Matt Shiff, VA State License #3380002221
The Scope and Purpose of a Home Inspection
Purchasing property involves risk
The purpose of a home inspection is to help reduce the risk associated with the purchase of a structure by providing a professional opinion about the overall condition of the structure. A home inspection is a limited visual inspection, and it cannot eliminate this risk. Some homes present more risks than others. We cannot control this, but we try to help educate you about what we don’t know during the inspection process. This is more difficult to convey in a report and one of many reasons why we recommend you attend the inspection.
A home inspection is not an insurance policy.
This report does not substitute for or serve as a warranty or guarantee. Home warranties can be purchased separately from insuring firms that provide this service.
A home inspection is visual and not destructive.
The descriptions and observations in this report are based on a visual inspection of the structure. We inspect the aspects of the structure that can be viewed without dismantling, damaging, or disfiguring the structure and without moving furniture and interior furnishings. Areas that are concealed, hidden, or inaccessible to view are not covered by this inspection. Some systems cannot be tested during this inspection as testing risks damaging the building. For example, overflow drains on bathtubs are generally not tested because if they were found to be leaking, they could damage the finishes below. Our procedures involve non-invasive investigation and non-destructive testing, which will limit the scope of the inspection. We follow the InterNACHI standards of practice which can be found at the following link: https://www.nachi.org/sop.htm.
This is not an inspection for code compliance.
This inspection and report are not intended for city / local code compliance. During the construction, process structures are inspected for code compliance by municipal inspectors. Framing is open at this time, and conditions can be fully viewed. Framing is not open during inspections of finished homes, limiting the inspection. All houses fall out of code compliance shortly after they are built, as the codes continually change. National codes are augmented at least every three years for all disciplines. Municipalities can adopt and phase in sections of the codes on their timetables. There are generally no requirements to bring older homes into compliance unless substantial renovation is being done.
This is just our opinion.
Construction techniques and standards vary. There is no one way to build a house or install a system in a house. The observations in this report are the opinions of the home inspector. Other inspectors and contractors are likely to have some differing opinions. You are welcome to seek opinions from other professionals.
The scope of this inspection
This inspection will include the following systems: exterior, roof, structure, drainage, foundation, attic, interior, plumbing, electrical, and heating. The evaluation will be based on limited observations that are primarily visual and non-invasive. This inspection and report are not intended to be technically exhaustive.
Your expectations
The overall goal of a home inspection is to help ensure that your expectations are appropriate for the house you are proposing to buy. To this end, we assist with the discovery by showing and documenting observations during the home inspection. This should not be mistaken for a technically exhaustive inspection designed to uncover every defect in a building. Such inspections are available, but they are generally cost-prohibitive to most homebuyers.
Your participation is requested.
Your presence is requested during this inspection. A written report will not substitute for all the possible information that can be conveyed verbally by a shared visual observation of the conditions of the property.
How to Read This Report
Getting the Information to You
This report is designed to deliver important and technical information in a way that is easy for anyone to access and understand. If you are in a hurry, you can take a quick look at our "Summary Page” and quickly get the critical information for important decision-making. However, we strongly recommend that you take the time to read the full Report, which includes digital photographs, captions, diagrams, descriptions, videos, and hot links to additional information.
The best way to get the layers of information presented in this report is to read your report online, which will allow you to expand your learning about your house. You will notice some words or series of words highlighted in blue and underlined – clicking on these will provide you with additional information.
This report can also be printed to a PDF file and printed on paper as desired.
Chapters and Sections
This report is divided into chapters that parcel the home into logical inspection components. Each chapter is broken into sections that relate to a specific system or component of the home. You can navigate between chapters with the click of a button on the left-side margin.
Most sections will contain some descriptive information in black font. Observation narrative, done in colored boxes, will be included if a system or component is found to be significantly deficient in some way or if we wish to provide helpful additional information about the system or the scope of our inspection. If a system or component of the home was deemed to be in satisfactory or serviceable condition, there might be no narrative observation comments in that section, and it may simply say “tested” or “inspected.”
Observation Labels
All narrative observations are colored, numbered, and labeled to help you find, refer to, and understand the severity of the observation. Observation colors and labels used in this report are:
- Major Concern:Repair items that may cost significant money to correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminate safety hazards.
- Repair:Repair and maintenance items noted during inspection. Please note that some repair items can be expensive to correct such as re-finishing hardwood floors, but are considered simply repair items due to their cosmetic nature.
- Due Diligence:Observation such as a buried oil tank that may require further investigation to determine the severity and / or urgency of repair.
- Monitor:Items that should be watched to see if correction may be needed in the future.
- Inspection Notes:Aside information and /or comments elaborating on descriptions of systems in the home that the inspector might find useful to purchase decisions or home ownership. .
- Limitations:Conditions present at the time of inspection which limited the scope of this visual inspection
Summary Page
The Summary Page is designed as a bulleted overview of all the observations noted during the inspection. This helpful overview is not a substitute for reading the entire inspection report. The entire report must be read to get a complete understanding of this inspection report, as the Summary Page does not include photographs or photo captions.
Summary
Major Concerns
No major concerns were noted during this visual inspection.Repairs
- G-2 Grounds:
Drains at Foundation
One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a Handyman or Homeowner install water tight downspout extensions to drain at least 6 feet from the foundation.
- G-3 Grounds:
Crack
Crack noted at door at bottom of stairwell. Recommend repair as needed by qualified contractor.
- E-2 Exterior:
Missing or Damaged Flashing
Flashings were missing or damaged at time of inspection. Flashings provide protection against moisture intrusion. Recommend a qualified siding contractor evaluate and remedy.
- E-3 Exterior:
Localized Siding and Trim Repairs Needed
Repairs are needed to the exterior siding and/or trim. Recommend repair as needed by a qualified contractor. Examples of observations noted during the inspection include:
- Missing trim
- DPB-2 Decks, Porches, and Balconies:
Anchors Close to Edge
For concrete piers, standard engineering guidelines suggest drilling anchors at least 2 to 3 inches—or roughly 10 times the anchor diameter—away from the edge to prevent the concrete from spalling or cracking under structural loads. Recommend review and repair as needed by qualified deck or general contractor.
- DPB-4 Decks, Porches, and Balconies:
Form Still Attached
Wooden boards are still attached to the porch from the concrete pour. Remove and ensure finish is satisfactory.
- HZ1-4 HVAC Zone 1:
Compressor Not Secured
The AC compressor does not appear to be securely attached to the elevated brackets. Recommend repair as needed by a qualified HVAC contractor.
- HZ1-6 HVAC Zone 1:
Grate Missing
Missing grate in Family Room floor vent.
- P-5 Plumbing:
Discharge at Foundation
The sump pump discharges at or near the foundation. Ideally, the pump should discharge 10 to 20 feet away from the house. Recommend extending pipe further out to avoid water issues.
- P-6 Plumbing:
Sump Cover Not Sealed
Recommend screwing down the sump pump covers to prevent a falling hazard and for odor and moisture control, as it prevents musty air and humidity from seeping into your basement.
- G1-2 Garage:
Adjust Travel Length
The overhead garage door did not fully open using the wall control. Recommend adjustment by qualified person to ensure proper operation.
- UR-2 Utility Room:
Typical Cracks
The concrete slab has some minor to moderate cracks. This is typical for concrete and at this time appears cosmetic. They can be filled with concrete sealers if desired.
- DR-2 Dining Room:
Window Repairs Needed
Repairs are needed to one or more windows in this room. Examples of observations include:
- Window frame damaged
- B21-2 Bathroom 2:
Diverter Leaking
There is a steady leak from the tub spout and shower faucet. Recommend repair by a qualified plumbing contractor.
- B41-2 Bathroom 4:
Missing Drain Cover
The drain cover in the shower is not installed.
- K-2 Kitchen:
Minor Cabinetry Repairs
There are some minor repairs and finishing touches that are needed on the cabinetry. Examples include:
- Missing drawer trim
- Trash drawer wobbly
Due Diligence Items
- B-2 Bathroom:
Tub Not Level
Ideally, tubs should be set level. This tub has a slight pitch towards the floor. Tub was partially filled and drainage appeared functional. Recommend inquiring with seller about possible improvements if this is a concern. Monitor area for spills.
Items for Monitoring
- G-4 Grounds:
Monitor Drain
The stairwell drain appears to be unobstructed, but recommend monitoring and keeping clear.
- SB-1 Structure and Basement:
Bow in Wall
There is a noticeable bow in the basement wall around the clean out door. This doesn't appear to be a structural issue, but recommend monitoring area for potential drywall cracks.
- L-2 Laundry:
Yearly Maintenance
Recommend having the dryer vent cleaned on a yearly basis to remove combustible lint buildup.
Home Inspection Report
Grounds
General Grounds Photos
Address Identification
Drainage and Site
Driveway, Walkway and Flatwork
Window & Stairwells
Grounds, Trees, and Vegetation
Exterior Stairs
Retaining Walls
Fences and Gates
Outbuildings
Roof, Chimney, and Gutters
General Roof Photos
Roof Materials
Gutters and Downspouts
Roof Penetrations
Chimneys
Decks, Porches, and Balconies
General Deck Photos
Ledger Board
Posts, Beams, and Footings
Guardrail
Stairs
Decking Material
Porches
HVAC Zone 1
General
Cooling Equipment
Heating Equipment
Operating Controls
Vents and Flues
Condensate Disposal
Distribution Systems
Plumbing
Water Service Supply
Distribution Pipe
Waste Pipe and Discharge
Exterior Hose Bibs
Sump Pumps and Drains
Electric Service
Electric Service
Electric Service Equipment
Appliance Disconnects
Smoke and CO Detectors
Bathroom
General Photos
Sinks and Cabinets
Toilet
Bathtub/Shower
Bathroom Ventilation
Finishes
Flooring
Electrical
Bathroom 2
General Photos
Sinks and Cabinets
Toilet
Bathtub/Shower
Bathroom Ventilation
Finishes
Flooring
Electrical
Bathroom 3
General Photos
Sinks and Cabinets
Toilet
Bathtub/Shower
Bathroom Ventilation
Finishes
Flooring
Electrical
Bathroom 4
General Photos
Sinks and Cabinets
Toilet
Bathtub/Shower
Bathroom Ventilation
Finishes
Flooring
Electrical
General Comments
Building Characteristics, Conditions, and Limitations
Style of Home: Colonial
Type of Home: Detached
Approximate Square Footage: 2400
Approximate Year of Construction: 2026
Attending Inspection: Buyer and Agent
Occupancy: Unoccupied
Animals Present: No
Weather Conditions: Cloudy
Approximate Temperature: 73 degrees
Ground/Soil Surface Conditions: Wet
Approximate Start Time: 9:00 AM
Approximate End Time: 12:30 PM
Grounds
General Grounds Photos
General Photos: General Photos
General Photos
Address Identification
Address Identification: Address Numbers Present and Well Displayed
Drainage and Site
Clearance to Grade: Functional
Downspout Discharge: Next to Foundation
Site Description: Moderate Slope
Drains at Foundation
One or more downspouts drain too close to the home's foundation. This can result in excessive moisture in the soil at the foundation, which can lead to foundation/structural movement. Recommend a Handyman or Homeowner install water tight downspout extensions to drain at least 6 feet from the foundation.
Driveway, Walkway and Flatwork
Driveway Material: Asphalt
Walkway Material: Concrete
Window & Stairwells
Window/Stairwell Present: Present
Stairwell: Monitor Drain
Crack
Crack noted at door at bottom of stairwell. Recommend repair as needed by qualified contractor.
Grounds, Trees, and Vegetation
Trees/Vegetation in proximity to home: No
Exterior Stairs
Exterior Stairs: None Noted
Retaining Walls
Retaining Wall Material: None Noted
Fences and Gates
Exterior Fencing: None
Outbuildings
None Noted
Roof, Chimney, and Gutters
Roof Materials
Method of Roof Inspection: Viewed with a Camera Stick
Roof Style: Gable
Roof Covering Materials: Architectural Composition Shingle
Architectural Grade Composition Shingle
Composite or "Asphalt" shingles are the most popular roof coverings. They are called “composition” because they are a composite of a fiberglass reinforcement mat that is coated with asphalt and mineral fillers, which adhere to the fiberglass. The asphalt forms a waterproof barrier. Ceramic granules, or “gravel” are embedded in the surface of the asphalt top to provide additional durability. The life expectancy of these composite shingles are usually 20-30 years.
Flashing : Present and Visually Standard
Roof flashings are used to keep a roofing system waterproof where the roofing material starts, stops, changes direction, or is penetrated.
Gutters and Downspouts
Gutter and Downspout Materials: Aluminum
Roof Penetrations
Roof Penetrations: Plumbing Vent, Appliance Vent
Chimneys
None Noted
Exterior
General Exterior Photos
General Photos: General Photos
General Photos
Siding and Trim
Trim Material: Fiber Cement
Siding Material: Fiber Cement
Missing or Damaged Flashing
Flashings were missing or damaged at time of inspection. Flashings provide protection against moisture intrusion. Recommend a qualified siding contractor evaluate and remedy.
Localized Siding and Trim Repairs Needed
Repairs are needed to the exterior siding and/or trim. Recommend repair as needed by a qualified contractor. Examples of observations noted during the inspection include:
- Missing trim
Eaves
Characteristics: Vinyl, Soffit Vents Noted
Exterior Doors
Exterior Door Styles: Solid Core
Exterior Windows
Window Frames: Vinyl
Decks, Porches, and Balconies
Ledger Board
Structure: Present
Posts, Beams, and Footings
Type: Masonry
Anchors Close to Edge
For concrete piers, standard engineering guidelines suggest drilling anchors at least 2 to 3 inches—or roughly 10 times the anchor diameter—away from the edge to prevent the concrete from spalling or cracking under structural loads. Recommend review and repair as needed by qualified deck or general contractor.
Guardrail
Material: Plastic
Stairs
Exterior Stairs: None Noted
Decking Material
Type: Composite
Porches
Form Still Attached
Wooden boards are still attached to the porch from the concrete pour. Remove and ensure finish is satisfactory.
Fuel Storage and Distribution
Gas Meter
Present
Gas Shut Off: General Photos
General Photos
Fuel Piping
Gas Piping Materials: Steel
HVAC Zone 1
General
General Photos: General Photos
Split System
The air conditioning system is a split system in which the cabinet housing the compressor, cooling fan and condensing coils was located physically apart from the evaporator coils. As is typical with split systems, the compressor/condenser cabinet was located at the home's exterior so that the heat collected inside the home could be released to the outside air.
Cooling Equipment
Location: Left Side of House
Energy Source/Type: Electric
Year Built: Life Expectancy, 2026
Life Expectancy
Average life expectancy of an AC compressor is 15 to 20 years, but completing annual maintenance and being diligent with repairs can extend its life longer. This unit was manufactured in 2026.
Compressor Not Secured
The AC compressor does not appear to be securely attached to the elevated brackets. Recommend repair as needed by a qualified HVAC contractor.
Heating Equipment
Location: Basement
Energy Source: Natural Gas
Heating Method: Forced Air
Year Built: Life Expectancy
Life Expectancy
Average life expectancy of a furnace is 15 to 20 years, but completing annual maintenance and being diligent with repairs can extend its life longer. The approximate date of manufacture of this unit is 2026.
Operating Controls
Location: Family Room, Bedroom
Type: Digital
Functional At Inspection: Yes
Vents and Flues
Vent Type: PVC
Condensate Disposal
Material: PVC
Distribution Systems
Distribution Method: Forced Air/Ducts
Heat Source in Each Room: Present
Temperature Differential: Functional
Grate Missing
Missing grate in Family Room floor vent.
Plumbing
Water Service Supply
Water Supply: Public Water
Supply Pipe Material: Plastic
Main Water Shut Off Location: Water Shut Off Location
Water Shut Off Location
This shows the location of the main water shut off..
Pressure Reducing Valve: Present
Pressure Reducing Valve
This house has a pressure reducing valve to control the water pressure.
Distribution Pipe
Supply Pipe Materials: CPVC
Functional Flow: Acceptable
Waste Pipe and Discharge
Exterior Hose Bibs
Hose Bib Shut Off Location
Sump Pumps and Drains
Floor Drain: None Noted
Discharge at Foundation
The sump pump discharges at or near the foundation. Ideally, the pump should discharge 10 to 20 feet away from the house. Recommend extending pipe further out to avoid water issues.
Sump Cover Not Sealed
Recommend screwing down the sump pump covers to prevent a falling hazard and for odor and moisture control, as it prevents musty air and humidity from seeping into your basement.
Water Heaters
Water Heater
General Photos: General Photos
General Photos
System Type: Tankless
Year Built: 2026
Energy Source: Gas
Vents and Flues
Vent Type: PVC
Water Temperature
Average Water Temperature: Testing Note
Water Temperature
The water temperature was tested multiple times at various fixtures during the inspection, and had an average reading of about 120 degrees. Recommend the water heater be set to 120 degrees. This temperature kills most microbes and is comfortable to most people. Temperatures over 140 degrees can cause scalding in a few seconds.
Electric Service
Electric Service
Service Entrance: Below Ground
Meter Base Amperage: 200
Electric Service Equipment
Main Electric Panel Location: Garage
Main Panel Amperage: 200 amps
Electric Service Amperage: 200 amps
Overcurrent Protection Devices: Breakers
Wire Material: Copper, Multi-strand Aluminum
Wiring Method: Non-metallic Sheathed Cable
Appliance Disconnects
Disconnects Noted: AC, Furnace
Smoke and CO Detectors
Smoke Alarms: Required Statement
Required Statement
It is recommended that homes have smoke alarms on each level of the dwelling and in every bedroom or sleeping area. Clients should replace any existing smoke alarms that are not in good working order with new ones and install smoke alarms where they may be missing or not properly located. Any test of a smoke alarm during a home inspection only reflects its condition at the time of inspection and is not a guarantee, warranty, or any form of insurance. A test performed during the home inspection does not supersede the smoke alarm manufacturer's testing recommendations. Clients should follow the manufacturer's instructions for proper placement, installation, and maintenance.
Garage
General Photos
General Photos: General Photos
General Photos
Garage General
Garage Type: Two Car
Doors and Openers
Garage Door Type: Vinyl
Garage Opener: Present
Garage Entry Door: Fire Rated
Adjust Travel Length
The overhead garage door did not fully open using the wall control. Recommend adjustment by qualified person to ensure proper operation.
Entry and Stairs
Garage Stairs: Present
Electrical
Lights: Tested
Outlets and Switches: All Tested
Attic
General Photos
Photos: General Attic Photos
General Attic Photos
Attic Access
Method of Inspection: Viewed from Access
Viewed Attic From Access
There is no platform or safe way to access the attic space. Crawling through insulation and on top of framing risks damaging thermal barriers and ceiling finishes and is not a safe way to access the attic. This limited inspection of this space.
Framing and Sheathing
Rafters: Truss
Sheathing: OSB
Fire Separation
Fire Blocking & Separation in Attic: Not Visible
Insulation
Insulation Type: Cellulose
Approximate R-Value on Attic Floor: 49
Approximate Depth: 16"
Attic Ventilation
Ventilation Method: Soffit Vents, Ridge Vents
Structure and Basement
Foundation
Building Configuration: Basement
Foundation Type: Poured Concrete
Framing
Wall Framing: Partly Visible
Wall Sheathing: Not Visible
Floor Framing: Partly Visible, Dimensional Lumber
Sub-Floor Material: Partly Visible, OSB
Ceiling Framing: Not Visible
Basement
Type: Full, Finished
Bow in Wall
There is a noticeable bow in the basement wall around the clean out door. This doesn't appear to be a structural issue, but recommend monitoring area for potential drywall cracks.
Mud Room
Flooring
Floor Materials: Laminate
Finishes
Wall and Ceiling Materials: Drywall
Doors
Interior Doors: Hollow Core
Electrical
Lights: Tested
Outlets and Switches: Tested
Upper Level Hallway
Flooring
Floor Materials: Carpet
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Electrical
Lights: Tested
Outlets and Switches: Outlets (Tested)
Smoke Detector: Present
Utility Room
Flooring
Floor Materials: Concrete
Observations: Concrete (Typical Cracks)
Typical Cracks
The concrete slab has some minor to moderate cracks. This is typical for concrete and at this time appears cosmetic. They can be filled with concrete sealers if desired.
Finishes
Wall and Ceiling Materials: Unfinished
Electrical
Lights: Tested
Outlets and Switches: Tested
Study
Flooring
Floor Materials: Vinyl Plank
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Electrical
Lights: Tested
Outlets and Switches: Tested
Dining Room
Flooring
Floor Materials: Vinyl Plank
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Window Repairs Needed
Repairs are needed to one or more windows in this room. Examples of observations include:
- Window frame damaged
Doors
Exterior Door: Solid Core
Electrical
Lights: Tested
Outlets and Switches: Tested
Family Room
Flooring
Floor Materials: Vinyl Plank
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Electrical
Lights: Tested
Outlets and Switches: Tested
Bedroom
Flooring
Floor Materials: Carpet
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Doors
Interior Doors: Hollow Core
Electrical
Lights: None
Outlets and Switches: Tested
Smoke Detector: Present
Bedroom 2
Flooring
Floor Materials: Carpet
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Doors
Interior Doors: Hollow Core
Electrical
Lights: None
Outlets and Switches: Tested
Smoke Detector: Present
Bedroom 3
Flooring
Floor Materials: Carpet
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Doors
Interior Doors: Hollow Core
Electrical
Lights: None
Outlets and Switches: Tested
Smoke Detector: Present
Bedroom 4
Flooring
Floor Materials: Carpet
Finishes
Wall and Ceiling Materials: Drywall
Windows
Window Frame: Vinyl
Window Style: Single Hung
Window Glazing: Double Pane
Doors
Interior Doors: Hollow Core
Electrical
Lights: None
Outlets and Switches: Tested
Smoke Detector: Present
Bathroom
Sinks and Cabinets
Tested
Toilet
Tested
Bathtub/Shower
Tested
Shower Type: Tile
Tub Type: Fiberglass
Tub Not Level
Ideally, tubs should be set level. This tub has a slight pitch towards the floor. Tub was partially filled and drainage appeared functional. Recommend inquiring with seller about possible improvements if this is a concern. Monitor area for spills.
Bathroom Ventilation
Type: Bath Fan
Finishes
Wall and Ceiling Materials: Drywall
Flooring
Floor Materials: Tile
Electrical
Lights: Tested
Outlets and Switches: Tested, GFCI Protected
Bathroom 2
Sinks and Cabinets
Tested
Toilet
Tested
Bathtub/Shower
Tested
Shower Type: Tile
Tub Type: Fiberglass
Diverter Leaking
There is a steady leak from the tub spout and shower faucet. Recommend repair by a qualified plumbing contractor.
Bathroom Ventilation
Type: Bath Fan
Finishes
Wall and Ceiling Materials: Drywall
Flooring
Floor Materials: Tile
Electrical
Lights: Tested
Outlets and Switches: Tested, GFCI Protected
Bathroom 3
Sinks and Cabinets
Tested
Toilet
Tested
Bathtub/Shower
None
Bathroom Ventilation
Type: Bath Fan
Finishes
Wall and Ceiling Materials: Drywall
Flooring
Floor Materials: Vinyl Plank
Electrical
Lights: Tested
Outlets and Switches: Tested, GFCI Protected
Bathroom 4
Sinks and Cabinets
Tested
Toilet
Tested
Bathtub/Shower
Tested
Shower Type: Tile
Missing Drain Cover
The drain cover in the shower is not installed.
Bathroom Ventilation
Type: Bath Fan
Finishes
Wall and Ceiling Materials: Drywall
Flooring
Floor Materials: Tile
Electrical
Lights: Tested
Outlets and Switches: Tested, GFCI Protected
Fans: Tested
Laundry
Washer
Not Installed
Dryer
Not Installed
Power Source: Electric
Exhaust: Ducted to Exterior
Yearly Maintenance
Recommend having the dryer vent cleaned on a yearly basis to remove combustible lint buildup.
Kitchen
Sinks and Faucets
Tested
Cabinets and Countertops
Countertop Material: Corian
Cabinet Material: Wood
Minor Cabinetry Repairs
There are some minor repairs and finishing touches that are needed on the cabinetry. Examples include:
- Missing drawer trim
- Trash drawer wobbly
Disposals
Disposal: Operated
Dishwasher
Dishwasher: Operated
Ventilation Method
Fan Ducted to Exterior
Ranges, Ovens, and Cooktops
Range, Oven, & Cooktop: Gas
Refrigerators
Refrigerator: Operating
Electrical
Lights: Tested
Outlets and Switches: Tested, GFCI Protected
GFCI Reset Location
The reset for the kitchen GFCI receptacles is located in the electrical panel in the garage. Breakers #13 and #11.
Check out Procedure
Check Out List
Oven: Off
Lights: Off
Heating and Cooling: Restored to Pre-Inspection Settings
Appliances: Off / Finishing Cycle