Pool Electrical Summary
Pool Electrical Summary Only Summary
This was created to contain all of the pool electrical summary items that are in the full inspection report summary in one location for easy reference.
Pool Electrical Summary
Pool Due Diligences
- PE-5 Pool Electrical - Pool Lighting:
The pool lighting system had no (requires verification) ground fault circuit Interrupter (GFCI) protection. Recommend that ground fault circuit Interrupter GFCI protection be installed.
Pool Repair Items
- PE-2 Pool Electrical - Electrical Panel, Wiring, GFCI and Bonding:
There was no ground fault circuit interrupter (GFCI) protection for the pool at the time of inspection. This can be achieved relatively inexpensively by replacing the breaker currently protecting the electrical circuit that contains the circuits of concern with a GFCI breaker. Recommend repairs as needed.
- PE-3 Pool Electrical - Electrical Panel, Wiring, GFCI and Bonding:
The GFCI receptacle protecting pool electrical circuits failed to respond to testing and should be replaced.
- PE-6 Pool Electrical - Pool Lighting:
Condensation visible (requires verification) in the pool light housing indicated a loss of seal integrity. Recommend evaluation and repairs as needed.
Pool Repairs - Minor
- PE-4 Pool Electrical - Electrical Panel, Wiring, GFCI and Bonding:
The pool sub-panel cabinet had inadequate working clearance in front. Modern safety standards require a minimum open space 30-inches in width for a height of 6-feet 6-inches. Minimum clearance in front of the cabinet should be 3-feet. Recommend repairs as needed.