounded, 2-prong electrical outlets were present in the house. Although this condition may have been commonly considered safe or acceptable at the time the home was originally constructed, these are ungrounded electrical systems, which can be unsafe. Recommend replacement by a qualified electrician.
Contractor:Electrician - E-35 Electrical:
Modern building standards require bedrooms to have at least two outlets. Both first level bedrooms and the second level south bedroom only had one outlet. Recommend installation of a second outlet in each room by a qualified electrician.
Contractor:Electrician